• Title/Summary/Keyword: 단층 영상

Search Result 1,413, Processing Time 0.032 seconds

A Study on the Improvement of Resolution of Optical Coherence Tomography System Using Femto-Second Laser (펨토초 레이저를 이용한 OCT 시스템의 분해능 향상에 관한 연구)

  • Yang, Sung-Kuk;Park, Yang-Ha;Chang, Won-Suk;Oh, Sang-Ki;Kim, Hyun-Duk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.6
    • /
    • pp.31-36
    • /
    • 2004
  • Optical coherence tomography system has been extensively studied because it has some advantages such as imaging of high resolution, low cost, and compact size configuration. In order to obtain high resolution of OCT system we configured OCT system using a femto-second laser. We measure the pulse width using autocorrelator function because a femto-second laser is ultra short pulse. And we measured the practical resolution using theoretical equation and the measurement of reference sample. It is confirmed that the proposed OCT system has 1.5 times higher resolution and un distinctive cross-sectional image than OCT system with SLD as a light source.

Development of Convolutional Network-based Denoising Technique using Deep Reinforcement Learning in Computed Tomography (심층강화학습을 이용한 Convolutional Network 기반 전산화단층영상 잡음 저감 기술 개발)

  • Cho, Jenonghyo;Yim, Dobin;Nam, Kibok;Lee, Dahye;Lee, Seungwan
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.991-1001
    • /
    • 2020
  • Supervised deep learning technologies for improving the image quality of computed tomography (CT) need a lot of training data. When input images have different characteristics with training images, the technologies cause structural distortion in output images. In this study, an imaging model based on the deep reinforcement learning (DRL) was developed for overcoming the drawbacks of the supervised deep learning technologies and reducing noise in CT images. The DRL model was consisted of shared, value and policy networks, and the networks included convolutional layers, rectified linear unit (ReLU), dilation factors and gate rotation unit (GRU) in order to extract noise features from CT images and improve the performance of the DRL model. Also, the quality of the CT images obtained by using the DRL model was compared to that obtained by using the supervised deep learning model. The results showed that the image accuracy for the DRL model was higher than that for the supervised deep learning model, and the image noise for the DRL model was smaller than that for the supervised deep learning model. Also, the DRL model reduced the noise of the CT images, which had different characteristics with training images. Therefore, the DRL model is able to reduce image noise as well as maintain the structural information of CT images.

A Study on the Parallel Processing Architecture for the Real Time Image Reconstruction of X-ray CT (X-ray CT의 실시간 영상재구성을 위한 병렬처리 구조에 관한 연구)

  • Jin, Seung-Oh;Heo, Chang-Won;Huh, Young
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3153-3155
    • /
    • 1999
  • 최근 수년간 의료영상분야는 국내외적으로 급격한 발전을 거듭하고 있다. 특히 자기공명영상장치 (Magnetic Resonance Imaging), X-ray CT(Computed Tomography)와 단층촬영장치는 인체내부를 비침습적(non-invasive)으로 영상화함으로써 해부학적인 질병진단에 많은 장점을 가지고 있다. 이와같은 단층영상 재구성에는 역매트릭스법(matrix inversion). 반복재구성법(interative method), 역투영 법(back-projection), 2차원 Fourier 변환법(2D FFT), 중첩재구성법(Filtered back-projection) 등의 다양한 알고리즘을 사용하고 있다. 본 연구에서는 X-ray CT에서의 단층영상재구성 기법 중 널리 사용되고 있는 Filtered Back Projection 기법의 연산순서도와 연산량을 분석하고 이를 시뮬레이션을 통하여 확인하고 실시간 영상재구성을 위하여 범용 Digital Signal Processor의 병렬처리시스템 구성에 기반된 최적 Architecture를 선정하고자 한다.

  • PDF

Beyond Coronary CT Angiography: CT Fractional Flow Reserve and Perfusion (전산화단층촬영 관상동맥조영술: 분획혈류예비력과 심근관류 영상)

  • Moon Young Kim;Dong Hyun Yang;Ki Seok Choo;Whal Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.1
    • /
    • pp.3-27
    • /
    • 2022
  • Cardiac CT has been proven to provide diagnostic and prognostic evaluation of coronary artery disease for cardiovascular risk stratification and treatment decision-making based on rapid technological development and various research evidence. Coronary CT angiography has emerged as a gateway test for coronary artery disease that can reduce invasive angiography due to its high negative predictive value, but the diagnostic specificity is relatively low. However, coronary CT angiography is likely to overcome its limitations through functional evaluation to identify the hemodynamic significance of coronary artery disease by analyzing myocardial perfusion and fractional flow reserve through cardiac CT. Recently, studies have been actively conducted to incorporate artificial intelligence to make this more objective and reproducible. In this review, functional imaging techniques of cardiac computerized tomography are explored.

Neuroimaging of Traumatic Brain Injury (외상성 뇌손상의 영상진단)

  • Choi, Woo Suk
    • Korean Journal of Biological Psychiatry
    • /
    • v.2 no.2
    • /
    • pp.169-176
    • /
    • 1995
  • 두부 외상은 많은 발생율과 사망율을 차지하고 있으며, 건강한 생활을 위해 큰 관심을 갖게 되었다. 신경방사선영상은 외상성 뇌손상 환자들의 진단과 치료에 필수적인 방법이다. 뇌손상의 기본 기전, 병리, 그리고 영상 소견을 이해 하는 것은 매우 중요하다. 1970년대에 Glasgow coma scale의 형상과 전산화단층촬영(CT)의 발달은 임상의사들이 두부외상에 대한 평가와 환자들의 경과를 예상하는데 극적인 변화를 주었다. 최근 자기공명영상(MRI)의 발달로 외상성 뇌손상의 형태를 더욱 이해 하게 되었고, 두부 외상의 발견율이 높아지게 되었다.

  • PDF

Basaloid Squamous Cell Carcinoma of the Lung: Two Case Reports with CT Imaging Findings (폐의 기저세포양 편평세포암: 두 개의 증례 보고와 전산화단층촬영 영상소견)

  • Joo Hee Kim;Hyun Jung Yoon;Eunju Lee;Eun Ju Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.3
    • /
    • pp.746-752
    • /
    • 2020
  • Basaloid squamous cell carcinoma of the lung is now considered a subtype of squamous cell carcinoma as per the 2015 WHO classification and remains a relatively unknown type of lung cancer due to its rarity. Here we report two cases of basaloid squamous cell carcinoma of the lung and their CT findings to clarify some of the radiologic features of this type of cancer. Two patients aged 85 and 68 years with lung basaloid squamous cell carcinoma visited our institution and underwent surgical resection. On CT, the lesions were 3.1 and 2.8 cm in size, respectively, well-defined, round in shape with lobulated margins and prominent intratumoral necrosis. The latter case was followed after operation for 20 months, and there was no recurrence of the disease on CT. Although very rare, basaloid squamous cell carcinoma should be considered a subtype of lung cancer in tumors sharing these CT findings.

Preliminary Experiment for High-resolution Measurement of Tissue Mechanical Properties Using Dynamic Optical Coherence Elastography (동적 광단층 탄성영상법을 이용한 조직의 고해상도 기계적 성질 측정을 위한 예비 실험)

  • Kwon, Daa Young;Ahn, Yeh-Chan
    • Korean Journal of Optics and Photonics
    • /
    • v.29 no.3
    • /
    • pp.99-103
    • /
    • 2018
  • Optical coherence elastography (OCE) is based on optical coherence tomography (OCT), which is a noninvasive, high-resolution, cross-sectional imaging technique. In this paper, we have developed dynamic optical coherence elastography to measure elasticity, a mechanical property of tissue, by phase difference. A piezoelectric actuator was used for sinusoidal mechanical loading of samples. Before applying this method to biomaterial, we assessed the feasibility of OCE with samples of sponge, eraser, and sharp lead. Cross-sectional and phase-difference images of the sample were obtained under sinusoidal loading. The strain rate was calculated from the phase-difference information. To obtain the envelope of the phase-difference oscillations along the horizontal direction, Hilbert transformation was performed at each depth. The elevation of the envelope was represented by color mapping, and we could measure the relative elasticity within the sample by comparing the elevations. Finally, there was an advantage when we calculated the shear rate using self-interference in the sample arm, instead of the interference between sample and reference arms.

Optimizing Imaging Conditions in Digital Tomosynthesis for Image-Guided Radiation Therapy (영상유도 방사선 치료를 위한 디지털 단층영상합성법의 촬영조건 최적화에 관한 연구)

  • Youn, Han-Bean;Kim, Jin-Sung;Cho, Min-Kook;Jang, Sun-Young;Song, William Y.;Kim, Ho-Kyung
    • Progress in Medical Physics
    • /
    • v.21 no.3
    • /
    • pp.281-290
    • /
    • 2010
  • Cone-beam digital tomosynthesis (CBDT) has greatly been paid attention in the image-guided radiation therapy because of its attractive advantages such as low patient dose and less motion artifact. Image quality of tomograms is, however, dependent on the imaging conditions such as the scan angle (${\beta}_{scan}$) and the number of projection views. In this paper, we describe the principle of CBDT based on filtered-backprojection technique and investigate the optimization of imaging conditions. As a system performance, we have defined the figure-of-merit with a combination of signal difference-to-noise ratio, artifact spread function and floating-point operations which determine the computational load of image reconstruction procedures. From the measurements of disc phantom, which mimics an impulse signal and thus their analyses, it is concluded that the image quality of tomograms obtained from CBDT is improved as the scan angle is wider than 60 degrees with a larger step scan angle (${\Delta}{\beta}$). As a rule of thumb, the system performance is dependent on $\sqrt{{\Delta}{\beta}}{\times}{\beta}^{2.5}_{scan}$. If the exact weighting factors could be assigned to each image-quality metric, we would find the better quantitative imaging conditions.

Computational Modeling and Analysis of Ablative Composites Using Micro-tomographic Images (미세 단층 영상을 이용한 삭마 복합재료의 전산 모델링 및 해석)

  • Cheon, Jae Hee;Roh, Kyung Uk;Shin, Eui Sup
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.47 no.9
    • /
    • pp.642-648
    • /
    • 2019
  • In this study, Image-based computational analysis using the developed models was performed to predict the degradation of effective properties by ablation. The ablation tests of carbon/phenolic composites were performed using a 0.4 MW arc-heated wind tunnel. The carbon/phenolic composite samples were scanned using the micro-computed tomography (Micro-CT) to analyze the ablation characteristics according to a duration time of the ablation test. By calibrating the scanned images, computational models were developed that reflect the actual microstructure of the ablation composites. Also, nine computational models that reflect the actual pore shape were developed using the created cross-sectional images. Image-based computational analysis using the developed models was performed to predict the degradation of effective properties by ablation and the decrease of effective properties was confirmed with increase of porosity.

3-D OCT Image Reconstruction for Precision Analysis of Rat Eye and Human Molar (쥐 눈과 인간 치아의 정밀한 단층정보 분석을 위한 OCT 3-D 영상 재구성)

  • Jeon, Ji-Hye;Na, Ji-Hoon;Yang, Yoon-Gi;Lee, Byeong-Ha;Lee, Chang-Su
    • The KIPS Transactions:PartB
    • /
    • v.14B no.6
    • /
    • pp.423-430
    • /
    • 2007
  • Optical coherence tomography(OCT) is a high resolution imaging system which can image the cross section of microscopic organs in a living tissue with about $1{\mu}m$ resolution. In this paper, we implement OCT system and acquire 2-D images of rat eye and human molar samples especially in the field of opthalmology and dentistry. In terms of 2-D images, we reconstruct 3-D OCT images which give us another inner structural information of target objects. OPEN-GL reduces the 3-D processing time 10 times less than MATLAB.