• Title/Summary/Keyword: 매설조건

Search Result 143, Processing Time 0.028 seconds

Experimental Study on behavior of the Lightweight Air-foamed Soil Considering Freezing-thawing and Soaking Conditions (동결융해 및 수침조건을 고려한 경량기포혼합토의 거동 실험 연구)

  • Kang, Daekyu;Shin, Eunchul
    • Journal of the Korean GEO-environmental Society
    • /
    • v.17 no.5
    • /
    • pp.37-46
    • /
    • 2016
  • In order to determine the variability of environmental characteristics of lightweight air-foamed soil using marine clay according to freezing-thawing and soaking conditions, unconfined compressive strength of the lightweight air-foamed soil samples made by changing the amount of cement under curing conditions of outdoor low temperature, underground or indoor wetting were observed. Compressive strength was not increased under freezing-thawing (temperature range of $-9.1^{\circ}C{\sim}17.2^{\circ}C$) regardless of the amount of cement but the more cement using, it was increased rapidly by underground curing conditions within 30 cm beneath ground level. Therefore, it is necessary to install insulation layer cutting off exterior cold air after construction of lightweight air-foamed soil in condition of freezing-thawing. Bulk density was increased too small under the long-time soaking condition, it tended to decrease rapidly when samples were dried up and had below 6% of water contents. But variability of compressive strength and bulk density was very small for preventing drying and keeping its wet state. The lightweight air-foamed soil that installed beneath ground water level or covered by soil can be evaluated as a long-term reliable construction material.

Threshold Condition for Exclusion of Riprap into Bypass Pipe (저층수 배출관에 유입된 사석의 배제 한계조건)

  • Jeong, Seokil;Lee, Seung Oh
    • Journal of Korean Society of Disaster and Security
    • /
    • v.12 no.1
    • /
    • pp.57-66
    • /
    • 2019
  • One of the most serious problems with concrete small dams or barriers installed in small/median rivers is the deposit of sediments, especially, in Korea. An effective way to discharge such sediments to downstream is to construct a bypass pipe under the river bed. However, efficiency may become lowered if ripraps are entered into the bypass pipe. Therefore, in this study, we derived the threshold condition for the exclusion of ripraps from the bypass pipe using 3D numerical analysis. Upstream flow of the small dam was assumed to be stationary, and the energy concept was applied to the control volume containing the bypass pipe and its periphery. As a result, when the ratio of the water level difference between upstream and downstream to the diameter of the riprap was approximately equal to 1.2, the threshold condition for exclusion of the stones or riprap from the bypass pipe was affirmatively determined. If the characteristics of the adsorptive sediment adversely affecting the river environment in the future would be taken into account, results from this study are expected to put to practical use in the management of concrete small dam with bypass pipe system.

Analysis of Trench Slope Stability in Permafrost Regions According to the Equipment Load (동토 파이프라인 매설공사 시 장비하중에 의한 트렌치 안전성 분석)

  • Kim, Jong-Uk;Kim, Jung-Joo;Lee, Jae-Hyuk;Jafri, Turab H.;Yoo, Han-Kyu
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.3
    • /
    • pp.17-25
    • /
    • 2017
  • Recently, the need of alternate energy resources is increasing due to the global warming issue. The natural gas buried in the extremely cold regions of Alaska and Siberia is of much interest these days. However, the construction standards are needed to be used in extremely cold regions. Particularly, more research work need to be carried out on the trench stability so that the safety of the workers is ensured and the damage to the construction machinery can also be reduced resulting in smaller construction period. In this study, the process for lowering of the pipelines of 30 and 40 in. diameters in the ground conditions (silt and peat) of Yakutsk, Russia was analyzed. The slopes of the ground surface were considered as $0^{\circ}$, $10^{\circ}$, and $20^{\circ}$ to be excavated in summer and winter. The analysis results show that the weight of pipelayer affects the trench stability. Numerical analysis was performed by considering the types of pipelayers, distance between the trench and pipelayer, and the distance between the pipelayers placed longitudinally along the trench. The results show that as the distance between the pipelayer and the trench decreases, the factor of safety of the slope decreases with an increase in the slope of the ground surface. When the slope of the ground surface was $20^{\circ}$, the breakout surface was anticipated to continue from the pipelayer to the trench boundary. In winter season, stability problem of the trench was not observed when the slope of the ground surface was less than $20^{\circ}$.

An Experimental Study on Flow Characteristics Around Culvert According to Blocked Area (차단면적 변화에 따른 암거주변 흐름특성 실험연구)

  • Kim, Sung Joong;Yeo, Hong Koo;Kang, Jun Gu;Jung, Do Joon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.467-467
    • /
    • 2016
  • 암거는 일반적으로 용수나 배수용의 수로가 도로, 철도, 제방 등의 아래에 매설 된 수로를 지칭한다. 이러한 암거는 산업발전으로 사회기반시설의 신설 및 확충, 재정비 등으로 많이 활용되고 있다. 최근 들어 기후로 인한 재해가 급증하면서 이러한 시설물에 대한 안정성 및 관리에 대한 관심이 높아지고 있는 것이 현실이다. 특히 소하천은 집수면적 및 유로연장이 짧고 하상경사가 급하기 때문에 홍수에 취약하다. 즉, 빨라진 유속으로 인해 구조물 주변의 세굴에 의한 유실, 토사유출로 인한 하상퇴적, 부유물로 인한 차단으로 인해 통수에 지장을 받아 피해가 발생하게 된다. 이러한 암거시설물 피해는 2차 피해로 이어질 수 있으며 사회기반시설 파괴로 도시기능이 마비되고 인근 주변지역에 침수로 인한 재산 및 인명피해까지 발생시킬 수 있는 피해 잠재능력을 보유하고 있다. 그러나 피해에 대한 예방대책은 유지관리를 통해 지속적으로 관리하는 것이 대부분의 지침 등에 소개된 내용들이다. 본 연구에서는 암거를 대상으로 암거의 폐색으로 인해 암거주변에서 변화되는 흐름특성을 축소모형을 통해 검토하고자 하였다. 암거 축소모형실험은 1.5m 폭을 갖는 직선수로에서 수행하였으며, 암거모형은 도로암거표준도(2008)를 참조하여 $3m{\times}3m$ 수로암거를 대상으로 1/10 축소모형을 제작하였다. 암거유입부 퇴적으로 인한 암거의 차단률(차단면적/암거단면적)은 차단이 발생하지 않는 0% 조건에서부터 10%, 20%, 30%, 40%, 50% 조건에 대해 실험을 수행하였다. 실험결과 차단에 따른 암거 상류단의 수위는 차단이 없는 암거의 경우에 비해 차단율이 높아질수록 암거유입부 수위는 20.4% ~ 82.7% 상승하는 것으로 나타났다. 암거의 차단률이 40% 이상일 경우 높아진 수위로 인해 암거통로의 윗상면부까지 다다르고 있으며 50%일 경우 암거를 통과하는 흐름이 자유수면흐름이 아닌 오리피스 흐름이 발생하는 것으로 나타났다. 암거유입부 차단으로 인한 암거주변의 최대유속은 암거 직하류부에서 주로 발생하여 암거 유출부에서의 최대유속은 차단율이 증가할수록 선형적으로 증가하는 것으로 나타났으며 암거 유출부에서의 유속은 차단전의 조건(0%) 대비 4.2% ~ 35.5% 까지 상승하는 것으로 나타났다. 이와 같은 결과를 토대로 고려하였을 때 대부분 산지부에서 설치되는 암거의 경우 유속이 불가피하게 증가하게 됨으로 유속에 따른 유속조절방안(차단 및 우회시설) 및 세굴대책을 세워야 할 것으로 판단된다.

  • PDF

The Effects of Sand Compaction by Watering through Field Compaction Test and Numerical Analysis (현장 및 수치해석을 통한 모래 물다짐지반의 다짐효과 연구)

  • Chun, Byungsik;Jang, Younsoo;Kim, Kwanggyu;Park, Dukhyum;Sung, Hwadon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.8 no.6
    • /
    • pp.13-19
    • /
    • 2007
  • This study examines a cause for damage of synthetic resins straight pipe occurred after pipe construction of underground electric power duct pipelines of ${\bigcirc}$ section work, ${\bigcirc}$ line, ${\bigcirc}{\bigcirc}$ city railroad. For this, we analyzed a parameter used for plan and structural analysis through a literature review. And the site condition was analyzed in detail, and test construction of the pipe line that simulated the site pipe line and test on compaction by watering were performed. In addition, an examination on subsurface settlement influence of foundation ground through a structural safety and a numerical analysis of power transmission pipe line was performed. As a result of the performance, relative density gained by compaction by watering was more than average and relative degree of compaction according to technical specification standard showed the result of about 90% in the case of good compaction by watering.

  • PDF

Filling System Analysis for Cavity in Ground using DEM (개별요소해석을 이용한 지반공동부 주입시스템 분석)

  • Han, Jung-Geun;Kim, Young-Ho;You, Seung-Kyong;Chung, Da-Som
    • Journal of the Korean Geosynthetics Society
    • /
    • v.17 no.1
    • /
    • pp.119-126
    • /
    • 2018
  • The ground cavity occurring in the downtown area is on the increase. However, when ground subsidence is occurred or a cavity that causes it to occur is found, time and economic difficulties are follwed in recovery. In advance, this study conducted to develop filling system for reinforcement material which is consist of polymer pouch and admixture as a new filler material. We developed a polymer pouch that is water soluble in the precedent study. Since the filling system is trenchless method and don't need any plant, it has time and economic benefits. This system uses air pressure to filling out cavity in a short time. We estimate this system with respect to filling speed and filling ratio by model experiment. In addition, we could confirm various filling condition using DEM Analysis. So, we could develop filling system and analysis it.

Study on the Between the Grounding Resistance and Grounding Electrode using Mesh Grounding Electrodes and a Shielding Panel (메쉬접지전극과 차폐패넬을 이용한 접지저항 및 접지전극간의 영향에 관한 연구)

  • Leeg, Chung-sik;Cho, Moon-taek;Na, Seung-kwon
    • Journal of Advanced Navigation Technology
    • /
    • v.19 no.3
    • /
    • pp.230-236
    • /
    • 2015
  • In this paper, the electric potential of electrode surface is investigated by assuming them as two dimensional sets of point current sources. And, the simulated water tank is manufactured as a reduced scale of the earth. Henceforth, the adequate model electrode for test is decided to decrease experimental errors relevant to the limitation of the size of the water tank. The one of important things of this work, the deduction method of the potential interference factor is proposed, which used as the criterion of the potential interference according to the shape of conductors and the laying conditions, when multiple grounding conductors are situated at the same resistance grounding area. Also, the validity of this theory is verified from a numerical simulation of the grounding electrode to be used in experiments, and this study is realized by the verified theory and the simulated experiments.

A Study on the Supply and Stray Current Distribution of the DC Railway Power System (직류전기철도 급전시스템에서 공급 및 누설전류 분포에 관한 연구)

  • Cho, Woong-Ki;Choi, Kyu-Hyoung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.160-168
    • /
    • 2010
  • This paper presents the analysis of the current as stray current and supplied current of the substation, on the DC railway power system. In DC railway power supply system, the running rails are usually used as the return conductor(negative-polarity) for traction load current. This condition mainly focuses on economic considerations, since it does not require the installation of an additional return conductor. But, problems of low resistance between the running rails for the return conductor and earth allows a significant part of the return load current to leak into the earth. This current is normally called to as leakage or stary current. This stary currents creates serious problems for any electrified matter in the underground. Therefore, reduction of stray current of the DC railway power supply system is also of direct benefit to the operational and safety aspects of the DC railway systems. In this paper, deal with the analysis of the current distribution on the DC railway power system applied the common grounding system, using SPLIT of CDEGS program.

Analysis of Seismic Response of the Buried Pipeline with Pipe End Conditions (I) (단부 경계조건을 고려한 매설관의 동적응답 해석 (I))

  • Jeong, Jin-Ho;Lee, Byong-Gil;Park, Byung-Ho
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.1148-1158
    • /
    • 2005
  • This work reports results of our study on the dynamic responses of the buried pipelines both along the axial and the transverse directions under various boundary end conditions. We have considered three cases, i.e., the free ends, the fixed ends, and the fixed-free ends. We have studied the seismic responses of the buried pipelines with the various boundary end conditions both along the axial and the transverse direction. We have considered three cases, i.e., the free ends, the fixed ends, and the fixed-free ends for the axial direction, and three more cases including the guided ends, the simply supported ends, and the supported-guided ends for the transverse direction. The buried pipelines are modeled as beams on elastic foundation while the seismic waves as a ground displacement in the form of a sinusoidal wave. The natural frequency and its mode, and the effect of parameters have been interpreted in terms of free vibration. The natural frequency varies most significantly by the soil stiffness and the length of the buried pipelines in the case of free vibration, which increases with increasing soil stiffness and decreases with increasing length of the buried pipeline. Such a behavior appears most prominently along the axial rather than the transverse direction of the buried pipelines. The resulting frequencies and the mode shapes obtained from the free vibration for the various boundary end conditions of the pipelines have been utilized to derive the mathematical formulae for the displacements and the strains along the axial direction, and the displacements and the bending strains along the transverse direction in case of the forced vibration. The negligibly small difference of 6.2% between our result and that of Ogawa et. al. (2001) for the axial strain with a one second period confirms the accuracy of our approach in this study.

  • PDF

Fatigue Evaluation of District Heat Pipes based on the Measured Data (실데이터 분석을 통한 지역난방 열배관의 피로안전성 평가)

  • Park, Jin-Eun;Kyung, Kab-Soo;An, Yong-Mo;Kwon, Soon-Cheol
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.5
    • /
    • pp.569-579
    • /
    • 2011
  • Heating pipes, which are among the main equipment in district heating systems, can be classified into supply and return pipes. Because when the district heating transmission pipe, which is charged with district heating in small to medium-size cities, is under thermal stress during temperature variances in heating water, it suffers from the fatigue phenomenon caused by the thermal stress, according to the number of its service years. District heatingpipes have shown various characteristics according to the operating condition of the service connections, and the irregular temperature variance has had a bad influence on fatigue heating pipes. Therefore, in this study, a field test on laid heating pipes was performed, and the data for each region were analyzed. Also, the fatigue safety of district heating pipes was evaluated via cycle-based evaluation and stress-based evaluation.