• Title/Summary/Keyword: 대지

Search Result 812, Processing Time 0.037 seconds

A Study on the Application of Soil-Reinforced Retaining Wall for Excavation Slope (절토사면에서 보강토 옹벽의 적용성 연구)

  • Byun, Yoseph;Wrryu, Woongryeal;Lee, Dongho;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.2
    • /
    • pp.53-60
    • /
    • 2010
  • Considering environmental issues and lack of space, it is a necessity to minimize the amount of excavation. Various types of excavation methods are being used in practice. This study proposes a reasonable method for estimating the earth pressure acting on a reinforced wall in front of a excavated slope. The measured data in the field and numerical analyses were used. Results of the study shows that the earth pressure acting on the excavated wall is less than that estimated by Rankine's equations. It was shown that when the excavated slope is used with the reinforced wall, the pressures acting on the reinforced wall can be greatly reduced.

A Study on the Articulation between Architecture and Site of Le Corbusier's Works - Based on the Analysis of Purism Painting - (르 꼬르뷔제 작품에 나타나는 건축과 대지의 분리 관계 연구 - 퓨리즘 회화의 분석을 바탕으로 -)

  • Cho, Joo-Hyun;Shin, Buhm-Shik
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.3
    • /
    • pp.40-49
    • /
    • 2012
  • The purpose of this study is to look into an articulation between architecture and site of Le Corbusier's works. The first of his principals, "piloti" shown in "5 principals in new architecture" represents the articulated relationship between architecture and site. It certainly works as a driving force of new architecture Le Corbusier pursued. The study presumed that this is the constructive application of "Modernity" with new technology and materials during the turn of century. It also seems to be a tool for visual presentation of implied "Will of Form" for his paintings and architecture as well. In this perspective, this study suggests an assumption of a certain connection between the principal of spatial articulation on his purism paintings and the architectural spaces created by piloti. The study finds evidences that supports the above mentioned assumption; first, the inter-relationship between the interval spaces on his paintings and lifted box, second, the movement of space as overlapped spaces, and finally, overlapped volume which is represented by intersection.

  • PDF

Resistivity Analysis of Model Block for Using of Structure Grounding Electrode (구조체접지극 활용을 위한 모형블록의 저항률 분석)

  • Kim, Sung-Sam;Jeong, Man-Gil;Choi, Jong-Kyu;Koh, Hee-Seog
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.2
    • /
    • pp.40-45
    • /
    • 2007
  • This study analyzed the resistivity characteristic of model block to make the good use of structure grounding and substitution grounding electrode base of building. After making the model block of mortar and concrete block, it measured resistivity in hydrous condition and dry condition and compared with the blocks that is mixed earth resistance lowering agent to decrease resistivity. The resistance value of block accepted much influence by block resistivity. When the block resistivity was same or similar value, the value of soil resistivity has occurred as different as the value of grounding resistance.

A Disaster Support System for View Point Research about Japan Earthquake Insurance Problems (재해자 지원으로 본 일본의 지진보험의 문제점에 관한 연구)

  • Kang, Shinwook;Park, Namkwun
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.2
    • /
    • pp.230-237
    • /
    • 2014
  • A victim of natural disaster support systems are self-help, cooperation and taxes and other public charges. This research purpose, a victim support system became the focus of cooperation(Earthquake Insurance, Japan Agricultural Cooperatives and ZENROSAI) that is base on strength of East-Japan Earthquake, is reviewing the supply present condition and limit of provide relief problems. research is using data that is base on many kinds of publications and homepages and hearing by Japan Agricultural Cooperatives and Insurance company.

Earth Resistance Measurement Method by Clamp-one Type Current Comparison (클램프온식 전류비교 접지저항 측정방법)

  • Jeong, M.S.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.353-355
    • /
    • 2007
  • 피접지체의 접지는 전력설비의 절연파괴,낙뢰 등으로 전압이 침입할 경우 접지전극의 접지저항이 높으면 접지전극으로 유입되는 전류와 접지저항의 곱에 해당하는 접지전극의 전위가 상승하게 되므로 설비의 파손 인축의 피해 등이 발생 할 수 있다. 따라서 접지저항은 낮은 값으로 유지하는것이 필요하고 정기적으로 측정하여 관리하도록 규정하고 있다. 대표적인 접지저항측정방법으로는 3전극법(Fall of potential method)과 Hook-on 측정법이 있다. 그러나 3전극법은 측정하고자 하는 접지전극으로부터 일정한 거리에 전류를 흘려주고 이때 대지 전위를 측정 할 수 있는 2개의 보조전극 설치가 필수적이나 접지극과 접지선의 단자와는 설치 위치가 다르므로 접지전극의 설치점을 확인하기 곤란하고 건물내부, 지하철, 터널 등에는 보조전극의 설치가 거의 불가능하므로 처음 설치한 접지극의 접지저항측정관리에 어려움이 크다. 또한 Hook-on 측정법은 다중 접지 계통에 사용하는 방법으로 접지극이 수십 또는 수백개를 병렬로 연결한 경우 측정하고저 하는 접지그의 접지저항값에 비해 나머지 접지전극 전체의 합성저항이 무시할 수 있을 만큼 적은 경우에만 측정할 수 있으므로 건물이나 변전실 등 수개의 접지극이 설치된 경우는 사용할 수 없다. 본 연구는 보조전극을 설치하지 않고 측정하고자하는 접지전극 상호간의 전류분배 비율을 저항의 역수 비율로 하여 각각의 접지 전극의 접지저항값을 운전 중인 상태에서 간단하고 정확하게 측정할 수 있는 새로운 접지저항 측정 방법에 관한 연구이다.

  • PDF

Analysis of Medium Voltage Power-Line Channel Characteristics Considering the Skin Effect (표피효과를 고려한 중전압 전력선 채널특성 분석)

  • 김선효;이원태;이영철
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.5
    • /
    • pp.731-738
    • /
    • 2002
  • In this paper, we analyzed a medium voltage power line characteristics considering the skin effect for high speed data transmission. Medium power-line characteristics impedance was obtained by the S-parameter method which is used in high frequency band. Power line channel characteristics was measured using it designed coupler, it is a wide band coupler between medium powe-line and measurement system. Attenuation characteristics along the frequency was decreased linearly when skin effect was considered but attenuation characteristics along the frequency was decreased linearly when skin effect was not considered. Impedance was showed lower and lower in proportional to frequency, and variation was decreased in proportional to frequency.

Design and Application of a Ground Risk Voltage Measurement System (대지 위험전압 측정기의 설계 및 적용)

  • Jang, Un-Yong;Cha, Hyeon-Kyu;Cha, Sang-Wook;Park, Dae-Won;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.3
    • /
    • pp.250-255
    • /
    • 2011
  • This paper dealt with the design, fabrication and application of a risk voltage measurement system (RVMS) which analyzes the step and touch voltages in electrical grounding systems. The RVMS supply 300 V and 1.4 A in ranges from 40 Hz to 1 kHz as the test power source. A DAQ module having resolution of 400 kS/s and 16 bit is equipped with 7 inputs for measuring voltage and current. Also, a noise elimination algorithm of digital filter was applied to reduce the measurement error caused by external noises as a commercial frequency current. The performance of the RVMS was evaluated by measurement of the step and touch voltage according to the IEEE standard 80 and 81 in a grounding system with a 10 m counterpoise. The result showed that the RVMS analyzes the risk voltage with the error below 5%.

Analysis of Extreme Flood for Nuclear Power Plant Site (원전부지의 방재대책 수립을 위한 극한홍수해석)

  • Keum, Ho Jun;Park, Jun-Hyeong;Heo, Jun Haeng;Han, Kun Yeun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.553-553
    • /
    • 2016
  • 2011년 3월 일본 후쿠시마에서 대지진과 쓰나미로 인하여 대규모의 경제적 피해와 생명에 위협을 준 원전사고가 발생하였다. 이처럼 국가주요시설인 원전부지의 사고위험은 다양한 원인으로 인해 늘 위협받고 있으며, 최근 기후변화로 인하여 단시간의 지역적인 집중호우와 예상치 못한 폭우가 빈번하게 발생하고 있는 상황에서 극한홍수로 인한 사고 또한 중요한 원인으로 인식되고 있다. 하지만 우리나라에서는 원전부지에 대하여 PMP 등의 이상강우 조건 하에서 수공학적 안정도 평가와 국가 주요시설물 부지의 침수해석기법의 개발은 아직까지 전무한 실정이다. 따라서 본 연구에서는 원전부지 내에 영향을 미치는 극한강우를 다양한 기법으로 산정하여 가장 큰 피해를 미치는 극한강우 사상을 도출하였다. 도출한 극한강우를 유역유출분석을 통해 실제 원전부지 내로의 유입 경계조건으로 고려하여 2차원 침수해석을 실시하였다. 2차원 침수해석을 위해 원전부지 내 주요시설물, 도로, 하수관망 및 구조물 등을 반영하여 지형자료를 구축하였으며, 유출분석을 통해 유입되는 극한홍수량 외에 원전부지 내로 내리는 직접 강우도 함께 고려하였다. 그 결과를 통해 원전부지 내 침수심 및 유속 분포 등의 침수정보를 제공할 수 있는 침수위험도를 작성하였다. 본 연구를 통해 원전부지 내의 극한강우 산정 및 그로인한 침수위험도 작성으로 원전부지의 방재대책 수립시 기초자료로써 제공될 수 있을 것으로 판단된다.

  • PDF

Effect Analysis of Rainwater Management Facility for Improving Urban Water Cycle (도시 물순환개선을 위한 빗물관리시설의 효과분석)

  • Park, Sung Chun;Gwak, Pil Jeong;Lim, Ok Geun;Kim, Jong O
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.482-486
    • /
    • 2016
  • 광주광역시 도심유역의 14개 단위유역(영본B02~영본B25)으로 면적 $501.19km^2$ 중 약 42%에 해당하는 $211.86km^2$을 대상유역으로 분산식 빗물관리에 의한 물순환 체계를 구축하였다. 지목별 저감대상 면적은 대지, 창고, 공장용지는 전체면적의 15%, 주유소, 학교, 잡종지, 종교용지, 주차장은 5%, 도로는 10%를 적용하여 저감대상 산출면적은 $9.1km^2$로 설정하였으며, 초기강우 10mm에 대한 초기강우유출량 $90,885m^2$이 발생하며 이는 각 단위유역의 토지이용별로 침투통, 침투측구, 침투화분, 침투도랑, 수목여과박스, 식생수로, 빗물저금통, 투수블럭의 8개 시설에 의해 침투 및 저류하는 것을 제안하였으며, 또한, 본 연구의 대상유역에서 발생하는 비점오염원 발생부하량은 8,439.16kg/일으로 그 중 2.4%에 해당하는 210.186kg/일이 본 연구에서 제안한 빗물 관리시설에 의해서 삭감되는 것으로 분석되었다. 또한, 빗물관리시설의 총 투자비용은 약 322억원이며, 효과 비용은 343억원으로 산정되었다.

  • PDF

A Study on clinical application of the QSCC II (Questionnaire for the Sasang Constitution Classification II) (사상체질분류검대지(四象體質分類檢査紙) (QSCC II)의 임상적(臨床的) 활용(活用)에 관(關)한 연구(硏究))

  • Ju, Jong-Chun;Kim, Joo-Hhan;Kim, Kyung-Yo;Park, Hye-Sun
    • Journal of Sasang Constitutional Medicine
    • /
    • v.14 no.2
    • /
    • pp.35-43
    • /
    • 2002
  • This study was performed to examine a clinical application of the QSCC II (Questionnaire for the Sasang Constitution Classification II) In this study, the subjects were 218 patients whose constitutions were differentiated at the Wonkwang Kwangju Oriental medical hospital. The results are as follows: 1. QSCC II were given to 218 patients after they were examined by the specialists in the Sasang constitutional medicine and received herbal formulas specific to their constitution. The constitutional analysis made by the specialists were then compared to the results of the questionnaire. The result showed only 51% agreement. 2. We made a frequency analysis of 121 questions and found that 85 questions had low statistical significance (P>0.2). 3. As a result, we have found that there is a limitation in differentiating the constitution by the questionnaire. Thus, in order to raise the statistical significance of the constitutional analysis, we hope that more suitable questionnaire will be developed for the future research.

  • PDF