• Title/Summary/Keyword: 디스크 거칠기

Search Result 13, Processing Time 0.04 seconds

Flow in a cylinder driven by rotating disk with concentrically-grooved surface (동심원 형상 홈이 파여진 원판이 회전하고 있을 때의 실린더 내부유동에 관한 연구)

  • Yoon, Myung-Sup;Park, Jun-Sang;Hyun, Jae-Min
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.622-627
    • /
    • 2003
  • A numerical study is made of a flow in a cylinder with a rotating grooved endwall disk. The aim is to describe differences in the flow fields when there is concentrically-grooved obstacle characterized by amplitude(a) and wave number(N). The Reynolds number(Re) is varied from $10^{3}$ to $10^{4}$ and the aspect ratio(Ar) fixed to 1.0 for the most part of the simulation. For the various cases of amplitude(a) and wave number(N), numerical results are acquired. As the endwall groove roughness increases until certain limit, the interior azimuthal velocity component(v) increases drastically. But over the limit, the swirl motion chararcterized by velocity v decreases and finally it approaches much alike Ar=1.0-a case. The reason of activating swirl motion is based on increasing of torque transported by endwall disk. Torque coefficients($C_{T}$) are aquired for the various (a,N,Re) combinations and the limiting phenomena of swirl motion activation is explained.

  • PDF

The Effect of Surface Characterization Parameters on Sliding Friction (표면거칠기의 변화에 따른 미끄럼 마찰 특성)

  • Kim, Tae-Wan;Lee, Sang-Don;Cho, Yong-Joo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.3 no.2
    • /
    • pp.18-24
    • /
    • 2004
  • The effect of surface characterization parameters, such as surface roughness, skewness and kurtosis, on sliding friction and wear was studied experimentally. The friction coefficient was examined under the various parameters and sliding speed, normal load and type of lubricant with ball-on-disk type tribo-meter. The surface of the lower skewness in negative or the higher kurtosis between the same arithmetic mean value tends to indicate low friction.

  • PDF

Micro-Tribological Investigation for Temperature Rise in Multi-layered Thin Films (다층 박막의 온도상승에 대한 마이크로 트라이볼로지적 조사)

  • Kim, Joon-Hyun;Shin, Kyung-Ho
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.760-765
    • /
    • 2000
  • The study deals with the development of a computational procedure for evaluating the temperature rise in dry and lubricated multi-layered contacts of head/disk interface. A transient computational model with a transformed rectangular computational domain is utilized. A model and a computational method for micro-contact with sub-lubricated zone, including friction heat generation, have been presented. The model was applied, taking full account of the changes in contact area and contact load due to frictional heating. The computational distribution of temperature is obtained with the analytical findings for various composition and contact conditions. Especially, a rapid rise ($220^{\circ}C$ or above) in read head temperature lese to a saturation in the influence of a thermal spike on signal performance. This general class of problems can be treated provided that heat generation distribution and layer properties are known.

  • PDF

An in vitro study of mesenchymal stem cell proliferation on titanium discs coated with rhTGF-β2/PLGA by electrospray (Electrospray법으로 rhTGF-β2/PLGA 복합체를 코팅한 티타늄에서의 간엽줄기세포 증식에 관한 연구)

  • Kim, Joohyung;Kim, Seong-Kyun;Heo, Seong-Joo;Koak, Jai-Young;Lee, Woo-Sung;Lee, Joo-Hee;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.2
    • /
    • pp.120-125
    • /
    • 2016
  • Purpose: The purpose of this study is to identify the effect of mesenchymal stem cell proliferation on recombinant human transforming growth factor-beta (rhTGF-${\beta}2$) / poly (D,L-lactide-co-glycolide) (PLGA) treated titanium discs by electrospray. Materials and methods: Anodized titanium surface coated with PLGA was used for a control group to compare anodized titanium surface coated with 125 ng/ml and 500 ng/ml rhTGF-${\beta}2$ as test groups. Atomic force microscope (AFM) test was utilized to determine the difference in coating surface roughness, and field-emission scanning electron microscopy (FE-SEM) was taken to visualize even distribution of coating particles on titanium discs. The mesenchymal stem cell proliferation was tested by using MTT (3-(4,5-dimethylthiazol-2-yl)-2,5 diphenyl-tetrazolium bromide) assay on 1st, 4th, 7th days. Results: According to AFM results, there was no statistically significant difference in titanium discs treated with PLGA and with rhTGF-${\beta}2$/PLGA (P>.05). MTT assay test results showed that there was statistically significant difference in mesenchymal stem cell proliferation on test groups compared to control groups at 7th day, and cell viability on discs coated with rhTGF-${\beta}2$ was significantly higher than control groups (P<.05). Conclusion: Titanium surface coated with rhTGF-${\beta}2$/PLGA shows statistically significant higher cell proliferation and the titanium surface coated with the higher concentration of rhTGF-${\beta}2$ presents faster cell growth activity.

Effect of fluoride-containing gel on the roughness of a titanium surface and the promotion of bacterial growth (불소함유 겔이 티타늄 표면의 세균성 바이오필름 성장에 미치는 영향)

  • Kim, Sun-Jin;Lee, Jae-Kwan;Chang, Beom-Seok;Lee, Si-Young;Um, Heung-Sik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.1
    • /
    • pp.16-23
    • /
    • 2016
  • Purpose: The aim of this study was to evaluate whether fluorides at various pH cause changes in the surface roughness of titanium implants that alter the adherence of bacterial biofilms. Materials and Methods: The titanium disks were assigned randomly to the following seven groups according to the fluoride agents and application time (1 minute or 30 minute) used: control (no treatment); group 1 (1.23% acidulated phosphate fluoride [APF] at pH 3.5 for 1 minute); group 2 (1.23% APF at pH 3.5 for 30 minute); group 3 (1.23% APF at pH 4.0 for 1 minute); group 4 (1.23% APF at pH 4.0 for 30 minute); group 5 (2% NaF gel at pH 7.0 for 1 minute); group 6 (2% NaF gel at pH 7.0 for 30 minute). The surface roughness of the titanium disks and the amount of adherent bacteria were measured. Results: Group 2 showed a significantly greater surface roughness than the control group (P < 0.0001). No significant differences in the amount of surface bacteria were observed between the treated samples and the controls. In addition, there were no significant differences in bacterial adherence relative to the incubation period between the treated samples and the controls. Conclusion: The surface roughness of the titanium disks was significantly greater after treatment with APF at pH 3.5 for 30 min compared with that of the controls. In addition, we found that the amount of Porphyromonas gingivalis, Fusobacterium nucleatum, and Aggregatibactor actinomycetemcomitans was similar among all groups

Evaluation of titanium surface properties by $Nd:YVO_4$ laser irradiation: pilot study ($Nd:YVO_4$ 레이저 조사에 따른 티타늄의 표면특성 평가: 예비 연구)

  • Kim, Ae-Ra;Park, Ji-Yoon;Kim, Yeon;Jun, Sei-Won;Seo, Yoon-Jeong;Park, Sang-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.3
    • /
    • pp.167-174
    • /
    • 2013
  • Purpose: This study was conducted to evaluate the roughness and surface alternations of three differently blasted titanium discs treated by $Nd:YVO_4$ Laser irradiation in different conditions. Materials and methods: Thirty commercially pure titanium discs were prepared and divided into three groups. Each group was consisted of 10 samples and blasted by $ZrO_2$ (zirconium dioxide), $Al_2O_3$ (aluminum oxide), and RBM (resorbable blasted media). All the samples were degreased by ultrasonic cleaner afterward. Nine different conditions were established by changing scanning speed (100, 300, 500 mm/s) and repetition rate (5, 15, 35 kHz) of $Nd:YVO_4$ Laser (Laser Pro D-20, Laserval $Korea^{(R)}$, Seoul, South Korea). After laser irradiation, a scanning electron microscope, X-ray diffraction analysis, energy dispersive X-ray spectroscopic analysis, and surface roughness analysis were used to assess the roughness and surface alternations of the samples. Results: According to a scanning electron microscope (SEM), titanium discs treated with laser irradiation showed characteristic patterns in contrast to the control which showed irregular patterns. According to the X-ray diffraction analysis, only $Al_2O_3$ group showed its own peak. The oxidation tendency and surface roughness of titanium were similar to the control in the energy dispersive X-ray spectroscopic analysis. The surface roughness was inversely proportional to the scanning speed, whereas proportional to the repetition rate of $Nd:YVO_4$. Conclusion: The surface microstructures and roughness of the test discs were modified by the radiation of $Nd:YVO_4$ laser. Therefore, laser irradiation could be considered one of the methods to modify implant surfaces for the enhancement of osseointegration.

A study of mesenchymal stem cell proliferation and surface characteristics of the titanium discs coated with MS275/PLGA by an electrospray (Electrospray법을 이용한 MS275/PLGA submicron 코팅 티타늄에서의 표면변화와 간엽줄기세포증식에 관한 연구)

  • Yoo, Soo-Yeon;Kim, Seong-Kyun;Heo, Seong-Joo;Koak, Jai-Young;Lee, Joo-Hee;Park, Yoon-Kyung;Kim, Ena
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.4
    • /
    • pp.285-291
    • /
    • 2012
  • Purpose: This study was conducted to identify the surface characteristics of titanium discs coated with MS275/PLGA by electrospray and which is effective to mesenchymal stem cell proliferation. Materials and methods: We used anodized surface coated with PLGA as a control group and anodized surface coated with MS275 $0.5{\mu}M$, $1{\mu}M$, $1.5{\mu}M$ as test groups. To examine that the coating particles are nanometer sized, FE-SEM was used and AFM was utilized to determine the difference of coating surface roughness. We checked the mesenchymal stem cell proliferation by using MTT assay on $1^{st}$, $4^{th}$, $7^{th}$ days. Results: There was no significant difference between control groups and test groups in AFM results (P>.05). In MTT assay results, mesenchymal stem cell proliferation was increased with time, at $7^{th}$ day, cell viability on discs coated with $1.5{\mu}M$ MS275 was significantly higher than control group (P<.05). As SEM showed, the number of cells on all discs was increased and the morphology of cell attachment was also wider and closer with time. Conclusion: Titanium surface coated with MS275/PLGA showed significantly higher cell proliferation and the more density of MS275 was dispersed on titanium discs, the faster cells grew.

Surface roughness and color stability of various composite resins (수종의 복합 레진의 표면 거칠기와 색 안정성)

  • Lee, Sung-Yi;Kim, Hyeon-Cheol;Hur, Bock;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.6
    • /
    • pp.542-549
    • /
    • 2007
  • The purpose of this study was to evaluate the difference in the surface roughness after polishing and to evaluate the difference in color stability after immersion in a dye solution among four types of composite resin materials. Four light-polymerized composite resins(Shade A2) with different sized filler content(a nanofilled, a hybrid, a microfilled, a flowble) were used. Average surface roughness (Ra) was measured with a surface roughness tester (Surftest Formtracer) before and after polishing with aluminum oxide abrasive discs(Super-Snap). Color of specimens before and after staining with 2% methylene blue solution were measured using spectrophotometer(CM-3700d) with SCI geometries. The results of Ra and ${\Delta}E$ were analyzed by one-way analysis of variance(ANOVA), a Scheffe multiple comparison test and Student t-test(p=0.05). After polishing, Ra values were decreased regardless of type of composite resins. In surface roughness after polishing and color stability after staining, nanofilled composite resin was not different with other composite resins except flowable resins.

Friction Force Microscopy Analysis of Diamond-like Carbon Films (다이아몬드상 카본 박막의 Friction Force Microscopy 분석)

  • Choi, Won-Seok;Lee, Jong-Hwan;Song, Beom-Young;Heo, Jin-Hee;You, Jin-Soo;Hong, Byung-You
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.181-181
    • /
    • 2008
  • DLC (Diamond-like Carbon) 박막은 높은 내마모성과 낮은 마찰 계수, 화학적 안정성 및 적외선 영역에서의 높은 투과율과 낮은 광 반사도, 높은 전기저항과 낮은 유전율, 전계방출특성 등 여러 가지 장점을 가진 물질이다[1]. 최근에는 DLC 박막의 여러 장점들과 산과 염기 유기용매에 대한 화학적 안정성으로 인하여 인조관절에서 인공심장의 판막에 이르기까지 의공학 관련 부품소재로 응용되고 있으며 내구성과 안정성에 있어서 탁월한 성능을 보여주고 있다. 또한 DLC 박막의 높은 경도와 낮은 마찰 계수, 부드러운 박막 표면 (수nm의 RMS 거칠기)의 장점을 살려 마그네틱 미디어와 하드디스크의 슬라이딩 표면에 사용되어지고, MEMS (Micro-Electro Mechanical System) 소자와 MMAs (Moving Mechanical Assemblies)의 고체윤활코팅으로 활용하여 미세기계의 내구성과 성능 향상을 도모할 수 있다. 이와 같이 DLC 박막은 다양한 분야에 응용되고 있으며, 박막이 지닌 여러 가지 장점들로 인하여 더 많은 분야에 응용될 가능성을 지닌 물질이다. 그러나 수 ${\mu}m$이상의 두께에서 박막이 높은 잔류응력 (residual stress)을 가지고, 열에 취약하여 이의 개선에 관한 연구들이 진행되어 지고 있다 [2]. 따라서 사용되는 목적에 따라 용도에 맞는 양질의 DLC 박막을 합성하기 위해선 합성 장치의 개발과 다양한 실험을 통한 최적의 합성조건 도출 등의 노력이 요구된다. 또한 DLC 박막 합성시의 여러 가지 증착 방법에 따른 박막 물성에 대한 재현성 확보 및 박막 증착에 관한 명확한 메커니즘 규명이 아직까지는 불분명하여 이에 관한 연구가 시급하다. 따라서 본 연구에서는 MEMS 소자와 MMAs의 고체윤활코팅으로 사용가능한 DLC 박막을 RF PECVD (Plasma Enhanced Vapor Deposition) 방식으로 합성하고 후열처리 온도에 따른 DLC 박막의 마찰계수 변화를 박막에 훼손을 주지 않는 FFM (Friction Force Microscopy) 방식을 사용하여 분석하였다.

  • PDF

Surface Roughness and Cariogenic Microbial Adhesion after Polishing of Smart Chromatic Technology-based Composite Resin (Smart Chromatic Technology 기반 복합 레진의 폴리싱 이후 표면 거칠기 및 우식원성 미생물 부착 )

  • Haesong Kim;Juhyun Lee;Haeni Kim;Howon Park
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.50 no.1
    • /
    • pp.65-74
    • /
    • 2023
  • This study compared the surface roughness and microbial adhesion characteristics of Omnichroma, a novel composite resin developed using "smart chromatic technology", with those of two other conventional composite resins with different filler compositions. A total of 144 specimens were fabricated using 3 types of composite resins: Omnichroma (nano-spherical), Filtek Z350XT (nanofill), and Tetric N-Ceram (nanohybrid) and, divided into 3 groups of 48. Finishing was performed using tungsten carbide burs. Specimens were then divided into 3 subgroups using different polishing methods: Control, SofLex, and PoGo. Surface roughness was analyzed quantitatively and qualitatively using an atomic force microscope and a scanning electron microscope. Microbial adhesion was assessed by culturing Streptococcus mutans on the specimens for 24 hours and then measuring colony-forming units attached to the upper surface. The surface roughness (Ra) of Omnichroma was 0.123 ㎛ after finishing, and it exhibited a smooth surface compared to the other resins. However, after polishing, there were no significant differences in the surface roughness between the three composite groups, regardless of the polishing methods. The surfaces of the Control subgroups were significantly rougher than those of the SofLex subgroups in all 3 composite groups. However, except for Tetric N-Ceram, there were no significant differences between the Control and PoGo subgroups in the other composite groups. Microbial adhesion assessment showed no significant differences between any of the 3 composite resin subgroups; however, Omnichroma exhibited higher microbial adhesion than the other two composites. No significant correlation was observed between surface roughness and microbial adhesion.