• Title/Summary/Keyword: 댐퍼변위

Search Result 62, Processing Time 0.031 seconds

Displacement Dependency and Capacity Evaluation According to the Cross-Sectional Shape and Aspect Ratio of Steel Rod Dampers (강봉댐퍼의 단면형상과 형상비에 따른 변위의존성 및 성능 평가)

  • Hyun-Ho Lee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.5
    • /
    • pp.89-96
    • /
    • 2023
  • In this study, the displacement dependence, strength, and energy dissipation capacity of the steel rod damper were evaluated. The test variables were cross-sectional shape and aspect ratio. The 6th test specimens were made for performance test. From the test results, it was evaluated that the displacement dependence conditions of design code were satisfied in all specimens. And the strength effect according to the cross-sectional shape was minimal. As a result, the strength and energy dissipation capacity of the aspect ratio of 13.7 were evaluated as excellent.

Behavior of Viscous damper for passive energy dissipation system (제진시스템용 점성댐퍼 이력특성)

  • Choi, Ki-Sun;Cho, Hae-Jin;You, Young-Chan;Kim, Keung-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.133-134
    • /
    • 2010
  • An experiment was carried out to evaluate energy dissipation capacity and velocity dependent characteristics of the viscous damper. From the experiment, it was found that the viscous damper showed velocity dependent characteristics and excellent energy dissipation capacity.

  • PDF

Steel Rod Damper and Rocking Behavior (강봉 댐퍼와 록킹 거동)

  • Lee, Hyun-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.6
    • /
    • pp.1-9
    • /
    • 2020
  • In this study, a seismic reinforcement system was developed considering the rocking behavior of walls. The rocking behavior is to rotate left and right around the vertical axis of the wall, and the development system is a method of dissipating energy by installing a damper to a large displacement part. Developed steel rod damper was used, and steel rod diameter and length(aspect ratio) were selected as variables. As a result of the experiment, it was evaluated to have excellent seismic performance when the damper length was 260mm.

Vibration Analysis of an Amplitude Proportional Friction Damper System (변위비례식 마찰댐퍼 시스템의 진동해석)

  • 박동훈;최명진
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.5
    • /
    • pp.171-179
    • /
    • 2003
  • An Amplitude Proportional Friction Damper (APFD) is considered in order to improve the characteristics of Coulomb friction damper. The frictional force is proportional to the amplitude in APFD system and the system is non-linear as is Coulomb damper system. A free vibration analysis on the 1-DOF system has made to demonstrate the characteristics of the APFD system. The results show that APFD system has similar damping characteristics to the viscous damper. Also, the solution for the response of a base-excited system with APFD is developed through the application of a Fourier series to represent the frictional force of APFD. It is assumed that no stick-slips occur during any portion of the steady-state oscillation.

Hysteretic Behavior of Steel Slit Damper (강재 슬릿댐퍼의 이력특성)

  • Choi, Ki-Sun;Son, Young-Seon;Cho, Hae-Jin;You, Young-Chan;Kim, Keung-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.65-66
    • /
    • 2009
  • An experiment was carried out to evaluate energy dissipation capacity and hysteretic behavior of the steel slit damper. From the experiment, it was found that the steel slit damper showed a stable hysteretic behavior with excellent energy dissipation capacity.

  • PDF

Optimal Design of a Vibration Absorber Against Machine Tool Chatter (공작기계 채터 방지를 위한 진동흡수기의 최적설계)

  • 김광준
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.8 no.2
    • /
    • pp.162-170
    • /
    • 1984
  • 대부분의 동적댐퍼들은 주구조물의 진동진폭을 정해진 주파수 변위내에서 최대로 줄이는 것을 목 표로 한다. 그러나 공작기계의 안정성은 시편과 공구사이의 상대변위와 절삭력에 의해 결정되는 전달함수의 최대크기에 의해서보다는 실수부분의 최소치에 의해 결정된다는 것이 잘 알려져 있 다. 본 논문에서는 이 사실에 착안하여 공작기계에서 발생하는 채터를 흡수하기 위한 최적의 댐 퍼를 설계하는 절차를 제시하고 1 자유도로 대표될 수 있는 구조물의 경우에 대하여 구체적인 방 법을 예시하였다. 종래의 최적 댐퍼의 성질을 구하는 방법에 비해 수학적인 절차가 약간 복잡해 지기는 하나 전산기를 이용하여 큰 어려움이 없이 최적의 설계자료를 얻을 수 있다. 댐퍼 질량이 정해졌을 때 감쇠율과 스프링 계수를 변수로 하는 목표함수가 하나의 식으로 유도될 수 없기 때 문 에 간단한 최적화 방법으로 이변수 황금분할법을 사용하였다. 수치적인 예를 통하여 종래의 다른 방법에 의한 결과와 비교하고 제안된 방법론의 타당성을 입증하였다.

A Study on the Damper Displacements of High Speed Rolling-stock Running on Service Lines (실선로 주행에 따른 고속철도차량 댐퍼 변위에 대한 연구)

  • Hur H.M.;Lee C.W.;You W.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.261-262
    • /
    • 2006
  • This study was intended to research the displacement characteristics of dampers for Korea hish-speed rolling-stock for the purpose of developing the protective and maintenance technology of damper. For this, we measured the displacements of dampers in the actual running conditions of high speed railway vehicles. Displacement data were analyzed depending on the service sections, with which the valuable data necessary for maintenance in the future could be obtained.

  • PDF

Seismic Retrofit of Existing RC Structure Using Hysteretic Dampers (이력댐퍼를 이용한 기존 RC구조물의 내진보강)

  • Choe, Seon-Yeong
    • Computational Structural Engineering
    • /
    • v.26 no.2
    • /
    • pp.37-42
    • /
    • 2013
  • 준공 후 상당한 시간이 지나 내진설계가 되지 않았거나 내진상세가 이루어지지 않은 건물의 부족한 내진성능을 보완하기 위한 방법의 하나로 좌굴이 제한된 가새형 댐퍼를 적용할 수 있다. 이 방법을 적용할 경우, 기존 내진보강법의 불확실성을 줄일 수 있었음에도 불구하고, 댐퍼의 설계과정이 복잡하여 실무에 적용하기 어려웠다. 그러나 본 원고에서는 강성과 강도개념을 적용한 댐퍼의 설계법을 적용함으로써, 실무에서 쉽게 적용할 수 있도록 하였다. 준공된 지 16년이 지난 비틀림 비정형 건물에 대한 내진성능을 평가한 후, 가새형 댐퍼로 보강한 결과는 다음과 같다. (1) 일방향해석결과 나타난 골조별 하중-지붕변위의 관계를 이용하여, 연약골조의 강성을 강한 골조의 강성과 일치시키고, 이 강성비로부터 댐퍼가 부담하는 최적의 내력비율을 정하여 내진보강을 수행한 결과, 가새를 설치한 방향으로는 가새형댐퍼가 비틀림 방지와 연성증대효과를 구조물에 부여하여 성능이 획기적으로 증가하였다. 또한, 그 가새의 직각방향 하중에 대해서도 가새를 설치함으로써 비틀림 강성이 증가하고, 가새와 코어벽체가 인장과 압축으로 횡력에 저항하여 횡저항 성능이 증가하였다. (2) 내진성능이 부족한 비틀림 비정형 건물의 내진성능을 증진시키기 위해 가새형 댐퍼를 적용함에 있어, 댐퍼의 강성을 이용하여 구조체의 비틀림 거동을 최소화하고, 연성을 증진시키는 방법을 체택할 경우, 실무자들이 보다 쉽게 적용할 수 있으면서 그 효과도 상당히 클 것으로 기대된다.

The Effect of Preventing Lateral Deformation of the Clamp Type Steel Damper in Rocking Behavior (록킹 거동을 하는 꺽쇠형 강재 댐퍼의 횡변형 방지 효과)

  • Lee, Hyun-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.5
    • /
    • pp.141-148
    • /
    • 2021
  • In this study, the technology to prevent lateral deformation of steel dampers was reviewed and applied to the clamp type dampers. As for the experimental method, the rocking behavior was applied as in the previous study. The evaluation variables are the existing research results (SV-260) without lateral deformation prevention details and the test results (V-1, V-1R) with lateral deformation prevention details. Where, V-1 is the lateral deformation prevention detail at the lower part of the damper, and V-1R is the lateral deformation prevention detail at the lower part and upper part of the damper. As a result of evaluating the moment, drift ratio, and energy dissipation capacity relative to SV-260 at the time of maximum load, the maximum moments of V-1 and V-1R were increased by 1.22 times and 1.36 times compared to SV-260, and the maximum drift ratio increased by 2.41 times and 2.92 times. In addition, the energy dissipation capacity also increased by 1.39 times and 1.52 times, respectively. Therefore, the application of lateral deformation prevention details to the steel damper was evaluated as appropriate.

Seismic Resistance Response of Railway Station Building Retrofitted by Metallic Dampers (강재댐퍼를 적용한 역사 건물의 내진 응답)

  • Lee, Hyun-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.2
    • /
    • pp.82-88
    • /
    • 2010
  • The purpose of this research is a seismic capacity evaluation and strengthening of existing railway station buildings, which were constructed before the seismic design code activated. The seismic capacity of 2nd story RC station building is evaluated by using nonlinear time-history analysis. Analysis results are checked by story drift ratio and story shear, which are described in design code. As a result, the story shears are exceeding the base shear of the design code, the appropriate seismic strengthening methods are needed. To improve the seismic capacity, metallic dampers are used. Evaluation parameters are metallic damper shape and damper installation methods. Dampers are installed in four places in X and Y directions of station buildings. By reviewing of time-history analysis results, the metallic damper, which is installed inverted K-brace type, shows a better seismic performance than other damper shape and installation methods.