Browse > Article
http://dx.doi.org/10.14479/jkoos.2015.20.3.377

The Comparasion of the Dynamic Stereoacuity with Two-Rods Test and Three-Rods Test  

Shim, Hyun-Suk (Dept. of Ophthalmic Optics, Gwangju Health University)
Kim, Sang-Moon (Dept. of Ophthalmic Optics, Gwangju Health University)
Kim, Sang-Hyun (Dept. of Ophthalmic Optics, Gwangju Health University)
Kim, Young-Cheong (Dept. of Ophthalmic Optics, Gwangju Health University)
Publication Information
Journal of Korean Ophthalmic Optics Society / v.20, no.3, 2015 , pp. 377-384 More about this Journal
Abstract
Purpose: On this study, we measured and compared the dynamic stereoacuity by two-rods test (Howard-Dolman Test) and three-rods test. And we analyzed the correlation between PD and refractive error with dynamic stereoacuity. Methods: Dynamic stereoacuity of two-rods test and three-rods test at 2.5 m distance for 93 adults 93 (50 males, 43 females), mean age of $21.27{\pm}2.32$ (19~32) years old, were measured 5 times for two tests. Results: The mean of dynamic stereoacuity measured by two-rods test and three-rods test were $29.91{\pm}23.03sec$ of arc and $23.75{\pm}21.65sec$ of arc for total subjects, respectively. The mean of male and female were $36{\pm}22.38sec$ of arc and $22.28{\pm}23.79$, respectively. Three-rods test showed better dynamic stereoacuity than two-rods test, but there was no statistically significant difference (p>0.05). For the average standard deviation of PD between 60.63 mm~66.19 mm, dynamic stereoacuity fo two-rod test and three-rod test were $31.48{\pm}24.87sec$ of arc and $31.48{\pm}24.87sec$ of arc, respectively. The results showed statistically significant difference (p<0.05), but the relationship between dynamic stereoacuity and PD was not great. Comparison between two tests on the basis of refractive error, dynamic stereoacuity by three-rods test was better than by two-rods test with no significant difference between both tests (p>0.05) and there was little correlation between refractive error and two dynamic stereoacuity. Conclusions: Three-rods test showing lower stereoacuity than two-rods tests could measure the lower minimum threshold of dynamic stereoacuity. It was found that both tests can be applied to dynamic stereoacuity test as a standard test, and PD and refractive error was found that little effect upon the dynamic stereoacuity. PD and refractive error was found that little effect upon the dynamic stereoacuity.
Keywords
Two-Rods Test; Three-Rods Test; Howard-Dolman Test; Dynamic stereoacuity; Dynamic stereoacuity test;
Citations & Related Records
Times Cited By KSCI : 4  (Citation Analysis)
연도 인용수 순위
1 Von Noorden GK. Binocular vision and ocular motility, 5th Ed. St. Louis: Mosby, 1996;8-40.
2 Wong BP, Woods RL, Peli E. Stereoacuity at distance and near. Optom Vis Sci. 2002;79(12):771-778.   DOI
3 Marsh WR, Rawlings SC, Mumma JV. Evaluation of clinical stereoacuity tests. Ophthalmology. 1980;87(12):1265-1272.   DOI
4 Min BM, Park WC. The relationship between visual acuity and titmus stereoacuity. J Korean Ophthalmol Soc. 1987;28(6):1339-1342.
5 Tyler CW. A stereoscopic view of visual processing streams. Vision Res. 1990;30(11):1877-1895.   DOI
6 Hart WM. Adler's physiology of the eye, 9th Ed. St. Louis: Mosby, 1992;773-810.
7 Laby DM, Kirschen DG. Dynamic stereoacuity; Preliminary results and normative data for new test for the quantitative measurement of motion in depth. Binocular Vis & Eye Mus Surg. 1995;10(3):191-200.
8 Lim KH, Hong HJ. Dynamic stereoacuity in normal individuals. J korean Ophthalmol Soc. 2000;41(11):2408-2414.
9 Lee MA, Oh JM, Jung JH. Dynamic visual acuity and dynamic stereoacuity of athletes and nonathletes. J Korean Ophthalmic Opt Soc. 2009;14(3):43-49.
10 Shim HS, Choi SM, Kim YC. Assessment of dynamic stereoacuity of adults in their 20s' with Howard-Dolman test. J Korean Ophthalmic Opt Soc. 2015;20(1):61-66.   DOI
11 Kim YC. Shim HS, Kim SH. The comparative assessment of the KVA and dynamic stereoacuity. J Korean Ophthalmic Opt Soc. 2014;19(4):519-525.   DOI
12 Matsuo T, Negayama R, Sakata H, Hasebe K. Correlation between depth perception by three-rods test and stereoacuity by distance randot stereotest. Strabismus. 2014;22(3):133-137.   DOI
13 Borish, Irvin M. Borish's clinical refraction, 2nd Ed. Elsevier, 2006;921-922.
14 Howard HJ. A Test for the Judgment of Distance. Trans Am Ophthalmol Soc. 1919;17:195-235.
15 Jin YH. Strabismology, 1st Ed. Ulsan: UUP, 1999;72,174-176.
16 Lee MA, Oh JM, Jung JH. The effects of sports vision training on baseball player's visual performance and baseball records. J Korean Ophthalmic Opt Soc. 2010;15(1):87-97.
17 Campos EC, Enoch JM. Amount of aniseikonia compatible with fine binocular vision: some old and new concepts. J Pediatr Ophthalmol Strabismus. 1980;17(1):44-47.
18 Lovasik JV, Szymkiw M. Effects of aniseikonia, anisometropia, accommodation, retinal illuminance, and pupil size on stereopsis. Invest Ophthalmol Vis Sci. 1985;26(5):741-750.
19 Kham KT, Lee YH. The effect of inter-pupillary distance on stereopsis. Korean J. Cognitive Science. 2003;14(3):37-49.
20 Colenbrander MC. The limits of stereoscopis vision. Ophthalmologica. 1948;115(6):363-366.