• Title/Summary/Keyword: 디지털 평판

Search Result 100, Processing Time 0.026 seconds

Evaluation of Compaction Quality Control applied the Dynamic Cone Penetrometer Test based on IoT (다짐품질관리를 위한 IoT 기반 DCPT 적용 평가)

  • Jisun, Kim;Jinyoung, Kim;Namgyu, Kim;Sungha, Baek;Jinwoo, Cho
    • Journal of the Korean Geosynthetics Society
    • /
    • v.21 no.4
    • /
    • pp.1-12
    • /
    • 2022
  • Generally, the plate load test and the field density test are conducted for compaction quality control in earthwork, and then additional analysis. Recently developed that the DCPT (Dynamic Cone Penetration Test) equipment for smart compaction quality control its the system are able to get location and real-time information about worker history management. The IoT-based the DCPT system improved the time-cost in the field compared traditional test, and the functions recording and storage of the DPI (Dynamic Cone Penetration Index) were automated. This paper describes using these DCPT equipment on in-situ and compared to the standards of the DCPT, and the compaction trend had be confirmed with DPI as the field test data. As a result, the DPI of the final compaction decreased by 1.4 times compared to the initial compaction, confirming the increase in the compaction strength of the subgrade compaction layer 10 to 14 cm deep from the surface. A trend of increasing compaction strength was observed. This showed a tendency to increase the compaction strength of the target DPI proposed by MnDOT and the results of the existing plate load test, but there was a difference in the increase rate. Therefore, additional studies are needed on domestic compaction materials and laboratory conditions for target DPI and correlation studies with the plate load tests. If this is reflected, it is suggested that DCPT will be widely used as smart construction equipment in earthworks.

Comparison Research of SNR and SRb with Bright Calibration and Multi Frame Images in Digital Radiography of Welded Test Components (용접 시험편의 디지털 방사선 검사에서 밝기 교정과 중첩 영상에 따른 SNR 및 SRb 비교 연구)

  • Nam, Mun-Ho;Yang, Jin-Wook;Cho, Kap-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.731-739
    • /
    • 2021
  • This work compared the bright calibration of digital radiation with signal-to-noise ratio and basic spatial resolution according to multi frame to enable effective inspection of welding parts of structures at industrial sites. A total of 130 images were obtained by using a 75Se radiation source for flat weld test pieces and segmenting bright calibration and multi frame prior to shooting. The study confirms that the signal-to-noise ratio improves as the number of bright calibrations and the number of multi frame increases. The basic spatial resolution satisfied the baseline for both radiographic images. It was confirmed that the number of signal-to-noise ratio was similar by comparing images taken after installing lead shielding for scattering radiation. Although signal-to-noise ratio increases as multi frame increases, it is believed that good quality digital radiographs can be obtained if appropriate radiographic techniques are devised because exposure time of radiation affects workers' exposure and work efficiency.

Development of flat panel digital x-ray detectorusing a-Se (비정질 셀레늄을 이용한 평판 Digital X선 검출기 개발)

  • Park, J.K.;Choi, J.Y.;Kang, S.S.;Cha, B.Y.;Jang, G.W.;Choi, J.Y.;Nam, S.H.
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.6 no.1
    • /
    • pp.24-30
    • /
    • 2003
  • Flat-panel detector(FPD) is the driving force for realizing the next gene ration of x-ray system. In this study, we developed amorphous selenium(a-Se) based flat-panel digital X-ray detector(DXD) for radiography. The prototype detector consists of an amorphous selenium layer and a thin-film transistor(TFT) array. Comparing to other papers1)-4), optimization of amorphous selenium and progress of evaporation were similar. The pixel pitch of fabricated detector was $139{\mu}m$, fill factor was 86%, and the size was 14"${\times}$8.5". Hand and test bar pattern images were acquired. A high modulation transfer function(MTF) factor was obtained: 58% at 3.0 lp/mm.

  • PDF

A Study on Development of Interactive Contents for Digital Mirror (Digital Mirror를 위한 인터렉티브 콘텐츠 개발에 관한 연구)

  • Lee, Ki-Hoon;Jeong, Ji-Hong;Pan, Young-Hwan;Oh, Sung-Ryong;Park, Jin-Woo;Jo, Hyun-Cheol;Lee, Dong-Wook
    • 한국HCI학회:학술대회논문집
    • /
    • 2008.02b
    • /
    • pp.41-46
    • /
    • 2008
  • 디지털 기술의 발전은 인간 생활에 큰 변화를 가져다주었다. 이와 같은 디지털 기술의 발전으로 변화된 인간 생활 중 가장 큰 변화는 기술의 발전 이전에 사용되던 각종 제품 및 도구들이 디지털 기술의 힘으로 새롭게 재탄생하고 있다는 점이다. 재탄생된 제품 및 도구들은 사람과 제품간의 경계를 무너뜨리고 서로 융합되고 있다. 이러한 제품들 중에서 대표적으로 Digital Mirror를 들 수 있다. 기존 인간 생활에서 사용되던 일반적인 Mirror가 최근 들어 Digital Mirror라는 새로운 형태의 제품으로 연구되어 지고 있다. 이러한 Digital Mirror는 일상생활 속에서 기존 거울을 대체하고 있으며, 인터렉티브 미디어 아트에서도 많이 응용되고 있다. 현재 Digital Mirror는 광고, 인터렉티브 아트 등의 분야에서 다양한 형태의 콘텐츠가 개발되고 있다. 하지만 Digital Mirror를 새로운 제품 산업군으로 확대하여 신사업을 창출하기 위해서는 수많음 사용자들의 욕구를 충족시킬 수 있는 인터렉티브한 콘텐츠 제작을 해야 한다. 본 연구에서는 Digital Mirror의 인터렉티브한 콘텐츠 제작을 목적으로, 기존의 인터렉티브한 콘텐츠 사례를 중점적으로 연구하여 새로운 콘텐츠 아이디어를 도출하였다. 아이디어를 통해 어린이 사용자를 타켓으로 새로운 사용경험을 제공해 줄 수 있는 컨셉을 정하여 인기 애니메이션 캐릭터를 사실적으로 체험할 수 있게 해주는 콘텐츠 제작방향을 설정하여 연구를 진행하였다. 또한 놀이와 참여, 상호작용을 통한 새로운 디지털 놀이 도구라는 개념으로 AR기술을 이용해 캐릭터를 좀더 사실적으로 체험 할 수 있도록 제작하였다. 어린이 사용자가 캐릭터 마커를 착용하고 Digital Mirror앞에 서게 되면 캐릭터 마커에 해당되는 3차원 입체영상 애니메이션 캐릭터가 어린이 사용자의 모습과 합성되어 사실적인 캐릭터 콘텐츠를 체험 할 수 있게 해 주는 콘텐츠이다. 어린이들에게 인기 있는 캐릭터를 3D로 제작하여 캐릭터 소스로 활용하였고 이를 효율적으로 사용할 수 있도록 어플리케이션 저작툴을 개발 완료하여 제작하였다. 그리고 평판 디스플레이를 이용하여 실제 Prototype 제작하였다.

  • PDF

Image Quality Evaluation of Digital X-ray Image and Film Image using Contrast Method (Contrast Method를 이용한 디지털 X선 영상과 필름 영상의 영상 질(Quality) 평가)

  • Park, Ji-Koon;Jung, Bong-Jae;Choi, Jang-Yong;Kang, Sang-Sik
    • Journal of radiological science and technology
    • /
    • v.34 no.1
    • /
    • pp.9-15
    • /
    • 2011
  • In this paper, an image quality evaluation of amorphous selenium based x-ray system was performed using modulation transfer function (MTF) measurement. MTF as a main factor of imaging quality evaluation was investigated by contrast method from acquired test pattern image. The MTF value was measured to 36.1% at 3.0 lp/mm which is twice as high as that in the film image. Compared with other studies, the results demonstrate that amorphous selenium based x-ray detector is clinically meaningful.

Refractive media flatness measurement by phase shifting digital holography (위상천이 디지털 홀로그래피를 이용한 평판의 표면 평면도 측정)

  • Jeon, Sung-Bin;Kim, Do-Hyung;Cho, Jang-Hyun;Park, No-Cheol;Yang, Hyun-Seok;Park, Kyoung-Su;Park, Young-Pil
    • Transactions of the Society of Information Storage Systems
    • /
    • v.8 no.2
    • /
    • pp.44-49
    • /
    • 2012
  • We measured the surface flatness of both sides for refractive media using the transmitted digital holography method. To enhance the accuracy of the result, phase-shifting system was used. With two different phase modulation of reference beam, the phase profile of object can be easily obtained. Thus, we proposed the surface measurement method which can measure large area fast, compared with conventional methods. To guarantee the reliability of obtained result, we compared with Zygo measurement system. With the proposed method, the surface flatness of $3.45{\mu}m$ resolution could be obtained.

Development of X-ray Image Processing Technology for Nondestructive Measurement of the Coating Thickness in the Simulated TRISO-coated Fuel Particle (모의 TRISO 핵연료입자 코팅층 두께 비파괴 측정을 위한 X-선 영상처리기술 개발)

  • Kim Woong-Ki;Lee Young-Woo;Park Ji-Yeon;Ra Sung-Woong
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2006.05a
    • /
    • pp.669-672
    • /
    • 2006
  • 고온가스냉각 원자로에서는 고온 안정성 및 핵분열생성물 차단 성능이 우수한 TRISO(tri-tsotropic) 핵연료를 사용하고 있다. TRISO 핵연료 입자는 직경이 약 1 mm인 구 형태로 입자의 중심에는 직경 $0.5{\mu}m$의 핵연료 커널(kernel)이 포함되며 커널 외곽을 코팅 층이 에워싸고 있다. 이 코팅 층은 완충(buffer) PyC(pyrolytic carbon) 층, 내부 PyC 층, SiC 층, 그리고 외부 PyC 층으로 구성되어 있다. 각 코팅 층의 두께는 수십${\sim}$${\mu}m$ 범위이며, 본 연구에서는 각 코팅 층의 두께를 비파괴적으로 측정하기 위하여 마이크로포커스 X-선 발생장치와 고해상도 X-선 평판(flat panel) 검출기로 구성된 정밀한 X-선 래디오그래피 장치를 구성하고, $UO_2$ 핵물질 대신에 $ZrO_2$를 커널로 사용한 모의 TRISO 핵연료 입자에 대한 래디오그래피 영상을 획득한 후 디지털 영상처리기술을 이용하여 코팅 층 사이의 경계선이 구분 가능하도록 영상을 개선하고 디지털 영상처리 알고리즘을 개발하여 코팅 층의 두께를 측정하였다.

  • PDF

DR (Digital Radiography) 적용을 위한 Biology 초음파 특수용매를 이용한 $PbI_2$ 합성법

  • Kim, Seong-Heon;Yun, Min-Seok;O, Gyeong-Min;Kim, Yeong-Bin;Lee, Sang-Hun;Jo, Gyu-Seok;Park, Hye-Jin;Nam, Sang-Hui
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.146-146
    • /
    • 2009
  • 최근에 광도전체와 형광체를 기반으로 평판형 디지털 방사선 검출기의 상업적 발전가능성에 많은 관심을 가지고 있다. 본 연구는 기존의 직접변환방식에 널리 사용되었던 비정질 셀레늄 (amorphous selenium) 기반의 디지털 방사선 검출기보다 높은 전기적신호 및 동작특성을 가지는 물질층을 제작하기 위해 High Purity (99.99%)의 상용화된 $PbI_2$를 특수용매에 담가두었다가 약 1시간동안 Biology 초음파 처리한 후 농축기를 사용하여 건조된 $PbI_2$를 3Roll-milling을 사용하여 미세크기의 Powder를 얻어내었다. 합성된 $PbI_2$ Powder를 PIB(Particle-in-Binder)법을 이용하여 전도성을 가진 ITO(Indium-tin-oxide)코팅된 유리판에 제작된 필름의 상부에 Magnetron sputtering system 을 사용하여 전극을 $1cm{\times}1cm$의 크기로 증착하였다. I-V 테스트를 통하여 X선 조사시 $PbI_2$필름의 Sensitivity, Dark current, SNR(signal-to-noise ratio)을 측정하여 필름의 전기적 검출 특성을 정량적으로 평가하였고 SEM(scanning electron microscope)을 통하여 입자의 크기를 관찰하였다.

  • PDF

A Study on Quality Control for Medical Image by Using Deviation Index of Digital Radiology (디지털 방사선 영상의 편차지수를 이용한 의료영상 품질관리에 관한 연구)

  • Jeong, Hoi-Woun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.43 no.2
    • /
    • pp.115-121
    • /
    • 2020
  • In a digital radiation system using a Flat Panel Detector, we attempted to the quality control of digital radiography system using the Exposure Index and Deviation Index. Calibration was performed with the radiation quality suggested by the International Electrotechnical Commission, and through an experiment using a phantom, appropriate inspection radiation conditions applicable to medical institutions were selected. The study was conducted using the selected radiation conditions. Through those chest posterior anterior image, information such as examination conditions and exposure index was obtained. The deviation index was derived by analyzing the exposure index based on the target exposure index calculated by the phantom study. As for the analyzed exposure index, 97.1% was distributed within the range of ± 2.0 based on the deviation index. Quality control of medical images should be performed through management of inspection conditions through exposure index and deviation index and management of medical images.

Study on Establishment of Cadastral Surveying Fee System Suitable for Digital Cadastral Management Environment (디지털 지적관리 환경에 적합한 지적측량수수료 체계 확립 연구)

  • Hong, Sung-Eon
    • Journal of Digital Convergence
    • /
    • v.13 no.12
    • /
    • pp.23-30
    • /
    • 2015
  • The current cadastral business is being operated by conversion to a digital cadastral management system through computerized registers (land register and forest land register) and maps (cadastral map and forest cadastral map). Digital surveying methods, such as GPS surveying and electronic plane table surveying, are also used for cadastral surveying. At present, fees for cadastral surveying are calculated based on a standard pursuant to the Construction Standard Production Unit System and an announcement by the Ministry of Land, Infrastructure, and Transportation. In many cases, however, the cadastral surveying fee system announced at present fail to apply the digitalized environment depending on the item. This study sought to analyze the cadastral surveying fee system that requires improvement in the rapidly changing digital cadastral management environment, and to prepare a basis to establish a cadastral surveying fee system suitable to the digital environment by suggesting an improvement method for such system. As a result of the study, the following suggestions were made: a method of changing to terms suitable to the digital environment based on the current status analysis; preparation of a new estimation system regarding new estimation items; and re-survey of an estimation system of cadastral confirmation survey and preparation of an estimation system.