FRACTURE STRENGTH OF ZIRCONIA MONOLITHIC CROWNS AND METAL-CERAMIC CROWNS AFTER CYCLIC LOADING AND THERMOCYCLING

지르코니아 단일구조 전부도재관과 금속도재관의 파절강도 비교

  • Lee, Sang-Min (Department of Prosthodontics, College of Dentistry, Pusan National University) ;
  • Jeong, Hee-Chan (Department of Prosthodontics, College of Dentistry, Pusan National University) ;
  • Jeon, Young-Chan (Department of Prosthodontics, College of Dentistry, Pusan National University)
  • 이상민 (부산대학교 치과대학 보철학교실) ;
  • 정희찬 (부산대학교 치과대학 보철학교실) ;
  • 전영찬 (부산대학교 치과대학 보철학교실)
  • Published : 2007.02.28

Abstract

Purpose: The purpose of this study was to compare the fracture strength of the zirconia monolithic all-ceramic crowns according to the thickness (0.5mm, 0.8mm, 1.1mm) and metal-ceramic crowns (1.0mm, 1.5mm) Material and method: Twelve crowns for each of 3 zirconia crown groups were fabricated using CAD/CAM system (Kavo, Germany) and twelve crowns for each of 2 metal-ceramic crown groups were made by the conventional method. All crowns were luted to the metal dies using resin cement. Half of the specimens were exposed to thermocycling ($5-55^{\circ}C$, 1 Hz) and cyclic loading (300,000 cycles, 50N). Subsequently, all crowns were mounted on the testing jig in a universal testing machine. The load was directed at the center of crown with perpendicular to the long axis of each specimen until catastrophic failure occurred. Analysis of variance and Tukey multiple comparison test (P<.05) were used for statistical analysis of all groups, and paired t-test (P<.05) was followed for statistical comparison between each groups' fracture load before and after cyclic loading. Results: 1. The fracture strength of the zirconia monolithic crowns and the metal-ceramic crown increased as thickness increased (P<.05). 2. The cyclic loading and thermocycling significantly decreased the fracture strength of the zirconia monolithic crowns (P<.05). 3. The standard deviation of fracture strength of the zirconia monolithic crowns was very low. Conclusion: The fracture strength of the zirconia monolithic crowns for the posterior area tends to be higher with thickness increased and 0.8mm or over in thickness is recommended to have similar or over the fracture strength of metal-ceramic crowns.

Keywords

References

  1. Coornaert J, Adriaens P, De Boever J. Long-term clinical study of porcelainfused- to-gold restorations. J Prosthet Dent 1984;51:338-42 https://doi.org/10.1016/0022-3913(84)90217-8
  2. Jeong HC. Fracture strength of zirconia monolithic crowns. J Korean Acad Prosthodont 2006;44:157-164
  3. Ozcan M. Fracture reasons in ceramicfused- to-metal restorations. J Oral Rehabil 2003;30:265-9 https://doi.org/10.1046/j.1365-2842.2003.01038.x
  4. McLean JW. The future for dental porcelain. In: Mclean JW, editor. Dental ceramics: dental ceramics-proceedings of the first international symposium on ceramics. Chicago: Quintessence; 1983. p. 13-40
  5. Scotti R. A clinical evauation of In-Ceram crowns. Int J Prosthodont 1995;8:320-3
  6. Lehner C, Studer S, Scharer P. Seven-year results of leucite reinforced glass ceramic crowns [abstract 1368]. J Dent Res 1998; 77:802
  7. Oden A, Andersson M, Krystek-Ondracek I, Magnusson D. Five-year clinical evaluation of Procera Allceram crowns. J Prosthet Dent 1998;80:450-6 https://doi.org/10.1016/S0022-3913(98)70010-1
  8. Sailer I, Feher A, Filser F, Luthy H, Gauckler LJ, Scharer P, Franz Hammerle CH. Prospective clinical study of zirconia posterior fixed partial dentures: 3-year follow-up. Quintessence Int 2006;37:685- 93
  9. Strub JR, Stiffler S, Scharer P. Causes of failure following oral rehabilitation: biological versus technical factors. Quintessence Int 1988;19:215-22
  10. Karlsson S. Clinical evaluation of fixed bridges 10 years following insertion. J Oral Rehabil 1986;13:423-32 https://doi.org/10.1111/j.1365-2842.1986.tb01304.x
  11. Palmqvist S, Swartz B. Artificial crowns and fixed partial dentures 18 years after placement. Int J Prosthodont 1993;6:279- 85
  12. Hankinson JA, Cappetta EG. Five years clinical experience with a leucite-reinforced porcelain crown system. Int J Periodontics Restorative Dent 1994;14: 138-53
  13. Kelsey WP, Cavel T, Blankenau RJ, Barkmeier WW. Wilwerding TM, Latta MA. 4 year clinical study of castable ceramic crowns. Am J Dent 1995;8:259-62
  14. Probster L. Compressive strength of two modern all-ceramic crowns. Int J Prosthodont 1992;5:409-14
  15. Brukl CE, Ocampo RR. Compressive strengths of a new foil and porcelainfused- to-metal crowns. J Prosthet Dent 1987;57:404-10 https://doi.org/10.1016/0022-3913(87)90003-5
  16. Kim SH, Lee JH, Lim YL, Dong JK. Fracture strength of the IPS Empress crown: The effect of occlusal depth and axial inclination on lower first molar. J Korean Acad Prosthodont 2003;41:48- 60
  17. Komine F, Tomic M, Gerds T, Strub JR. Influence of different adhesive resin cements on the fracture strength of aluminum oxide ceramic posterior crowns. J Prosthet Dent 2004;92:359-64 https://doi.org/10.1016/j.prosdent.2004.07.018
  18. Vult von Steyern P, Ebbesson S, Holgren J, Haag P, Nilner K. Fracture strength of two oxide ceramic crown systems after cyclic preloading and thermocycling. J Oral Rehabil 2006;33:682-9 https://doi.org/10.1111/j.1365-2842.2005.01604.x
  19. Sundh A, Sjogren G. A comparison of fracture strength of yttrim-oxide-partially- stabilized zirconia ceramic crowns with varying core thickness, shapes and veneer ceramics. J Oral Rehabil 2004;31:682-8 https://doi.org/10.1111/j.1365-2842.2004.01284.x
  20. Yoshinari M, Derand T. Fracture strength of all-ceramic crowns. Int J Prosthodont 1994;7:329-38
  21. Waltimo A, Kononen M. Maximal bite force and its association with signs and symptoms of craniomandibular disorders in young Finnish non-patients. Acta Odontol Scand 1995;53:254-8 https://doi.org/10.3109/00016359509005982
  22. Waltimo A, Nystrom M, Kononen M. Bite force and dentofacial morphology in men with severe dental attrition. Scand J Dent Res 1994;102:92-6
  23. Ferrario VF, Sforza C, Zanotti G, Tartaglia GM. Maximal bite forces in healthy young adults as predicted by surface electromyography. J Dent 2004;32:451-7 https://doi.org/10.1016/j.jdent.2004.02.009
  24. Strub JR, Beschnidt SM. Fracture strength of 5 different all-ceramic crown systems. Int J Prosthodont 1998;11:602-9