• Title/Summary/Keyword: 디지털 X선

Search Result 109, Processing Time 0.02 seconds

Microcalcification Extraction by Wavelet Transform and Automatic Thresholding (웨이브렛 변환과 자동적인 임계치 설정에 의한 미세 석회화 검출)

  • Won, Chul-Ho;Seo, Yong-Su;Cho, Jin-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.8 no.4
    • /
    • pp.482-491
    • /
    • 2005
  • In this paper, we proposed the microcalcification detection algorithm which is based on wavelet transform and automatic thresholding method in the X-ray mammographic images. Digital X-ray imaging system is essential equipment in the field diagnosis and is widely used in the various fields such as chest, fracture of a bone, and dental correction. Especially, digital X-ray mammographic imaging is known as the most important method to diagnose the breast cancer, many researches to develop the imaging system are processing in country. In this paper, we proposed a microcalcifications detection algorithm necessary in the early phase of breast cancer diagnosis and showed that a algorithm could effectively detect microcalfication and could aid diagnosis-radiologist.

  • PDF

Development of Educational Training Assistance System on Digital Mobile X-ray Equipment (디지털 이동형 X선 장비의 교육용 보조 시스템 개발)

  • Kim, Ji-Soo;Yun, Ju-Hee;Lee, Ji-Won
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2021.11a
    • /
    • pp.1305-1307
    • /
    • 2021
  • 이동형 X선 장비를 이용하는 초보자들이 운전에 대한 부담감을 줄이고 손쉽게 훈련하면서도 장비의 손상을 방지하면서 교육할 수 있도록 안전한 X선 검사를 통한 국민보건향상을 위해 디지털 이동형 X선 장비의 교육용 보조 시스템을 개발하고자 하였다. 본 시스템은 교육 훈련을 위한 전용 코스 환경 개발, 장애물 인식을 위한 라인트레이서 탐색 및 초음파 센서 개발로 구성되어 있다. 학생들을 위한 이동형 X선 장비 교육을 위한 보조 시스템 개발로 이동형 X선 장비 전용 코스 환경은 교육을 위해 ㄷ형, T형, S형 등의 다양한 형태이다. 이 기능을 이용하여 각각의 코스에서 교육생들이 운전의 오류를 화면에 점수화하여 실무능력을 높일 수 있으리라 기대된다.

Trends on the Development of Carbon Nanotube-Based Digital X-ray Tube (탄소나노튜브 기반 디지털 엑스선 튜브 기술개발 동향)

  • Song, Y.H.;Kang, J.T.;Kim, J.W.;Choi, Y.C.;Park, S.;Jeong, J.W.
    • Electronics and Telecommunications Trends
    • /
    • v.31 no.2
    • /
    • pp.116-123
    • /
    • 2016
  • 병원의 X선 및 CT 영상, 반도체 소자 내의 결함분석, 공항의 보안검색 등 다양한 분야에 X선이 사용되고 있다. 지금까지는 이러한 X선을 발생시키기 위해 고온으로 가열하여 전자를 방출시키는 열전자원이 사용됐으나, 높은 소비전력과 디지털 구동의 어려움 등의 단점이 존재한다. 이러한 한계를 극복하기 위해 전계방출원 기술, 특히 탄소나노튜브를 이용한 나노전자원의 제조 및 디지털 엑스선 튜브 응용 기술에 관한 연구가 최근 활발히 진행 중이다. 이 글을 통해 디지털 시대에 부합하는 탄소나노튜브 기반 나노전자원 및 이를 이용한 디지털 엑스선 튜브의 개념 및 제조기술을 소개하고, ETRI 및 다른 기관들에서 개발 중인 최신 기술개발 동향을 소개하고자 한다.

  • PDF

Fuzzy Cluster Based Diagnosis System for Digital Mammogram (퍼지 클러스터 기반 디지털 유방 X선 영상 진단 시스템)

  • Rhee, Hyun-Sook;Yoon, Seok-Min
    • The KIPS Transactions:PartB
    • /
    • v.16B no.2
    • /
    • pp.165-172
    • /
    • 2009
  • According to the American Cancer Society, breast cancer is the second largest cause of cancer deaths and most frequently diagnosed cancer in women. The currently most popular method for early detection of breast cancer is the digital mammography. A mass or calcification lesion has been known as the most important clue for the diagnosis. In this paper, we propose a diagnosis approach based on fuzzy cluster knowledge base. We combine different two sources of feature data in duel OFUN-NET and produce the diagnosis result with possibility degree. We also present the experimental results on the dataset of mass and calcification lesions extracted from the public real world mammogram database DDSM. These results show higher classification accuracy than conventional methods and the feasibility as a decision supporting tool for diagnosis of digital mammogram.

The Defect Characterization of digital imaging Crystals by radiation exposed (디지털 영상 형광체의 방사선 노출에 의한 결함 특성)

  • Kim, Chang-Gyu
    • Proceedings of the KAIS Fall Conference
    • /
    • 2012.05a
    • /
    • pp.327-331
    • /
    • 2012
  • 양전자 소멸 분광법을 이용하여 X선으로 디지털 의료 영상을 회득하는 형광체를 X선 조사에 의한 형광체의 원자 크기 정도 결함의 특성을 조사하였다. 양전자와 전자의 쌍소멸에서 발생하는 511 KeV 감마선 스펙트럼의 수리적 해석 방법인 S-변수를 사용하여 결함의 정도를 측정하였다. 임상에서 X-선을 이용한 디지털 의료영상을 획득할 때 형광체로 사용하고 있는 시료를 사용기간별로 0, 2, 4, 6 구분하여 시료를 실험하였다. 각 시료들에서 측정된 S-변수는 0.4932부터 0.4956 정도의 변화를 보였다. 이에 상응하는 실험 방법으로 같은 시료에 X-선의 에너지와 조사시간 즉 6 MV 및 15 MV의 X-선을 사용하여 3, 6, 9, 그리고 12 Gy의 조사량을 변화시키면서 결함의 정도를 측정 비교하였다. 이 결과 형광체가 시용기간이 길어서 X선에 노출된 횟수가 많을수록 결함의 정도는 증가하는 경향을 보였고 X선의 에너지 강도가 강할수록 결함의 정도가 증가하는 경향을 보였다. 이것은 방사선에 노출된 빈도가 많을수록 영상을 획득하는데 보다 많은 선량이 요구되는 점과 영상의 화질이 저하는 현상을 결함특성 측정을 통하여 규명 하였다.

  • PDF

Is a Camera-Type Portable X-Ray Device Clinically Feasible in Chest Imaging?: Image Quality Comparison with Chest Radiographs Taken with Traditional Mobile Digital X-Ray Devices (카메라형 휴대형 X선 장치는 흉부 촬영에서 임상적 사용이 가능한가?: 기존의 이동형 디지털 X선 장치로 촬영한 흉부 X선 사진과 영상품질 비교)

  • Sang-Ji Kim;Hwan Seok Yong;Eun-Young Kang;Zepa Yang;Jung-Youn Kim;Young-Hoon Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.1
    • /
    • pp.138-146
    • /
    • 2024
  • Purpose To evaluate whether the image quality of chest radiographs obtained using a camera-type portable X-ray device is appropriate for clinical practice by comparing them with traditional mobile digital X-ray devices. Materials and Methods Eighty-six patients who visited our emergency department and underwent endotracheal intubation, central venous catheterization, or nasogastric tube insertion were included in the study. Two radiologists scored images captured with traditional mobile devices before insertion and those captured with camera-type devices after insertion. Identification of the inserted instruments was evaluated on a 5-point scale, and the overall image quality was evaluated on a total of 20 points scale. Results The identification score of the instruments was 4.67 ± 0.71. The overall image quality score was 19.70 ± 0.72 and 15.02 ± 3.31 (p < 0.001) for the mobile and camera-type devices, respectively. The scores of the camera-type device were significantly lower than those of the mobile device in terms of the detailed items of respiratory motion artifacts, trachea and bronchus, pulmonary vessels, posterior cardiac blood vessels, thoracic intervertebral disc space, subdiaphragmatic vessels, and diaphragm (p = 0.013 for the item of diaphragm, p < 0.001 for the other detailed items). Conclusion Although caution is required for general diagnostic purposes as image quality degrades, a camera-type device can be used to evaluate the inserted instruments in chest radiographs.

Computer Analysis of Interstital Lung Diseases in Chest Radiographs (흉부 X선 사진내의 간질성 폐질환의 컴퓨터 해석)

  • Kim, Eung-Kyeu
    • Proceedings of the KIEE Conference
    • /
    • 1999.11c
    • /
    • pp.775-777
    • /
    • 1999
  • 흉부 단순 X선 사진에 있어서 폐의 간질성 음영의 특징을 컴퓨터를 이용하여 해석하는 시스템을 구축하여 그 정확도를 검토하였다. 이 시스템에서는 X선 사진을 디지털화 해서 관심영역을 설정하여 4방향 라플라시안-가우시안 형상필터를 행하여 2치화 한후, 계속해서 선상음영 판정처리 및 선상음영 차분처리를 행해 간질성 음영의 특징을 나타내는 몇가지 물리적인 지표를 계산 하였다. 82명의 정상예와 이상예에 대하여 이들 물리적 지표의 ROC 해석을 행하여 간질성 폐질환 변화의 양호한 검출결과를 얻었다.

  • PDF

Computer analysis of pulmonary interstital patterns in chest radiographs (흉부 단순 x선 사진에 있어서 폐의 간질성 음영의 컴퓨터 해석)

  • 김응규;권영도;이주신
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.725-728
    • /
    • 1998
  • 흉부 단순 X선 사진에 있어서 폐의 간질성 음영의 특징을 컴퓨터를 이용하여 해석하는 시스템을 구축하여 그 정확도를 검토하였다. 이 시스템에서는 X선 사진을 디지털화 해서 관심영역을 설정하여, 4방향 라플라시안 -가우시안 형상필터를 행하여 2치화 한후, 계속해서 선상음영 판정처리 및 선상음영 차분처리를 햐해 간질성 음영의 특징을 나타내는 몇가지 물리적인 지표를 계산하였다. 82명의 정상예와 이상예에 대하여 이들 물리적 지표의 ROC 해석을 행하여 간질성 폐질환 변화의 양호한 검출결과를 얻었다.

  • PDF

Grid Angle Optimization and Grid Artifact Reduction in Digital Radiography Images Based on the Modulation Model (디지털 방사선 영상에서 그리드 각도의 최적화와 변조 모델에 기초한 그리드 왜곡의 제거)

  • Kim, Dong-Sik
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.48 no.3
    • /
    • pp.30-41
    • /
    • 2011
  • In order to obtain more clear x-ray images, an antiscatter grid, which can absorb the scattered rays, is employed. In the high-resolution direct digital radiography, however, the artifacts due to the grid are visible. In this paper, within the methods of obtaining x-ray digital images by employing the rotated grids for the facility of grid artifact reduction, the previous work, where the frequencies of the artifact components on the boundary, is further analyzed and extended, and a min-max optimization for a given grid density is proposed. For practical grid densities, appropriate grid angles are provided and a grid artifact reduction algorithm is proposed for the appropriate grid angles. The proposed algorithm is tested for real x-ray digital images with a comparison, and can remove the grid artifacts while maintaining the resolution of the original image.