• Title/Summary/Keyword: 덕트손실

Search Result 61, Processing Time 0.024 seconds

Study on Flow Deflection of Duct and Raw Coal Separation Screen (덕트 및 원탄 선별망 유동 편향에 관한 연구)

  • Semyeong Lim;Hyunbum Park
    • Journal of Aerospace System Engineering
    • /
    • v.17 no.4
    • /
    • pp.28-33
    • /
    • 2023
  • In this study, computational fluid dynamics was used to analyze the flow bias generated as air supplied by a fan passes through ducts, piping, and a coal separation screen. The flow bias of the air flow is mostly caused by the spatial characteristics of the fan volute and duct, and the internal baffle and the coal separation screen at the outlet cause strong pressure losses that dampen the flow bias. ANSYS CFX was used for computational fluid dynamics, and since the baffle and the coal separation screen are shaped like perforated plates with many small holes uniformly distributed, actual modeling for analysis was not possible. Therefore, the Porous Loss Model was applied. The evaluation of the flow bias was analyzed based on the velocity distribution of the Porous Loss Model at the outlet surface of the coal separation screen obtained from the computational fluid dynamics results.

Aerodynamic Analysis of Automotive HVAC Duct for Enhancement of Cooling/Heating Performance (자동차 냉/난방 성능 향상을 위한 공기조화 덕트의 기류해석)

  • Ju, Jae-Woo;Lee, Ki-Don;Heo, Man-Woong;Kim, Kwang-Yong;Park, June-Kyu;Yun, Jung-Hwan;Kim, Hong-Bin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.1
    • /
    • pp.23-28
    • /
    • 2012
  • In the present work, numerical analyses of air flow in HVAC duct have been carried out for enhancement of cooling/heating performance. For the analyses, three-dimensional Reynolds-averaged Navier-Stokes equations have been solved with the shear stress transport turbulence model. The numerical results were validated in comparison with the experimental data. Based on the numerical results, the HVAC duct was designed to reduce the pressure loss. The modified duct geometry shows largely reduced pressure drop in comparison with the reference geometry. And, through modified duct shape, the performance of air conditioning has been enhanced.

Evaluation of Noise Reduction Performance of HVAC System for Ships (선박용 HVAC 시스템의 소음저감성능 평가)

  • Kim, Sang-Ryul;kim, Hyun-Sil;Kim, Jae-Seung;Kim, Bong-Ki;Lee, Sung-Hyun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.8
    • /
    • pp.497-503
    • /
    • 2010
  • In this paper, evaluation of noise reduction performance of HVAC system for ships by means of HVAC mock-up system is presented. Test is done for six different types of HVAC elements including room unit, silencer, etc. It is found that when diameter of silencer is small and air flow is large, flow noise degrades insertion loss. However, as diameter of silencer becomes larger, the effect of flow noise becomes smaller, and insertion loss up to 25 dB is measured. It is observed that insertion loss of diffuser type room unit is usually between zero and 10 dB, whereas that of the nozzle type room unit can be down to - 15 dB. In addition, it is shown that changing duct arrangement can reduce cabin noise by up to 2 dB, and providing same air flow to each room unit is crucial for generating less noise.

High Bit-Rates Quantization of the First-Order Markov Process Based on a Codebook-Constrained Sample-Adaptive Product Quantizers (부호책 제한을 가지는 표본 적응 프로덕트 양자기를 이용한 1차 마르코프 과정의 고 전송률 양자화)

  • Kim, Dong-Sik
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.49 no.1
    • /
    • pp.19-30
    • /
    • 2012
  • For digital data compression, the quantization is the main part of the lossy source coding. In order to improve the performance of quantization, the vector quantizer(VQ) can be employed. The encoding complexity, however, exponentially increases as the vector dimension or bit rate gets large. Much research has been conducted to alleviate such problems of VQ. Especially for high bit rates, a constrained VQ, which is called the sample-adaptive product quantizer(SAPQ), has been proposed for reducing the hugh encoding complexity of regular VQs. SAPQ has very similar structure as to the product VQ(PQ). However, the quantizer performance can be better than the PQ case. Further, the encoding complexity and the memory requirement for the codebooks are lower than the regular full-search VQ case. Among SAPQs, 1-SAPQ has a simple quantizer structure, where each product codebook is symmetric with respect to the diagonal line in the underlying vector space. It is known that 1-SAPQ shows a good performance for i.i.d. sources. In this paper, a study on designing 1-SAPQ for the first-order Markov process. For an efficient design of 1-SAPQ, an algorithm for the initial codebook is proposed, and through the numerical analysis it is shown that 1-SAPQ shows better quantizer distortion than the VQ case, of which encoding complexity is similar to that of 1-SAPQ, and shows distortions, which are close to that of the DPCM(differential pulse coded modulation) scheme with the Lloyd-Max quantizer.

Study on Development of Inducing Airflow Duct System for Kitchen Hood Using Ejector Method (이젝터 기술을 활용한 주방후드용 기류유인 덕트 시스템의 개발에 관한 연구)

  • Son, Yu-Ra;Hong, Seong-Gyu;Yang, Jeong-Hoon
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.6
    • /
    • pp.27-40
    • /
    • 2019
  • Kitchen hoods are limited in discharging all contaminants produced during cooking. Contaminants that have not been discharged can rise to the upper part of the kitchen and become stacked. To solve this problem, there is a way to increase the air volume of the kitchen hood, but there are limits, so a new system is required. This study proposes the Duct System (IADK : Inducing Airflow Duct system for Kitchen hood )through 3D printers and experiments. To do this, the pressure is measured to verify the three levels of air volume provided by the kitchen hood. To check the degree of loss of flow in the existing kitchen hood system, install flexible ducts alone to measure the pressure. Change the internal diameter and type of connection of the IADK and measure the pressure. The air pressure, static pressure difference, and loss factor are calculated and analyzed using the pressure measured through the experiment.

An Experimental Investigation on Noise Reduction Performance of the Absorption and the Resonance Type Duct Silencers (흡음형과 공명형 덕트 소음기의 소음저감 성능에 관한 실험적 고찰)

  • Lee, Young-Sup;Chung, Kwang-Seop;Lee, Dong-Hoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.12
    • /
    • pp.897-901
    • /
    • 2010
  • A silencer has been widely used for the purpose of suppressing the noises propagated from duct of air conditioning system. The absorption type silencer is usually applied to reduce the noise with high frequency bandwidth. On the order hand, the resonance type silencer is applied to reduce the noise with low-middle frequency bandwidth. The insertion loss of silencer is measured in the reverberation room. The cut-off frequency of reverberation room is 100 Hz. The insertion loss of absorption type silencer is more larger than that for resonance type silencer regardless of changing the flow velocity.

Optimum Design for Inlet and Outlet Locations of Rectangular Expansion Chamber for Improving Acoustic Performance (사각형 단순 확장소음기의 성능향상을 위한 입$\cdot$출구 위치의 최적설계)

  • 김봉준;정의봉;황상문
    • Journal of KSNVE
    • /
    • v.9 no.4
    • /
    • pp.738-746
    • /
    • 1999
  • The performance of muffler can be improved for a frequency range of interest by moving inlet and outlet locations. And optimal location of inlet and outlet can be determined to improve the acoustic performance. The optimum design using FEM, however, may take a very long time and be very hard to take inlet and outlet locations as design variables. In this paper, the acoustic performance of reactive type single expansion chamber muffler is predicted using higher order mode theory. The sensitivity analysis of transmission loss with respect to the location of inlet and outlet is suggested. And the acoustic power transmission coefficient for a frequency of interest is used as cost function. Optimum location of inlet and outlet is determined to minimize cost function by using SUMT algorithm.

  • PDF

TURBULENCE HEAT TRANSFER ENHANCEMENT TECHNIQUE FOR SQUARE DUCT WITH HIGH ASPECT RATIO (종횡비가 큰 사각 덕트내 난류 유동의 대류 열전달 증진 기술에 대한 연구)

  • Lee, Chan-Yong;Shin, Seung-Won;Chung, Ha-Seung;Park, Seung-Ho
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.305-307
    • /
    • 2010
  • In this study, we develop a method to achieve heat transfer enhancement inside a square duct with high aspect ratio without changing any inner structures. Especially, a method to lower the possible maximum temperature is suggested if constant heat flux is provided to single surface of square duct. Knowing the fact that heat transfer rate is inversely proportional to flow area, we proposed tapered channel concept which uses narrower gap toward the flow exit where the maximum temperature is expected. To maintain equivalent power consumption, inlet section has been enlarged. To verify the proposed concept, experimental tests have been performed.

  • PDF

Low Frequency Noise Reduction Inside Duct by Using Membrane (박막을 이용한 저주파수 영역 덕트 소음 저감 방법)

  • 김양한
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.11
    • /
    • pp.1083-1090
    • /
    • 2004
  • Two noise reduction systems are proposed in order to overcome the geometric restriction of the reactive muffler such as an expansion chamber. First, membrane is installed as a part of a duct wall and an air cavity is covered outside membrane. Second, membrane is installed inside a duct, which gives no volume change of the duct. Structural-acoustic coupling between membrane and fluid inside the cavity and duct causes rapid impedance mismatching and thereby reflected wave. Theoretical prediction is conducted by using modal expansion approach. The results are compared with the experimental results, which show better noise reduction performance than an expansion chamber.

Low frequency noise reduction inside duct by using membrane (박막을 이용한 저주파수 영역 덕트 소음 저감 방법)

  • 전종훈;김양한
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.474-479
    • /
    • 2004
  • Two noise reduction systems are proposed in order to overcome the geometric restriction of the reactive muffler such as an expansion chamber. First, membrane is installed as a part of a duct wall and an air cavity is covered outside membrane. Second, membrane is installed inside a duct, which gives no volume change of the duct. Structural-acoustic coupling between membrane and fluid inside the cavity and duct causes rapid impedance mismatching and thereby reflected wave. Theoretical prediction is conducted by using modal expansion approach. The results are compared with the experimental results, which show better noise reduction performance than an expansion chamber.

  • PDF