• Title/Summary/Keyword: 도플러 속도

Search Result 294, Processing Time 0.023 seconds

Experimental Study on the Evolution of Tip Vortex Structures Generated by a Two-Bladed Rotor (2개의 블레이드로 구성된 회전익 끝와류들의 간섭 특성)

  • Sohn, Yong-Joon;Park, Byung-Ho;Han, Yong-Oun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.7
    • /
    • pp.709-715
    • /
    • 2011
  • In order to observe the wake interaction between tip vortices generated by a two-bladed rotor with slightly different pitch angles, the velocity components of the tip vortices were measured by using a two-dimensional LDV system. It was observed that the swirl velocity components of the ensuing blade deviated from the Vatistas' n = 2 vortex model and the axial velocity components of the preceding blade deviated from the Gaussian profile. It was also found that in the wake-age range of $200^{\circ}$ to $240^{\circ}$, the filament of the ensuing blade tip vortex was stretched as result of the closing in of two vortices. The results from these observations suggest the possibility that a similar wake interaction is generated in actual rotor blades, especially, in the ones with articulated hubs.

Feature of Spray Transport and Atomization from Two-Phase Swirling Jet with Air-to-Liquid Mass Ratio (공기액체질량비에 따른 이류체 선회형 분사의 분무거동 및 미립화 특성)

  • Lee, Sam-Goo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.8 no.2
    • /
    • pp.39-45
    • /
    • 2004
  • Experiments were performed in a two-phase swirling spray facility that has been described elsewhere. Measurements of spray transport and drop size distribution are analyzed over wide ranges of air to liquid mass flow ratios, utilizing four different internal mixing pneumatic nozzles. The spatial distributions of mean velocities. fluctuating velocities, and velocity-diameter correlation were quantitatively analyzed. Also, the exponential correlation curves were obtained with ALR along the spray centerline, which indicated an approximately identical formulation regardless of ALR. It indicated that the atomization characteristics were remarkably superior in the case of 30o of swirl angle with higher ALR. Among other things. nozzle configuration is one of the significant parameters affecting spray phenomena from an internal mixing nozzle. Turbulence intensities are increasingly degenerated with an increase of nozzle configuration, allowing a rapid increment of drop size distribution.

Discovery of Sub-pc Scale Plasma Torus in the Nearby Radio Galaxy 3C 84 with the KVN and VERA Array (KaVA)

  • Wajima, Kiyoaki;Kino, Motoki;Kawakatu, Nozomu
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.2
    • /
    • pp.32.4-33
    • /
    • 2016
  • 활동성은하핵(AGN)의 거대 블랙홀 주변에 존재하는 플라스마 디스크의 구조나 물리적인 상태를 관측으로 직접 찾는 것은 AGN 중심부분에서의 제트 형성, 방출과정이나 에너지 수송과정을 조사하기 위해 중요한다. 지금껏 주로 센치미터파장 영역의 다주파 VLBI 관측으로 우리은하에서 가까운 AGN 속에 존재하는 10 pc 정도의 플라스마 디스크가 발견되어 있다만, AGN의 활동성을 정하고 있는 1 pc 이하의 스케일에서의 디스크 구조를 직접 관측한 결과는 아직 없다. 우리는 2015년8월부터 KVN 및 KVN과 일본 VERA로 구성되는 한일공동 VLBI 관측망(KaVA)을 이용해서 전파 은하 3C 84(z = 0.0176, 1 mas = 0.36 pc)의 밀리미터파장 모니터링을 진행하고 있다. KVN과 KaVA를 이용하면 1 pc 이하의 스케일로 3C 84의 중심구조를 고감도에서 분해할 수 있다. 이번 발표에서는 KVN 및 KaVA로 거의 동시에 실시한 관측결과를 중심으로 보고한다. 관측은 2016년2월22일(KaVA 43 GHz) 및 23일(KVN 86 GHz)에 실시되었다. 양 주파수의 이미지에서 종래의 센치미터 ~ 밀리미터파장 VLBI관측으로도 검출되어 있는 중심핵(C1) 및 남쪽에 약 3 mas 떨어져서 위치하는 로브(C3) 성분 뿐만 아니라 C1으로부터 북쪽에 약 2.5 mas 떨어져서 위치하는 새로운 성분(N1)을 검출하였다. N1의 검출 수준은 43, 86 GHz 모두 $6{\sigma}$이며, 양 주파수 사이에서 광학적으로 두꺼운 스펙트럼을 가지고 있다. 과거의 관측으로 측정된 C3의 겉보기 속도는 빛의 속도의 약 23%이며, 남북 로브의 구조와 운동의 대칭을 가정하면 N1이 도플러 분사출 효과 때문에 어두워지고 있는 가능성은 낮다. 따라서 C3에 대응하는 북쪽 N1로브로부터의 복사가 블랙홀 주변의 플라스마 디스크로 인해 저주파수에서 강한 흡수를 받고 있는 결과고 생각된다.

  • PDF

Performance Analysis of MMSE-Based Equalization of IMT-Advanced System in Time-Varing Channels (IMT-Advanced 시스템의 시변 채널에서의 MMSE 기반 등화 성능 분석)

  • Park, Sung-Joon
    • Journal of the Korea Society for Simulation
    • /
    • v.20 no.4
    • /
    • pp.91-96
    • /
    • 2011
  • As the user's demand for ultra high-speed wireless internet has increased, the standardization, research and development of future mobile communication systems have been done for several years. IMT-Advanced system which is called fourth generation mobile communication should support the data rate of 1 Gbps for nomadic users and 100 Mbps for mobile users. Also, the system should hold call connection at the mobile speed of 350 km/h. Meanwhile, since Doppler spread is linearly proportional to mobile speed, high mobility leads to the increase of interference between subcarriers and the deterioration of detection performance consequently. In this paper, we evaluate and analyze detection probability with respect to equalization methods in time-varying channels under system parameters complying with IMT-Advanced requirements. According to computer simulation conducted by varying mobile speed and code rate, MMSE based equalization can mitigate performance degradation of IMT-Advanced system considerably in time-varying channels.

Comparative Performance of Differential Space-Time Block Codes Over Time-Selective Fading Channels (시변 페이딩 채널에서 검파방식에 따른 차분 공간-시간 블록 부호의 성능 비교)

  • Kang, Sung-Ho;Kim, Young-Ju;Lee, In-Sung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.8
    • /
    • pp.356-361
    • /
    • 2006
  • We present the performance of differential space-time block decoders. which does not require the channel state information. We suggest the structure of the multiple blocks differential space time decoders. which does not require the channel state information, and analyze the Performances. In quasi-static flat fading channels. the Performance of multiple blocks differential detection (MD-STC) outperforms that of 2 blocks(D-STC) by 1.5dB. But in the time-selective fading channels due to Doppler frequency $(f_d)$, the performance of MD-STC degrades as the vehicular speed is greater than 200km/hr in 802.16e systems, where the data transmission rate is 144kbps.

The Study of Aliasing and Incidence Angle Dependence of Doppler Image on Humeral Artery (상완동맥 Doppler 영상의 입사각 의존성과 Aliasing에 관한 연구)

  • Kim, Sang-Jin;Ji, Tae-Jeong
    • Journal of radiological science and technology
    • /
    • v.31 no.4
    • /
    • pp.379-387
    • /
    • 2008
  • Among methods to eliminate aliasing effects, the method of increasing velocity scale gradually eliminated the phenomenon in which the direction of the blood flow appeared in reverse. It was done by increasing the velocity scale while maintaining other parameters in the same state. The method of setting the Doppler angle to $0^{\circ}$ did not show significant changes in the wave pattern of the spectrum according to the angle. In actual ultrasonography tests, more accurate tests are expected to be carried out by applying variations to the velocity scale under the considerations of speed, accuracy, and convenience of the examination. The results showed that blood flow velocity increases exponentially according to the Doppler Angle. When the angle goes over $70^{\circ}$, the velocity value increases to an unmeasurable state. This indicates that in blood flow velocity measurements, the blood flow velocity is very dependent on the Doppler Angle. It also shows that the error increases when the incidence angle to the direction of blood flow exceeds $60^{\circ}$, and when the angle exceeds $70^{\circ}$, the error becomes even greater. In addition, he experiment results showed that an angle below $60^{\circ}$ is appropriate and for blood flow velocity measurements in extremity vessels, the most appropriate Doppler Angle is from $45^{\circ}$ to $60^{\circ}$.

  • PDF

Shear-wave elasticity imaging with axial sub-Nyquist sampling (축방향 서브 나이퀴스트 샘플링 기반의 횡탄성 영상 기법)

  • Woojin Oh;Heechul Yoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.5
    • /
    • pp.403-411
    • /
    • 2023
  • Functional ultrasound imaging, such as elasticity imaging and micro-blood flow Doppler imaging, enhances diagnostic capability by providing useful mechanical and functional information about tissues. However, the implementation of functional ultrasound imaging poses limitations such as the storage of vast amounts of data in Radio Frequency (RF) data acquisition and processing. In this paper, we propose a sub-Nyquist approach that reduces the amount of acquired axial samples for efficient shear-wave elasticity imaging. The proposed method acquires data at a sampling rate one-third lower than the conventional Nyquist sampling rate and tracks shear-wave signals through RF signals reconstructed using band-pass filtering-based interpolation. In this approach, the RF signal is assumed to have a fractional bandwidth of 67 %. To validate the approach, we reconstruct the shear-wave velocity images using shear-wave tracking data obtained by conventional and proposed approaches, and compare the group velocity, contrast-to-noise ratio, and structural similarity index measurement. We qualitatively and quantitatively demonstrate the potential of sub-Nyquist sampling-based shear-wave elasticity imaging, indicating that our approach could be practically useful in three-dimensional shear-wave elasticity imaging, where a massive amount of ultrasound data is required.

Change of Cerebral Blood Flow during Tilt Tests in Children with Vasovagal Syncope (혈관미주 신경성 실신 소아에서 기립경사 검사 동안에 뇌혈류 변화)

  • Kim, Su Jung;Yom, Hye Won;Hong, Young Mi;Yoo, Jung Hyen;Lee, Sook Hee;Kim, Chong Hee
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.10
    • /
    • pp.983-988
    • /
    • 2003
  • Purpose : Syncope appears to be common. However, the mechanism of syncope is not clear. Increased vagal activity and withdrawal of sympathetic stimulation cause hypotension, bradycardia and finally loss of consciousness. The purpose of this study was to evaluate changes of cerebral blood flow velocity, blood pressure, and heart rate during tilt test in children with vasovagal syncope. Methods : Sixty four children with a past history of syncope were evaluated. The stand up test was performed for 15 minutes after a rest at supine position for 10 minutes, followed by an $80^{\circ}$ tilt test lasting 45 minutes. If presyncope(lightheadedness, nausea, blurred vision, or sweating) or syncope occurred, the study was discontinued. 12-lead electrocardiography, echocardiography, and electroencephalography were performed. Transcranial Doppler study was performed at the middle cerebral artery with 2 MHz continuous Doppler probe in 10 children with positive tilt test. Systolic, diastolic, mean cerebral blood flow velocity, integral, and pulsatility index were measured with blood pressure, heart rate, and $O_2$ saturation. Results : The positive rate of tilt test was 31.3%(20/64). Systolic, diastolic, and mean cerebral blood flow velocity decreased significantly in absence of hypotension or bradycardia during presyncope. Time velocity integral of cerebral artery also decreased significantly. Conclusion : Decreased cerebral blood flow velocity can predict the presyncope manifestation. Impairment of autoregulation of cerebral blood flow might play an important role in the pathophysiology of vasovagal syncope.

A Study on the Fetal Umbilical Artery Doppler Blood Flow Velocity Waveforms in Normal Pregnancy (정상 임신에서 Doppler 초음파를 이용한 제대동맥 혈류속도 파형에 관한 연구)

  • Bae, Cheol-Seong;Kwun, Gee-Jin;Lee, Doo-Jin;Park, Yoon-Kee;Lee, Sung-Ho;Cho, Kil-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.8 no.1
    • /
    • pp.63-71
    • /
    • 1991
  • Noninvasive techniques for antenatal detection of the fetal development and well-being such as biophysical profile, non-stress and stress test remain major challenges in modem obstetric practice. To obtain and analyze umbilical artery velocity waveform by pulsed-wave doppler ultrasound, a total of 160 determinations were carried out on 157 normal pregnant women between 16th to 41st week gestation. The ratio of peak systolic to end-diastolic flow velocity(S/D ratio), pulsatility index and resistance index were measured as indices of the resistance in feto-placental circulation. The results were as follows : As gestation advances, the, mean values for peak systolic and end-diastolic velocities raised progressively. As gestation advances, the mean values for the S/D ratio declined progressively, exhibiting high diastolic flow velocity caused by low resistance. Pulsatility index, and resistance index were also declined progressively, as gestation advances. The analysis of umbilical artery blood flow velocity waveforms provides a new noninvasive technique to evaluate fetal development and well-being, and may be expected a reliable method for assessment of fetal life.

  • PDF

A frame structure of modified ATSC system for terrestial 3D HDTV broadcasting (지상파 3D HDTV 방송을 위한 수정된 ATSC 전송 시스템의 프레임 구조에 대한 연구)

  • Oh, Jong-Gyu;Kim, Joon-Tae
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.257-259
    • /
    • 2010
  • 본 논문에서는 지상파 3D HDTV 방송 서비스를 제공하기 위해 수정된 ATSC (Advanced Television Systems Committee) 전송 시스템 [2]을 위한 시변다중경로채널에 강인한 프레임 구조를 제안하고 성능을 측정하였다. 수정된 ATSC 전송 시스템 [2]은 기존 ATSC 전송 시스템[1]의 채널 부호화부를 수정하고, 변조 성상도를 증가 시키면서 적정한 수준의 TOV (Threshold of Visibility)에서의 전송 용량 증대 가능성을 확인하였다. 이를 토대로, 증가된 전송 데이터 전송률에 대한 순수 데이터 전송률을 최대한 보장하면서 시변다중경로채널에서 효율적으로 채널을 추정하고 복구하기 위해, ISI (Inter Symbol Interference)를 방지하기 위한 프레임 헤더의 보호구간에 알려진 PN (Pseudorandom Noise) 심벌을 삽입하였다. PN 심벌을 보호 구간에 이용할 경우 시간 영역에서 채널 임펄스 응답 (CIR: Channel Impulse Response)을 추정하여, 주파수 영역에서의 채널 보상을 가능케 하여 정확한 채널 추정 및 보상을 수행할 수 있다. 또한 수신기의 속도에 따른 다양한 최대 도플러 주파수가 존재하는 채널에 강인한 프레임 구조들을 제안하였다. 컴퓨터 시뮬레이션을 통해 수정된 ATSC 전송 시스템에 제안된 프레임 구조를 적용하여 TU (Typical Urban)-6 채널에서의 SER (Symbol Error Rate) 성능을 측정하였다.

  • PDF