• Title/Summary/Keyword: 데이터 변환

Search Result 3,693, Processing Time 0.038 seconds

Establishment of Reference Value of Insulin Using the Statistical Analysis (통계적 분석을 통한 Insulin의 정상 참고치 설정)

  • Kim, Whe-Jung;Yoon, Pil-Young;Shin, Young-Goon;Yoo, Seon-Hee;Cho, Shee-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.143-146
    • /
    • 2010
  • Purpose: Insulin is involved in carbohydrate metabolism and also it's very important because it increases storage of glycogen, synthesis of fatty acids, absorption of amino acid, synthesis of protein. Insulin is clinically useful when we evaluate fasting patients in hypoglycemia, classify and predict diabetes, assess the activity of ${\beta}$-cell, research insulin resistance. We are going to increase usability of insulin assay by establishing normal reference value according to statistical analysis. Material & Method: We selected 6,648 patients who visited asan health medical center from May to August in 2008. We set exclusion criteria as family of diabetes, diabetes medication, the past history of blood glucose rise, more than 100 mg/dL in normal fasting blood glucose, outside the scope of BMI 18.5~22.9 $kg/m^2$, and more than HbA1c 6.5%. We determine whether the subgroup is portioned as sex and age or not and establish normal reference value by conducting statistical analysis as Bayesian's method and Hoffman's method. Result: Portioning of subgroup as sex and age is not needed. By statistical analysis of Bayesian method, results 1.5-11.0 uIU/mL. By statistical analysis of Hoffman method, results 1.8~12.8 uIU/mL. Conclusion: We established 1.8~12.8 uIU/mL as Insulin normal reference value by Hoffman method. This is a similar value with reporting reference value 1.7~11.8 uIU/mL in kit. This will enhance the usability of insulin assay by establishing normal reference value.

  • PDF

Sputtering방식을 이용한 Indium Thin oxide박막의 넓이에 따른 X-ray 검출기 특성 연구

  • Kim, Dae-Guk;Sin, Jeong-Uk;O, Gyeong-Min;Kim, Seong-Heon;Lee, Yeong-Gyu;Jo, Seong-Ho;Nam, Sang-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.321-322
    • /
    • 2012
  • 의료용 방사선 장비는 초기의 아날로그 방식의 필름 및 카세트에서 진보되어 현재는 디지털 방식의 DR (Digital Radiography)이 널리 사용되며 그에 관한 연구개발이 활발히 진행되고 있다. DR은 크게 간접방식과 직접방식의 두 분류로 나눌 수 있는데, 간접방식은 X선을 흡수하면 가시광선으로 전환하는 형광체(Scintillator)를 사용하여 X선을 가시광선으로 전환하고, 이를 Photodiode와 같은 광소자로 전기적 신호로 변환하여 방사선을 검출하는 방식을 말하며, 직접 방식은 X선을 흡수하면 전기적 신호를 발생 시키는 광도전체(Photoconductor)를 사용하여 광도전체 양단 전극에 고전압을 인가한 형태를 취하고 있는 가운데, X선이 조사되면 일차적으로 광도전체 내부에서 전자-전공쌍(Electron-hole pair)이 생성된다. 이들은 광도전체 양단의 인가되어 있는 전기장에 의해 전자는 +극으로, 전공은 -극으로 이동하여 아래에 위치한 Active matrix array을 통해 방사선을 검출하는 방식이다. 본 연구에서는 직접방식 X-ray 검출기에서 활용되는 a-Se을 ITO (Indium Thin oxide) glass 상단에 Thermal evaporation증착을 이용하여 두께 $50{\mu}m$, 33 넓이로 증착 시킨 다음, a-Se상단에 Sputtering증착을 이용하여 ITO를 11 cm, 22 cm, $2.7{\times}2.7cm$ 넓이로 증착시켜 상하부의 ITO를 Electrode로 이용하여 직접방식의 X-ray검출기 샘플을 제작하였다. 제작 과정 중 a-Se의 Thermal evaporation증착 시, 저진공 $310^{-3}_{Torr}$, 고진공 $2.210^{-5}_{Torr}$에서 보트의 가열 온도를 두 번의 스텝으로 나누어 증착 시켰다. 첫 번째 스텝 $250^{\circ}C$, 두 번째 스텝은 $260^{\circ}C$의 조건으로 증착하여 보트 내의 a-Se을 남기지 않고 전량을 소모할 수 있었으며, 스텝간의 온도차를 $10^{\circ}C$로 제어하여 균일한 박막을 형성 할 수 있었다. Sputtering증착 시, 저진공 $2.510^{-3}$, 고진공 $310^{-5}$에서 Ar, $O_2$를 사용하여 100 Sec간 플라즈마를 생성시켜 ITO를 증착하였다. 제작된 방사선 각각의 검출기 샘플 양단의 ITO에 500V의 전압을 인가하고, 진단 방사선 범위의 70 kVp, 100 mA, 0.03 sec 조건으로 X-ray를 조사시켜 ITO넓이에 따른 민감도(Sensitivity)와 암전류(Dark current)를 측정하였다. 측정결과 민감도(Sensitivity)는 X-ray샘플의 두께에 따른 $1V/{\mu}m$ 기준 시, 증착된 ITO의 넓이가 11 cm부터 22 cm, $2.7{\times}2.7cm$까지 각각 $7.610nC/cm^2$, $8.169nC/cm^2$, $6.769nC/cm^2$로 22 cm 넓이의 샘플이 가장 높은 민감도를 나타내었으나, 암전류(Dark current)는 $1.68nA/cm^2$, $3.132nA/cm^2$, $5.117nA/cm^2$로 11 cm 넓이의 샘플이 가장 낮은 값을 나타내었다. 이러한 데이터를 SNR (Signal to Noise Ratio)로 합산 하였을 시 104.359 ($1{\times}1$), 60.376($2{\times}2$), 30.621 ($2.7{\times}2.7$)로 11 cm 샘플이 신호 대 별 가장 우수한 효율을 나타냄을 알 수 있었다. 따라서 ITO박막의 면적이 클수록 민감도는 우수하나 그에 따른 암전류의 증가로 효율이 떨어짐을 검증 할 수 있었으며, 이는 ITO면적이 넓어짐에 따른 저항의 증가로 암전류에 영향을 끼침을 할 수 있었다. 본 연구를 통해 a-Se의 ITO 박막 면적에 따른 전기적 특성을 검증할 수 있었다.

  • PDF

Design and Implementation of Medical Information System using QR Code (QR 코드를 이용한 의료정보 시스템 설계 및 구현)

  • Lee, Sung-Gwon;Jeong, Chang-Won;Joo, Su-Chong
    • Journal of Internet Computing and Services
    • /
    • v.16 no.2
    • /
    • pp.109-115
    • /
    • 2015
  • The new medical device technologies for bio-signal information and medical information which developed in various forms have been increasing. Information gathering techniques and the increasing of the bio-signal information device are being used as the main information of the medical service in everyday life. Hence, there is increasing in utilization of the various bio-signals, but it has a problem that does not account for security reasons. Furthermore, the medical image information and bio-signal of the patient in medical field is generated by the individual device, that make the situation cannot be managed and integrated. In order to solve that problem, in this paper we integrated the QR code signal associated with the medial image information including the finding of the doctor and the bio-signal information. bio-signal. System implementation environment for medical imaging devices and bio-signal acquisition was configured through bio-signal measurement, smart device and PC. For the ROI extraction of bio-signal and the receiving of image information that transfer from the medical equipment or bio-signal measurement, .NET Framework was used to operate the QR server module on Window Server 2008 operating system. The main function of the QR server module is to parse the DICOM file generated from the medical imaging device and extract the identified ROI information to store and manage in the database. Additionally, EMR, patient health information such as OCS, extracted ROI information needed for basic information and emergency situation is managed by QR code. QR code and ROI management and the bio-signal information file also store and manage depending on the size of receiving the bio-singnal information case with a PID (patient identification) to be used by the bio-signal device. If the receiving of information is not less than the maximum size to be converted into a QR code, the QR code and the URL information can access the bio-signal information through the server. Likewise, .Net Framework is installed to provide the information in the form of the QR code, so the client can check and find the relevant information through PC and android-based smart device. Finally, the existing medical imaging information, bio-signal information and the health information of the patient are integrated over the result of executing the application service in order to provide a medical information service which is suitable in medical field.

Design and Performance Evaluation of Selective DFT Spreading Method for PAPR Reduction in Uplink OFDMA System (OFDMA 상향 링크 시스템에서 PAPR 저감을 위한 선택적 DFT Spreading 기법의 설계와 성능 평가)

  • Kim, Sang-Woo;Ryu, Heung-Gyoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.3 s.118
    • /
    • pp.248-256
    • /
    • 2007
  • In this paper, we propose a selective DFT spreading method to solve a high PAPR problem in uplink OFDMA system. A selective characteristic is added to the DFT spreading, so the DFT spreading method is mixed with SLM method. However, to minimize increment of computational complexity, differently with common SLM method, our proposed method uses only one DFT spreading block. After DFT, several copy branches are generated by multiplying with each different matrix. This matrix is obtained by linear transforming the each phase rotation in front of DFT block. And it has very lower computational complexity than one DFT process. For simulation, we suppose that the 512 point IFFT is used, the number of effective sub-carrier is 300, the number of allowed sub-carrier to each user's is 1/4 and 1/3 and QPSK modulation is used. From the simulation result, when the number of copy branch is 4, our proposed method has more than about 5.2 dB PAPR reduction effect. It is about 1.8 dB better than common DFT spreading method and 0.95 dB better than common SLM which uses 32 copy branches. And also, when the number of copy branch is 2, it is better than SLM using 32 copy branches. From the comparison, the proposed method has 91.79 % lower complexity than SLM using 32 copy branches in similar PAPR reduction performance. So, we can find a very good performance of our proposed method. Also, we can expect the similar performance when all number of sub-carrier is allocated to one user like the OFDM.

Assessment of Water Control Model for Tomato and Paprika in the Greenhouse Using the Penman-Monteith Model (Penman-Monteith을 이용한 토마토와 파프리카의 증발산 모델 평가)

  • Somnuek, Siriluk;Hong, Youngsin;Kim, Minyoung;Lee, Sanggyu;Baek, Jeonghyun;Kwak, Kangsu;Lee, Hyondong;Lee, Jaesu
    • Journal of Bio-Environment Control
    • /
    • v.29 no.3
    • /
    • pp.209-218
    • /
    • 2020
  • This paper investigated actual crop evapotranspiration (ETc) of tomato and paprika planted in test beds of the greenhouse. Crop water requirement (CWR) is the amount of water required to compensate ETc loss from the crop. The main objectives of the study are to assess whether the actual crop watering (ACW) was adequate CWR of tomato and paprika and which amount of ACW should be irrigated to each crop. ETc was estimated using the Penman-Monteith model (P-M) for each crop. ACW was calculated from the difference of amount of nutrient supply water and amount of nutrient drainage water. ACW and CWR of each crop were determined, compared and assessed. Results indicated CWR-tomato was around 100 to 1,200 ml/day, while CWR-paprika ranged from 100 to 500 ml/day. Comparison of ACW and CWR of each crop found that the difference of ACW and CWR are fluctuated following day of planting (DAP). However, the differences could divide into two phases, first the amount of ACWs of each crop are less than CWR in the initial phase (60 DAP) around 500 ml/day and 91 ml/day, respectively. Then, ACWs of each crop are greater than the CWR after 60 DAP until the end of cultivation approximately 400 ml/day in tomato and 178 ml/day in paprika. ETc assessment is necessary to correctly quantify crop irrigation water needs and it is an accurate short-term estimation of CWR in greenhouse for optimal irrigation scheduling. Thus, reducing ACW of tomato and paprika in the greenhouse is a recommendation. The amount of ACW of tomato should be applied from 100 to 1,200 ml/day and paprika is 100 to 500 ml/day depend on DAP.

Three dimensional analysis of tooth movement using different sizes of NiTi wire on NiTi scissors-bite corrector (NiTi scissors-bite corrector의 와이어 굵기에 따른 3차원적 치아 이동 양상)

  • Jeon, Hyun-Ju;Park, Sun-Hyung;Jung, Sang-Hyuk;Chun, Youn-Sic
    • The korean journal of orthodontics
    • /
    • v.39 no.1
    • /
    • pp.43-53
    • /
    • 2009
  • Objective: The purpose of this study was to compare the difference in three dimensional tooth movement using three different wire sizes($0.018{\times}0.025-in,\;0.016{\times}0.022-in$ 0.016-in) on a NiTi scissors-bite corrector. Methods: Computed tomography(CT) images of the experimental model before and after tooth movement were taken and reconstructed into three dimensional models for superimposition. The direction and the amount of tooth movement were measured and analyzed statistically. Results: The lingual and intrusive movements of the crown of the maxillary second molar were increased as the size of the NiTi wire increased. The roots of the maxillary second metals moved buccally except for the 0.016-in group. The intrusive movement of the roots of the maxillary second molars was increased as the size of the NiTi wire increased. Due to the use of orthodontic mini-implants, anchorage loss was under 0.2 mm on average. Conclusions: The $0.018{\times}0.025-in$ NiTi wire was most effective in lingual and intrusive movement of the maxillary second molar which was in scissors-bite position. Indirect skeletal anchorage with a single orthodontic mini-implant was rigid enough to prevent anchorage loss.

A Study on the Effects of BIM Adoption and Methods of Implementationin Landscape Architecture through an Analysis of Overseas Cases (해외사례 분석을 통한 조경분야에서의 BIM 도입효과 및 실행방법에 관한 연구)

  • Kim, Bok-Young;Son, Yong-Hoon
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.45 no.1
    • /
    • pp.52-62
    • /
    • 2017
  • Overseas landscape practices have already benefited from the awareness of BIM while landscape-related organizations are encouraging its use and the number of landscape projects using BIM is increasing. However, since BIM has not yet been introduced in the domestic field, this study investigated and analyzed overseas landscape projects and discussed the positive effects and implementation of BIM. For this purpose, landscape projects were selected to show three effects of BIM: improvement of design work efficiency, building of a platform for cooperation, and performance of topography design. These three projects were analyzed across four aspects of implementation methods: landscape information, 3D modeling, interoperability, and visualization uses of BIM. First, in terms of landscape information, a variety of building information was constructed in the form of 3D libraries or 2D CAD format from detailed landscape elements to infrastructure. Second, for 3D modeling, a landscape space including simple terrain and trees was modeled with Revit while elaborate and complex terrain was modeled with Maya, a professional 3D modeling tool. One integrated model was produced by periodically exchanging, reviewing, and finally combining each model from interdisciplinary fields. Third, interoperability of data from different fields was achieved through the unification of file formats, conversion of differing formats, or compliance with information standards. Lastly, visualized 3D models helped coordination among project partners, approval of design, and promotion through public media. Reviewing of the case studies shows that BIM functions as a process to improve work efficiency and interdisciplinary collaboration, rather than simply as a design tool. It has also verified that landscape architects could play an important role in integrated projects using BIM. Just as the introduction of BIM into the architecture, engineering and construction industries saw great benefits and opportunities, BIM should also be introduced to landscape architecture.

Development of Deep Learning Structure to Improve Quality of Polygonal Containers (다각형 용기의 품질 향상을 위한 딥러닝 구조 개발)

  • Yoon, Suk-Moon;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.25 no.3
    • /
    • pp.493-500
    • /
    • 2021
  • In this paper, we propose the development of deep learning structure to improve quality of polygonal containers. The deep learning structure consists of a convolution layer, a bottleneck layer, a fully connect layer, and a softmax layer. The convolution layer is a layer that obtains a feature image by performing a convolution 3x3 operation on the input image or the feature image of the previous layer with several feature filters. The bottleneck layer selects only the optimal features among the features on the feature image extracted through the convolution layer, reduces the channel to a convolution 1x1 ReLU, and performs a convolution 3x3 ReLU. The global average pooling operation performed after going through the bottleneck layer reduces the size of the feature image by selecting only the optimal features among the features of the feature image extracted through the convolution layer. The fully connect layer outputs the output data through 6 fully connect layers. The softmax layer multiplies and multiplies the value between the value of the input layer node and the target node to be calculated, and converts it into a value between 0 and 1 through an activation function. After the learning is completed, the recognition process classifies non-circular glass bottles by performing image acquisition using a camera, measuring position detection, and non-circular glass bottle classification using deep learning as in the learning process. In order to evaluate the performance of the deep learning structure to improve quality of polygonal containers, as a result of an experiment at an authorized testing institute, it was calculated to be at the same level as the world's highest level with 99% good/defective discrimination accuracy. Inspection time averaged 1.7 seconds, which was calculated within the operating time standards of production processes using non-circular machine vision systems. Therefore, the effectiveness of the performance of the deep learning structure to improve quality of polygonal containers proposed in this paper was proven.

Analysis of Skin Color Pigments from Camera RGB Signal Using Skin Pigment Absorption Spectrum (피부색소 흡수 스펙트럼을 이용한 카메라 RGB 신호의 피부색 성분 분석)

  • Kim, Jeong Yeop
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.11 no.1
    • /
    • pp.41-50
    • /
    • 2022
  • In this paper, a method to directly calculate the major elements of skin color such as melanin and hemoglobin from the RGB signal of the camera is proposed. The main elements of skin color typically measure spectral reflectance using specific equipment, and reconfigure the values at some wavelengths of the measured light. The values calculated by this method include such things as melanin index and erythema index, and require special equipment such as a spectral reflectance measuring device or a multi-spectral camera. It is difficult to find a direct calculation method for such component elements from a general digital camera, and a method of indirectly calculating the concentration of melanin and hemoglobin using independent component analysis has been proposed. This method targets a region of a certain RGB image, extracts characteristic vectors of melanin and hemoglobin, and calculates the concentration in a manner similar to that of Principal Component Analysis. The disadvantage of this method is that it is difficult to directly calculate the pixel unit because a group of pixels in a certain area is used as an input, and since the extracted feature vector is implemented by an optimization method, it tends to be calculated with a different value each time it is executed. The final calculation is determined in the form of an image representing the components of melanin and hemoglobin by converting it back to the RGB coordinate system without using the feature vector itself. In order to improve the disadvantages of this method, the proposed method is to calculate the component values of melanin and hemoglobin in a feature space rather than an RGB coordinate system using a feature vector, and calculate the spectral reflectance corresponding to the skin color using a general digital camera. Methods and methods of calculating detailed components constituting skin pigments such as melanin, oxidized hemoglobin, deoxidized hemoglobin, and carotenoid using spectral reflectance. The proposed method does not require special equipment such as a spectral reflectance measuring device or a multi-spectral camera, and unlike the existing method, direct calculation of the pixel unit is possible, and the same characteristics can be obtained even in repeated execution. The standard diviation of density for melanin and hemoglobin of proposed method was 15% compared to conventional and therefore gives 6 times stable.

A Relative Study of 3D Digital Record Results on Buried Cultural Properties (매장문화재 자료에 대한 3D 디지털 기록 결과 비교연구)

  • KIM, Soohyun;LEE, Seungyeon;LEE, Jeongwon;AHN, Hyoungki
    • Korean Journal of Heritage: History & Science
    • /
    • v.55 no.1
    • /
    • pp.175-198
    • /
    • 2022
  • With the development of technology, the methods of digitally converting various forms of analog information have become common. As a result, the concept of recording, building, and reproducing data in a virtual space, such as digital heritage and digital reconstruction, has been actively used in the preservation and research of various cultural heritages. However, there are few existing research results that suggest optimal scanners for small and medium-sized relics. In addition, scanner prices are not cheap for researchers to use, so there are not many related studies. The 3D scanner specifications have a great influence on the quality of the 3D model. In particular, since the state of light reflected on the surface of the object varies depending on the type of light source used in the scanner, using a scanner suitable for the characteristics of the object is the way to increase the efficiency of the work. Therefore, this paper conducted a study on nine small and medium-sized buried cultural properties of various materials, including earthenware and porcelain, by period, to examine the differences in quality of the four types of 3D scanners. As a result of the study, optical scanners and small and medium-sized object scanners were the most suitable digital records of the small and medium-sized relics. Optical scanners are excellent in both mesh and texture but have the disadvantage of being very expensive and not portable. The handheld method had the advantage of excellent portability and speed. When considering the results compared to the price, the small and medium-sized object scanner was the best. It was the photo room measurement that was able to obtain the 3D model at the lowest cost. 3D scanning technology can be largely used to produce digital drawings of relics, restore and duplicate cultural properties, and build databases. This study is meaningful in that it contributed to the use of scanners most suitable for buried cultural properties by material and period for the active use of 3D scanning technology in cultural heritage.