• Title/Summary/Keyword: 레이저 조사기

Search Result 158, Processing Time 0.023 seconds

A Clinical Study on the Effects of Extravascular Laser System on Osgood-Schlatter Disease (비침습 레이저 조사기를 이용한 Osgood-Schlatter's disease의 치료 증례보고)

  • Suk, Yun Hee;Min, Sang Yeon;Kim, Jang Hyun
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.26 no.4
    • /
    • pp.77-83
    • /
    • 2012
  • Objectives: The purpose of this study was to assess the effect of Extravascular Laser System on Osgood-Schlatter Disease Methods: In this study, we treated the 6 cases of children who were diagnosed with Osgood-Schlatter disease with Extravascular Laser System. 4 of them were treated with acupuncture as well, the other 2 were given with combined acupuncture and Blood-pricking Treatment. For evaluation, 6 children explained the degree of pain relief by comparing with degree of pain before treatment. Results: Extravascular Laser System for Osgood-Schlatter Disease resulted in a significant decline in the subjective pain degree. All of them were almost cured. The average treatment times was 6.7 times, and the average treatment period was 26.7days. Conclusions We report the good result of the efficacy of extravascular laser system on Osgood-Schlatter Desease. Cases in this study, however, were small in number. Therefore more study is required.

The case report on pain treatment by extravascular laser system (비침습 레이저 조사기를 이용한 통증 치료에 대한 증례 보고)

  • Hwang, Young-Jun;Kim, Jang-Hyun
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.20 no.3
    • /
    • pp.51-60
    • /
    • 2006
  • Objectives : The purpose of this study was to assess the ability of Extravascular Laser System on pain treatment. Methods : On this study, we carried out with the 9 cases of children who visited in the Department of Pediatrics, OO University Oriental Hospital as pain. 9 children suffering from pain were treated with Extravascular Laser System, and two of these were treated with combined acupuncture. In order to determine the degree of pain relief, a visual analogue scale was used. Results : Extravascular Laser System for pain resulted in a significant decline in the visual analogue scale. For Extravascular Laser System combined with acupuncture, VAS score has fallen by 30% each time compared to 17.5% of Extravascular Laser System only. In 2 cases of chronic pain, VAS score decreased to 0. In 7 cases of acute pain, All of 7 children improved 50% on VAS score, On average VAS score have seen 79.2% reduction. The average treatment times of chronic pain were 5 times, while that of acute pain were 4.1 times. Conclusions : We report the good result of the efficacy of extravascular laser system on children's pain. but, this study's cases were small in number. so more study is need.

  • PDF

Development of Automatic Sorting System for Black Plastics Using Laser Induced Breakdown Spectroscopy (LIBS) (LIBS를 이용한 흑색 플라스틱의 자동선별 시스템 개발)

  • Park, Eun Kyu;Jung, Bam Bit;Choi, Woo Zin;Oh, Sung Kwun
    • Resources Recycling
    • /
    • v.26 no.6
    • /
    • pp.73-83
    • /
    • 2017
  • Used small household appliances have a wide variety of product types and component materials, and contain high percentage of black plastics. However, they are not being recycled efficiently as conventional sensors such as near-infrared ray (NIR), etc. are not able to detect black plastic by types. In the present study, an automatic sorting system was developed based on laser-induced breakdown spectroscopy (LIBS) to promote the recycling of waste plastics. The system we developed mainly consists of sample feeder, automatic position recognition system, LIBS device, separator and control unit. By applying laser pulse on the target sample, characteristic spectral data can be obtained and analyzed by using CCD detectors. The obtained data was then treated by using a classifier, which was developed based on artificial intelligent algorithm. The separation tests on waste plastics also were carried out by using a lab-scale automatic sorting system and the test results will be discussed. The classification rate of the radial basis neural network (RBFNNs) classifier developed in this study was about > 97%. The recognition rate of the black plastic by types with the automatic sorting system was more than 94.0% and the sorting efficiency was more than 80.0%. Automatic sorting system based on LIBS technology is in its infant stage and it has a high potential for utilization in and outside Korea due to its excellent economic efficiency.

Tensile Bond Strength of Composite Resin Treated with Er:YAG Laser (Er:YAG 레이저를 활용한 와동형성시 컴포짓 결합강도)

  • Shin, Min;Ji, Young-Duk;Rhu, Sung-Ho;Cho, Jin-Hyoung
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.2
    • /
    • pp.269-276
    • /
    • 2005
  • This in vitro study evaluated the influence of a flowable composite resin on the tensile bond strength of resin to enamel and dentin treated with Er:YAG laser and diamond bur. 96 Buccal enamel and mid-coronal dentin were laser-irradiated using an Er:YAG laser and treated with diamond bur. Each groups(48) were divided two small groups depends on acid-etching procedure. Light-cure flowable resin(Metafil Flo) and self-cure resin(Clearfil FII New Bond) were used in this study. After surface etching with 37% phosphoric acid and the application of an adhesive system, specimens were prepared with a hybrid composite resin. After 24hours storage in distilled water at 37$^{\circ}C$, all samples were submitted to the tensile bond strength evaluation, using a universal testing machine(Z020, Zwick, Germany). The obtained results were as follows: 1. TBS of acid-etching group were higher than those of non-etching group in both enamel and dentin treated with Er:YAG laser and diamond bur. Laser 'conditioning' was clearly less effective than acid-etching. Moreover, acid etching lased enamel and dentin significantly improved the microTBS of M-Flo. 2. In enamel, TBS of laser-irradiated group were lower than those of bur-prepared group. However, in flowable resin subgroup, there were not differed those between two groups in dentin. 3. In laser-treated group, TBS of flowable composite resin were higher than those of self-curing resin in dentin, however, there was no difference in enamel. From this study, we can conclude that the self- and light-cure composite resin bonded significantly less effective to lased than to bur-cut enamel and dentin, and that acid-etch procedure remains mandatory even after laser ablation. We suggest that Er:YAG laser was useful for preparing dentin cavity with flowable resin filling.

The effect of using laser for ceramic bracket bonding of porcelain surfaces (세라믹 브라켓 부착 시 레이저를 이용한 포세린 표면처리 효과)

  • An, Kyung-Mi;Sohn, Dong-Seok
    • The korean journal of orthodontics
    • /
    • v.38 no.4
    • /
    • pp.275-282
    • /
    • 2008
  • Objective: The purpose of this study was to investigate the effect of using laser for ceramic bracket bonding of porcelain surfaces and to compare it with conventional treatment of porcelain surfaces. Methods: Ninety feldspathic porcelain specimens were divided into 9 groups of 10, with each group having different surface treatments performed. Surface treatment groups were orthophosphoric acid, orthophosphoric acid with silane, hydrofluoric acid, hydrofluoric acid with silane, sandblasted, sandblasted with silane, laser etched, laser etched with silane, and glazed surface served as a control group. In the laser etched groups, the specimens were irradiated with 2-watt superpulse carbon dioxide ($CO_2$) laser for 20 seconds. Ceramic brackets were bonded with light-cure composite resin and all specimens were stored in water at $37^{\circ}C$ for 24 hours. Shear bond strength was determined in megapascals (MPa) by shear test at 1 mm/minute crosshead speed and the failure pattern was assessed. For statistical analysis, one-way ANOVA and tukey test were used. Results: Statistical analysis showed significant differences between the groups. The HFA + S group showed the highest mean shear bond strength ($13.92{\pm}1.94\;MPa$). This was followed by SB + S ($10.16\;{\pm}\;1.27\;MPa$), HFA ($10.09\;{\pm}\;1.07\;MPa$), L + S ($8.25\;{\pm}\;1.24\;MPa$), L ($7.86\;{\pm}\;0.96\;MPa$), OFA + S ($7.22\;{\pm}\;1.09\;MPa$), SB ($3.41\;{\pm}\;0.37\;MPa$), OFA ($2.81\;{\pm}\;0.37\;MPa$), G ($2.46\;{\pm}\;1.36\;MPa$), Bond failure patterns of HFA and silane groups, except L + S, were cohesive modes in porcelain while adhesive failure was observed in the control group and the rest of the groups. Conclusions : A 2-watt superpulse $CO_2$ laser etching of porcelain surfaces can provide a satisfactory result for porcelain surface treatment for ceramic bracket bonding. Laser irradiation may be an alternative conditioning method for the treatment of porcelain surfaces.

In vivo Imaging Flow Cytometer (세포 이미징 기능을 겸비한 생체 유세포 분석기)

  • Lee, Ho
    • Journal of the Korean Society of Visualization
    • /
    • v.5 no.1
    • /
    • pp.9-11
    • /
    • 2007
  • We introduce an in vivo imaging flow cytometer, which provides fluorescence images simultaneously with quantitative information on the cell population of interest in a live animal. As fluorescent cells pass through the slit of light focused across a blood vessel, the excited fluorescence is confocally detected. This cell signal triggers a strobe beam and a high sensitivity CCD camera that captures a snap-shot image of the cell as it moves down-stream from the slit. We demonstrate that the majority of signal peaks detected in the in vivo flow cytometer arise from individual cells. The instrument's capability to image circulating T cells and measure their speed in the blood vessel in real time in vivo is demonstrated. The cell signal irradiance variation, clustering percentage, and potential applications in biology and medicine are discussed.

Evaluation of the Positional Accuracy of the Delivered Beams from the Target: A Phantom Study (방사선 치료에서 치료 표적과 조사 빔의 일치 정도 평가: 팬텀 연구)

  • Kang, Sei-Kwon;Cho, Byung-Chul;Cheong, Kwang-Ho;Ju, Ra-Hyeong;Kim, Su-Ssan;Kim, Kyoung-Ju;Choi, Sang-Gyu;Bae, Hoon-Sik;Lee, Re-Na;Oh, Do-Hoon
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.192-200
    • /
    • 2006
  • We evaluated the positional accuracy of the delivered beams to the target in a phantom by simulating the whole process of the radiation treatments Including CT scanning, planning and beam exposures with MLCs. For this purpose, a phantom was made to calibrate the alignment between the CT and the attached laser system. A new, convenient method was also devised to align the setup lasers in the treatment room. Film was used for the Identification of the delivered beam and analyzed with a homemade computer program. The positional differences between the target and the beam centers varied with the couch rotations. The accelerator we used showed a maximum discrepancy of 2.0 mm at the table angle of $295^{\circ}$. The same measurements based on the new isocenter from the Winston-Lutz test resulted in the maximum of 1.35 mm for all rotation angles. The evaluation of the differences between the target and the beam centers is useful for the treatment planning.

  • PDF

A Study on the Superelevation Measuring Accuracy using GPS-lNS Integrated System (GPS-INS 통합시스템을 이용한 도로의 편경사 측정 정확도 연구)

  • Jeong, Dong-Hun;Yun, Deok-Geun;Seong, Jeong-Gon
    • Journal of Korean Society of Transportation
    • /
    • v.24 no.2 s.88
    • /
    • pp.79-89
    • /
    • 2006
  • The purpose of this study is to propose a new method using the GPS-INS integrated system which measures the superelevation of a curved yoad rapidly and safely Also, using the CPS-INS integrated system. this Paper is to analyze the expected accuracy of the superelevation on the roads which are already opened for traffic. The superelevation of the roads which are already opened for traffic often changes by roads rehabilitation work such as resurfacing of Pavement and rutting However, it is difficult to measure 1,he changes of road geometry because or the high cost and the safety problem. If the measurement of superelevation using GPS-INS integrated system is used instead of existing conventional surveying method, the superelevation of road is expected to be measured accurately(under 0.4% RMSE) just by driving without interfering the traffic Therefore, the application of the GPS-INS integrated system is expected to be useful tool for measuring the superelevation of the roads.

Coupling Intensity Effects in Ladder-type Electromagnetically Induced Transparency of Rb atoms (결합광 세기에 따른 Rb 원자의 사다리형 전자기 유도 투과)

  • Moon, H.S.;Lee, L.;Kim, J.B.
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.1
    • /
    • pp.1-6
    • /
    • 2005
  • We have studied the polarization effects and the coupling intensity effects of electromagnetically induced transparency(EIT) in the 5S$_{1}$2-/5P$_{3}$2-/5D$_{5}$2/ ladder system of Rb. We obtained the EIT spectrum with the hyperfine structure of 5D$_{5}$2/ transitions and the minimal width of the measured EIT spectrum was 6.5 MHz. We observed the change of the relative magnitudes of the hyperfine structure of EIT according to not only the polarizations of lasers but also the intensity of the coupling laser. The cause of the coupling intensity effects is that the EIT signal nonlinearly increases to the coupling intensity.

Nonlinear Magneto-optic Effect in the Paraffin Coated Rb Vapor Cell (파라핀이 코팅된 Rb 증기 셀에서 비선형 광자기 효과 신호)

  • Lee, Hyun-Joon;Yu, Ye-Jin;Bae, In-Ho;Moon, Han-Seb
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.4
    • /
    • pp.249-254
    • /
    • 2009
  • In our study, the Hanle spectrum and nonlinear magneto-optic effect (NMOE) signals were observed as a function of magnetic field on $D_1$ line of $^{87}Rb$ atoms contained in a paraffin coated vapor cell. We observed the double structure from the Hanle and the NMOE spectrum in the paraffin coated Rb vapor cell. The narrow spectral width of the narrow resonance signal is approximately 1 kHz and the magnitude is approximately 10 percent of the total spectrum. Also, the NMOE signals corresponding to the Hanle configuration consisted of two different dispersion-like features. At the near zero magnetic field, a sharp slope signal was centered, and its value was 10 mV/${\mu}T$ with laser power was $200{\mu}W$.