• Title/Summary/Keyword: 매체순환연소

Search Result 43, Processing Time 0.02 seconds

The Development of Scrubber for F-gas Reduction from Electronic Industry Using Pressure Swing Adsorption Method and Porous Media Combustion Method (압력순환흡착법과 다공성 매체 연소법을 이용한 전자산업 불화가스 저감 스크러버 개발)

  • Chung, Jong Kook;Lee, Ki Yong;Lee, Sang Gon;Lee, Eun Mi;Mo, Sun Hee;Lee, Dae Keun;Kim, Seung Gon
    • Clean Technology
    • /
    • v.23 no.2
    • /
    • pp.181-187
    • /
    • 2017
  • The perfluorocompounds (PFCs) emitted from the semiconductor and display manufacture is treated by abatement systems which use various technologies, such as combustion, thermal, plasma, catalyst. However, it is required that the system should overcome their drawbacks with excess energy consumption and low removal efficiency. The new technology using combination of pressure swing adsorption and excess enthalpy combustion for the reduction of PFCs emissions were developed and analyzed its characteristics. PFCs concentration ratio and PFCs loss factor were calculated from measuring concentration of PFCs at the calculated by comparing concentration of PFCs at the combustor's inlet and outlet. There were performance evaluations with various gas flow for comparing energy consumption and removal efficiency with existing equipments. The concentration ratio and the loss factor of PFCs were 1.65, 8.2%, respectively, when the total gas flow of the pressure swing absorption (PSA) inlet was 204 liter per minute (LPM) and $CF_4$ concentration was 1412 ppm. In comparison with existing system at constant condition, $CF_4$ removal efficiency for a porous media combustion (PMC) showed the improvement more than 16% and the consumed energy was also reduced up to approximately 41%. Then, the total gas flow introduced into PMC and $CF_4$ concentration were 91-LPM and 2335 ppm, respectively, and the destruction and removal efficiency of $CF_4$ was about 96% at 19-LPM $CH_4$, and 40-LPM $O_2$.

Reaction Characteristics and Kinetics of Ni-bsed Oxygen Carrier for Chemical Looping Combustion (매체순환연소를 위한 Ni계열 산소전달입자의 반응 특성 및 반응 모델)

  • PARK, JI HYE;HWANG, RA HYUN;BAEK, JEOM-IN;RYU, HO-JUNG;YI, KWANG BOK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.1
    • /
    • pp.90-96
    • /
    • 2018
  • Reaction characteristics and kinetics of a oxygen carrier (OCN717-R1SU) for chemical looping combustion (CLC) have been investigated using TGA by changing gas concentration (10-30 vol.% $CH_4$) and reaction temperature ($825-900^{\circ}C$). Reaction rate of OCN717-R1SU increased as temperature increased and it was found that reaction is delayed at the initial reaction regime. Johnson-Mehl-Avrami (JMA) model was adopted to explain the reaction phenomenon. The activation energy (E) determined by JMA model in reduction reaction of OCN717-R1SU is $151.7{\pm}2.03kJ/mol$ and pre-exponential factor and JMA exponent were also obtained. The parameters calculated in this study will be applied in design of the reactor and operation conditions for CLC process.

Hydrodynamic Properties of Interconnected Fluidized Bed Chemical-Looping Combustors (상호 연결된 유동층 매체 순환식 연소로의 수력학적 특성)

  • Son, Sung Real;Go, Kang Seok;Kim, Sang Done
    • Korean Chemical Engineering Research
    • /
    • v.48 no.2
    • /
    • pp.185-192
    • /
    • 2010
  • The chemical-looping combustion(CLC) has advantages of no energy loss for separation of $CO_2$ without $NO_x$ formation. This CLC system consists of oxidation and reduction reactors where metal oxides particles are circulating through these two reactors. In the present study, the reaction kinetic equations of iron oxide oxygen carriers supported on bentonite have been determined by the shrinking core model. Based on the reactivity data, design values of solid circulation rate and solids inventory were determined for the rector. Two types of interconnected fluidized bed systems were designed for CLC application, one system consists of a riser and a bubbling fluidized bed, and the other one has a riser and two bubbling fluidized beds. Solid circulation rates were varied to about $30kg/m^2s$ by aeration into a loop-seal. Solid circulation rate increases with increasing aeration velocity and it increases further with an auxiliary gas flow into the loop-seal. As solid circulation rate is increased, solid hold up in the riser increases. A typical gas leakage from the riser to the fluidized bed is found to be less than 1%.

Effect of $CO_2$ Concentration on Reduction Reactivity of Oxygen Carriers for Chemical-looping Combustor (매체순환식 가스연소기용 산소공여입자들의 환원반응성에 미치는 $CO_2$ 농도의 영향)

  • Ryu, Ho-Jung;Lee, Seung-Yong;Kim, Hong-Ki;Park, Moon-Lee
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.20 no.3
    • /
    • pp.245-255
    • /
    • 2009
  • Effect of CO$_2$ concentration on reduction reactivity of oxygen carrier particles for chemical-looping combustor were investigated. Four particles, NiO/bentonite, OCN601-650, OCN702-1100, OCN702-1250, were used as oxygen carrier particles and two kinds of gases (CH$_4$, 5%, N$_2$ balance and CH$_4$ 5%, CO$_2$ balance) were used as reactants for reduction. For all oxygen carrier particles, higher maximum conversion, reduction rate, oxygen transfer capacity, and oxygen transfer rate were achieved when we used N$_2$ balance gas. OCN601-650 particle showed higher oxygen transfer rate for all gases than other particles, and therefore we selected OCN601-650 particle as the best candidate. For all particles, lower carbon depositions were observed when we used CO$_2$ balance gas.

Reduction Characteristics of Mass Produced Particle for Chemical-Looping Combustor with Different Fuels (매체순환식 가스연소기용 대량생산입자의 연료별 환원반응특성)

  • Ryu, Ho-Jung;Kim, Kyung-Su;Lee, Seung-Yong;Park, Yeong-Seong;Park, Moon-Hee
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.19 no.4
    • /
    • pp.348-358
    • /
    • 2008
  • Reduction reactivity and carbon deposition characteristics of mass produced oxygen carrier particle(OCN-650) have been investigated by using hydrogen, methane, syngas, and natural gas as fuels. For all fuels, the maximum conversion and oxygen transfer capacity increased as the temperature increase. The reduction rate and the oxygen transfer rate increased as the temperature increase for methane. However, those values showed maximum at 900$^{\circ}C$ for hydrogen, syngas, and natural gas. To explain consistently the change of maximum conversion, reduction rate, oxygen transfer capacity, oxygen transfer rate and degree of carbon deposition for different fuels, new parameters such as reactive carbon contents and require oxygen per input gas were adopted.

Basic Design and Sensitivity Analysis of 3 MWth Chemical Looping Combustion System for LNG Combustion and Steam Generation (LNG 연소 및 스팀생산을 위한 3 MWth 급 매체순환연소 시스템의 기본설계 및 민감도 분석)

  • RYU, HO-JUNG;NAM, HYUNGSEOK;HWANG, BYUNG WOOK;KIM, HANA;WON, YOOSEOB;KIM, DAEWOOK;KIM, DONG-WON;LEE, GYU-HWA;BAEK, JEOM-IN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.32 no.5
    • /
    • pp.374-387
    • /
    • 2021
  • Basic design of 3 MWth chemical looping combustion system for LNG combustion and steam generation was conducted based on the mass and energy balance and the previous reactivity test results of oxygen carrier particles. Process configuration including fast fluidized bed (air reactor), loop seal and bubbling fluidized bed (fuel reactor) was confirmed and their dimensions were determined by mass balance. Then, the external fluidized bed heat exchanger (FBHE) was adopted based on the energy balance to extract heat from the system. The optimum reactor design and operating condition was confirmed with sensitivity analysis by modifying system configuration based on the mass and energy balance.

Selection of the Best Oxygen Carrier Particle for Syngas Fueled Chemical-Looping Combustor (합성가스 연소 매체순환식 가스연소기 적용을 위한 최적 산소공여입자 선정)

  • Ryu, Ho-Jung;Kim, Ji-Woong;Jo, Wan-Kuen;Park, Moon-Hee
    • Korean Chemical Engineering Research
    • /
    • v.45 no.5
    • /
    • pp.506-514
    • /
    • 2007
  • To select the best oxygen carrier particle for syngas fueled chemical-looping combustor, the reduction reactivity and carbon deposition characteristics were determined in a thermogravimetric analyzer. Four kinds of oxygen carrier particles (NiO/bentonite, $NiO/LaAl_{11}O_{18}$, $Co_xO_y/CoAl_2O_4$, $NiO/NiAl_2O_4$) were tested with the simulated syngas (30% $H_2$, 10% $CO_2$, 60% CO) as a reduction gas. With each of these particles, the maximum conversion and oxygen transfer capacity increase with increasing the reduction temperature At the given experimental range, the optimum operating temperature to maximize oxygen transfer rate is found to be $900^{\circ}C$ and carbon deposition on the particles could avoid at the temperature above $800^{\circ}C$. Among four kinds of oxygen carrier particles, the NiO-based particles exhibits better reactivity than the CoO-based particle. Moreover, the NiO/bentonite particle produces the best reactivity based on the oxygen transfer rate and the degree of carbon deposition. The measured oxygen transfer rate increases as the metal oxide content in NiO/bentonite particle is increased thereby higher metal oxide contents could provide stable operation of chemical-looping combustor.

Reactivity and Attrition Resistance of Three Oxygen Carrier Particles for Chemical-Looping Combustor (매체순환식 가스연소기 적용을 위한 세 가지 산소공여입자들의 반응성 및 내마모성)

  • Ryu, Ho-Jung;Jin, Gyoung-Tae
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.15 no.3
    • /
    • pp.208-219
    • /
    • 2004
  • To find a suitable oxygen carrier particle for a 50kW chemical-looping combustor, which was designed and installed to demonstrate continuous oxidation and reduction, three oxygen carrier particles(NiO/bentonite, $NiO/NiAl_2O_4$, $CoO_x/CoAl_2O_4$) were prepared. The reactivity and the attrition resistance of particles were measured and investigated by a thermo-gravimetrical analyzer and an attrition test apparatus respectively. From the viewpoints of oxygen transfer capacity, optimum reaction temperature(operating temperature range), reaction rate, carbon deposition rate, and attrition resistance, NiO/bentonite particle showed better performance than the other particles, therefore we selected NiO/bentonite particle as an optimum oxygen carrier particle.

Performance and Economic Analysis of Natural Gas/Syngas Fueled 100 MWth Chemical-Looping Combustion Combined Cycle Plant (천연가스/합성가스 이용 100 MWth 매체순환연소 복합발전 플랜트의 성능 및 경제성 평가)

  • Park, Young Cheol;Lee, Tai-yong;Park, Jaehyeon;Ryu, Ho-Jung
    • Korean Chemical Engineering Research
    • /
    • v.47 no.1
    • /
    • pp.65-71
    • /
    • 2009
  • In this study, performance and economic analysis of natural gas/syngas fueled 100 MWth chemical-looping combustion (CLC) combined cycle plant were performed. Net efficiency of both cases was 53~54%, corresponding to previous research. We used Chemical Engineering Plant Cost Index and Guthrie method to evaluate plant cost. For syngas fueled CLC combined cycle plant, the plant cost was higher since lower heating value(LHV) of syngas was lower than that of natural gas and cost of electricity(COE) was also higher since the cost of syngas was higher than that of natural gas. By sensitivity analysis, it was shown that the cost of syngas should be less than 5.3 $/GJ in order to make COE lower than 5.8 ¢/kWh which was COE of natural gas fueled CLC combined cycle plant.