• 제목/요약/키워드: 독립모달공간 제어기법

검색결과 6건 처리시간 0.022초

독립모달공간 제어기법에서 작동기 수의 절감에 대한 연구

  • 황재혁;김준수;박명호
    • 소음진동
    • /
    • 제7권2호
    • /
    • pp.273-279
    • /
    • 1997
  • Reduction of number of actuators for independent modal space control In this paper, a new modified independent modal space control (IMSC), which relaxes the fundamental hardware limitation of IMSC, is suggested to handle the vibration and attitude control problem for flexible large structures. This method has adapted a new switching algorithm between controlled modes and a novel design technique for modal control force. The main advantage of this method is to minimize the discontinuity of the modal control forces and to assure the asymptotic stability of the closed-loop systems. This process is shown to be simple and efficient in a realistic example of vibration control of a cantiloever beam. It has been found that the modified IMSC suggested in this paper, which can reduce the number of actuators, is highly excellent compared to other previous methods in terms of the performance and stability of the vibration control systems.

  • PDF

파라메터오차 및 모달필터오차에 대한 독립모달공간 제어기법의 강인성 해석 (Robustness of Independent Modal Space Control for Parameter and Modal Filter Errors)

  • 황재혁;김준수
    • 대한기계학회논문집A
    • /
    • 제20권11호
    • /
    • pp.3549-3559
    • /
    • 1996
  • In this study, the effect of parameter and modal filter errors on the vibration control characteristics of flexible structures is analyzed for IMSC ( Independent Modal Space Control). If the control force is designed on the basis of the mathematical model with the parameter and modal filter errors, the closed-loop performance of the vibration control system will be degraded depending on the magnitude of the errors. An asymptotic stability condition of the system with parameter and modal filter errors has more significant effect on the stability condition of the system with parameter and modal filter errors has been drived using Lyapunov approach. It has been found that modal filter error has more significant effect on the stability of closed-loop system than parameter error does. The extent of the response deviation of the closed-loop system is also derived and evaluated using operator thchniques.

파라메타 오차에 강인한 독립모달공간 제어기법에 대한 연구 (A Study on the Robust Controller in Independent Modal space for Parameter Errors)

  • 황재혁;김준수;박대성;박명호
    • 소음진동
    • /
    • 제6권5호
    • /
    • pp.595-605
    • /
    • 1996
  • If the control force designed on the basis of the mathematical model with parameter errors is applied to control the actual system, the closed-loop performance of the actual system will be degraded depending on the degree of the errors, In this study, the effect of parameter errors on the robustness of several natural controls has been analyzed and compared. Every asymptoic stability condition for the natural controls has been derived using Lyapunov approach, and the characteristics of the stability conditions has also been compared. The extent of deviation of the closed-loop performance from the designed one for the natural controls is derived using operator techniques, and evaluated by numerical method. It has been found that the optimal control, acceleration feedback control, and acceleration-position feedback control among the considered natural controls would be robust one with respect to the parameter errors.

  • PDF

가상수동형 제어기를 이용한 독립모달공간 제어기법 (Design of Independent Modal Space Controller using Virtual Passive Approach)

  • 황재혁;박홍조;유병성
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1997년도 춘계학술대회논문집; 경주코오롱호텔; 22-23 May 1997
    • /
    • pp.301-307
    • /
    • 1997
  • In this study, a new modified independent modal space control (IMSC), which relaxes the fundamental hardware limitation of IMSC, is suggested to handle vibration control problems using a virtual passive controller. This method has adapted a new stable switching algorithm between controlled modes and a virtual vibration absorber as a virtual passive controller in the independent modal space. It has been found that the new modified IMSC suggested in this paper, which can reduce the number of actuators, is shown to be simple and efficient in a realistic example of vibration control of a cantilever beam.

  • PDF

독립모달공간 제어기법에서 작동기 수의 절감에 대한 연구 (Reduction of Number of Actuators for Independent Modal Space Control)

  • 황재혁;김준수;박명호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1996년도 추계학술대회논문집; 한국과학기술회관, 8 Nov. 1996
    • /
    • pp.166-174
    • /
    • 1996
  • In this paper, a new modified independent modal space control(IMSC), which relaxes the fundamental hardware limitation of IMSC, is suggested to handle the vibration and attitude control problem for flexible large structures. This method has adapted a new switching algorithm between controlled modes and a novel design technique for modal control force. The main advantage of this method is to minimize the discontinuity of the modal control forces and to assure the asymptotic stability of the closed-loop systems. This process is shown to be simple and efficient in a realistic example of vibration control of a cantilever beam. It has been found that the modified IMSC suggested in this paper, which can reduce the number of actuators, is highly excellent compared to other previous methods in terms of the performance and stability of the vibration control systems.

  • PDF

독립된 모달공간에서 양 위치피드백 제어기법의 강인성 (Robustness of Positive Position Feedback Control in the Independent Modal Space)

  • 황재혁;백승호
    • 소음진동
    • /
    • 제4권2호
    • /
    • pp.177-185
    • /
    • 1994
  • In this study, the effect of parameter errors on the closed-loop behavior of flexible structure is analyzed for IMSC(Independent Modal Space Control) with PPF(Positive Position Feedback). If the control force designed on the basis of structure model with the parameter errors is applied to control the actual system, the closed-loop performance of the actural system will be degraded depending on the degree of the errors. An asymptotic stability condition has been derived, using Lyapunov approach, which is independent of the dynamic characteristics of the structure being controlled. The extent of deviation of the closed-loop performance from the designed one is also derived and evaluated using operator techniques. It has been found that the extent of the deviation is proportational to the magnitude of the parameter errors, and that the proportional coefficient depends on the control algorithm.

  • PDF