• Title/Summary/Keyword: 대류열전 달계수

Search Result 202, Processing Time 0.022 seconds

A Study on Thermal Shock of Ceramic Monolithic Substrate (세라믹 모노리스 담체의 열충격 특성에 관한 연구)

  • Baek, Seok-Heum;Park, Jae-Sung;Kim, Min-Gun;Cho, Seok-Swoo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.2
    • /
    • pp.129-138
    • /
    • 2010
  • Technical ceramics, due to their unique physical properties, are excellent candidate materials for engineering applications involving extreme thermal and chemical environments. When ceramics are rapidly cooled, they receive thermal shock. The thermal shock parameter is defined as the critical temperature difference. The critical temperature difference for ceramic parts is influenced by its size, the convective heat transfer coefficient, etc. The thermal shock for a component is analyzed by using the transient thermal stress. If the transient thermal stress exceeds the modulus of rupture (MOR), cracking by thermal shock is initiated. The critical temperature difference for water is less than the critical temperature difference for air. The three-way catalyst substrate used in this study has an adequate performance against thermal shock because its radial and axial temperature differences existed below the critical temperature differences.

Performance Analysis of Heat Sink for LED Downlight Using Lumped Parameter Model (집중변수모델을 이용한 LED조명등 방열기구의 성능분석)

  • Kim, Euikwang;Jo, Youngchul;Yi, Seungshin;An, Younghoon
    • Journal of Energy Engineering
    • /
    • v.26 no.2
    • /
    • pp.64-72
    • /
    • 2017
  • The performance analysis of the 70 W class LED lighting system suitable for the Middle East environment was performed using the lumped parameter model. The LED light is composed of a heating substrate, a heat pipe, and a heat sink. We divided the LED lights into four objects and applied energy equilibrium to each of them to establish four lumped nonlinear differential equations. The solution of the simultaneous equations was obtained by the Runge-Kutta method. Convective heat transfer coefficients of the lumped model were obtained by multidimensional CFD analysis. As a result of comparison with experiment, it was found that the heating substrate had an error of $1.5^{\circ}C$ and the upper heat sink had an error of $1.8^{\circ}C$ and the relative error was about 0.6 %. Using this model, temperature distribution analysis was performed for normal operating conditions with an ambient temperature of $55^{\circ}C$, with sunlight only, with abnormal operating conditions with sunlight, and without an upper heat sink.

A Study on the 1-Way FSI Analysis for Shutter of Side Jet Thruster (측추력기 Shutter의 단방향 유체-구조 연성해석에 관한 연구)

  • Ko, Jun Bok;Seo, Min Kyo;Lee, Kyeong Ho;Baek, Ki Bong;Cho, Seung Hwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.12
    • /
    • pp.1359-1365
    • /
    • 2014
  • In this study, 1-way fluid structure interaction analysis(FSI) for the shutter, component of side jet thruster was performed to evaluate the safety. Driving torque to open nozzle, thermal and high pressure load of hot gas was applied to shutter. Thus, the shutter must be designed to endure this load during combustion. We carried out computational fluid dynamics analysis to obtain the pressure, temperature, and heat transfer coefficient of hot gas of side jet thruster. We then used the data as the load condition for a thermal structural analysis using a mapping method. The locations with the maximum stress and temperature distributions were found. We compared the maximum stress with the tensile stress of shutter material according to temperature to evaluate the safety. We also analyzed the radial deformation of the shutter to set the proper interface gap with the side jet thruster parts.

A Study on Development of Porous SiC Ceramic Heat Sink from Solar Wafering Slurry (태양광 웨이퍼링 슬러리 재생 다공성 SiC 세라믹 히트싱크 개발에 관한 연구)

  • An, Il-Yong;Lee, Young-Lim
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.5
    • /
    • pp.2002-2008
    • /
    • 2012
  • In recent years, while the importance of thermal management has been emphasized due to smaller electronic products, various materials have been used as heat sink. In this study, porous ceramic heat sink was developed with SiC, successfully separated from the slurry of SiC occurring in solar energy materials industry and the thermal performance of porous SiC heat sink has been compared with those of aluminum heat sink and pure SiC heat sink through experiment. From the experimental results, it was verified that porous recycled SiC heat sink has better thermal performance than aluminum heat sink since its micropores increase the heat transfer area. In addition, the effect of the micropores on thermal performance has been quantified by increasing convective heat transfer coefficient with numerical analysis.

Thermal Transient Response of a PWR Pressurizer Vessel Wall for the Inadvertent Auxiliary Spray Transient (PWR 가압기에서 오동작 보조살수 과도시 용기벽의 열적 과도응답)

  • Jo, Jong-Chull;Lee, Sang-Kyoon;Shin, Won-Ky;Cho, Jin-Ho
    • Nuclear Engineering and Technology
    • /
    • v.23 no.2
    • /
    • pp.183-199
    • /
    • 1991
  • Transient response of temperature distributions in a Pressurized Water Reactor (PWR) pressurizer vessel wall for the Inadvertent Auxiliary Spray transient has been analyzed with conservatism accounted for the resulting thermal stresses in the regions of the vessel wall which are wetted by the spray water droplets. In order to determine the forced convective heat transfer coefficient at the inner boundary surface of vessel wall where the droplets impinge on and flow down, the transient temperatures of spray droplets when they reach the inner surface of the vessel wall after travelling from the spray nozzle through the pressurizer interior space occupied with the saturated steam-noncondensable hydrogen gas mixture have been predicted. The transient temperature distributions in the vessel wall have been obtained by using the finite element method, and the typical results have been provided. It has been shown that the results of thermal analysis are consistent with representation of the input transient and have plausible physical meaning.

  • PDF

A Study on the Insulation Performance of Composite Multilayer Insulation by Applciation of Heat Storage Tank (축열조용 복합 다층 단열재의 단열 성능 연구)

  • Choi, Gyuhong;Hwang, Seung Sik;Shin, Donghoon;Park, Woo Sung;Park, Dae Woong;Son, Seung Kil;Chung, Tae Yong
    • Journal of Energy Engineering
    • /
    • v.23 no.3
    • /
    • pp.82-87
    • /
    • 2014
  • MLI(Multi-layer Insulation) is widely used to get highly insulating on cryogenic system in order to reduce heat loads. MLI for satellites thermal performance is changed by materials and laminated method. In this study, a composite multilayer insulation by application of heat stroage tank performance were compared with materials and laminated to change the way. Experimental methods of the KS C 9805 was used, the composite multilayer insulation and EPS was compared with the insulation performance. A method for analysis of experimental results is the equivalent thickness about CMI and the insulation performance were used to compare thermal conductance. As a results, the equivalnet thickenss and the thermal conductance of the composite multilayer insulation were smaller than the EPS and the thermal performance are more excellent. In addition, the configuration of the composite multilayer insulation materials and laminated method varies depending on the overall heat transfer coefficient was confirmed.

A study on the thermal performance of all glass evacuated tube collector and refrigerator using solar energy (태양열을 이용한 이중진공관형 집열기와 냉동기의 열성능에 관한 연구)

  • Yoon, Jun-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.4
    • /
    • pp.324-331
    • /
    • 2013
  • All evacuated tube collector is being constantly studied since it can reduce the conductive heat loss in absorber by using vacuum technology and has advantage of heat transport capacity and quick thermal response in comparatively small temperature difference. This study investigated the dynamic thermal performance of the solar collector with the control condition of solar irradiance and fluid temperature by using performance experimental apparatus which is combined with solar collector and refrigerator, examined the thermal characteristics in definite temperature range of fluid in constant temperature tank by simultaneously measuring refrigerating performance. As a result of it, I deducted the related equation of collector efficiency and found that mean collector efficiency has increased through quick heat transfer characteristics according to increase of outdoor temperature and irradiance in case of outlet temperature of constant temperature tank $22^{\circ}C$ when set outlet temperature of solar collector $25^{\circ}C$ with outlet temperature of constant temperature tank $18^{\circ}C$ & $22^{\circ}C$. Also COP of refrigerator was acquired value of 6.2~7.1 at outlet temperature of constant temperature tank $18^{\circ}C$.

A Study on Thermal Performance Comparison between Large and Small Sized Plate Heat Exchanger (판형 열교환기 크기에 따른 전열성능 비교에 관한 연구)

  • Park, Jae-Hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.2
    • /
    • pp.528-534
    • /
    • 2020
  • The early development and use of plate heat exchangers (PHE) were in response to stringent statutory requirements from dairy products in the late 19th century, but PHEs were not exploited commercially until the 1920s. Since then, although the basic concept of PHEs has changed little, its design and construction have progressed significantly to accommodate higher temperatures and pressures, as well as large heat exchanging capacities. The development of current chevron-type corrugated heat plates has been ongoing since the oil shock in the 1970s to improve energy efficiency. The development trend of PHEs is consistent with the development of larger heat plates with better thermal efficiency, lower pressure drop, and good flow distribution. In this study, the thermal performance of small heat plates (PHE-S) and large heat plates (PHE-L) with the same plate depth and corrugation pitch were analyzed experimentally for each channel (H, M, and L type) to suggest development directions of heat plates. The test results showed that for the convectional heat transfer coefficient, the PHE-S was on average, 16.5% higher in the H type, 25% higher in the M type, and 40% higher in the L type than PHE-L. In the case of the pressure drop, the PHE-S was 19% higher in the H type, 46% higher in the M type, and 61% higher in the L type than PHE-L. These results were attributed to the differences in fluid distribution areas between the PHE-S and PHE-L, among other potential causes.

Optimization Techniques for the Inverse Analysis of Service Boundary Conditions in a Porous Catalyst Substrate with Fluid-Structure Interaction Problems (유체 구조 상호작용 문제를 가진 다공성 촉매 담체에서 실동경계조건의 역문제 해석을 위한 최적화 기법)

  • Baek, Seok-Heum;Cho, Seok-Swoo;Kim, Hyun-Su
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.10
    • /
    • pp.1161-1170
    • /
    • 2011
  • This paper presents a solution to the inverse problem for the service boundary conditions of thermal-flow and structure analysis in a catalyst substrate. The exhaust-gas purification efficiency of a catalyst substrate is influenced by the shape parameter, catalyst ingredients and so on and is estimated by the thermal flow uniformity. The formulations of the inverse problem of obtaining the thermal-flow parameters (inlet temperature, velocity, heat of reaction, convective heat-transfer coefficient) and the direct problem of estimating from a given outlet temperature distribution are described. An experiment was designed and the response-surface optimization technique was used to solve the proposed inverse problem. The temperature distribution of the catalyst substrate was obtained by thermal-flow analysis for the predicted thermal-flow parameters. The thermal stress and durability assessments for the catalyst substrate were performed on the basis of this temperature distribution. The efficiency and accuracy of the inverse approach have been demonstrated through the achievement of good agreement between the thermal-flow response surface model and the results of experimental vehicle tests.

Relief of Residual Stress and Estimation of Heat-Treatment Characteristics for Al6061 Alloy by Cryogenic Heat Treatment (극저온 열처리에 의한 Al6061 합금의 잔류응력 제거 및 열처리 특성 평가)

  • Ko, Dae-Hoon;Park, Ki-Jung;Cho, Young-Rae;Lim, Hak-Jin;Lee, Jung-Min;Kim, Min-Byung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.10
    • /
    • pp.1145-1153
    • /
    • 2011
  • The purpose of this study is to relieve the residual stress of Al6061 using cryogenic heat treatment. Experimental T6 and cryogenic heat treatments were carried out to define the convective heat-transfer coefficient, which was then applied in the finite-element method (FEM) to predict the residual stress. The predicted residual stress was compared with the residual stress measured by X-ray diffraction (XRD), and the results were in good agreement. The mechanical properties were estimated by measuring the electrical conductivity and hardness. In addition, the size and formation of the precipitations were observed by TEM and XRD analysis for both T6 and cryogenic heat treatments. The effects of the cryogenic heat treatment on the residual stress, mechanical properties, and precipitation of Al6061 alloys were thus confirmed.