• Title/Summary/Keyword: 레이저 조사기

Search Result 158, Processing Time 0.034 seconds

THERMAL CHANGE AND MICROHARDNESS IN CURING COMPOSITE RESIN ACCORDING TO VARIOUS CURING LIGHT SYSTEM (광중합기에 따른 복합레진 중합시 온도 변화와 미세경도에 관한 연구)

  • Lee, Dong-Jin;Kim, Dae-Eop;Yang, Yong-Sook;Lee, Kwang-Hee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.3
    • /
    • pp.391-399
    • /
    • 2004
  • The purpose of this study was to compare curing efficiency of newly developed curing units to traditional halogen curing unit by measuring thermal change and surface microhardness according to curing light system. Materials and mathods : The types of curing units were traditional low intensity halogen light(Optilux 360), plasma arc light(Flipo), low heat plasma arc light(Aurys), low intensity LED(Starlight), and high intensity LED(Freelight2). Temperature at the tip of light guide was measured by a digital thermometer using K-type thermocouple. And after resin was filled to 2, 3, 4mm teflon mold, bottom temperature measured during curing. After 24 hours, microhardness of top surface and bottom surface of each resin specimen were measured. Results : The result of this study can be summarized as follows, 1. As measuring temperature of curing unit tips, Flipo is the highest as $52.4^{\circ}C,\;Freelight2(37.86^{\circ}C),\;Optilux360(32.68^{\circ}C),\;Aurys(32.34^{\circ}C),\;and\;Starlight(26.14^{\circ}C)$ were followed. 2. Flipo and Freelight2 were the highest similarly and Optilux360 and Aurys were similarly next and Starlight was lowest in temperature of bottom surface of resin mold. 3. Microhardness of top surface were generally similar, and Aurys was relatively low. 4. Optilux 360 and Freelight2 were the highest, and Flipo, Starlight, and Aurys were followed in microhardness of bottom surface. Conclusions : The results suggest that careful use of Flipo and Freelight2 might be able to cure greater depth of resin composite and do not cause thermal problems than other curing units.

  • PDF

Preparation and Characterization of Reduced Graphene Oxide with Carboxyl Groups-Gold Nanorod Nanocomposite with Improved Photothermal Effect (향상된 광열 효과를 갖는 카르복실화된 환원 그래핀옥사이드-골드나노막대 나노복합체의 제조 및 특성 분석)

  • Lee, Seunghwa;Kim, So Yeon
    • Applied Chemistry for Engineering
    • /
    • v.32 no.3
    • /
    • pp.312-319
    • /
    • 2021
  • Photothermal therapy is a treatment that necrotizes selectively the abnormal cells, in particular cancer cells, which are more vulnerable to heat than normal cells, using the heat generated when irradiating light. In this study, we synthesized a reduced graphene oxide with carboxyl groups (CRGO)-gold nanorod (AuNR) nanocomposite for photothermal treatment. Graphene oxide (GO) was selectively reduced and exfoliated at high temperature to synthesize CRGO, and the length of AuNR was adjusted according to the amount of AgNO3, to synthesize AuNR with a strong absorption peak at 880 nm, as an ideal photothermal agent. It was determined through FT-IR, thermogravimetric and fluorescence analyses that more carboxyl groups were conjugated with CRGO over RGO. In addition, CRGO exhibited excellent stability in aqueous solutions compared to RGO due to the presence of carboxylic acid. The CRGO-AuNR nanocomposites fabricated by electrostatic interaction have an average size of ~317 nm with a narrow size distribution. It was confirmed that under radiation with a near-infrared 880 nm laser which has an excellent tissue transmittance, the photothermal effect of CRGO-AuNR nanocomposites was greater than that of AuNR due to the synergistic effect of the two photothermal agents, CRGO and AuNR. Furthermore, the results of cancer cell toxicity by photothermal effect revealed that CRGO-AuNR nanocomposites showed superb cytotoxic properties. Therefore, the CRGO-AuNR nanocomposites are expected to be applied to the field of anticancer photothermal therapy based on their stable dispersibility and improved photothermal effect.

CdTe 두께에 따른 CdTe/ZnTe 나노구조의 운반자 동역학과 열적 활성화 에너지

  • Han, Won-Il;Lee, Ju-Hyeong;Choe, Jin-Cheol;Lee, Hong-Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.298-299
    • /
    • 2012
  • 현재 반도체 나노구조는 단전자 트랜지스터, 레이저, LED, 적외선 검출기 등과 같은 고효율 광전자 소자에서의 응용을 위해 활발한 연구가 진행 되고 있다. 이러한 응용 분야를 위한 다양한 종류의 나노구조 성장이 광범위하게 시도 되고 있지만 주로 III-V 족 화합물 반도체에 대한 연구가 주를 이룬 반면 II-VI 족 화합물 반도체에 대한 연구는 아직 미흡하다. 하지만 II-VI 족 화합물 반도체는 III-V 족 화합물 반도체와 비교했을 때 더 큰 엑시톤 결합에너지(exciton binding energy)를 가지는 우수한 특성을 보이고 있으며 이러한 성질을 가지는 II-VI 족 화합물 반도체 중에서도 넓은 에너지 갭을 가지는 CdTe 양자점은 녹색 영역대의 광전자 소자로서 활용되고 있다. 본 연구에서는 분자 선속 에피 성장법(molecular beam epitaxy; MBE)과 원자 층 교대 성장법(atomic layer epitaxy; ALE)으로 CdTe 두께에 따른CdTe/ZnTe 나노구조의 광학적 특성을 연구하였다. 광루미네센스(photoluminescence; PL)를 통해 CdTe/ZnTe 나노구조에서 CdTe 두께에 따른 에너지 밴드와 열적 활성화 에너지를 관찰하였다. 또한 시분해 광루미네센스(Time-resolved PL)를 통해 CdTe 두께에 따른 CdTe/ZnTe 나노구조의 운반자 동역학을 조사하였다. 저온 광루미네센스 측정 결과 CdTe 두께가 증가할수록 각 샘플의 피크는 더 낮은 에너지 영역대로 이동하는 것을 관찰할 수 있다. 1.2 에서 2.0 ML로 증가할 때 광 루미네센스의 작은 적색편이를 관찰할 수 있는데, 이는 CdTe 양자우물에서 양자점으로의 구조적인 전이가 일어남에 따라 구속효과가 증가하였기 때문이다. 또한 2.0 에서 3.6 ML까지 CdTe 두께가 증가할 때 측정된 적색편이 현상은 양자점의 사이즈 증가함에 따른 것이다. 마지막으로 3.6 에서 4.4 ML로 CdTe 두께가 증가할 때 큰 적색편이 현상을 볼 수 있는데 이는 CdTe 양자점에서 양자세선으로의 구조적 전이에 따라 구속효과가 증가하였기 때문이다. 온도 의존 광루미네센스(Temperature-dependent PL) 측정 결과 1.2 와 3.0 ML 두께의 CdTe/ZnTe 나노구조에서 구속된 전자의 열적 활성화 에너지가 18 과 35 meV로 관찰되었다. 3.0 ML CdTe/ZnTe 나노구조에서 가장 큰 열적 활성화 에너지를 갖는 것은 양자점의 균일도가 좋아지고 저차원 나노구조로의 구조적 전이가 일어나면서 운반자 구속효과에 다른 쿨롱 상호작용이 증가하였기 때문이다.

  • PDF

VLSI 설계와 CAD 기술개발 연구 전략 -다음 세대 컴퓨터 개발을 위한-

  • 이문기
    • The Magazine of the IEIE
    • /
    • v.11 no.5
    • /
    • pp.42-50
    • /
    • 1984
  • 국내의 다음세대 컴퓨터 개발을 위한 VLSI 설계와 CAD 분야에 대한 연구 방향을 제시한다. 연구의 목표는 국제적으로 경쟁할 수 있는 VLSI 설계능력과 백만개 정도의 트랜지스터로 자성된 회로를 경제적으로 설계하기 위한 CAD 기술과 System의 확립이다. ·새로운 회로 구조와 알고리즘에 대한 연구 · CAD 도구와 언어의 개발에 관한 첨단 CAD 기술개발연구 · VLSI 설계에 필요한 CAD 도구 이용과 개발에 필요한 표준 인터페이스, 네트워킹, 컴퓨팅 하드웨어. 시스템 소프트웨어에 대한 연구등의 부분으로 크게 나눌 수 있다. 이용 가능한 CAD system을 평가하고 개선하며 첨단 CAD에 대한 소프트웨어와 하드웨어에 대해 · 컴퓨팅 하드웨어 · 프로그램 분위기 · 네트워킹 능력 ·자료 교환을 위한 표준인터페이스 등에 관해 조사분석도 병행한다. CAD에 관한 세부적인 연구 과제는 · 시스템 사양언어 · 설계 검증 ·시스템시뮬레이션· 설계 합성 · 설계 해석· 설계 방법론·디바이스와 공정 모델링 프로그램 등이다. 고속 계산용 VLSI에 관한 구조와 알고리즘은 행렬 계산을 위한 ·분산 배열 처리 회로 ·시스토릭 (Systolic) 배열 회로 ·셀률라(Cellular) 논리 회로 · 3차원 배열 회로 와 · 비규칙적 계산 알고리즘을 갖는 VLSI가 있다. VLSI설계훈련과 CAD 기술 축적을 위해 CAD enter를 설립하여 전국적인 CAD 네트워킹을 관계 연구소와 여러 대학에 가설하며, MPC 계획을 추진한다. VLSI설계 가능성이 입증되면 VLSI 설계능력을 더욱 향상 시키기 위해 0.5∼1.0mm기술의 silicon faundary를 설립한다. 연구 개발 조직은 대학, 산업체. 연구소가 삼위일체가 되어 수행될 수 있도록 연구 개발 위원회를 설치 운영하며 경쟁적이며 경제적으로 연구 업무를 집행하는 것이 바람직하다.았다.형질에 관여하는 귀전자에 미치는 기구에 대하여 검토할 여타가 있다고 보여진다. 분해능의 특징으로 미루어 앞으로는 레이저를 이용한 계측 방법이 그 주류를 이룰 것으로 사료된다. 우선 본 해설은 기체의 온도 및 농도의 광학적 측정방법중 Raman산란광 검출법에 대하여 실제로 측정하는 입장에서 간단히 소개한다.lity)이, 높은 $GA_3$함량에 기인된다'는 주장은 본실험(本實驗)으로 부인(否認)되었다. 따라서, 응용학적(應用學的) 측면에서 고려해 볼 때, 리베스식물(植物)의 육종기간 단축을 위한 모든 화아분화(花芽分化) 촉진 조치는 P.J.-식물(植物)이 20. node이상 생육하였을 때 취하는 것이 효율적인 것으로 결론 지어진다.앞당겨진 7月 셋째 週였다. 8. Culex (Culex) tritaeniorhynchus summoro년의 最大發生 peak는 1981年, 1982年 모두 8月 둘째 週였다. 9. Anopheles (Anopheles) sinensis의 最大發生 peak는 1981年에 7月 다섯째 週, 1982年은 2週 앞당겨진 7月 셋째 週였다. 10. 重要 3種의 最大 peak를 比城하면 Culex (Culex) pipiens pallens와 Anopheles (Anopheles) sinensis는 1981年과 1982年 모두 最大 peak時期가 同一하였으며, Culex (Culex) tritaeniorhynchus summoro년는 2年間 모두 8月둘째 週에 나타났다.osterior to manubrium and anterior to aortic arch) replacing the normal mediastinal fat. (2) In benign thymoma, the marging of the mass was smooth and the normal fat

  • PDF

Size Distribution of Suspended Particulate Materials in the Southern East Sea of Korea (한국 동해 남부 해역의 부유물질의 입도분포에 관한 연구)

  • Park, Yong Ahn;Kim, Kyung-Ryul;Choi, Jin Yong;Park, Soo Chul
    • 한국해양학회지
    • /
    • v.23 no.2
    • /
    • pp.76-88
    • /
    • 1988
  • Size distribution of suspended particulate materials (SPM) in the coastal waters of eastern Korea was studied using a laser particle size analyzer. Mean particle size (MPS) ranges from 3.69 to 8.40 ${\mu}m$ in surface waters, from 3.38 to 6.43 ${\mu}m$ in mid-depth waters, and from 3.88 to 8.30 ${\mu}m$ in near-bottom waters. For smaller MPS, the size distribution is unimodal, whereas it becomes polymodal as the MPS increases. Particle concentrations increased with the increases in MPS, suggesting that processes of adding larger particles in the waters such as resuspension of bottom sediments are more important in controlling MPS in the area than processes of removing smaller particles such as flocculation of fine particles. Observations of higher MPS near the coast in mid-depth waters, and at the continental slope in near-bottom waters appear to support the above idea. For surface waters with high MPS, mean particle density was noticably low, indicating the importance of biological activities in the formation of suspended particles.

  • PDF

Methylene Blue Photodegradation Properties of Anatase/brookite Hybrid TiO2 Photocatalyst Prepared with Different Acid Catalysts (산 촉매에 따른 아나타제/브루카이트 혼성형 TiO2 광촉매의 메틸렌블루 광분해특성)

  • Yun, Seok-Min;Kim, Jinhoon;Jeong, Euigyung;Im, Ji Sun;Lee, Young-Seak
    • Applied Chemistry for Engineering
    • /
    • v.22 no.1
    • /
    • pp.21-25
    • /
    • 2011
  • In this study, anatase/brookite hybrid $TiO_2$ was prepared using different acid catalysts and microwave to improve photodegradation of organic pollutants. The methylene blue photodegradation properties of the prepared photocatalysts with different particle/crystal size and brookite fractions were investigated. Surface characteristics and particle sizes of anatase/brookite hybrid $TiO_2$ were evaluated using scanning electron microscopy (SEM) and laser diffraction particle size analyzer, respectively and crystal structures were investigated with X-ray diffraction (XRD). Methylene blue photodegradation properties were evaluated with UV-vis spectrophotometer. Anatase and anatase/brookite hybrid $TiO_2$ had less than 500 nm size of clusters and the average particle size of $6.66{\sim}6.85{\mu}m$, suggesting that types of acid catalysts did not affect the size. XRD of the prepared $TiO_2$ showed that the photocatalysts had anatase/brookite hybrid crystal structure and applying microwave did not change their crystal structure. Photodegradation of methylene blue with the prepared photocatalyst did not increased proportionally to the fraction of brookite and the crystal size and decreased when brookite fraction and the crystal size increased further. Anatase/brookite hybrid $TiO_2$ with brookite fraction of 9.4% and crystal size of 4.53 nm shows the best photodegradation activity of methylene blue.

IN VITRO COMPARISON OF VARIOUS DIAGNOSTIC METHODS OF OCCLUSAL CAR10US LESIONS (교합면 우식병소의 다양한 진단법에 관한 비교연구)

  • Kim, Jae-Gon;Kim, Young-Jin;Kim, Young-Sin;Baik, Byeong-Ju
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.4
    • /
    • pp.613-619
    • /
    • 2001
  • The aims of this study were to compare the accuracy, sensitivity and specificity of cnventional visual examination, radiography and a new laser fluorescence method, KaVo Diagnodent, for the detection of occlusal caries lesions. One hundred sound human premolars and molars which had no restorations or interproximal cavities were tested by three methods. Tooth lesions depth was assessed at histologic examination using Caries detector dye The following results were obtained. 1. Diagnodent show 7.8 in sound tooth, 25.4 in initial caries, 30.5 in enamel caries, and 53.8 in dentin caries with average score 2. Spearman and Pearson relation coefficient was high between tooth-specimen test with dye and Diagnodent(0.736, 0.619), visual examination(0.664, 0.666), and was low between tooth-specimen test with dye and radiographic examination(P<0.01, total) 3. Accuracy of occlusal caries was highest on Diagnodent(65%) and lowest on radiographic examination(35%) 4. In initial caries, the sensitivity and specificity of Diagnodent method was the highest. In enamel caries, the sensitivity of visual examination was the highest and specificity of Diagnodent method was the highest. In dentinal caries, the sensitivity and specificity of Diagnodent method was the highest and sensitivity of visual examination was the lowest.

  • PDF

On-line Image Guided Radiation Therapy using Cone-Beam CT (CBCT) (콘빔CT (CBCT)를 이용한 온라인 영상유도방사선치료 (On-line Image Guided Radiation Therapy))

  • Bak, Jin-O;Jeong, Kyoung-Keun;Keum, Ki-Chang;Park, Suk-Won
    • Radiation Oncology Journal
    • /
    • v.24 no.4
    • /
    • pp.294-299
    • /
    • 2006
  • $\underline{Purpose}$: Using cone beam CT, we can compare the position of the patients at the simulation and the treatment. In on-line image guided radiation therapy, one can utilize this compared data and correct the patient position before treatments. Using cone beam CT, we investigated the errors induced by setting up the patients when use only the markings on the patients' skin. $\underline{Materials\;and\;Methods}$: We obtained the data of three patients that received radiation therapy at the Department of Radiation Oncology in Chung-Ang University during August 2006 and October 2006. Just as normal radiation therapy, patients were aligned on the treatment couch after the simulation and treatment planning. Patients were aligned with lasers according to the marking on the skin that were marked at the simulation time and then cone beam CTs were obtained. Cone beam CTs were fused and compared with simulation CTs and the displacement vectors were calculated. Treatment couches were adjusted according to the displacement vector before treatments. After the treatment, positions were verified with kV X-ray (OBI system). $\underline{Results}$: In the case of head and neck patients, the average sizes of the setup error vectors, given by the cone beam CT, were 0.19 cm for the patient A and 0.18 cm for the patient B. The standard deviations were 0.15 cm and 0.21 cm, each. On the other hand, in the case of the pelvis patient, the average and the standard deviation were 0.37 cm and 0.1 cm. $\underline{Conclusion}$: Through the on-line IGRT using cone beam CT, we could correct the setup errors that could occur in the conventional radiotherapy. The importance of the on-line IGRT should be emphasized in the case of 3D conformal therapy and intensity-modulated radiotherapy, which have complex target shapes and steep dose gradients.