• Title/Summary/Keyword: 단일구조 지르코니아

Search Result 46, Processing Time 0.026 seconds

Full mouth rehabilitation in a patient with partial mandibulectomy using CAD/CAM zirconia framework and monolithic zirconia (하악골 부분절제술 시행한 환자에서 CAD/CAM Zirconia Framework와 Monolithic Zirconia를 이용한 전악 수복 증례)

  • Ma, Bo-Young;Park, Hongju;Im, Yeong-Gwan;Park, Chan;Shin, Jin-Ho;Lim, Hyun-Pil
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.3
    • /
    • pp.279-285
    • /
    • 2017
  • Defects due to mandibulectomy often cause hard and soft tissue loss and result in esthetic problems and functional disorders such as mastication, swallowing, and pronunciation. After the mandibular reconstruction, several complications including loss of alveolar bone can cause limitations in maintenance or supporting of removable prosthesis. For these patients, implant-supported fixed restorations have been an appropriate prosthetic restorative method. In this case report, we report the patient who underwent mandibulectomy and mandibular reconstruction owing to oral cancer, and then restored the current dentition functionally and aesthetically by applying zirconia frameworks and monolithic zirconia crowns by computer-aided design and computer-aided manufacturing.

Fracture Strength Analysis of Monolithic Zirconia Ceramic by Abutment Shape (지르코니아 단일구조 전부도재관의 지대치 형태에 따른 파절 강도)

  • Kim, Won-Young;Hong, Min-Ho
    • Journal of Technologic Dentistry
    • /
    • v.36 no.4
    • /
    • pp.231-237
    • /
    • 2014
  • Purpose: This study was performed fracture strength test by conducted change of abutment and coping shape for suggesting monolithic all ceramic crown which has thin thickness and superior strength of the occlusal surface. Methods: The specimens on the four kinds abutment was made according to thickness of occlusal surface and angle of axis surface. And All ceramic coping specimens of 6 different kinds was made by the CAD/CAM Method. Compression strength test using the UTM and the verification of compression-stress situation using the 3D finite element method were conducted under optimum conditions. Results: 516C specimen was showed the strongest compression-fracture strength, followed by 516FR, 516F45, specimens. Did not show significant differences between 516FR and 516F45. 516C of the universal testing machine the specimen's surface that are within the vertical load is small, finite element method of a uniformly distributed load, so the value received suggests otherwise. Conclusion: In conclusion, abutments of monolithic ziconia ceramic when having a same thickness of the occlusal, as the angle of occlusal edge is small, the stress is well dispersed and it can endure well in the fracture.

FRACTURE STRENGTH OF ZIRCONIA MONOLITHIC CROWNS (지르코니아 단일구조 전부도재관의 파절강도)

  • Jeong Hee-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.2
    • /
    • pp.157-164
    • /
    • 2006
  • Purpose: The purpose of this study was to compare the fracture strength of the zirconia monolithic all-ceramic crowns according to the thickness(0.5 mm, 0.8 mm, 1.1 mm) and IPS Empress II ceramic crown of 1.5 mm thickness. Material and method: Eight crowns for each of 3 zirconia crown groups were fabricated using CAD/CAM system(Kavo, Germany) and eight Empress II crowns were made from silicone mold and wax pattern. Each crown group was finished in accordance with the specific manufacturer s instruction. All crowns were luted to the metal dies using resin cement and mounted on the testing jig in a universal testing machine. The load was directed at the center of crown with perpendicular to the long axis of each specimen until catastrophic failure occurred. Analysis of variance and Tukey multiple comparison test(p<.05) were applied to the data. Results and Conclusion: 1. The fracture strength of the zirconia monolithic all-ceramic crown was higher thickness increased(p<.05). 2 The fracture strength of 1.1 mm thickness zirconia monolithic all-ceramic crown was higher than the fracture strength of 1.5 mm thickness IPS Empress II crown(p<.05). 3. The fracture strength of 0.5 mm thickness zirconia monolithic all-ceramic crown exceeded maximum occlusal forces.

Full mouth rehabilitation of a severely worn dentition using intraoral scanner and the CAD/CAM double scanning technique (중증도의 치아 마모 환자를 구내 스캐너와 이중스캔을 이용해 수복한 완전구강회복 증례)

  • Yoon, Se-Na;Han, Jung-Suk;Yeo, In-Sung;Yoon, Hyung-In
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.1
    • /
    • pp.67-76
    • /
    • 2020
  • With the evolution of the computer-aided design/computer-aided manufacturing (CAD/CAM) technology, the intraoral scanners are playing an increasingly important role, as they are the first step towards a completely digital workflow. The CAD/CAM double scanning technique has been used to transfer the information from provisional restorations to definitive restorations. In this case, a 67-year-old male with esthetically compromised anterior teeth, generalized severe attrition of teeth, and reduced vertical dimension was treated with full mouth rehabilitation including a re-establishment of the lost vertical dimension of occlusion assisted by the crown lengthening procedure. The provisional restorations were fabricated using an intraoral scanner and the CAD/CAM double scanning technique. After the period of adaption, the definitive monolithic zirconia restorations were delivered. The CAD/CAM double scanning technique successfully transferred the occlusal and morphological characteristics, obtained from the provisional restorations, to the definitive restorations.

A Making of Aesthetic Dental restorations with Nano Hybrid Ceramic material by CAD/CAM System (치과 CAD/CAM용 Nano Hybrid Ceranic 소재를 이용한 심미 치과보철물의 제작)

  • Choi, Beom-jin
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.25 no.2
    • /
    • pp.98-108
    • /
    • 2016
  • In recent days, perhaps the biggest driver in new material development is the desire to improve restorations esthetics compared to the traditional metal substructure based ceramics or all-ceramic restorations. Each material type performs differently regarding strength, toughness, effectiveness of machining and the final preparation of the material prior to placement. For example, glass ceramics are typically weaker materials which limits its use to single-unit restorations. On the other hand, zirconia has a high fracture toughness which enables multi-unit restorations. This material requires a long time sintering procedure which excludes its use for fast chair side production. Hybrid ceramic material developed for CAD/CAM system is contained improved nano ceramic elements. This new material, called a Resin Nano Hybrid Ceramic is unique in durability of function and aesthetic base compositions. The new nano-hybrid ceramic material is not a composite resin. It is also not a pure ceramic. The material is a mixture of both and consists of nano-ceramic fillers. Like a composite, the material is not brittle and is fracture resistant. Like a glass ceramic, the material has excellent polish retention for lasting esthetics. The material is easily machined by chair side or in a dental lab side, could be an useful restorative option.

Full mouth rehabilitation of the patient with severe tooth loss and tooth wear with vertical dimension gaining: A case report (구치부 지지의 상실과 마모로 인해 교합이 붕괴된 환자에서 수직고경 회복을 동반한 구강회복 증례)

  • Jo, Yu Jin;Jung, Sua;Yang, Hong-So;Park, Sang-Won;Lim, Hyun-Pil;Yun, Kwi-Dug;Park, Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.4
    • /
    • pp.302-307
    • /
    • 2018
  • Multiple tooth loss and excessive occlusal wear can result in damage to occlusal disharmony, functional disorders and esthetic problems, requiring comprehensive prosthetic treatments. Changing vertical dimension harmonized with surrounding muscle tissue is important. In this case, the patient with loss of vertical dimension caused by severe tooth loss and tooth wear was treated with the analysis of vertical dimension, such as diagnostic model, radiography and various clinical exams. the patient was satisfied with favorable functions and esthetics for 1 years of follow-up.

FRACTURE STRENGTH OF ZIRCONIA MONOLITHIC CROWNS AND METAL-CERAMIC CROWNS AFTER CYCLIC LOADING AND THERMOCYCLING (지르코니아 단일구조 전부도재관과 금속도재관의 파절강도 비교)

  • Lee, Sang-Min;Jeong, Hee-Chan;Jeon, Young-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.1
    • /
    • pp.12-20
    • /
    • 2007
  • Purpose: The purpose of this study was to compare the fracture strength of the zirconia monolithic all-ceramic crowns according to the thickness (0.5mm, 0.8mm, 1.1mm) and metal-ceramic crowns (1.0mm, 1.5mm) Material and method: Twelve crowns for each of 3 zirconia crown groups were fabricated using CAD/CAM system (Kavo, Germany) and twelve crowns for each of 2 metal-ceramic crown groups were made by the conventional method. All crowns were luted to the metal dies using resin cement. Half of the specimens were exposed to thermocycling ($5-55^{\circ}C$, 1 Hz) and cyclic loading (300,000 cycles, 50N). Subsequently, all crowns were mounted on the testing jig in a universal testing machine. The load was directed at the center of crown with perpendicular to the long axis of each specimen until catastrophic failure occurred. Analysis of variance and Tukey multiple comparison test (P<.05) were used for statistical analysis of all groups, and paired t-test (P<.05) was followed for statistical comparison between each groups' fracture load before and after cyclic loading. Results: 1. The fracture strength of the zirconia monolithic crowns and the metal-ceramic crown increased as thickness increased (P<.05). 2. The cyclic loading and thermocycling significantly decreased the fracture strength of the zirconia monolithic crowns (P<.05). 3. The standard deviation of fracture strength of the zirconia monolithic crowns was very low. Conclusion: The fracture strength of the zirconia monolithic crowns for the posterior area tends to be higher with thickness increased and 0.8mm or over in thickness is recommended to have similar or over the fracture strength of metal-ceramic crowns.

Full-mouth rehabilitation of skeletal anterior open bite with severely decayed dentition: A case report (심한 우식을 동반한 골격성 전치부 개방 교합 환자의 전악 수복 증례)

  • Kim, Seong-A;Noh, Kwantae;Pae, Ahran;Woo, Yi-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.1
    • /
    • pp.79-87
    • /
    • 2017
  • The open bite malocclusion is a common clinical entity and has multifactorial causes. Development of effective treatment plan and management is dependent on proper diagnosis. The skeletal open bite patient requires a coordinated orthodontic and orthognathic surgical approach to achieve stable occlusion, acceptable esthetics, and improved function. But in case of open bite with severely decayed dentition, restoration in the entire dentition is necessary. Using the facial analysis and diagnostic wax-up, the most effective treatment was prosthetic rehabilitation. The provisional restorations were fabricated to satisfy esthetic and functional requirements, which result in the uniformly distributed occlusal force, anterior and canine guidance. The inter-arch relationship, labio-dental harmony, and the soft tissue aspect, which is important to estimate the longevity were evaluated. Definitive restorations of monolithic zirconia were made by replicating provisional restorations by using the latest CAD/CAM technology. They were delivered to the patient and clinical follow-up observation was satisfactory.

Effect of surface treatments on the shear bond strength of full-contour zirconia layered with porcelain (단일구조 지르코니아(zirconia) 전부도재관의 표면처리에 따른 전장도재와의 전단결합강도)

  • Choi, Byung-Hwan;Kim, Im-Sun
    • Journal of Technologic Dentistry
    • /
    • v.35 no.2
    • /
    • pp.121-126
    • /
    • 2013
  • Purpose: The aim of this research was to investigate difference in shear bond strengths of full-contour zirconia layered with porcelain. Methods: Disk-shaped (diameter: 12.0 mm; height: 3.0 mm) zirconia were randomly divided into six groups according to the surface conditioning method to be applied (N=90, n=15 per group): group 1-contol group(ZC); group 2-airborne particle abrasion with $50-{\mu}m\;Al_2O_3(5A)$; group $3-50-{\mu}m\;Al_2O_3$ + liner(5AL), group $4-110-{\mu}m\;Al_2O_3(1A)$; group $5-110-{\mu}m\;Al_2O_3$ + liner(1AL); group 6-liner(LC). On each block, zirconia porcelain was build up according to manufacturer's instructions. All samples were fixed with measuring jigs and shear bond strength were measured with Universal testing machine. Collected data were analyzed using SPSS(Statistical Package for Social Sciences) Win 12.0 statistics program. Results: LC showed the highest value($29.92{\pm}2.55$ MPa) and ZC showed the lowest value($13.22{\pm}1.37$ MPa). Zirconia liner and Alumina oxide groups was significantly higher shear bond strength than control(p<0.05). 5A (without liner $22.18{\pm}2.37$, with liner $22.84{\pm}1.74$ MPa) was higher shear bond strength than $110{\mu}m$ (without liner $20.18{\pm}2.38$, with $20.71{\pm}2.67$). Conclusion: Surface treatments may have advantage in bond strength improvement for full-contour zirconia layered with porcelain.

Complete mouth rehabilitation with fixed implant-supported prosthesis using temporary denture and dental CAD-CAM (완전 무치악 환자에서 임시 의치와 치과용 CAD-CAM을 활용한 전악 고정성 임플란트 회복 증례)

  • Jeon, Sol;Yoon, Hyung-In;Lee, Jae-Hyun;Yeo, In-Sung Luke;Han, Jung-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.1
    • /
    • pp.100-109
    • /
    • 2022
  • Installation of dental implants at optimal angles and positions is critical in long-term stable implant-supported restorations. Surgery and prosthodontic procedures should be performed accurately as the treatment is planned. In this clinical case, Computer aided design and manufacturing technology was used not only to establish a precise surgical plan, but also to fabricate both provisional and definitive fixed prostheses. A surgical guide was designed to install the implants at proper positions for the definitive prostheses. The patient's esthetic information, which was necessary for the new provisional and definitive fixed prostheses, was obtained from the existing temporary dentures. Finally, the complete mouth fixed implant-supported rehabilitation using monolithic zirconia provided the patient with functionally and esthetically satisfactory prostheses.