• Title/Summary/Keyword: 디지털 방사선 사진

Search Result 54, Processing Time 0.026 seconds

EDGE-DETECT INTERPOLATION FOR DIRECT DIGITAL PERIAPICAL IMAGES (경계강조 보간법을 이용한 디지털방사선사진상의 개선에 관한 연구)

  • Song Nam-Kyu;Koh Kwang-Joon
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.1
    • /
    • pp.73-85
    • /
    • 1998
  • The purpose of this study was to aid in the use of the digital images by edge-detect interpolation for direct digital periapical images using edge-detect interpolation. This study was performed by image processing of 20 digital periapical images; pixel replication, linear non-interpolation, linear interpolation. and edge-sensitive interpolation. The obtained results were as follows : 1. Pixel replication showed blocking artifact and serious image distortion. 2. Linear interpolation showed smoothing effect on the edge. 3. Edge-sensitive interpolation overcame the smoothing effect on the edge and showed better image.

  • PDF

A STUDY ON THE RADIOPACITY OF ESTHETIC DENTAL MATERIALS USING IN THE PEDIATRIC DENTISTRY (소아용 심미수복재의 방사선 불투과성에 관한 연구)

  • Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.1
    • /
    • pp.82-86
    • /
    • 2001
  • The aim of this study was to investigate the level of radiopacity of esthetic dental restorative materials and determine the optimum level of radiopacity in pediatric dentistry. Disks of 8 dental restorative material groups as the experimental group, 7mm in diameter and 2mm thick, were radiographed with intact human deciduous teeth and aluminum stepwedge standard. Radiopacity was evaluated with an image analysis program following the digitization of the radiographs using a flatbed scanner with transparency unit. All materials and tooth structure also the significant difference except FP, VB, VM. For the radiopacity of esthetic restorative dental materials to exceed that of enamel, it should be greater than 1.7mm of equivalent thickness of aluminum.

  • PDF

Evaluation of Cancer Detection Efficiency by Means of Hybrid and Inverse Filter in Chest Radiography (디지털 흉부 방사선 영상에서 Hybrid Filter와 Inverse Filter를 적용한 종양의 검출능 평가)

  • Kim, Youn-Young;Kim, Tae-Young;Kim, Hyun-Ji;Park, Min-Seock;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.36 no.4
    • /
    • pp.319-326
    • /
    • 2013
  • The purpose of this study is to evaluate usefulness of Hybrid image and Inverse image about detection of tumor shadow in chest radiography using ROC analysis. Original images of 60 cases are selected from Standards digital image date base issued by the Japanese Society of Radiological Technology. Through computer language of C, Inverse images of 60 cases and Hybrid image of 30 cases are made. The continues reading experiment was conducted. In the case of inverse image were observed by 5 radiographer and 2 radiologist. In the case of In case of Hybrid image were observed by 3 student radiographer and 2 experienced radiographer. ROC curve are constructed using ROCKIT Program made by Metz. In Inverse image, a Az of average ROC curve was increases from 0.742 of original image to 0.775 of inverse image. In normal cases, the effect of the detrimental is same to that of the beneficial, however In abnormal cases, the beneficial effect is greater than detrimental effect. However in Hybrid image, a Az of average ROC curve was decreases from 0.5253 of original image to 0.4868 of Hybrid image. In Normal cases, the effect of the detrimental is greater than that of the Beneficial, however In abnormal cases, the Beneficial effect is greater than detrimental effect. The inverse image can be more positively considered for the detecting of tumor than the hybrid image.

Setup Verification in Stereotactic Radiotherapy Using Digitally Reconstructed Radiograph (DRR) (디지털화재구성사진(Digitally Reconstructed Radiograph)을 이용한 정위방사선수술 및 치료의 치료위치 확인)

  • Cho, Byung-Chul;Oh, Do-Hoon;Bae, Hoon-Sik
    • Radiation Oncology Journal
    • /
    • v.17 no.1
    • /
    • pp.84-88
    • /
    • 1999
  • Purpose :To develop a method for verifying a treatment setup in stereotactic radiotherapy by ma- tching portal images to DRRs. Materials and Methods : Four pairs of orthogonal portal images of one patient immobilized by a thermoplastic mask frame for fractionated stereotactic radiotherapy were compared with DRRs. Portal images are obtained in AP (anteriorfposterior) and lateral directions with a target localizer box containing fiducial markers attached to a stereotactic frame. DRRs superimposed over a planned iso-center and fiducial markers are printed out on transparent films. And then, they were overlaid over onhogonal penal images by matching anatomical structures. From three different kind of objects (isgcenter, fiducial markers, anatomical structure) on DRRs and portal images, the displacement error between anatomical structure and isocenters (overall setup error), the displacement error between anatomical structure and fiducial markers (irnrnobiliBation error), and the displacement error between fiducial markers and isocenters (localization error) were measured. Results : Localization error were 1.5$\pm$0.3 mm (AP), 0.9$\pm$0.3 mm (lateral), and immobilization errors were 1.9$\pm$0.5 mm (AP), 1.9$\pm$0.4 mm (lateral). In addition, overall setup errors were 1.0$\pm$0.9 mm (AP), 1.3$\pm$0.4 mm (lateral). From these orthogonal displacement errors, maximum 3D displacement errors($\sqrt{(\DeltaAP)^{2}+(\DeltaLat)^{2}$)) were found to be 1.7$\pm$0.4 mm for localization, 2.0$\pm$0.6 mm for immobilization, and 2.3$\pm$0.7 mm for overall treatment setup. Conclusion : By comparing orthogonal portal images with DRRs, we find out that it is possible to verify treatment setup directly in stereotactic radiotherapy.

  • PDF

Analysis of Image Quality According to BMI of Digital Chest Radiography: Focusing on Bureau of Radiological Health Evaluation (디지털 흉부 방사선 영상의 체질량지수에 따른 영상품질 분석: 미국 방사선 안전국 규정 평가표 중심으로)

  • Jin, Seong-jin;Im, In-Chul;Cho, Ji-Hwan
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.1-6
    • /
    • 2017
  • Visual evaluation of chest radiograph images is the most practical and effective method. This study compared the Body Mass Index, waist circumference, and mAs with chest radiographs of 351 women. The Bureau of Radiological Health method was used to evaluate the image quality of chest X-ray images by anatomical and physical methods. The average age of the subjects was $30.17{\pm}4.73$ and the average waist circumference was $66.91{\pm}4.67cm$. The mean Body Mass Index value was $20.21{\pm}2.23$, the mean value of mAs was $3.04{\pm}0.78$, and the mean value of Bureau of Radiological Health was $79.83{\pm}8.45$. When the Body Mass Index value increased, waist circumference and mAs mean value increased. The mean value of Body Mass Index was statistically significant(p<0.05) in Group 4 compared to Groups 1 and 2, with increasing Body Mass Index. Exposure control of the automatic exposure control system is considered to be well performed according to body thickness or Body Mass Index at the time of chest radiography. As the Body Mass Index increases, the thickness of the body increases and the breast thickness of the woman also increases. Therefore, it is considered that the exposure amount is changed by the automatic exposure control device to affect the image quality.

THE DETECTABILITY OF BONE LOSS IN THE BIFURCATION OF MANDIBULAR MOLARS ON PERIAPICAL RADIOGRAPHS AND DIGITAL IMAGES: AN EXPERIMENTAL STUDY (방사선 사진과 디지털 영상에서 실험적 치근 이개부 병소의 감지도에 관한 연구)

  • Lee Geon-Il;You Hyung-Keun;Shin Hyung-Shik
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.25 no.1
    • /
    • pp.99-107
    • /
    • 1995
  • The aim of this study was to evaluate clinician's detectability in the diagnosis of bone loss in the bifurcation of mandibular molars on periapical radiographs and Digital images. Periapical radiographs were obtained of the first molars in 2 dry mandibles after preparation of bony defects corresponding to degree I, degree II and degree III buccal furcation involvements. The radiographs were randomly presented to 39 clinicians(1 oral radiologist, 4 periodontist, 34 general dentists) who were asked to determine the presence or absence of bone loss. Periapical films were digitized with a TV camera. Digital images were assessed by 15 clinicians(1 oral radiologist, 4 periodontist, 10 general dentists). I. the overall diagnostic accuracy of Digital images for detection of bone loss in the bifurcation of mandibular molars was higher than that of the periapical radiographs. 2. the largest increase in diagnostic accuracy was found between lesion grade II and III on both radiographs and Digital images(P<0.05). 3. there was no significant difference between the standard state and the controlled contrast state on Digital images. 4. the overall diagnostic accuracy of I radiologist and 4 periodontists was better than that of the general dentists for detecting bifurcation involvements.

  • PDF

Development of Medical Examination and Treatment System for Dental Clinic (치과병원 전산화를 위한 통합 진료 시스템 구축)

  • 채옥삼;강승훈
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.40 no.2
    • /
    • pp.26-37
    • /
    • 2003
  • Unlike a medical doctor, a dentist performs all the tasks necessary for diagnosis and treatment of a disease all by himself. To increase the diagnostic accuracy, dentists need an efficient working environment providing much more integrated information of clinical data and radiographic image. In this paper, we propose an integrated environment for the dental hospital. It provides paperless and filmless hospital environment by integrating seamlessly three major operations for the dental hospital including patient record generation and management, clinical image acquisition and analysis, and treatment planning and simulation. This system also allows clinicians to provide more predictable dental care for the patients by supporting instant access to all the clinical data and quantitative data analysis.

Patients Setup Verification Tool for RT (PSVTS) : DRR, Simulation, Portal and Digital images (방사선치료 시 환자자세 검증을 위한 분석용 도구 개발)

  • Lee Suk;Seong Jinsil;Kwon Soo I1;Chu Sung Sil;Lee Chang Geol;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.21 no.1
    • /
    • pp.100-106
    • /
    • 2003
  • Purpose : To develop a patients' setup verification tool (PSVT) to verify the alignment of the machine and the target isocenters, and the reproduclbility of patients' setup for three dimensional conformal radiotherapy (3DCRT) and intensity modulated radiotherapy (IMRT). The utilization of this system is evaluated through phantom and patient case studies. Materials and methods : We developed and clinically tested a new method for patients' setup verification, using digitally reconstructed radiography (DRR), simulation, porial and digital images. The PSVT system was networked to a Pentium PC for the transmission of the acquired images to the PC for analysis. To verify the alignment of the machine and target isocenters, orthogonal pairs of simulation images were used as verification images. Errors in the isocenter alignment were measured by comparing the verification images with DRR of CT Images. Orthogonal films were taken of all the patients once a week. These verification films were compared with the DRR were used for the treatment setup. By performing this procedure every treatment, using humanoid phantom and patient cases, the errors of localization can be analyzed, with adjustments made from the translation. The reproducibility of the patients' setup was verified using portal and digital images. Results : The PSVT system was developed to verify the alignment of the machine and the target isocenters, and the reproducibility of the patients' setup for 3DCRT and IMRT. The results show that the localization errors are 0.8$\pm$0.2 mm (AP) and 1.0$\pm$0.3 mm (Lateral) in the cases relating to the brain and 1.1$\pm$0.5 mm (AP) and 1.0$\pm$0.6 mm (Lateral) in the cases relating to the pelvis. The reproducibility of the patients' setup was verified by visualization, using real-time image acquisition, leading to the practical utilization of our software Conclusions : A PSVT system was developed for the verification of the alignment between machine and the target isocenters, and the reproduclbility of the patients' setup in 3DCRT and IMRT. With adjustment of the completed GUI-based algorithm, and a good quality DRR image, our software may be used for clinical applications.

Findings on Chest Low-Dose CT Images of Group Exposed to Inorganic Dusts (분진에 노출되었던 집단의 흉부 저선량 CT영상 소견)

  • Lee, Won-Jeong;Seon, Jong-Ryul;Ahn, Bong-Seon;Park, Young-Sun
    • Journal of radiological science and technology
    • /
    • v.34 no.4
    • /
    • pp.305-314
    • /
    • 2011
  • The purpose of this study was to compare the findings on the chest low-dose CT (LDCT) images between the negative and positive groups for pneumoconiosis in the group exposed to inorganic dust. From May 30, 2007 to August 31, 2008, total 328 subjects were examined by a LDCT. LDCT images were read by a chest radiologist who has much experience for reading of pneumoconiosis. All subjects were classified into two groups based on digital images after consensus reading of two radiologists according to the ILO 2000 guidelines; negative group (87, 26.5%) without pneumoconiosis and positive group (241, 73.5%). Statistical analysis was performed using a SPSS 14.0. There were significant differences in age (60.9 vs. 65.0, p<0.001), and in dust expose duration (17.0 vs. 19.2, p=0.024) between two groups, but no significant difference in smoking (p=0.784). Of the 328 subjects, 13 diagnosis were extracted from 245 subjects (74.7%). Coronary artery calcification (CAC) was significantly higher in positive group than that in negative group (36.9% vs. 25.3%, p=0.049). Honeycombing showed higher frequency in positive group than in negative group (6.2% vs. 1.2%, p=0.079). Pneumoconiosis findings caused by inorganic dusts exposure showed the significant relation with CAC on LDCT images. Future studies need to prove that pneumoconiosis finding is independent risk factor for CAC using a coronary artery angiography.

Surface Topographic Measurement Method for Assessing Lower Extremity Alignment: Examination on a novel clinical and research Tool (하지 정렬 평가를 위한 체표면 토포그래피를 이용한 측정법: 새로운 임상 및 연구 도구에 대한 검토)

  • Yim, Ji-Young;Yim, Hyun-Seung;Park, Dae-Sung;Lee, Na-Kyung;Lee, Na-Kyung
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.1
    • /
    • pp.37-45
    • /
    • 2016
  • The purpose of this study was to assess the intra-rater, inter-rater and test-retest reliability and validity of frontal plane lower extremity alignment estimated from a rasterstereographic method using ABW-Mapper. Eighteen subjects participated in this study. The S angle (stereographic angle-frontal plane lower extremity alignment estimated from a rasterstereographic method) in standing was measured throughout the two sessions with one week interval by two different readers. In the first session, a reader measured S angle twice per subject with a short break in-between. The Q-angle (quadriceps angle) was measured using a standard goniometer from a photography taken through digital camera with the participant standing in the same position as in the S angle measurement. The HKA(hip-knee-ankle) angle was measured from a computer based digital radiograph with the computerized measurement software. Reliability was tested using intraclass correlation coefficients(ICC). Validity was tested using a Pearson's correlation coefficient. Excellent intra-rater(ICC=0.956~0.974), inter-rater(ICC=0.962), test-retest reliability (ICC=0.945) were demonstrated. There were strong negative correlations between S angle and Q-angle (r=-0.739), and between S angle and HKA angle (r=-0.702). Therefore, the S angle measured using a rasterstereographic mapper may be used to as a preliminary or supplementary tool to evaluate and study LE alignment in the frontal plane in relation to HKA angle or Q-angle.