Abstract
This work compared the bright calibration of digital radiation with signal-to-noise ratio and basic spatial resolution according to multi frame to enable effective inspection of welding parts of structures at industrial sites. A total of 130 images were obtained by using a 75Se radiation source for flat weld test pieces and segmenting bright calibration and multi frame prior to shooting. The study confirms that the signal-to-noise ratio improves as the number of bright calibrations and the number of multi frame increases. The basic spatial resolution satisfied the baseline for both radiographic images. It was confirmed that the number of signal-to-noise ratio was similar by comparing images taken after installing lead shielding for scattering radiation. Although signal-to-noise ratio increases as multi frame increases, it is believed that good quality digital radiographs can be obtained if appropriate radiographic techniques are devised because exposure time of radiation affects workers' exposure and work efficiency.
Keywords
Digital Radiography; Basic Spatial Resolution; Signal to Noise Ratio;
Citations & Related Records
연도 인용수 순위
  • Reference
1 H. S. Ahn, "Digital Radiography", Journal of the Korean Society for Nondestructive Testing, Vol. 33, No. 1, pp. 80-95, 2013.
2 S. Lim, M. H. Nam, "Weld inspecrion platform of thermal power plant water well", Korean Electrical Society 46th Summer Congress, pp.1333-1334, 2015.
3 M. H. Nam, H. Jang, S. W. Park, C. S. Chung, "Real Time Digital Radiography System Development for Examination Aerospace Industrial Aluminium Castings", Summer Congress of Korea Electrical Society, pp. 1766-1767, 2010.
4 Y. S. Ahn, S. K. Park, B. C. Park, Y. H. Lee, "Non-Destructive Inspection for Welded Part by Using Digital Radiography Technique", Autumn Congress of The Korean Welding and Joining Society, Nov. 17, pp. 12-14, 2005.
5 Non-destructive testing-Industrial computed radiography with storage phosphor imaging plates - Part 1: Classification of systems, ISO 16371-1, 2011.
6 H. S. Park, M. S. Kim, H. M. Jung, J. W. Lee, "A Study on the Optimization of Image Quality and Dose in Chest PA Digital Radiography", Journal of the Korean Society of Radiology, Vol. 11, No. 1, pp 55-61, 2017.   DOI
7 S. K. Park, Y. S. Ahn, D. S. Gil. "Study on the Image Quality Comparison between in Digital RT and Film RT", Journal of the Korean Society for Nondestructive Testing, Vol. 31, No. 4, pp.391-397, 2011.
8 Non-destructive testing of welds-Radiographic testing - Part 2: X- and gamma -ray techniques with digital detectors, ISO 17636-2, 2013.
9 Non-destructive testing-Image quality of radiographs - Part 5: Determination of the image unsharpness and basic spatial resolution value using duplex wire-type image quality indicators, ISO 19232-5, 2018.
10 J. K. Park, B. J. Jung, H. H. Park, S. C. Noh, S. S. Kang, "The Study for Optimal Exposure Condition of Chest Examination of Digital Radiography System", Journal of the Korean Society of Radiology, Vol. 10, No. 2, pp 109-115, 2016.   DOI
11 J. H. Hwang, J. A. Choi, H. S. Kim, K. B. Lee, "Evaluation of Clinical Application Model of Optimized Parameter through Analysis of Stability of Radiation Output and Image Quality when Exposure Time Change of Digital Radiography", Journal of the Korean Society of Radiology, Vol. 14, No. 2, pp 139-148, 2020.