• Title/Summary/Keyword: 라이스

Search Result 415, Processing Time 0.031 seconds

When Evaluated Using CT Imaging Phantoms AAPM Phantom Studies on the Quantitative Analysis Method (AAPM Phantom을 이용한 CT 팬텀 영상 평가 시 정량적 분석 방법에 관한 연구)

  • Kim, Young-Su;Ye, Soo-Young;Kim, Dong-Hyun
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.8
    • /
    • pp.592-600
    • /
    • 2016
  • AAPM CT performance for special medical equipment quality control checks using a standard phantom for evaluation, using the evaluator's subjective assessment as to minimize errors due computerized assessment program to evaluate their usefulness. Phantom for evaluation AAPM CT Performance Phantom: was used, the default shooting conditions are the same as quality control checks. And, we use IMAGE J to evaluate the program. Quantitative evaluation with CT attenuation coefficient and the noise measurement, the uniformity measurement, the slice thickness measurement, contrast resolution of the measurement, a phantom image of the spatial resolution determined by the evaluation program is evaluated as self-extracting the result after processing the image, CT uniformity measurement for the evaluation that was smaller and the standard deviation of a video image processing more uniform slice thickness measurements it is difficult to evaluate due to the difference of the ratio of the measured value of the phantom image. Contrast resolution was measured cylindrical diameter 6th evaluate the shape of a circle obtained a mean value and a standard deviation of diameters, the spatial resolution of the group of source, including acceptance criteria automatically extracted result as a result of both the number of the extracted circularIt appeared. Evaluate the source image and video processing, and video to qualitative evaluation by gross were processed video image is shown excellent results. If the evaluators in order to minimize the errors of subjective judgment based on the results of the above should be done with a quantitative evaluation and qualitative evaluation utilizes a computerized assessment program is considered that further evaluation be made more efficient.

Dose Measurements using Phantoms for Tube Voltage, Tube Current, Slice Thickness in MDCT (MDCT의 관전압, 관전류, 슬라이스 두께 변화에 따른 팬텀의 선량 분포 측정)

  • Lee, Chang-Lae;Jeon, Seong-Su;Nam, So-Ra;Cho, Hyo-Min;Jung, Ji-Young;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.139-143
    • /
    • 2007
  • The purpose of this study was to measure and evaluate radiation dose for MDCT parameters. Patient dose for various combination of MDCT parameters were experimentally measured, using MDCT (GE light speed plus 4 slice, USA), model 2026C electrometer (RADICAL 2026C, USA), standard Polymethylmethacrylate (PMMA) head and body CT dosimetry phantoms. In clinical situations, for a typical abdominal scan performed with MDCT at 120 kVp, 180 mAs, 20 mm collimation, and a pitch of 0.75 $CTDI_w,\;CTDI_{vol}$ were measured as 20.2 mGy, 26.9 mGy, respectively. When scan length is assumed as 271.3 mm, DLP and measured effective dose of the abdominal would be calculated as $729.1\;mGy{\cdot}cm$, 10.9 mSv, respectively.

  • PDF

Clinical Results of Arthroscopic Salvage Repair including Popliteus Tendon as a Post for Complex Lateral Meniscus Tear (복합성 외측 반월상 연골판 파열에서 슬와건을 한시적 지주로 시행한 구제적 성격의 관절경 봉합술의 임상 결과)

  • Park, Sang-Eun;Kim, Sang-Kil
    • Journal of the Korean Arthroscopy Society
    • /
    • v.14 no.1
    • /
    • pp.1-6
    • /
    • 2010
  • This study was undertaken to document the clinical results and technical aspects of arthroscopic repair including popliteus tendon as a post for the treatment of complex lateral meniscus in young people indicated as total meniscectomy. From June 2004 to May 2006, we prospectively studied arthroscopic repairs on 32 young people knees with symptomatic complex lateral meniscus that was treated by all inside repair technique using Popliteus tendon as a post. Clinical results were evaluated using Lysholm knee scores preoperatively and at final follow-up. 2nd look arthroscopy or MRI was taken at final follow-up. 80% of patients carried out MRI or 2nd look arthroscopy under permission. Most patients who follow up were able to return to their previous life activities with little or no limitation, and no reoperation was required after an average follow-up of 42.8 months. Mean Lysholm knee scores improved from 65.4 (range, 55 to 75) preoperatively to 93.9 (range, 79 to 100) at the final follow-up (P<.001). 80% meniscus healing was found on arthroscopic or MRI follow up. Conclusively, arthroscopic repair using Popliteus tendon as a post is effective for treating young people with complex lateral meniscus tear as a salvage procedure.

  • PDF

Improved Bi-directional Symmetric Prediction Encoding Method for Enhanced Coding Efficiency of B Slices (B 슬라이스의 압축 효율 향상을 위한 개선된 양방향 대칭 예측 부호화 방법)

  • Jung, Bong-Soo;Won, Kwan-Hyun;Jeon, Byeung-Woo
    • Journal of Broadcast Engineering
    • /
    • v.14 no.1
    • /
    • pp.59-69
    • /
    • 2009
  • A bi-directional symmetric prediction technique has been developed to improve coding efficiency of B-slice and to reduce the computational complexity required to estimate two motion vectors. On the contrary to the conventional bi-directional mode which encodes both forward and backward motion vectors, it only encodes a single forward motion vector, and the missing backward motion vector is derived in a symmetric way from the forward motion vector using temporal distance between forward/backward reference frames to and from the current B picture. Since the backward motion vector is derived from the forward motion vector, it can halve the computational complexity for motion estimation, and also reduces motion vector data to encode. This technique always derives the backward motion vector from the forward motion vector, however, there are cases when the forward motion vector is better to be derived from the backward motion vector especially in scene changes. In this paper, we generalize the idea of the symmetric coding with forward motion vector coding, and propose a new symmetric coding with backward motion vector coding and adaptive selection between the conventional symmetric mode and the proposed symmetric mode based on rate-distortion optimization.

Pre-Packing, Early Fixation, and Multi-Layer Density Analysis in Analytic Placement for FPGAs (FPGA를 위한 분석적 배치에서 사전 패킹, 조기 배치 고정 및 밀도 분석 다층화)

  • Kim, Kyosun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.10
    • /
    • pp.96-106
    • /
    • 2014
  • Previous academic research on FPGA tools has relied on simple imaginary models for the targeting architecture. As the first step to overcome such restriction, the issues on analytic placement and legalization which are applied to commercial FPGAs have been brought up, and several techniques to remedy them are presented, and evaluated. First of all, the center of gravity of the placed cells may be far displaced from the center of the chip during analytic placement. A function is proposed to be added to the objective function for minimizing this displacement. And then, the density map is expanded into multiple layers to accurately calculate the density distribution for each of the cell types. Early fixation is also proposed for the memory blocks which can be placed at limited sites in small numbers. Since two flip-flops share control pins in a slice, a compatibility constraint is introduced during legalization. Pre-packing compatible flip-flops is proposed as a proactive step. The proposed techniques are implemented on the K-FPGA fabric evaluation framework in which commercial architectures can be precisely modeled, and modified for enhancement, and validated on twelve industrial strength examples. The placement results show that the proposed techniques have reduced the wire length by 22%, and the slice usage by 5% on average. This research is expected to be a development basis of the optimization CAD tools for new as well as the state-of-the-art FPGA architectures.

Effects of Antioxidative Activities and Antibrowning of Extracts from Onion, Apple and Mandarin Orange Peel as Natural Antibrowning Agents (천연 갈변 억제제 개발을 위한 양파, 사과 및 감귤 과피 추출물의 항산화 및 갈변 저해 효과)

  • Chang, Min-Sun;An, Se-Jin;Jeong, Moon-Cheol;Kim, Dong-Man;Kim, Gun-Hee
    • The Korean Journal of Food And Nutrition
    • /
    • v.24 no.3
    • /
    • pp.406-413
    • /
    • 2011
  • This study was carried out to investigate antioxidative properties of various extracts and antibrowning effects of extracts in apple slices were investigated by ${\Delta}E$ value and PPO relative activity. Apples were cut into 1.5 cm thickness and they were dipped in 1% extract solutions(OW: water extracts of onion, OE: 80% EtOH extracts of onion, AW: water extracts of apple, AE: 80% EtOH extracts of apple, MW: water extracts of mandarin orange peel, ME: 80% EtOH extracts of mandarin orange peel) for 1 min. OW showed higher than the other treatments for total phenolic contents(94.35 mg/g), PPO inhibition(74.00%). And the highest DPPH free radical scavenging activity(40.27%) measured in ME. ${\Delta}E$ value of apple slices dipped in MW was 2.37 whereas ${\Delta}E$ value of apple slices dipped in AW was 12.12. These results suggest that onion and mandarin orange peel extracts should be a potential source for controlling browning during storage of apple slices.

Phantom of the AAPM CT imaging evaluation Studies on the quantitative analysis method (CT 정도관리 영상의 정량적 분석방법에 관한 연구)

  • Kim, Young-su;Ko, Seong-Jin;Kang, Se-Sik;Ye, Soo-young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.271-274
    • /
    • 2016
  • CT quality assurance imaging evaluation and enforcement as quantitative assessment by phantom image evaluation, assessment items include There are also contrasting the water attenuation coefficient, uniformity, noise, resolution, spatial resolution, 10mm slice thickness evaluation, contrast resolution, space for the resolution, the slice thickness evaluation, it is possible to estimate the error due to the evaluation by the subjective judgment of the tester, using a subjective error image processing program to be computed to minimize the objective evaluation. Basic recording conditions of the CT image quality control assessment is the same as special medical equipment quality control checks, the images were evaluated quantitatively using IMAGE J. For a CT attenuation coefficient, the uniformity, noise evaluation, were evaluated as CT quality control image the standard deviation of the measured value of the digital processing of image smaller and less noise uniform images than the, contrast and resolution assessment is the size of the diameter of a circle having a large the 1 inch, 0.75 inch, 0.5 inch quality if the diameter of the circle, was evaluated in the small circle in the near circle ellipse. Spatial resolution is evaluated by using a self-extracting features of an image processing program, all of the groups of members comprising the acceptance criteria to automatically extract, was evaluated to be very useful for the quantitative assessment. When CT image quality control assessment on the basis of the results such as the above, if using an image processing program to minimize the subjective judgment of the error evaluator and is determined more efficient than would be made quantitative evaluation.

  • PDF

Antioxidative and Antibrowning Effects of Taraxacum platycarpum and Chrysanthemum indicum Extracts as Natural Antibrowning Agents (천연 갈변저해제로서의 민들레 및 감국 추출물의 항산화 및 갈변억제 효과)

  • Chang, Min-Sun;Park, Mi-Ji;Jeong, Moon-Cheol;Kim, Dong-Man;Kim, Gun-Hee
    • Food Science and Preservation
    • /
    • v.18 no.4
    • /
    • pp.584-589
    • /
    • 2011
  • This study was conducted to investigate the effects of Taraxacum platycarpum and Chrysanthemum indicum extracts on the browning of apple slices. The inhibition of the PPO activities, total phenolic contents, and DPPH free-radical-scavenging activities was measured from water and from the 80% EtOH extracts of Taraxacum platycarpum and Chrysanthemum indicum as natural antibrowning agents. Apples were cut into 15-mm-thick slices, and each slice was dipped for 1 min in different treatment solutions (1% Taraxacum platycarpum and Chrysanthemum indicum extracts, 1% citric acid) and was stored at room temperature. The inhibition of the PPO activity in the Chrysanthemumin indicum extract was better than that in the Taraxacum platycarpum extract. The highest DPPH free-radical-scavenging activity (76.10%) was found in the 80% EtOH extract of Chrysanthemum indicum. After 24 h, the ${\Delta}E$ value of the apple slices that were treated in the 80% EtOH extract of Chrysanthemum indicum was at the lowest level (2.22). The total phenolic content was 94.07 mg/g, and the total flavonoid content was 102.60 mg/g, in the 80% EtOH extract of Chrysanthemum indicum. The antibrowning effect of Chrysanthemum indicum was higher than that of Taraxacum platycarpum in the apple slices.

Motion Vector Coding Using Adaptive Motion Resolution (적응적인 움직임 벡터 해상도를 이용한 움직임 벡터 부호화 방법)

  • Jang, Myung-Hun;Seo, Chan-Won;Han, Jong-Ki
    • Journal of Broadcast Engineering
    • /
    • v.17 no.1
    • /
    • pp.165-178
    • /
    • 2012
  • In most conventional video codecs, such as MPEG-2 and MPEG-4, inter coding is performed with the fixed motion vector resolution. When KTA software was developed, resolution for MVs can be selected in each slice. Although KTA codec uses a variety of resolutions for ME, the selected resolution is applied over the entire pixels in the slice and the statistical property of the local area is not considered. In this paper, we propose an adaptive decision scheme for motion vector resolution which depends on region, where MV search area is divided to multiple regions according to the distance from PMV. In each region, the assigned resolution is used to estimate MV. Each region supports different resolution for ME from other regions. The efficiency of the proposed scheme is affected from threshold values to divide the search area and the entropy coding method to encode the estimated MV. Simulation results with HM3.0 which is the reference software of HEVC show that the proposed scheme provides bit rate gains of 0.9%, 0.6%, and 2.9% in Random Access, Low Delay with B picture, and Low Delay with P picture structures, respectively.

Measurement of CT Numbers for Effective Atomic Number And Physical Density of Compound (화합물의 물리적 밀도와 유효원자번호에 대한 CT수 측정)

  • Kim, Jong Eon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.125-130
    • /
    • 2021
  • In the AAPM CT performance phantom, there is little data on the CT number of the effective atomic number and physical density corresponding to each peg and water of the CT number calibration insert. Therefore, the necessity of documentation was raised.The purpose of this study is to calculate the effective atomic number for each peg and water of the CT number calibration insert in the AAPM CT performance phantom, and to measure the CT number for the calculated effective atomic number and physical density for comparative analysis.In order to obtain CT number data on the effective atomic number and physical density of each peg and water from the CT number calibration insert of the AAPM CT performance phantom, the effective atomic number for each peg and water was first calculated. Then, CT slices were obtained by scanning the CT number calibration with a CT scanner. CT numbers were measured for each peg and water in the central CT slice. As a result, the CT numbers for the effective atomic number showed a nonlinear pattern of repeating the increase and decrease as the effective atomic number increased. In addition, the CT numbers for physical density showed a nonlinear pattern of repeating the increase and decrease as the physical density increased.