• Title/Summary/Keyword: 댐 제체

Search Result 62, Processing Time 0.027 seconds

Numerical analysis of dam breaking problem using SPH (제체의 갑작스런 붕괴로 인한 충격파 수치해석 - SPH (Smoothed Particle Hydrodynamics)를 중심으로)

  • Cho, Yong Jun;Kim, Gweon Su
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.3B
    • /
    • pp.261-270
    • /
    • 2008
  • Even though there is a great deal of progress in a numerical method of high caliber like SPH, it is very rarely deployed in a water resources community. Despite the great stride in computing environment, depth averaged approach like a nonlinear shallow equation is still efficient tool for flood routing in large watershed, but it can give some misleading information like the inundation height of flood. In this rationale, we numerically simulate the flow into the dry channel, dry channel with an obstacle triggered by the collapse of a two dimensional water column using SPH (Smoothed Particle Hydrodynamics) in order to boost the application of numerical method of high caliber like SPH in a water resources community. As a most severe test of the robustness of SPH, we also carry out the simulation of the flow through a clearance into the wet channel driven by the rapid removal of a water gate. As a hydrodynamic model, we used the Navier-Stokes equation, a numerical integration of which was carried out using SPH. To verify the validity of newly proposed numerical model, we compare the numerically simulated flow with the others in the literature mainly from VOF and MAC, and hydraulic experiments by Martin and Moyce (1952), Koshizuka et al. (1995) and Janosi et al. (2004). It was shown that agreements between the numerical results in this study and hydraulic experiments are remarkable.

Analysis on Flood Control Effect of Siphon Spillway by Reservoir Routing (저수지 추적을 통한 사이펀 여수로의 홍수조절 효과 분석)

  • Ko, Suhyeon;Kim, Jaeyoung;Lee, Giha
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.11
    • /
    • pp.55-63
    • /
    • 2013
  • Agricultural small dam reservoirs in Korea are vulnerable to flooding because of insufficient flood control capacity and deterioration such that reservoir water level is likely to rise rapidly and a large amount of water release quickly to downstream without flood warning. In this study, we performed hydrologic analysis to estimate design flood(200 years return period ${\times}1.2$) and also evaluated the effect of siphon spillway as a structural countermeasure for flood control and mitigation by applying reservoir routing to the Jipyeong reservoir, located in Sangju, Korea. The results show that the design flood was calculated at $284.3m^3/s$, and water level and water release decreased by 40cm and $91m^3/s$, respectively.

A Study on Geothermal Characteristics of Dam Body and Seepage Flow (댐 제체 및 침투수 흐름의 지열학적 고찰)

  • Park, Dong-Soon;Jung, Woo-Sung;Kim, Hyoung-Soo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.75-85
    • /
    • 2006
  • In recent geotechnical engineering, geothermal approach has been on the horizon to deal with geoenvironmental issues, freezing and thawing problems, and seepage phenomenon in dams and embankments. In this study, geothermal characteristic through inner body of dams and its influence on the seepage flow were experimented by lab test and field instrumentation. Also, one of up-to-date temperature monitoring technique, called as multi-channel thermal line sensing, was evaluated its availability. As a result of lab test, it is found that the seepage flow has influence on the geothermal characteristic and a potential of finding phreatic line and seepage fluctuation could be possible by continuous temperature monitoring using thermal line sensing skills. These kine of geothermal information could be available to the modelling of water geo-structure interaction. Out of short-term field tests, clear water table and temperature distribution of a dam were easily found through temperature monitoring in holes located near a reservoir and holes within a depth of constant temperature layer. However, it is also found that the geothermal flow and finding seepage line could not be easily understandable through multi-channel temperature monitoring because of the existence of constant temperature field, thermal conductivity of soils and rocks, and unsaturated characteristics of geo-material. In this case, long-term geothermal monitoring is recommended to find sudden fluctuation of seepage line and amount of leakage.

  • PDF

Field Application of 3D seismic travel-time tomography (3차원 탄성파 지대공 토모그래피 현장 적용)

  • Moon, Yun-Seop;Ha, Hee-Sang;Lim, Harry;Ko, Kwang-Beom
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.233-237
    • /
    • 2006
  • 3D travel time tomography was conducted to characterize the subsuface structure in the valley area. In this study, an area($200m{\times}200m$), where borehole informations were available to aid in the interpretation, was covered with wide source/receiver coverage. In data acquisition, both hole to hole and reverse VSP array was employed. For the inversion, 3D seismic traveltime tomography algorithm based on Fresnel volume was implemented. When compared 3D velocity cube with the geological survey and drilling logs, both results were matched well. From this, we concluded that 3D seismic travel time tomography has enough potential to the field application.

  • PDF

Temperature Variation during Construction in the Concrete Dam Body by Artificial Cooling (강제냉각(强制冷却)에 의한 콘크리트 제체(堤體)의 시공중(施工中) 온도변동(溫度變動))

  • Lee, Bae Ho;Kim, Hong Cheol
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.9 no.3
    • /
    • pp.39-48
    • /
    • 1989
  • The concrete temperature in mass concrete rises rapidly above the placing temperature owing to the heat given off by the hydrating cement. This temperature rise produces tensile stress and cracks which later become the cause of water leakage in concrete structures. It is essential, therefore, to reduce the interior heat of concrete dam given off by hydrating cement by artificial cooling. The present study aiming to study the temperature variations in mass concrete by pipe cooling, compars the actual measurements of Chungju Dam with the temperature calculated by Finite Difference Method(FDM), and it found that the results closely agree with each other. Based on these results, the analyses are performed simulate the interior temperature history of concerte dam made of type II (moderate heat) portland cement under various coditions.

  • PDF

Parametric Study of MD Constitutive Model for Coarse-Grained Soils (조립재료에 대한 MD구성모델의 매개 변수 연구)

  • Choi, Changho
    • Journal of the Korean Geosynthetics Society
    • /
    • v.12 no.1
    • /
    • pp.11-19
    • /
    • 2013
  • Coarse-grained soils are typical engineering materials commonly used in many civil engineering applications such as structural fills, subgrade and drainage fills for dam, railway and bridge. Various researches have been performed with related to constitutive laws for numerical analysis of such structures. This paper presents a parametric study for a constitutive model for coarse grained materials. The model is a kind of the bounding surface models based on critical state theory. A distinct feature of the model is to capture the response of coarse-grained materials with different void ratios and confining pressures using a single set of model parameters. The model behavior is defined with a set of elastic parameters, critical state parameters, and model-specific parameters. The parametric study was performed for the model-specific parameters. The result of parametric study shows that the model is capable to capture stress-dilatancy behavior and kinematic-hardening under non-associative plastic flow.

Temperature Effects in the Resistivity Monitoring at Embankment Dams (저수지 전기비저항 모니터링에서의 온도효과)

  • Kim, Eun-Mi;Cho, In-Ky;Kim, Ki-Seog;Yong, Hwan-Ho
    • Geophysics and Geophysical Exploration
    • /
    • v.21 no.2
    • /
    • pp.82-93
    • /
    • 2018
  • Resistivity monitoring data at embankment dams are affected by the seasonal temperature variation. Especially when the seasonal temperature variation is large like Korea, the temperature effects may not be ignored in the longterm resistivity monitoring. Therefore, temperature effects can make it difficult to accurately interpret the resistivity monitoring data. In this study, through analyzing the time series of ground temperature collected at an embankment dam, ground temperature variations are calculated approximately. Then, based on the calculated temperature profile with depth, the inverted resistivity model of the embankment dam is corrected to remove the temperature effects. From these corrections, it was confirmed that the temperature effects are significant in the upper, superficial part of the dam, but can be ignored at depth. However, temperature correction based only on the temperature distribution in the dam body cannot remove the temperature effect thoroughly. To overcome this problem, the effect of temperature variation in the reservoir water seems to be incorporated together with the air temperature variation.

Estimation of Turbidity Relationship of Reservoir Sediment Using Band-ratio (밴드비를 이용한 저수지 토사의 탁도 관계식 추정)

  • Shin, Hyoung-Sub;Park, Jong-Hwa;Lee, Kyu-Ho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.1063-1068
    • /
    • 2010
  • 최근 들어 지구온난화의 영향 등 기후변화에 따라 호우의 빈도와 강도가 증가하여 홍수피해가 확대되고 토사재해, 댐과 저수지의 퇴사 문제가 심각하게 대두되고 있다. 특히 농업용저수지의 경우 제체가 노후화되고 유입토사에 의한 퇴사는 심각한 수준에 있다. 또한 도심중심의 다양한 공사 등은 토지 이용과 피복을 변화시켜 많은 토사 유출의 원인이 되고 있다. 이렇게 노출된 토사는 탁수발생원이 되고, 토사와 부유물로 형성된 탁수환경은 수중의 태양복사에너지 전달을 방해하여 수중생태계의 먹이사슬과 저서생물의 서식환경에 악영향을 미치고 있다. 특히 농업용 저수지는 반폐쇄성 수역으로써 탁수환경에 노출되기 쉬우며, 수질회복에는 많은 노력과 비용이 소요된다. 또한 탁수환경의 변화는 시 공간적으로 발생하고 지속적으로 일어나기 때문에 탁수환경에 미치는 토사에 대한 연구는 우선적으로 시행되어야 한다. 이러한 토사 정보의 추출 및 분석에 RS기법의 활용은 증대되고 있으나 우리나라에서는 아직 연구가 미진하여, 이에 대한 기초연구가 시급한 실정이다. 본 연구는 2단계로 진행하였다. 먼저 1단계는 탁도계(2100P turbidimeter)를 이용하여 토사농도 변화에 따른 탁도를 측정하여 탁도 관계식을 추정하였다. 2단계는 분광복사계(LI-1800)를 이용하여 토사농도 변화에 따른 분광반사율을 측정하고, 얻어진 결과는 도함수와 적분의 수치해석 방법으로 토사농도를 측정할 수 있는 최적밴드를 구하였다. 다음으로 각 밴드간의 비를 계산하여 탁수환경을 측정할 수 있는 가장 적합한 밴드 조합식을 구하였다. 얻어진 밴드 조합식은 1단계에서 추정한 토사농도에 따른 탁도 관계식과의 상관관계를 분석하여 분광복사계를 이용한 탁도 관계식을 추정하였다. 그 결과, 6개의 탁도 관계식이 추정되었으며 결정계수 $R^2$는 0.67의 높은 상관성을 보였다.

  • PDF

Numerical modeling of impulse wave (수면 충격파의 수치모의)

  • Paik, Joongcheol
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.44-44
    • /
    • 2015
  • 저수지나 하천 사면에서 발생하는 산사태와 토석류는 저수지와 하천 수체에 충격을 가한다. 이로 인해 발생하는 수면 충격파는 전파되어 반대편 제방으로 파의 처오름 또는 댐 제체위로의 물넘이로 큰 피해를 줄 수 있다. 최근 외국에서는 2차원 충격파 생성 및 전파의 기본 과정을 구명하기 위한 실험적 연구가 이뤄지고 있으며, 이들 연구들은 충격파의 발생과 전파, 사면활동 물질과 수체의 상호작용 그리고 자유 수면과 유속분표의 발달에 대한 자세한 관측 자료를 제시하고 있다. 아울러 충격파에 영향을 주는 지배 매개변수를 제시하고 있다. 하지만, 이러한 실험적 연구의 최근 진보에도 불구하고, 이들 지배 매개변수를 고려한 충격파 지배공식들은 대상 지역의 복잡한 바닥 지형이나, 평면적 지형 변화를 단순한 추정치로만 고려하게 된다. 따라서 복잡한 지형조건에서 토석류와 수체의 상호작용과 수면 충격파의 전파를 합리적으로 해석하는 데는 한계가 있다. 이 경우 수치모델링 기법을 대안으로 적용할 수 있으나, 수치모델링은 수면에서 충격파의 전파와 수중에서 토석류의 전파를 동시에 모의해야 하고, 뉴턴 유체와 비뉴턴 유체의 특성을 동시에 고려해야하므로 수치해석 연구자들에게는 하나의 큰 도전사항이다. 이 연구는 경계면 포착기법을 이용한 계산유체동력학 기법을 이용하여 사면활동과 이로 인한 정지 수역에서의 충격파의 발생 및 전파를 재현하기 위한 수치 모델링 기법을 개발하는 것이 목적이다. 사면활동과 수면의 경계면을 포착하고 위치를 정립하기 위해서 VOF (volume of fluid) 경계면 재구축 기법을 이용한다. 지배 방정식은 비압축성(incompressible) 질량 보존방정식과 나비어-스톡스(Navier-Stokes) 방정식이며, 서로 다른 유체의 상(phase)애 대한 체적분할이송방정식을 이용한다. 큰와 모의 계열의 난류 모델링 기법을 적용하여 충격파의 전파와 붕괴에 대한 난류의 영향을 고려하였다. 토석류는 비뉴턴 흐름저항 관계식을 적용하여 그 흐름특성을 재현하였다. 이들 지배방정식은 2차 정확도의 유한체적법(finite volume method)을 이용하여 해석한다. 외국의 연구자들이 관측하여 제시한 길이 11 m 그리고 폭 0.5 m의 수로에서 발생한 충격파를 수치적으로 재현하여 개발된 모형의 실제 문제에 대한 적용성을 보여준다.

  • PDF

Estimation of Dynamic Material Properties for Fill Dam : I. In-situ Shearwave Velocity Profiles (필댐 제체 재료의 동적 물성치 평가 : I. 현장 전단파 속도 주상도)

  • Kim, Jong-Tae;Kim, Dong-Soo;Park, Heon-Joon;Kwon, Hyek-Kee
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.12
    • /
    • pp.69-85
    • /
    • 2009
  • It is very important to measure reliable dynamic properties of each zone in dam for seismic design. However, the Vs values of core and rock-fill zone are seldom determined by field test. Consequently, seismic design in dam is performed using Vs values assumed or empirically determined. So, it is required that reliable Vs has to be evaluated by in-situ test. In this study, surface wave method, which is nondestructive, was applied to dam to evaluate Vs profiles of core and rock-fill zone in dam. In 6 dams, using SASW and HWAW methods, Vs profiles were evaluated reliably. D/B of Vs profiles of each zone with depth and relationship between confining pressure and Vs profiles of rock-fill zone were constructed including existing results of other dams. The evaluated D/B and proposed relationship were compared with the frequently used empirical method by Sawada and Takahashi.