• 제목/요약/키워드: 디지털 방사선 사진

검색결과 54건 처리시간 0.023초

경계강조 보간법을 이용한 디지털방사선사진상의 개선에 관한 연구 (EDGE-DETECT INTERPOLATION FOR DIRECT DIGITAL PERIAPICAL IMAGES)

  • 송남규;고광준
    • 치과방사선
    • /
    • 제28권1호
    • /
    • pp.73-85
    • /
    • 1998
  • The purpose of this study was to aid in the use of the digital images by edge-detect interpolation for direct digital periapical images using edge-detect interpolation. This study was performed by image processing of 20 digital periapical images; pixel replication, linear non-interpolation, linear interpolation. and edge-sensitive interpolation. The obtained results were as follows : 1. Pixel replication showed blocking artifact and serious image distortion. 2. Linear interpolation showed smoothing effect on the edge. 3. Edge-sensitive interpolation overcame the smoothing effect on the edge and showed better image.

  • PDF

소아용 심미수복재의 방사선 불투과성에 관한 연구 (A STUDY ON THE RADIOPACITY OF ESTHETIC DENTAL MATERIALS USING IN THE PEDIATRIC DENTISTRY)

  • 정태성;김신
    • 대한소아치과학회지
    • /
    • 제28권1호
    • /
    • pp.82-86
    • /
    • 2001
  • 현재 사용중인 소아용 심미수복재 8종(글라스 아이오노머 및 레진계)에 대한 방사선 불투과성을 치아의 법랑질 및 상아질과 비교하였다. 다양한 방사선 노출조건에 따른 알루미늄 stepwedge에 대한 표준곡선의 변이를 알아보고, 그 중 안전하고 적절한 노출 조건을 선택하여 촬영한 10종류의 소아수복용 심미 수복재에 대한 방사선 사진을 디지털화 한 다음 방사선 불투과성의 정도를 그 화상을 분석하는 방법으로 알루미늄 두께로 환산하여 비교함으로써 상대적인 방사선 불투과성을 알아보았다. 실험에 사용된 모든 심미수복재는 상아질보다 방사선 불투과상을 나타내었으며, FP, VB, VM에서는 유치 법랑질과 방사선 불투과성이 차이가 인정되지 않았으나 이외의 재료에서는 법랑질보다 높은 방사선 불투과상을 보였다. 금속입자가 함유된 KF 에서 방사선불투과성이 가장 높은 것으로 나타났으며 VM에서 방사선불투과성이 가장 낮게 나타났다. 소아용 심미 수복재가 유치 법랑질보다 높은 방사선 불투과성을 가지기 위해서는 동일한 알루미늄 두께인 1.7mm보다 더 두꺼워야 한다.

  • PDF

디지털 흉부 방사선 영상에서 Hybrid Filter와 Inverse Filter를 적용한 종양의 검출능 평가 (Evaluation of Cancer Detection Efficiency by Means of Hybrid and Inverse Filter in Chest Radiography)

  • 김윤영;김태영;김현지;박민석;김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제36권4호
    • /
    • pp.319-326
    • /
    • 2013
  • 본 연구에서는, 흉부단순사진에 있어서 종양그림자의 검출에 대한 흑백 Inverse image과 Hybrid image의 유용성을 ROC해석으로 검토하였다. 증례의 선택은 일본방사선기술학회가 발행한 표준 Digital 영상 Date Base로부터 30장을 선택 하여 original image로 하였다. c언어를 통해 Inverse image는 60장, Hybrid image는 30장 제작하였다. 실험방법으로 연속 판독실험을 하였고, ROC실험 display program은 Matlap을 통하여 작성하였다. 관찰자의 수는 Inverse image의 경우 방사선사 5명과 방사선의 2명, 합계 7명으로 실험하였다. Hybrid 영상의 경우, 방사선 전공자 3명과 숙련된 방사선사 2명, 합계 5명으로 실험하였다. ROC곡선은 Metz가 작성한 ROCKIT Program을 이용하여 구하였다. Inverse image의 경우 관찰자 7명 전원, 방사선과의 2명, 방사선사 5명의 평균 ROC곡선의 Az는 각각 original image의 0.742, 0.793, 0.721에서, Inverse image의 0.775, 0.821, 0.753까지로, 통계적 유의차로 증가하였다. Hybrid image의 경우 관찰자 5명 전원, 숙련된 방사선사 2명, 방사선학 전공자 3명의 평균 ROC곡선의 Az는 각각 original image의 0.525, 0.491, 0.5478에서, Hybrid 영상의 0.4868, 0.539, 0.450로 변화 하였다. 결론적으로, 흉부단순사진에서 종양의 검출에 관하여, Inverse image은 유의하지만, Hybrid 영상의 경우 유의한 차이가 나타나지 않았다.

디지털화재구성사진(Digitally Reconstructed Radiograph)을 이용한 정위방사선수술 및 치료의 치료위치 확인 (Setup Verification in Stereotactic Radiotherapy Using Digitally Reconstructed Radiograph (DRR))

  • 조병철;오도훈;배훈식
    • Radiation Oncology Journal
    • /
    • 제17권1호
    • /
    • pp.84-88
    • /
    • 1999
  • 목적 : 정위방사선치료에서 디지털화재구성사진(Digitally Reconstructed Radiograph, DRR)과 조사문사진을 비교함으로써 환자의 치료위치를 직접 확인할 수 있는 방법을 개발킨 1명의 하고자 한다. 대상 및 방법 : 분할정위방사선치료를 위해 thermoplastic mask 틀에 고정시환자를 대상으로 4회 촬영한 전후 방향(AP) 및 측면 방향(lateral)에 대한 조사문사진과 DRR을 비교하였다. 치료위치 setup 후에, 혈관조영용 표적조준기와 같은 fiducial marker가 부착된 표적조준기를 정위수술용 틀에 부착한 후 치료용 원형 콜리메이터의 설치 전과 후에 겹조사 방식으로 촬영하여 전후방향 및 측면 방향의 조사문사진을 얻었다. 병변 및 중요 장기와 fiducial marker의 위치를 합성시킨 DRR 영상을 만들어 조사문사진과 동일한 확대율 및 크기로 투명 필름에 인쇄하여 비교하였다. 이로부터 DRR과 조사문사진상에 표시된 해부학적 구조와 치료중심점의 거리 오차(전체 치료 오차), 해부학적 구조와 fiducial marker간의 오차(환자고정 오차), 그리고 치료중심점과 fiducial marker간의 오차(치료조준 오차)를 각각 구하였다. 결과 : 치료조준 오차는 각각 1.5$\pm$0.3mm(AP), 0.9$\pm$0.3mm(lateral) 이었고, 환자고정 오차는 1.9$\pm$0.5mm(AP), 1.9$\pm$0.4mm(lateral), 그리고 전체 치료 오차는 AP 상에서 1.6$\pm$0.9mm, lateral 상에서 1.3$\pm$0.4mm 이었다. 또한 AP와 lateral 오차로 인해 발생될 수 있는 3차원 공간상의 최대 가능 오차($\sqrt{(\DeltaAP)^{2}+ (\Delta$Lat)^{2}$)는 치료조준 오차가 1.7$\pm$0.4mm, 환자고정 오차가 2.6$\pm$0.6mm, 그리고 전체 치료 오차는 $2.3\pm0.7mm$로 나타났다. 결론 : DRR 영상을 재구성하는 프로그램을 개발하였으며, DRR 영상을 조사문사진과 비교함으로써 정위방사선치료에서 직접적인 치료위치 확인이 가능하였다.

  • PDF

디지털 흉부 방사선 영상의 체질량지수에 따른 영상품질 분석: 미국 방사선 안전국 규정 평가표 중심으로 (Analysis of Image Quality According to BMI of Digital Chest Radiography: Focusing on Bureau of Radiological Health Evaluation)

  • 진성진;임인철;조지환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권1호
    • /
    • pp.1-6
    • /
    • 2017
  • 흉부방사선 영상의 평가는 시각에 의한 사진평가가 가장 실용적이고 효과적인 방법으로 알려져 있다. 미국 방사선 안전국 규정 평가표(Bureau of Radiological Health, BRH)는 흉부방사선 영상의 해부학적 평가와 물리적 평가를 합하여 평가하는 효율적인 영상 평가방법이다. 본 연구는 여성 351명의 흉부방사선 영상을 체질량지수(Body Mass Index, BMI)와 허리둘레, 관전류량(mAs)과의 관계를 비교하고, 미국 방사선 안전국 규정 평가표를 사용하여 흉부 방사선 영상품질평가를 시행하였다. 대상자의 평균 연령은 $30.17{\pm}4.73$세이고, 허리둘레는 평균 $66.91{\pm}4.67cm$이었다. 체질량지수 값의 평균은 $20.21{\pm}2.23$으로 나타났으며, 전체 대상자의 관전류량 평균값은 $3.04{\pm}0.78$이고, 미국 방사선 안전국 규정 평균값은 $79.83{\pm}8.45$이었다. 허리둘레가 커질수록 관전류량 값이 증가함으로 나타났으며, 체질량지수가 커질수록 mAs값도 증가하였다. 연구대상자의 허리둘레, 관전류량, 미국 방사선 안전국 규정 값은 체질량지수 값이 커지면 허리둘레와 관전류량 평균값이 증가하였고, 미국 방사선 안전국 규정 값은 체질량지수가 높은 그룹이 낮은 그룹에 비하여 상대적으로 낮게 나타났으며, 통계적으로 유의하였다. 흉부검사 시 피검자의 신체두께나 체질량지수에 따라 자동노출제어 장치의 노출제어가 적절히 잘 이루어진 것으로 생각되며, 체질량지수가 증가할수록 신체두께가 커지고 또한 여성의 유방 두께도 증가하여 자동노출제어 장치에 의한 노출량이 변화되어 영상품질에 영향을 미치는 것으로 생각되어진다.

방사선 사진과 디지털 영상에서 실험적 치근 이개부 병소의 감지도에 관한 연구 (THE DETECTABILITY OF BONE LOSS IN THE BIFURCATION OF MANDIBULAR MOLARS ON PERIAPICAL RADIOGRAPHS AND DIGITAL IMAGES: AN EXPERIMENTAL STUDY)

  • 이건일;유형근;신형식
    • 치과방사선
    • /
    • 제25권1호
    • /
    • pp.99-107
    • /
    • 1995
  • The aim of this study was to evaluate clinician's detectability in the diagnosis of bone loss in the bifurcation of mandibular molars on periapical radiographs and Digital images. Periapical radiographs were obtained of the first molars in 2 dry mandibles after preparation of bony defects corresponding to degree I, degree II and degree III buccal furcation involvements. The radiographs were randomly presented to 39 clinicians(1 oral radiologist, 4 periodontist, 34 general dentists) who were asked to determine the presence or absence of bone loss. Periapical films were digitized with a TV camera. Digital images were assessed by 15 clinicians(1 oral radiologist, 4 periodontist, 10 general dentists). I. the overall diagnostic accuracy of Digital images for detection of bone loss in the bifurcation of mandibular molars was higher than that of the periapical radiographs. 2. the largest increase in diagnostic accuracy was found between lesion grade II and III on both radiographs and Digital images(P<0.05). 3. there was no significant difference between the standard state and the controlled contrast state on Digital images. 4. the overall diagnostic accuracy of I radiologist and 4 periodontists was better than that of the general dentists for detecting bifurcation involvements.

  • PDF

치과병원 전산화를 위한 통합 진료 시스템 구축 (Development of Medical Examination and Treatment System for Dental Clinic)

  • 채옥삼;강승훈
    • 전자공학회논문지SC
    • /
    • 제40권2호
    • /
    • pp.26-37
    • /
    • 2003
  • 치과의사는 일반 의사들과 다르게 진단과 치료를 위한 거의 모든 과정을 혼자서 처리하는 것이 일반적이다. 이러한 환경에서 치과의사의 진단효율을 향상시키기 위해서는 진단자료와 방사선사진이 동시에 제시되는 효율적인 진료환경이 필요하다. 본 논문에서는 치과병원에서의 진단과 치료를 위한 통합환경을 제안한다 제안된 시스템은 치과병원의 주요업무인 환자기록생성, 진단을 위한 영상취득과 분석, 치료계획수립, 시술시뮬레이션 등을 하나의 시스템으로 유기적으로 결합함으로서 필름과 종이가 없는 병원환경을 실현하였다. 또한 모든 임상자료의 신속한 검색과 정량적인 분석을 지원함으로서 환자에게 보다 정확하고 예측이 가능한 치료를 제공할 수 있도록 하였다.

방사선치료 시 환자자세 검증을 위한 분석용 도구 개발 (Patients Setup Verification Tool for RT (PSVTS) : DRR, Simulation, Portal and Digital images)

  • 이석;성진실;권수일;추성실;이창걸;서창옥
    • Radiation Oncology Journal
    • /
    • 제21권1호
    • /
    • pp.100-106
    • /
    • 2003
  • 목적 : 네트워크를 이용해 영상수집을 하여 방사선치료를 수행하는데 요구되는 기계중심점과 종양중심점의 일치여부 및 환자자세의 재현성을 확인하는 기능 등을 수행할 수 있는 환자자세검증도구를 개발하고자 한다. 대상 및 방법 : 전산화단층촬영 영상으로부터 재구성한 디지털화재구성사진(digitally reconstructed radiography, DRR) 영상과 투과 영상인 모의치료영상, 상용전자포탈 영상장치에서 수집한 포탈영상 밑 CCD 카메라로부터 획득한 디지털영상 등을 네트워크를 통해 수집하였고, 이를 조작할 수 있는 분석용 프로그램을 프로그램 제작툴인 IDL(IDL 5.4, Research systems, USA)을 이용해 작성하였다. 이를 환자자세 검증도구(patients setup verification tool for RT, PSVTS)라 명명하였다. 기계중심점과 종양중심점의 일치여부 확인은 전산화단층촬영영상으로부터 재구성한 DRR 영상과 모의치료영상을 이용하여 위치변위를 분석함으로써 치료조준오차를 구하였다. 환자자세의 재현성 확인은 첫 치료 시에 얻은 포탈 영상과 매 치료 시마다 얻는 포탈영상을 비교, 분석하는 방법과 디지털영상을 이용하는 방법을 사용하였다. 결과 : 방사선치료 시 요구되는 기계 중심점과 종양중심점의 일치여부 및 환자자세의 재현성을 확인할 수 있는 사용자편의방식의 소프트웨어와 환자자세검증도구를 개발하였다. 종양중심점과 기계중심점의 일치여부 확인 결과 치료조준오차는 두경부에서 전후, 좌우 각각 0.8$\pm$0.2 mm, 1.0$\pm$0.3 mm이었고, 골반부에서 1.1$\pm$0.5 mm, 1.0$\pm$0.6mm이었다. 환자자세 재현성은 영상을 실시간으로 획득하여 환자 자세 위치 변화를 시각적으로 평가할 수 있어실용성 있음을 알 수 있었다. 결론 : 환자자세의 재현성 및 종양중심점과 기계중심점의 일치여부를 파악할 수 있는 환자자세검증도구를 개발하였고, DRR 영상의 질 증진, 사용자편의방식의 소프트웨어를 보완한다면 임상응용에 가능할 것으로 사료된다.

분진에 노출되었던 집단의 흉부 저선량 CT영상 소견 (Findings on Chest Low-Dose CT Images of Group Exposed to Inorganic Dusts)

  • 이원정;선종률;안봉선;박영선
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제34권4호
    • /
    • pp.305-314
    • /
    • 2011
  • 분진에 노출된 집단의 흉부 디지털영상에서 진폐 소견에 따라 흉부 저선량 CT영상에서 발견된 소견을 비교 분석하였다. 2007년 4월부터 2008년 8월 사이 일개 진폐정밀건강진단기관에 내원한 진폐정밀건강진단 대상자 남자 328명에 대해 저선량 CT촬영을 실시하였고, 진폐 판독경험이 많은 1명의 영상의학과 전문의가 판독하였다. 흉부 디지털영상의 진폐 소견은 국제노동기구 흉부 영상 분류법(ILO, 2000)따라 아날로그 표준 사진을 참조하여 2명의 영상의학과 전문의가 합의 판독한 결과로부터 얻었고, 소음영의 병형에 따라 진폐 소견이 없는군(87명, 26.5%)과 있는군(241명, 73.5%)으로 분류하였다. 진폐 소견이 있는군에서 나이(60.9 vs. 65.0, p<0.001)와 분진노출기간(17.0 vs. 19.2, p=0.024)이 통계학적으로 유의하게 높았지만, 흡연력은 차이가 없었다. 전체 대상자 328명 중 245명(74.7%)이 저선량 CT영상에서 13 종류의 소견이 발견되었다. 진폐 소견이 없는군 보다 있는군에서 관상동맥 석회화 소견이 통계학적으로 의미 있게 높은 빈도를 보였고(25.3% vs. 36.9%, p=0.049), 벌집모양 소견도 높은 빈도를 보였다(1.2% vs. 6.2%, p=0.079). 하지만, 저선량 CT영상에서 진폐 소음영을 시사하는 작은 결절은 진폐 소견이 없는 군에서 더 높은 빈도를 보여 흉부 디지털영상이 민감도가 낮았다. 이상의 결과에서 분진 노출에 의한 진폐 소견이 저선량 CT영상의 관상동맥 석회화 소견과 유의한 관련성을 보였지만, 독립적인 위험요인임을 규명하기 위해서는 관상동맥 혈관 조영술을 이용한 전향적인 추가 연구가 필요할 것으로 사료된다.

하지 정렬 평가를 위한 체표면 토포그래피를 이용한 측정법: 새로운 임상 및 연구 도구에 대한 검토 (Surface Topographic Measurement Method for Assessing Lower Extremity Alignment: Examination on a novel clinical and research Tool)

  • 임지영;임현승;박대성;이재헌;이나경
    • 재활복지공학회논문지
    • /
    • 제10권1호
    • /
    • pp.37-45
    • /
    • 2016
  • 이 연구의 목적은 래스터입체사진술이 적용된 ABW-mapper를 사용하여 얻은 관상면 상에서의 하지 정렬 측정에 대하여 측정자 내, 측정자 간, 측정-재측정 간 각각의 신뢰도와 타당도를 조사하고 평가하는 것이다. 열여덟 명의 대상자가 이 연구에 참여하였다. 일주일간격으로 두 번의 세션에 걸쳐서 두 사람의 측정자가 각각 ABW-mapper를 사용하여 기립자세에서의 S각(입체사진 각-래스터입체사진 촬영을 통해 측정한 관상면상의 하지 정렬 측정 각)을 측정하였고, 첫 번째 세션에서는 짧은 시간 간격으로 한 측정자가 같은 대상자에 대하여 두 번씩 측정하였다. Q각은 디지털카메라로 기립자세를 촬영한 사진에서 고니어미터로 측정하였다. HKA각은 컴퓨터 기반 디지털 방사선 영상사진 위에서 측정 소프트웨어를 사용하여 측정하였다. 급내상관계수(ICC)를 통해 신뢰도를 분석하였고, 피어슨 상관계수를 사용하여 타당도를 검사하였다. 그 결과, S각 측정은 매우 높은 측정자 내 (ICC=0.956~0.974), 측정자 간 (ICC=0.962) 검사-재검사 간 (ICC=0.945) 신뢰도를 나타냈으며, S각과 Q각, S각과 HKA각 사이에는 강한 음의 상관관계(각각 r=-0.739, -0.702)를 나타냈다. 따라서, ABW-mapper에 의한 래스터입체사진법을 통한 S각 측정은 관상면에서의 하지정렬의 측정에 대하여 Q각이나 HKA각 측정에 관련하여 예비적 또는 보완적 도구로 사용될 수 있을 것이라 생각된다.