• Title/Summary/Keyword: 도로 시설물 관리

Search Result 447, Processing Time 0.026 seconds

A study on bicycle storage improvement in Seoul -Focusing on the bicycle storage in Seoul subway transit links- (서울시 자전거 보관소의 개선방안 -서울시 지하철 연계 환승 보관소를 중심으로-)

  • Park, Yeun-Kyung;Kim, Seung-In
    • Journal of Digital Convergence
    • /
    • v.14 no.12
    • /
    • pp.405-411
    • /
    • 2016
  • Seoul city is publishing new plans to increase modal share rate of bicycle every year, such as, maintaining bicycle related facilities. But bicycle's modal share rate in Seoul stayed same for the last decade and people are still facing difficulties using bicycle related facilities. These problems are causing bicycle usage as connecting transportation of public transit to decrease. This study looked at the high bicycle modal countries, such as, Netherlands, Germany and Japan to find applicable solutions by analyzing cases and comparing them with cases of highly populated subway station of Sindorim in Seoul. For example, in Germany and Netherlands there is bicycle-parking system to help bikers to access subway easier, in Japan there is underground bicycle parking tower to safely keep high volume of bicycles with in small space. For Seoul city to increase its modal share rate, they should look at problems from users' prospective and solve it by fixing it and improving the services, not by making more facilities.

Development of Low-Power IoT Sensor and Cloud-Based Data Fusion Displacement Estimation Method for Ambient Bridge Monitoring (상시 교량 모니터링을 위한 저전력 IoT 센서 및 클라우드 기반 데이터 융합 변위 측정 기법 개발)

  • Park, Jun-Young;Shin, Jun-Sik;Won, Jong-Bin;Park, Jong-Woong;Park, Min-Yong
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.34 no.5
    • /
    • pp.301-308
    • /
    • 2021
  • It is important to develop a digital SOC (Social Overhead Capital) maintenance system for preemptive maintenance in response to the rapid aging of social infrastructures. Abnormal signals induced from structures can be detected quickly and optimal decisions can be made promptly using IoT sensors deployed on the structures. In this study, a digital SOC monitoring system incorporating a multimetric IoT sensor was developed for long-term monitoring, for use in cloud-computing server for automated and powerful data analysis, and for establishing databases to perform : (1) multimetric sensing, (2) long-term operation, and (3) LTE-based direct communication. The developed sensor had three axes of acceleration, and five axes of strain sensing channels for multimetric sensing, and had an event-driven power management system that activated the sensors only when vibration exceeded a predetermined limit, or the timer was triggered. The power management system could reduce power consumption, and an additional solar panel charging could enable long-term operation. Data from the sensors were transmitted to the server in real-time via low-power LTE-CAT M1 communication, which does not require an additional gateway device. Furthermore, the cloud server was developed to receive multi-variable data from the sensor, and perform a displacement fusion algorithm to obtain reference-free structural displacement for ambient structural assessment. The proposed digital SOC system was experimentally validated on a steel railroad and concrete girder bridge.

An Assessment on the Urban Riverfront in Shincheon, Daegu - Focused on a Universal Design Concept - (대구광역시 신천의 친수공간 평가 연구 - 유니버설디자인 개념을 중심으로 -)

  • Choi, Dong-Sik;Moon, Ji-Won;Kim, Shang-Hee
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.2
    • /
    • pp.1-14
    • /
    • 2012
  • The purpose of this study is to derive a desirable riverfront construction plan to me for the activities of citizens through the evaluation and analysis of the urban riverfront space from the perspective of universal design. Therefore, previous studies were examined in order to induce evaluation tools that bhve been grafted from the universal design concept; in addition, a field survey was conducted in Shincheon, Daegu, which was selected as the study target, in order to induce problems and improvement directions from the perspective of universal design. The major results can be summarized as follows. (1) In the 'fairness' aspect, all the items such as installation of integrated functional signage, showing pictures, symbols, foreign language signs, and restroom entrances signage were determined to be 'All Unsuitable' for all sections; and therefore, it is necessary to improve the fairness of usage for everybody. (2) In the 'Functionality(Usability)' aspect, all items such as installation of bicycle paths beside access roads, installation of integrated functional signs, and night light signs were determined to be 'All Unsuitable' for all sections; therefore, it is necessary to improve the functionalities of these facilities. (3) In the 'Convenience' aspect, all items such as the installation of bicycle parking areas, continuous rest facilities, and back and ann support(handles) at resting facilities were determined to be 'All Unsuitable' for many sections; therefore, it is necessary to improve these facilities for the convenience of usage. (4) In the 'Information(Recognizability)' aspect, all items such as showing pictures, symbols, foreign languages and installation of night light signs, and restroom entrances signage were determined to be 'All Unsuitable' for all sections; therefore, it is necessary to improve the recognizability to minimize misunderstandings and confusion. (5) In the 'Safety' aspect, all items such as the installation of safe pedestrian paths in parking areas, using anti-slip and shock absorption materials on restroom floors, and the continuous installation of pedestrian paths that are separate from bicycle paths were determined to be 'All Unsuitable' for all sections; therefore, it is necessary to improve the safety to prevent accidents. (6) In the 'Amenity' aspect, access roads, parking areas, hygiene facilities, convenience facilities, and waterside facilities for many sections were determined to be 'All Unsuitable'; therefore, it is necessary to conduct more concentrated hygiene management. (7) In the 'Accessibility(Mobility)' aspect, all items such as the installation of safe pedestrian paths in parking areas, and continuous pedestrian paths that are separate from bicycle paths were determined to be 'All Unsuitable' for all sections; therefore, it is necessary to improve the accessibility to provide safety and convenience. (8) In the 'Durability' aspect, access roads, parking areas, rest facilities, convenience facilities, fitness facilities, and waterside facilities were determined to be 'All Unsuitable' for many sections, therefore, it is necessary to improve sunken or damaged areas by inspecting facilities by section.

Design and Management Direction of Smart Park for Smart Green City (스마트 그린시티 구현을 위한 스마트 공원 설계·관리 방향)

  • Kim, Yong-Gook;Song, Yu-Mi;Cho, Sang-kyu
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.48 no.6
    • /
    • pp.1-15
    • /
    • 2020
  • The purpose of this study is to propose a direction for designing and managing a smart park for realizing a smart green city and to present measures in the landscape field to foster related industries. The research process is as follows. First, the concept of a smart park was operationally defined through a literature review, and three principles to be considered in the process of creation and management were established. Second, in terms of the three principles, problems and implications for improvement were derived through an analysis of established cases of smart parks in new and pre-existing cities. Third, a pool of designs and management standards for each spatial component of a smart park was prepared through literature and case studies, and then further refined through brainstorming with experts in related fields. Fourth, measures were suggested to the government, local governments, and the landscape field to promote smart park creation and management. The main findings are as follows. First, the concept of a smart park is defined as "a park that contributes to securing the social, economic, and environmental sustainability of cities and local communities by supporting citizens' safe and pleasant use of parks and improving the management and operational efficiency by utilizing the digital, environment, and material technologies." Second, the three principles of smart parks are to improve the intrinsic value of parks, to improve the innovative functions of parks to solve urban problems, and to make the design, construction, and management process smart. Third, improvement implications were derived through the analysis of cases of smart parks creation in new and pre-existing cities. Fourth, the directions for smart park design and management were suggested in five aspects: green area, hydroponic facility area, road and plaza area, landscape facilities area, and park design method. Fifth, as for policy implications for revitalizing the construction and management of smart parks, the development of smart park policy business models by city growth stage, and park type, the promotion of pilot projects, the promotion of smart park projects in connection with the Korean New Deal policy, and smart park policies led by landscape experts were presented.

Comparison of the CO2 Emissions of Buildings using Input-Output LCA Model and Hybrid LCA Model (산업연관분석법 기반 LCA 모델과 Hybrid LCA 모델의 건축물 이산화탄소 배출량 평가결과 비교)

  • Hong, Taehoon;Ji, Changyoon
    • Korean Journal of Construction Engineering and Management
    • /
    • v.15 no.4
    • /
    • pp.119-127
    • /
    • 2014
  • This study aims to determine whether or not the input output life cycle assessment (I-O LCA) model can be used to assess the carbon dioxide (CO2) emission of buildings in initial planning phase. To ensure this end, this study proposed I-O LCA model which is the simplified LCA model and Hybrid LCA model which is the detailed LCA model, and then assessed and compared the CO2 emission of six case projects (three apartment complexes and three educational facilities) using the two LCA model. The results of the case study showed that the CO2 emissions assessed by the I-O LCA is significantly similar to the CO2 emission assessed by the Hybrid LCA model. The similarity of results from both LCA models was 78.2-86.3% in apartment complexes and 59.9-84.8% in educational facilities. However, the CO2 emissions from I-O LCA model were smaller than the CO2 emissions from Hybrid LCA model in case study. Nevertheless, the case study showed that the I-O LCA model was capable of assessing the CO2 emission of buildings quite appropriately although the I-O LCA model is the simplified LCA model which considers only the construction cost. The I-O LCA model is expected to be a useful tool for assessing the CO2 emission of buildings in initial planning phase.

Study on Establishment of a Monitoring System for Long-term Behavior of Caisson Quay Wall (케이슨 안벽의 장기 거동 모니터링 시스템 구축 연구 )

  • Tae-Min Lee;Sung Tae Kim;Young-Taek Kim;Jiyoung Min
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.5
    • /
    • pp.40-48
    • /
    • 2023
  • In this paper, a sensor-based monitoring system was established to analyze the long-term behavioral characteristics of the caisson quay wall, a representative structural type in port facilities. Data was collected over a period of approximately 10 months. Based on existing literature, anomalous behaviors of port facilities were classified, and a measurement system was selected to detect them. Monitoring systems were installed on-site to periodically collect data. The collected data was transmitted and stored on a server through LTE network. Considering the site conditions, inclinometers for measuring slope and crack meters for measuring spacing and settlement were installed. They were attached to two caissons for comparison between different caissons. The correlation among measured data, temperature, and tidal level was examined. The temperature dominated the spacing and settlement data. When the temperature changed by approximately 50 degrees, the spacing changed by 10 mm, the settlement by 2 mm, and the slope by 0.1 degrees. On the other hand, there was no clear relationship with tidal level, indicating a need for more in-depth analysis in the future. Based on the characteristics of these collected database, it will be possible to develop algorithms for detecting abnormal states in gravity-type quay walls. The acquisition and analysis of long-term data enable to evaluate the safety and usability of structures in the event of disasters and emergencies.

A Study on the Development and Utilization of Indoor Spatial Information Visualization Tool Using the Open BIM based IFC Model (개방형 BIM 기반 IFC 모델을 이용한 실내공간정보 시각화 도구개발 및 활용방안 연구)

  • Ryu, Jung Rim;Mun, Son Ki;Choo, Seung Yeon
    • Spatial Information Research
    • /
    • v.23 no.5
    • /
    • pp.41-52
    • /
    • 2015
  • MOLIT (Minister of Land, Infrastructure and Transport) authorized Indoor Spatial Information as Basic spatial information in 2013. It became a legal evidence for constructing and managing Indoor Spatial Information. Although it has a little advantage to utilize as service level that Indoor Spatial Information by laser scan or measurement, it has a lot of problems such as consuming many resources, requiring additional progresses for inputting Object Information. In conclusion, it is inefficient to utilize for the maintenance and domestic AEC/FM field. The purposes of this study is to output Indoor Spatial Information by operating IFC model which based on open BIM and to improve availability of Indoor Spatial Information with data visualization. The open-sources of IFC Exporter, a inner program of Revit (Autodesk Inc), is used to output Indoor Spatial Information. Directs 3D Library is also operated to visualize Indoor Spatial Information. It is possible to inter-operate between XML format and the objects of Indoor Spatial Information. It can be utilized in various field as well. For example COBie linkage in facility management, construction of geo-database using air-photogrammetry of UAV (Unmaned Areal Vehicle), the simulation of large-scale military operations and the simulation of large-scale evacuation. The method that is purposed in this study has outstanding advantages such as conformance with national spatial information policy, high level of interoperability as indoor spatial information objects based on IFC, convenience of editing information, light level of data and simplifying progress of producing information.

A Study on Benefit Cost Analysis of Chungju UIS (청주시 도시정보시스템의 비용편익분석 연구)

  • Kim, Kwang Ju
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.6 no.4
    • /
    • pp.1-15
    • /
    • 2003
  • Recently, urban information system(UIS) has been developed and utilized by local governments in Korea and has become a key means of urban informatization of local governments. When UIS is conducted only for FM oriented internal utilization regardless of its cost-efficiency, however, its cost-benefit structure could be distorted seriously. The study utilizes benefit cost analysis technique and applied the technique to a model case of Chungju UIS selected by National GIS team. Chungju City developed its GIS for the management of roads and urban planning in 1993. At its beginning, the system was an efficient model with relatively strong cost-benefit structure and could produce positive net benefit 10 years' after its construction. When the city began to develop its facility management with the financial assistance from central government in 1998, however, its cost-benefit structure became distorted. As a result, it is delayed for the UIS to produce positive net benefit until the year of 2015. Using benefit cost ratio, discount rate and Mobile GIS, the study also conducts a sensitivity analysis.

  • PDF

Damage Assessment Technique for Bridge Structures By Moving Load Tests and Optical Displacement Measurements (광변위 계측과 주행하중시험기법에 의한 교량구조의 손상도 추정기법)

  • Lee, Hyeong-Jin;Kim, Jong-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.1
    • /
    • pp.769-777
    • /
    • 2015
  • In this paper, a damage assessment technique using a moving load test and optical sensors was studied to overcome the deficiency of measurement information in bridge maintenance. Continuous displacements by applying the reciprocal theorem to the test can make the assessment simpler and more practical. Numerical and experimental studies were performed to show the efficiency and accuracy of the proposed technique as well as the possibility of a more realistic assessment for large infrastructure. The results showed that the assessed damage levels are quite accurate, and similar to the exact values in actual damage locations, even in the experiments. The proposed technique is useful and practical for both detecting damage locations and damage quantities.

Development of Visual Confirmation Device for Anchor Tensile Force (앵커 긴장력 상시확인을 위한 육안확인장치 개발)

  • Yoon, Hwan Hee;Lee, Yong Joo;Oh, Dong Wook;Kim, Dong Hyun;Jung, Hyuk Sang
    • Tunnel and Underground Space
    • /
    • v.28 no.5
    • /
    • pp.493-511
    • /
    • 2018
  • This paper deals with visual confirmation device for tensile force verification in order to cope with tensile force loss of ground anchor. Ground anchors are constructed to ensure the stability of social infrastructure facilities, but continuous loss of tensile force is seriously concerned about safety of the facilities. This requires the maintenance of the anchors, but the current measuring of residual tensile force is done by sampling, taking into account economic aspects, which limits precision. In this paper, conducted a conceptual design, tensile experiment, and field test for the purpose of developing an anchor tensile force visual device to check the tensile force of the anchors.