• Title/Summary/Keyword: 디지털 방사선 사진

Search Result 54, Processing Time 0.033 seconds

Comparison of Direct Digital Radiography and Conventional Film Screen Radiography for Detection of Peritoneal Fluid in Dogs (개에서 복수의 평가에 있어서 필름-증감지 방사선 사진과 디지털 방사선 사진의 비교)

  • Choi, Ho-Jung;O, I-Se;Lee, Ki-Ja;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.29 no.1
    • /
    • pp.18-22
    • /
    • 2012
  • This study was performed to evaluate the sensitivity of conventional film-screen radiography (CFSR) and direct digital radiography (DDR) for detection of various amounts of free peritoneal fluid. Ten adult male healthy beagles were used in this study. Radiographic examinations were performed in the right lateral and ventrodorsal positions. Fluid was injected in increments of 2.0 ml/kg of body weight up to 20.0 ml/kg of body weight. The images of CFSR and DDR were evaluated by two veterinary radiologists for evidence of abdominal fluid without knowledge of injected fluid volume. Data were evaluated by using the receiver operation curve (ROC) analysis and the area under the curve (AUC). There was no significant difference in detection of peritoneal fluid between DDR and CFSR in the ROC analysis. The accuracy of CFSR (0.805) was relatively higher than that of DDR (0.733), based on the ROC analysis and AUC. AUC of CFSR was higher in most injection doses. These results suggest that CFSR is more accurate than DDR for the detecting peritoneal fluid. Therefore, for situation in which digital radiographs are equivocal or small amount of fluid is suspected, other imaging modalities, such as ultrasonography would be helpful for determining the presence of fluids.

Digital imaging of film-based cephalograms using a digital camera (디지털 카메라를 이용한 필름 두부방사선사진의 디지털 이미지 전환)

  • Wang, Sung-Jin;Kim, Kyung-Ho;Choy, Kwang-Chul
    • The korean journal of orthodontics
    • /
    • v.34 no.5 s.106
    • /
    • pp.448-457
    • /
    • 2004
  • As computer Programs for cephalometric analysis were developed in diagnosis & treatment planning, digital imaging of film-based cephalograms came to be needed. When a digital camera is used, a problem encountered the image distortion produced according to the focal length, which causes errors in indentifying landmarks. In addition, changes in the image size and compression ratio will inevitably produce a low quality image, causing errors in identifying landmarks. Hence. we have found the focal length producing the least image distortion when digital imaging the film-based cephalograms and the minimal digital camera setting which helps to identify the correct landmarks using the COOLPIX4500 digital camera (Nikon, Japan). The results were as follows The image distortion was minimized at a focal length of 16.4mm (79.4mm when converted into a 35mm film camera) when digital imaging the film-based cephalograms. When wide imaging, with a focal length of under IS.4mm, barrel distortion was found and when tole imaging. with a focal length of over 15.4mm pincushion distortion was found. The minimal digital camera setting was $2272{\times}1704$ pixel at normal (1/8) compression from which we can identify the correct landmarks at the same level as tracing the film-based cephalograms manually. As a result. when digital imaging the film-based cephalograms, using a COOLPIX4500 digital camera (Nikon, Japan), the focal length should be 16.4mm the pixel image size over $2272{\times}1704$, and the compression ratio over normal (1/8).

A comparison of periapical radiographs and their digital images for the detection of dental caries (인접면 치아우식증의 진단의 치근단 X선사진과 디지털영상의 비교)

  • Kang Byung-Cheol
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.24 no.1
    • /
    • pp.31-35
    • /
    • 1994
  • 전남대학교 치과진료처에 내원한 환자의 구내방사선사진중 1단계 (Cl: 30개 병소)또는 2단계(C2: 213.8병소)의 인접면 치아우식을 가진 방사선사진 168장을 연구대상으로 하였다. 이들 방사선사진은 코닥사의 Ektaspeed(E group) 필름을 사용하여 평행촬영법으로 촬영하였다. 168장의 방사선사진에 대하여 1단계 및 2단계 치아우식증을 4명의 구강악안면방사선학을 전공한 치과의사들이 같이 판독하여 그 결과를 기록하였다. 또한 168장의 방사선사진을 필름-비디오 변환장치를 이용하여 디지털 영상으로 전환하였다. 이때 486 DX PC에 PCVision과 frame grabber를 이용하였다. 각각의 구내방사선사 진영상은 17"크기의 1280×768픽셀의 해상도를 갖는 모니터상에서 256단계 흑화도를 갖는 700×480픽셀로 제시되었다. 모니터상에서의 치아우식 판독 결과를 구내방사선사진 판독 결과와 비교하였다. 그 결과 sensitivity는 0.98이었다. 1단계 치아우식은 0.87, 2단계 치아우식 은 1.00의 sensitivity를 나타내었다.

  • PDF

The comparison of landmark identification errors and reproducibility between conventional lateral cephalometric radiography and digital lateral cephalometric radiography (일반두부방사선계측사진과 디지털방사선계측사진의 계측점 식별의 오차 및 재현성에 관한 비교 연구)

  • Lee, Yang-Ku;Yang, Won-Sik;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.32 no.2 s.91
    • /
    • pp.79-89
    • /
    • 2002
  • The purpose of this study is to evaluate the reproducibility and errors in landmark identification of conventional lateral cephalometric radiography and digital lateral cephalometric radiography. Fifteen conventional lateral cephalometric radiographs and fifteen digital lateral cephalometric radiographs were selected in adults with no considerations on sex and craniofacial forms. Each landmark was identified and expressed as the coordinate (x, y). The landmarks were classified into 3 groups. The landmarks of the first identification was T1, identification after one week was T2, and identification after one month was T3. The mean and standard deviation of identification errors between replicates were calculated according to the x and y coordinates. The errors between first identification and second identification were expressed as T2-T1(x), T2-T1(y) and those between first identification and third identification were expressed as T3-T1(x), T2-T1(y). Each was divided into conventional lateral cephalometric radiography and digital lateral cephalometric radiography. The independent t- test was used for statistical analysis of identification errors for the evaluation of reproducibility. The results of this study were as follows ; 1. Generally, the mean and standard deviation of landmark identification errors in digital lateral cephalometric radiography was smaller than those of conventional lateral cephalometric radiography. 2. Only a few landmarks showed statistically significant difference in identification error between conventional lateral cephalometric radiography and digital lateral cephalometric radiography. 3. The enhancement of image quality didn't guarantee decrease in landmark identification error and didn't affect tendency of landmark identification error.

Convergence and integration study related to development of digital contents for radiography training using dental radiograph and augmented reality (치과방사선사진과 증강현실을 활용한 방사선촬영법 숙련용 디지털 콘텐츠 개발에 대한 융복합 연구)

  • Gu, Ja-Young;Lee, Jae-Gi
    • Journal of Digital Convergence
    • /
    • v.16 no.12
    • /
    • pp.441-447
    • /
    • 2018
  • This study aims to develop digital techniques that enable repeated practice of dental radiography using augmented reality technology. A three-dimensional object was fabricated by superimposing a photograph of an adult model and a computed tomography image of a manikin phantom. The system was structured using 106 radiographs such that one of these saved radiographs is opened when the user attempts to take a radiograph on a mobile device. This system enabled users to repeatedly practice at the pre-clinical stage without exposure to radiation. We attempt to contribute to enhancing dental hygienists' competency in dental radiography using these techniques. However, a system that enables the user to actually take a radiograph based on face recognition would be more useful in terms of practice, so additional studies are needed on the topic.

Evaluation of bone quality in alveolar crest obscured by dental implants ; A pilot study by densitometric digital analysis in mandibular bone specimen (치과 임플란트 주변 협설측 치조골의 변화분석 - 하악골 시편에서의 디지털 농도분석법을 이용한 실험적 고찰 -)

  • Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.6
    • /
    • pp.900-913
    • /
    • 1998
  • Despite of technical difficulties, the combination of occlusal projection and densitometric digital analysis may ultimately provide a means of detection of subtle bone loss at the facial and lingual side of dental implant (Oblique occlusal view is more useful for $ITI^{(R)}$ dental implant due to its contour of shoulder as like tulip flower). In this study, conventional periapical projections of x-ray beam had shown more high sensitivity to detect the bony defects than oblique occlusal projections in alveolar crest obscured by dental implants or not, even if the difference was not statistically significant. Unlike conventional periapical projections. occusal projections combined with densitometric digital analysis technique may provide a means for detection of subtle bone change at the all around of implants without obscuring effect by implant itself. Although the results from this in vitro study were performed under limited circumstances, these results might afford more possibility and versatile modality of diagnosis options to clinician in the implant practice.

  • PDF

Reproducibility of Lateral Cephalometric Landmarks According to Radiographic Image Enhancement (방사선상 enhancement 정도에 따른 측모두부방사선규격사진 계측점 설정의 재현도)

  • Ryu, Hwang-Sog;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.32 no.1 s.90
    • /
    • pp.59-69
    • /
    • 2002
  • The purpose of this study was to evaluate the reproducibility of lateral cephalometric landmarks according to radiographic image enhancement, and to contribute to the identification of cephalometric landmarks. Lateral cephalograms of ten individuals were taken and stored into computer. The images were then enhanced up to four grades by Quick Ceph Image Pro$^{TM}$ on condition that the gray-scale equalization number was 50 and the detail enhancement number was 50. After thirty two landmarks were identified on monitor images by five observers, the deviations from the mean, the distances estimated between identified points and the mean point of five identified points, were evaluated for each landmark at each enhancement grade. Through the statistical analysis, following results were obtained. 1. In case of unenhanced radiographic images, the inter-observer reproducibility of the landmarks showed a large variation. 2. The comparison of deviation from the mean according to the degree of radiographic image enhancement for each landmark showed that the inter-observer reproducibility was significantly different at 5 landmarks. 3. The landmark of pterygomaxillary fissure showed higher reproducibility at enhancement grade 1 and 2 images than at unenhanced images. So did the landmark of posterior nasal spine at enhancement grade 1 images, and the landmark of menton at enhancement grade 2, 3 and 4 images respectively. The above results suggest that the reproducibility of some landmarks can be increased by radiographic image enhancement during the identification of the lateral cephalometric landmarks on the monitor.

Quantitative assessment of alveolar bone density change after initial periodontal therapy using digital imaging (디지털영상을 이용한 초기 치주처치후 치조골 밀도변화의 정량적 평가)

  • Ahn, Kyung-Hyun;Kim, Jae-Duk;Kim, Byung-Ock
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.4
    • /
    • pp.777-785
    • /
    • 2001
  • 치주질환이 진행되는 동안이나 치주처치후 치유되는 과정에서 치조골의 변화가 야기되는데 방사선 사진은 치조골 변화를 감지하는 유일한 비외과적인 방법이다. 미묘한 치조골 변화의 진단은 치료시나 유지관리기 환자의 평가시 중요한 바, 최근에는 규격화시킨 디지털 영상을 이용하여 정량적인 골변화 측정이 가능하게 되었다. 본 연구의 목적은 중등도의 치주질환을 지닌 환자에서 국소마취하에 초기 치주처치를 시행한후 참조체와 함께 구내 방사선 사진을 촬영하고 디지털화 한 다음 참조체 당량치를 이용하여 치조골의 밀도변화를 평가하기 위한 것이다. 이 연구를 위하여 치주질환에 이환된 환자 5명(남자 3명, 여자 2명 : 평균 47.4세)에서 탐침깊이가 5㎜ 이상이고 골내낭이 있는 제 $1{\cdot}2$ 소구치, 제 $1{\cdot}2$ 대구치 40개(상악 24개, 하악 16개)를 대상으로 구강위생교육과 치석제거술, 치근면활택술을 시행하였다. 임상지수는 술전과 술후 8주째에 측정하였고, 방사선 사진은 술전, 술후 2주, 4주, 6주, 8주째에 촬영하였고, 구리 스텝웨지를 사용하여 규격화 하였다. 촬영된 영상은 NIH image program(U.S.A)에 의해 분석되어졌고 이들 자료를 통해 다음과 같은 결과를 얻었다. 1. 치조골의 밀도는 초기치료후 2주째 까지는 감소된 양상을 보이다가 4주 이후로는 점차적으로 증가하는 양상을 보였다. 2. 치조골의 밀도는 초기치료전과 비교시 초기치료수 6주째와 8주째에서 유의한 차이를 보였다.(p<0.01) 3. 상하악 간의 치조골 밀도는 유의한 차이를 보이지 않았다(p>0.05). 이상과 같은 결과를 통하여 볼때 초기 치주처치만으로도 치조골의 밀도가 증가됨을 확인할 수 있었다.

  • PDF