• Title/Summary/Keyword: 마찰각

Search Result 782, Processing Time 0.026 seconds

A Study of Characteristic of Friction Angles between Sand and Artificial Rock Interface by Direct Shear Test (직접전단시험에 의한 모래와 인공암석 경계면의 마찰각 특성 연구)

  • Yang, Hong-Suk;Lee, Byok-Kyu;Jang, Seung-Jin;Lee, Su-Gon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.8
    • /
    • pp.65-73
    • /
    • 2012
  • Soil-rock interface, mainly founded in Granite region of Korea, is known as one of the important factor of the slope failure at the rainfall due to smaller shear strength than soil itself. However, research of the effect on slope stability by soil-rock interfaces is insufficient. Therefore, a series of direct shear tests were performed in order to investigate the effect of soil-rock interface on slope stability. The method of tests is to get sand itself and sand-artificial rock interface shear strength from different grain size of sands and artificial rock samples. The results of tests show that the friction angle of interface depends primarily on particle size and surface roughness. Interface friction angle ratio ${\mu}(={\delta}/{\Phi})$ is in the range of 0.75 ~ 0.96, this results indicate that interface friction angle is smaller than sand itself.

Equivalent Friction Angle and Cohesion of the Generalized Hoek-Brown Failure Criterion in terms of Stress Invariants (응력불변량으로 표현한 일반화된 Hoek-Brown 파괴조건식의 등가 마찰각 및 점착력)

  • Lee, Youn-Kyou;Choi, Byung-Hee
    • Tunnel and Underground Space
    • /
    • v.22 no.6
    • /
    • pp.462-470
    • /
    • 2012
  • Implementing the generalized Hoek-Brown failure criterion in the framework of the Mohr-Coulomb criterion requires the calculation of the equivalent friction angle and cohesion. In the conventional method based on the Balmer (1952)'s theory, the tangential instantaneous friction angle and cohesion are expressed in terms of the minimum principal stress ${\sigma}_3$, which does not provide the information about the dependency of the equivalent parameters on the hydrostatic pressure and the stress path. In this study, this defect of the conventional method has been overcome by representing the equivalent parameters in terms of stress invariants. Through the example implementation of the new method, the influence of the magnitude of the hydrostatic pressure and the Lode angle on the tangential instantaneous friction angle and cohesion is investigated. It turns out that the tangential instantaneous friction angle is maximum when the stress condition is triaxial extension, while the tangential cohesion is maximum when the stress condition is triaxial compression. The dependency of the equivalent Mohr-Coulomb strength parameters on the hydrostatic pressure and the Lode angle tends to be more substantial for the favorable rockmass of larger GSI value.

Interface Shear Strength Between Soil and Woven Geotextile (흙-직포간의 접촉면 전단강도 산정)

  • Youn, Choo-Moon;An, Hyun-Ho;Seo, Byoung-Wook;Lee, Seok-Won
    • Journal of the Korean Geosynthetics Society
    • /
    • v.5 no.3
    • /
    • pp.25-30
    • /
    • 2006
  • Large-scale direct shear tests were conducted in order to evaluate both the shear strength of soil itself and the interface shear strength between soil and woven geotextile. Two types of soil (sand and clay) with a woven geotextile were used in the experimental program. Total nine tests were conducted in this study. It has been found from the experimental results that the friction angle of sand itself were $30^{\circ}$. Interface friction angle between woven geotextile and sand showed $26^{\circ}$ indicating an efficiency of 87%. Similarly, interface friction angle between woven geotextile and clay showed $7.7^{\circ}$.

  • PDF

A Study on Comparison of Strength Parameters of Hydrostatic Pressure-Dependent Yield Criteria (정수압에 의존하는 항복기준의 강도정수 비교연구)

  • Lee, Seung-Hyun;Han, Jin-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.529-535
    • /
    • 2016
  • In this theoretical study, the strength parameters of the Drucker-Prager yield criterion and Mohr-Coulomb yield criterion were set to equal values, in order to analyze the correlation among the parameters. The Drucker-Prager strength parameters ${\alpha}$ and k were represented by the Mohr-Coulomb strength parameters c and ${\phi}$. Specifically it can be seen that k is function of c, ${\phi}$ and ${\alpha}$ is function of ${\phi}$ alone. Drucker-Prager strength parameter ${\alpha}$ increases as the internal friction angle of soil increases. ${\alpha}_{av}$ which is the average of ${\alpha}_c$ and ${\alpha}_i$ was proportional to internal friction angle in which ${\alpha}_c$ and ${\alpha}_i$ are ${\alpha}$ values corresponding to the circles of the Drucker-Prager yield cirteria circumscribes and inscribes the Mohr-Coulomb yield criterion respectively. The values of the ${\alpha}_{av}$ was 0.07 and 0.29 which correspond to the internal friction angle of $10^{\circ}$ and $45^{\circ}$ respectively. In addition, value of ${\alpha}_c/{\alpha}_i$ was proportional to internal friction angle of soil and the values of ${\alpha}_c/{\alpha}_i$ 1.12 and 1.62 which corresponds to internal friction angle of $10^{\circ}$ and $45^{\circ}$ respectively.The influence of the Mohr-Coulomb strength parameters on the Drucker-Prager strength parameter k was investigated and it was found that k was mainly influenced by the cohesion of the soil, except in the case of the minimum assumed value of c of 10kPa. The deviator stresses, $S_{c0}$ and $S_{t0}$, which correspond to the cases of the Mohr-Coulomb yield criterion under uniaxial compression and uniaxial tension, respectively, and $S_{0(ave)}$, which is the average value of $S_{c0}$ and $S_{t0}$, decrease as the internal friction angle increases. Furthermore, the hexagon, which represents the Mohr-Coulomb yield locus, becomes more irregular, and the deviations of $S_{c0}$ and $S_{t0}$ from $S_{0(ave)}$ also increase, as the internal friction angle increases.

Interface shear strength between Crushed Stone and Geotextile (쇄석-지오텍스타일간의 접촉면 전단강도 산정)

  • Lee, Seok-Won;Youn, Choo-Moon;An, Hyun-Ho;Seo, Byoung-Wook
    • Journal of the Korean Geosynthetics Society
    • /
    • v.5 no.1
    • /
    • pp.33-38
    • /
    • 2006
  • Large-scale direct shear tests were conducted in order to evaluate both the shear strength of crushed stone itself and the interface shear strength between crushed stone and geotextile. Total three types of geotextile (i.e. one woven geotextile and two nonwoven geotextiles) were used in the experimental program, considering two different values for the unit weight of crushed stone. Total fifteen tests were conducted in this study. It has been found from the experimental results that the friction angles of crushed stone itself were $47^{\circ}$ and $57^{\circ}$ under the unit weights of crushed stone being $1.4t/m^3$ and $1.5t/m^3$, respectively. Interface friction angle between nonwoven geotextile and crushed stone showed $39^{\circ}$ for type A indicating an efficiency of 83% and $42^{\circ}$ for type B indicating an efficiency of 89%. Similarly, interface friction angle between woven geotextile and crushed stone showed $39^{\circ}$ indicating an efficiency of 83%.

  • PDF

Critical State of Crushable Jeju Beach Sand (파쇄성이 큰 제주해사의 한계상태 특성)

  • Lee, Moon Joo;Bae, Kyung Doo;An, Sung Mo;Lee, Woo Jin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.2C
    • /
    • pp.133-140
    • /
    • 2010
  • A series of triaxial test was performed in order to determine critical state parameters of calcareous Jeju sand, which comprises angular shape particles with many pores in the surface. It is observed that Jeju sand mainly shows the contractive behavior during triaxial shear due to high extreme void ratios and large compressibility. The peak friction angle of Jeju sand decreases slightly with increasing mean effective stress due to the particle crushing of carbonate materials. However, the peak friction angle of Jeju sand is higher than that of other silica sands because of the more angular particle shape. The critical state friction angle of Jeju sand gradually decreases when the mean effective stress at a critical state increases. Whereas, there is not a clear influence of void ratio on the critical state friction angle. Critical state parameters of Jeju sand are similar to those of calcareous sands, but significantly larger than those of common sands.

Pullout Test Results of Geosynthetics using Granite Soil and Standard sand (화강토와 표준사를 이용한 토목섬유의 인발시험결과 비교)

  • Ju, Jae-Woo;Park, Jong-Beom;Kim, Jang-Heung;Song, Chun Seok;Baek, Kyung-Jong
    • Journal of the Korean Geosynthetics Society
    • /
    • v.4 no.2
    • /
    • pp.39-45
    • /
    • 2005
  • New concept called the pullout resistance angle has been used to express the friction, cohesion and passive resistance by pullout test at geosynthetics reinforced soil. And also in order to calculate the pullout area, the distribution area method has been used, which is a method of using the curve of tensile force exerted in geogrid. The distribution area ratio showed nearly the same result in the two kind of soils, the granite soil and the standard soil. The pullout resistance angle showed the greater value than friction angle of soil in case of low confining stress of $0.2kg/cm^2$, while it showed the smaller angle than friction of soil in case of high confining stress of $0.8kg/cm^2$.

  • PDF

Evaluation of Interface Shear Properties Between Geosynthetics and Soils Through Inclined Board Tests (경사판 시험을 통한 토목섬유와 흙의 접촉 전단 특성 평가)

  • 서민우;신준수;박준범;박인준
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.6
    • /
    • pp.285-298
    • /
    • 2003
  • Shear properies of geosynthetic/geosynthetic and geosynthetic/soil interfaces which are widely met in landfill sites were evaluated from the inclined board tests. The inclined board testing apparatus is known to reproduce the shear behavior on the low normal stress most accurately. In this study, the friction angle of each interface was estimated and the tensile force mobilized at the geosynthetic was measured as well. The test results showed that the friction angle of each interface and the tensile force of the geosynthetics depended on the amount of normal stress, the type of the geosynthetics used, and the combinations of geosynthetics and soils. In addition, the sand/geotextile/geomembrane interface system was simulated in this study, and it was observed that the tensile force developed at the geomembrane decreased due to the protection effect of the geotextile located above the geomembrane. The test results of this research was compared with those of direct shear tests published, too. Finally, by comparing the measured tensile force of the geosynthetics when the initial displacement of the box occurs, when the slope is called as the critical slope, with suggested analytic solution, the accuracy of analytic solution and the applicability to design were identified.

Evaluation of the Sliding Frictional Characteristics at the Different Loading Mechanisms and Dynamic Stiffness (마찰시험기의 하중부와 방법과 강성 변화에 따른 미끄럼 마찰특성 평가)

  • 윤의성;공호성;권오관;오재응
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1996.04a
    • /
    • pp.108-116
    • /
    • 1996
  • 본 논문에서는 하중부와 방법을 추(dead weight)와 공압(pneumatic)을 이용한 방법에서 스프링을 이용한 방법을 추가하였으며, 압축형 스프링을 선택적으로 사용하여 마찰시험기 수직방향에서의 강성을 큰 변화 폭으로 변화시켰다. 또한 선행된 연구를 통하여 수직하중의 변동량에 크게 영향을 미치는 것으로 알려진 바 있는 디스크 시편의 misaligment 효과를 상사하고 극대화 하기 위하여 본 논문에서는 경사진 디스크 시편을 추가로 사용하였다. 상기조건으로 마찰시험기 시스템의 각 하중부과 방법과 수직강성 변화가 마찰특성에 미치는 영향을 실험적으로 측정 평가하였으며, 마찰시험기 동특성계 모델의 이론적 해석을 통하여 마찰특성 변화를 고찰하였다. 또한, 미끄럼 접촉 시의 수직력과 마찰력을 측정하고, 데이터의 통계적 처리방법에 따른 마찰계수의 변화 특성도 평가하였다.

  • PDF

Bed Load Transport by Waves and Current (파와 해류에 의한 소류사 이동)

  • 유동훈
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.7 no.3
    • /
    • pp.257-264
    • /
    • 1995
  • Various factors are investigated on the bed load transport driven by waves and current, and proper forms of bed load transport formulas mainly used in river hydraulics are chosen for the estimation of combined flow bed load transport after considering the additional factors. The BYO Model is employed for the computation of maximum bed shear stress and mean bed shear stress of the combined flow. The friction factor of uni-directional flow is estimated by using modified Keulegan equation, and equivalent roughness height is determined by obtaining correct answer for the bed shear stress of uni-directional flow. Empirical constant in each bed load formula is determined by applying it to Bijker's laboratory data of bed load transport by waves and current and the formulas obtained are discussed on their final forms with the values of empirical constants.

  • PDF