• Title/Summary/Keyword: 동적 입체시

Search Result 21, Processing Time 0.03 seconds

The Comparasion of the Dynamic Stereoacuity with Two-Rods Test and Three-Rods Test (이간계와 삼간계를 이용한 동적 입체시의 비교)

  • Shim, Hyun-Suk;Kim, Sang-Moon;Kim, Sang-Hyun;Kim, Young-Cheong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.377-384
    • /
    • 2015
  • Purpose: On this study, we measured and compared the dynamic stereoacuity by two-rods test (Howard-Dolman Test) and three-rods test. And we analyzed the correlation between PD and refractive error with dynamic stereoacuity. Methods: Dynamic stereoacuity of two-rods test and three-rods test at 2.5 m distance for 93 adults 93 (50 males, 43 females), mean age of $21.27{\pm}2.32$ (19~32) years old, were measured 5 times for two tests. Results: The mean of dynamic stereoacuity measured by two-rods test and three-rods test were $29.91{\pm}23.03sec$ of arc and $23.75{\pm}21.65sec$ of arc for total subjects, respectively. The mean of male and female were $36{\pm}22.38sec$ of arc and $22.28{\pm}23.79$, respectively. Three-rods test showed better dynamic stereoacuity than two-rods test, but there was no statistically significant difference (p>0.05). For the average standard deviation of PD between 60.63 mm~66.19 mm, dynamic stereoacuity fo two-rod test and three-rod test were $31.48{\pm}24.87sec$ of arc and $31.48{\pm}24.87sec$ of arc, respectively. The results showed statistically significant difference (p<0.05), but the relationship between dynamic stereoacuity and PD was not great. Comparison between two tests on the basis of refractive error, dynamic stereoacuity by three-rods test was better than by two-rods test with no significant difference between both tests (p>0.05) and there was little correlation between refractive error and two dynamic stereoacuity. Conclusions: Three-rods test showing lower stereoacuity than two-rods tests could measure the lower minimum threshold of dynamic stereoacuity. It was found that both tests can be applied to dynamic stereoacuity test as a standard test, and PD and refractive error was found that little effect upon the dynamic stereoacuity. PD and refractive error was found that little effect upon the dynamic stereoacuity.

Comparison and Correlation between Distance Static Stereoacuity and Dynamic Stereoacuity (원거리 정적 입체시와 동적 입체시의 평가 및 상관관계)

  • Kim, Young-Cheong;Kim, Sang-Hyun;Shim, Hyun-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.385-390
    • /
    • 2015
  • Purpose: This study evaluated the static stereoacuity by Distance Randot Stereotest (STEREO OPTICAL. Co., Inc. USA) and the dynamic stereoacuity by three-rods test (iNT, Korea). Criterion and correlation of stereoacuity between both tests and usefulness of two stereotest methods were also evaluated. Methods: For normal adults of 109 (male 61, female 48), mean age of 20.88 (19-32 years) years old, static stereoacuity by using Distance Randot Stereotest at 3 m distance, dynamic stereoacuity by using three-rods test at 2.5 m distance were measured. Results: The mean of distance static stereoacuity was $155.77{\pm}133.11sec$ of arc and the mean of error distance dynamic stereoacuity $11.13{\pm}9.69mm$. With equivalent-conversion stereoacuity of $23.44{\pm}20.96sec$ of arc, there was statistically significant differences (p=0.00) between two dynamic stereoacuity, but correlation was relatively low (${\rho}=0.226$). In the case of dynamic stereoacuity, separated to normal range by criterion of the error distance 20 mm, it showed the error distance of less than 20 mm in 97 subjects(89%) whose average of error distance and conversion mean dynamic stereoacuity were $8.43{\pm}5.10mm$ and $17.68{\pm}10.67sec$ of arc. repectively. The error distance of was equivalent-conversion dynamic stereoacuity 40.99 sec of arc (PD 62 mm basis) was 20 mm. Conclusions: The results of lower correlation between static and dynamic stereoacuity suggest that seterotest should be applied separately to different functions. The results of this study also suggest that Distance Randot Stereotest can be applied to static stereoacuity excluding monocular cues. Three-rods test can be applied to dynamic stereoacuity containing the response of the eye-hand coordination in the daily life of natural vision condition, including the monocular cues. These different approaches canprovide a criterion of the two stereoacuity and parallel use of the two tests would be useful. For dynamic stereoacuity by three-rods test, error distance 20 mm in a normal range of adults can be used as a criteria to get statistical meaning of the results.

The Comparative Assessment of the KVA and Dynamic Stereoacuity (동적시력(KVA)과 동적 입체시의 비교 평가)

  • Kim, Young-Cheong;Shim, Hyun-Suk;Kim, Sang-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.4
    • /
    • pp.519-525
    • /
    • 2014
  • Purpose: On this study, we investigated the relationship between the kinetic visual acuity (KVA) and the dynamic stereoacuity and the effects of anisometropia with measuring KVA and the dynamic stereoacuity. Methods: For 63 adults (male 30, female 33), KVA and the dynamic stereoacuity were measured by using the kinetic visual acuity tester (KOWA AS-4A) and the Howard-Dolman test (H-D test) at distance 2.5 m after conducted full correction of subjects' refractive error respectly. Results: The means of KVA were $0.49{\pm}0.25$ for total subjects, $0.58{\pm}0.26$ for male, $0.40{\pm}0.22$ for female, and LogMAD (Log minimum angle of displacement) dynamic stereoacuities were $1.27{\pm}0.44$($28.44{\pm}25.03sec$ of arc) for total subjects, $1.28{\pm}0.44$($28.23{\pm}23.34sec$ of arc) for male, $1.27{\pm}0.45$($28.63{\pm}26.83sec$ of arc) for female. KVA showed a statistically significant difference between male and female (p=0.00), but dynamic stereoacuity was no significant difference (p=0.97). No significant correlation was present between KVA and dynamic stereoacuity (r=0.03). Also there were no significant differences in the dynamic stereoacuity of the three group which were classified according to the low, middle, high range of KVA (p=0.99). The anisometropia were less than 1 D and over 1 D when divided into two groups, KVA and dynamic stereoacuity showed no significant difference between each (p=0.11, p=0.99). There was no significant correlation between anisometropia and KVA (r=0.33), dynamic stereoacuity (r=0.18) but the correlation between KVA and anisometropia revealed more higer than between dynamic stereoacuity and anisometropia. Conculsions: The KVA for adults showed a significant difference between male and female and male was higher than female for KVA. The dynamic stereoacuity due to the KVA, the KVA and dynamic stereoacuity due to anisometropia were not significant differences between each and also were not great correlations.

Dynamic Visual Acuity and Dynamic Stereoacuity of Athletes and Nonathletes (운동선수와 대학생 남녀의 동체 시력 및 동적 입체시에 관한 비교 연구)

  • Lee, Min-A;Oh, Jae-Man;Jung, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.3
    • /
    • pp.43-49
    • /
    • 2009
  • Purpose: The purpose of this study was to obtain the fundamental data of dynamic visual acuity and dynamic stereoacuity. Methods: The subjects were 20 athletes (high school baseball player) and 40 nonathletes (20 male, 20 female). We assessed static visual acuity, dynamic visual acuity, static stereoacuity and dynamic stereoacuity using rotating mirror projection system and computer program. Results: Three groups had similar static visual acuity and static stereoacuity. On the other hand, the dynamic visual acuity and dynamic stereoacuity showed statistically significant differency. The mean dynamic visual acuity for athletes was 174.80${\pm}$28.70 deg/sec, 137.10${\pm}$16.54 deg/sec for male nonathletes and 111.59${\pm}$15.40 deg/sec for female nonathletes. The mean dynamic stereoacuity for athlets was 234.55${\pm}$19.64, 249.05${\pm}$8.86 for male nonathletes and 247.10${\pm}$14.89 for female nonathletes. The group of athletes had better dynamic visual acuity and dynamic stereoacuity. Conclusions: If the result of this study apply to sports, it will be very useful to improve sports performance.

  • PDF

Assessment of Dynamic Stereoacuity of Adults in their 20s' with Howard-Dolman Test (하워드-돌먼 입체검사를 이용한 20대 성인의 동적 입체시 평가)

  • Shim, Hyun-Suk;Choi, Sun-Mi;Kim, Young-Cheong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.1
    • /
    • pp.61-66
    • /
    • 2015
  • Purpose: In this study, dynamic stereoacuity of 20s' adults were measured by using the Howard-Dolman test(H-D TEST, Bernell, U.S.A), and compared of male and female. And the correlation between dynamic stereoacuity and PD(pupillary distance), and between dynamic stereoacuity and anisometropia caused by difference in the spherical refractive power of the left and right eyes were analyzed. Methods: The mean age of $22.68{\pm}0.50$(20~29)years old, 20s' 63 adults (30 male, 33 female) were conducted for this experiments. After the full correction of subject's refractive error, dynamic stereoacuity was measured 5 times for 1 subject at 2.5 m distance using the H-D test. at 2.5 distance. Results: The mean of dynamic stereoacuity was $28.44{\pm}25.03$ sec of arc for total subjects, $28.23{\pm}23.34$ sec of arc for male, and $28.63{\pm}26.83$ sec of arc for female. In the dynamic stereoacuity classified by the range of inter-pupil distance (IPD), the dynamic stereoacuity was $33.87{\pm}18.53$ sec for the IPD being under 59.80 mm, $26.24{\pm}25.26$ sec of arc for 59.81~66.15 mm, $34.60{\pm}25.65$ sec of arc for over 66.15 mm. However, there were no significant differences between 3 groups (P=0.73, r=0.03). In dynamic stereoacuity classified by the refractive error difference between two eyes, dynamic stereoacuity was $26.81{\pm}24.86$ sec of arc for the under 1 D, $41.45{\pm}24.18$ sec of arc for over 1 D, and there was no significant difference between two groups (P=0.15, r=0.15). Conclusions: Dynamic stereacuity by the H-D test in 20s adults showed that there was no significant differences between male and female, and PD and anisometropia did not have a significant impact upon the dynamic stereoacuity.

Comparison of Dynamic Stereoacuity According to Dominant Eye and Degree of Dominant Eye (우세안의 방향과 강도에 따른 동적 입체시 비교)

  • Shim, Moon-Sik;Shim, Hyun-Suk;Kim, Young-Cheong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.3
    • /
    • pp.227-233
    • /
    • 2016
  • Purpose: On this study, we compared the relationship of dynamic stereoacuity according to the dominant eye, degree of dominant eye, and dominant agreement eye and hand. Methods: For 130 adults (male 70, female 60), mean age of $21.06{\pm}2.21years$ old, dominant eye, degree of dominant eye were measured by objective examination by using the diameter $3.8cm{\times}3.8cm$ thin ring, the dynamic stereoacuity were measured by three-rods test (iNT, Korea). Results: Dynamic stereoacuity according to the dominant eye was center dominant eye without dominance was $14.97{\pm}13.80sec$ of arc, right eye $22.10{\pm}20.01sec$ of arc, left eye $22.31{\pm}20.39sec$ of arc. Dynamic stereoacuity was better when there was no dominance, but the correlation of the dominant eye with dynamic stereoacuity was very low. When Dynamic stereoacuity was separated by in the Center, Mild, Strong, dynamic stereoacuity was $14.97{\pm}13.80sec$ of arc, $20.76{\pm}15.73sec$ of arc and $24.45{\pm}25.60sec$ of arc respectively. The dynamic stereoacuity results were worse when dominance was stonger. However dynamic stereoacuity was better than Center when the degree of dominant eye was rather strong in the dominant left eye. Dynamic stereoacuity according to the dominant eye and hand showed that right eye and hand was $22.63{\pm}20.54sec$ of arc, left eye and hand was $17.36{\pm}10.13sec$ of arc, right eye and left hand was $14.79{\pm}7.05sec$ of arc, left eye and right hand was $22.97{\pm}21.42sec$ of arc so dynamic stereoacuity was comparatively good when the dominant hand was left. Conculsions: Correlation between the dynamic stereoacuity according to the dominant eye, degree of dominant eye was low, however when degree of dominant eye was Center 14.97 sec of arc, Strong 24.45 sec of arc, the dynamic stereoacuity tended to worse when degree of dominant eye was strong. As a result, dominant eye, degree of dominant eye would have to be considered in a more comfortable binocular balance between prescribed for the wearer in binocular vision correction in binocular function such stereoacuity, sports vision training, presbyopia correction and mono vision.

The Effects of Sports Vision Training on Baseball Player's Visual Performance and Baseball Records (스포츠비젼 트레이닝이 시기능 및 야구성적에 미치는 영향)

  • Lee, Min-A;Oh, Jae-Man;Jeong, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.1
    • /
    • pp.87-97
    • /
    • 2010
  • Purpose: The purpose of this study is to investigate the effects of sports vision training on baseball player's visual performance and baseball records. Methods: All subjects were 21 males of high school baseball players, and they participated on eight weeks of sports vision training program. Pre- and post- test results were obtained for static and dynamic visual acuity, static and dynamic stereo acuity, distance and near phoria, fusional reserves, near point of convergence, contrast sensitivity, visual-reaction time. Results: Statical analysis indicated significant improvement in most of mentioned visual variables and baseball records (p<0.001). Conclusions: It can be concluded that the sports vision training program improves visual skills of baseball players, which could lead to improvement in the baseball records. Vison training will be a promotor for baseball player to enhance their performance if proper test instruments and training course is supplied.

A Development of Rich Internet Application in the Space Figure of Elementary Mathematics (초등학교 수학과 입체도형 영역의 학습 RIA의 개발)

  • You, Tae-Ho;Kim, Kab-Su
    • 한국정보교육학회:학술대회논문집
    • /
    • 2008.01a
    • /
    • pp.192-197
    • /
    • 2008
  • 초등학교 수학과 도형 학습은 매우 추상적인 분야로 직관적인 이해를 돕기 위해 다양한 구체적인 조작이 요구되는데, 그 중에서 컴퓨터를 활용한 도형 학습은 학생들의 구체물을 이용한 학습의 한계를 극복할 수 있는 장점이 있다. 특히 Flex와 Flash를 이용하면 입체도형의 가상물의 제작 및 동적인 학습은 물론 사용상의 제약이 적어 시,공간의 한계를 극복할 수 있다. 본 연구에서는 초등학교 수학과 제 7차 교육과정의 입체도형 영역을 분석하여 학습요소를 추출하고 플래시의 드로잉 메서드를 바탕으로 학습요소별로 속성과 메서드를 정의하고 클래스를 설계하여 입체도형 객체를 생성하고 플렉스의 컴포넌트로 구성된 학습 어플리케이션의 틀을 설계하여 입체도형 객체가 플렉스의 어플리케이션 내에서 사용이 가능하도록 설계 개발하였다. 본 연구가 갖는 의의는 첫째, 초등학교 수학과 수준에 맞는 속성과 메서드를 갖도록 개발한 입체도형 객체를 활용하여 학습자의 입체도형에 자유로운 탐구활동 기회를 제공하여 보다 직관적이고 구체적으로 도형학습을 할 수 있도록 돕는다. 둘째, 플렉스를 활용함으로서 학습자의 쉬운 접근을 돕고 학습 어플리케이션 틀을 활용하여 기존에 개발되어 있는 수학과 플래시 파일들을 활용한 다른 수학과 영역의 학습 어플리케이션 설계 및 개발의 시간과 노력을 단축시키는데 있다.

  • PDF

Geospatial Data Display Technique for Non-Glasses Stereoscopic Monitor (무안경식 입체 모니터를 이용한 지형공간 데이터의 디스플레이 기법)

  • Lee, Seun-Geun;Lee, Dong-Cheon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.26 no.6
    • /
    • pp.599-609
    • /
    • 2008
  • Development of computer and electronic technology leads innovative progress in spatial informatics and successful commercialization. Geospatial information technology plays an important role in decision making in various applications. However, information display media are two-dimensional plane that limits visual perception. Understanding human visual processing mechanism to percept stereo vision makes possible to implement three-dimensional stereo image display. This paper proposes on-the-fly stereo image generation methods that are involved with various exterior and camera parameters including exposure station, viewing direction, image size, overlap and focal length. Collinearity equations and parameters related with stereo viewing conditions were solved to generate realisitc stereo imagery. In addition stereo flying simulation scenery was generated with different viewing locations and directions. The stereo viewing is based on the parallax principle of two veiwing locations. This study implemented anaglyphic stereogram, polarization and lenticular stereo display methods. Existing display technology has limitation to provide visual information of three-dimensional and dynamic nature of the real world because the 3D spatial information is projected into 2D plane. Therefore, stereo display methods developed in this study improves geospatial information and applications of GIS by realistic stereo visualization.

Time-dependent Changes of Visual Acuity After Alcohol Ingestion (음주 후 시간경과에 따른 시력의 변화)

  • Kim, Sang-Yoeb;Lee, Sun Haeng;Moon, Byeong-Yeon;Yu, Dong-Sik;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.2
    • /
    • pp.59-62
    • /
    • 2008
  • Purpose: This study was designed to investigate the time-dependent changes of visual acuity after alcohol ingestion. Methods: Both the subjective and objective refraction, distant contrast sensitivity, and three needle tests were carried out at 1 and 3 hours after alcohol ingestion. Results: It was found that the degree of myoptization increased as the blood alcohol level increased in the range of average -0.25D ~ -0.35D when tested 1 and 3 hours after alcohol ingestion. Under the same test conditions the increase in blood alcohol resulted in the reduction in the function of dynamic stereopsis. However, the variation in contrast sensitivity was found to be insignificant for all spatial frequencies. Conclusions: The optician has to be well aware of the fact that alcohol could affect the visual acuity and functional tests, therefore inquiring of the alcohol ingestion prior to visual test can be necessary.

  • PDF