• Title/Summary/Keyword: 단열 조

Search Result 100, Processing Time 0.029 seconds

A Case Study of Geometrical Fracture Model for Groundwater Well Placement, Eastern Munsan, Gyeonggido, Korea (지하수개발을 위한 단열모델 연구사례(경기도 문산 동쪽지역))

  • Choi Sung-Ja;Chwae Uee-Chan;Kim Se-Kon;Park Jun-Beom;Sung Ki-Sung;Sung Ik-Whan
    • Economic and Environmental Geology
    • /
    • v.39 no.2 s.177
    • /
    • pp.163-171
    • /
    • 2006
  • This study is the case of groundwater development based on the geometrical fracture model of target area established only through geological fracture mapping technique. A fracture mapping of $9km^2$, eastern Munsan, has been conducted to determine geological and hydrological factors for new water well placement in the Gyeonggi gneiss complex. Geophysical exploration was not applicable because of small restricted area and dense underground utilities at the site. Form line mapping on the basis of foliation orientation and rock type revealed a synform of NS fold axis bearing to the south. An EW geological cross-section passed through the site area shows a F2 synform as a double-wall ice cream spoon shape. Three regional faults of $N20^{\circ}E,\;N30^{\circ}W$, and NS have been dragged into the site to help understand extensional fault paths. The $N20^{\circ}E$ fault with dextral sense is geometrically interpreted as a western fault of two flexural conjugate type-P shear faults in the F2 synformal fold. The NE cross-section reveals that a possible groundwater belt in the western limb of super-posed fold area is formed as a trigonal prism within 100 m depth of the intersectional space between the $N20^{\circ}E$ fault plane and the weakly sheared plane of transposed foliation. Another possible fault for water resource strikes $N40^{\circ}E$. Recommended sites for new water well placement are along the $N20^{\circ}E\;and\;N40^{\circ}E$ faults. As a result of fracture mapping, 145 ton/day of water can be produced at one well along the $N20^{\circ}E$ fault line. Exploration of groundwater in the area is succeeded only using with geological fracture mapping and interpretation of geological cross-section, without any geophysical survey. Intersection of fault generated with the F2 synformal fold and foliation supply space of groundwater reserver.

Structural Load Bearing Capacity of Wall System Framed by Studs and Runners using Square Steel Tubes (각형강관을 이용한 스터드-런너 골조형 벽체시스템의 구조내력 성능평가)

  • Kim, Ho Soo;Hong, Seok Il;Lim, Young Do
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.3 s.76
    • /
    • pp.253-262
    • /
    • 2005
  • Because the framed wall system using steel studs and runners with square steel tubes as structural elements is reinforced by the horizontal members called runners, it has more strength and load bearing capacity than the steel house wall system. Also, this system improves adiabatic and sound insulation performance by filling up the autoclaved lightweight concrete. We need to evaluate load bearing capacity according to the axial load and lateral load in case this system is applied in the housing system with 3~5 stories through variations in intervals for the runners under the placement effect of autoclaved lightweight concrete. Therefore, this study seeks to analyze axial and shear behavior of the framed wall system according to the placement effect of autoclaved lightweight concrete, and to secure safety for the vertical and lateral loads.

Geology and Geochemistry of Volcanic and Sedimentary Rocks from Deep Borehole in the Heunghae area, North Kyungsang Province (경북 흥해지역 심부시추공의 화산암 및 퇴적암류의 지질 및 지화학적 연구)

  • Lee, Chang-Bum;Kim, Tong-Kwon;Park, Deok-Won
    • The Journal of Engineering Geology
    • /
    • v.19 no.4
    • /
    • pp.459-474
    • /
    • 2009
  • By the analysis of discontinuity at the outcrop and lineament on the satellite image, the joints have deeply relationship with the lineaments. The joint spaces at the drilling core are mostly 1~20 cm but at the rhyolite which is distributed near fault they have more closely. These volcanic rocks belong to the subalkaline series tuff, rhyolite, basalt in the study area from the diagram of $Nb/Y-Zr/TiO_2$. The composition diagram of Hf/3-Th-Nb/16 show destructive plate-margin basalt and their differentiates. The environment of formation of volcanics are normal continental arc. Most of LREE show high enriched pattern but HREE show depleted pattern. The K/Ar age of intermediate volcanics, tuff, rhyolite, crystal tuff are 55.3Ma, 77.25 Ma~91.22Ma, 63.16~64.39Ma, 54.49 Ma respectively.

Static Cyclic Loading Test of the Seismic and Energy Simultaneous Retrofit Panel for Existing Unreinforced Masonry Buildings (기존 비보강 조적조 건축물의 내진 및 에너지 동시보강패널 정적반복가력실험)

  • Choi, Hyoung-Wook;Lee, Sang-Ho;Choi, Hyoung-Suk;Kim, Tae-Hyeong;Baek, Eun-Rim
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.4
    • /
    • pp.81-90
    • /
    • 2020
  • A textile and capillary tube composite panel(TCP) was developed to simultaneously retrofit the seismic performance and the energy efficiency (e.g. heating or insulation performance) of existing unreinforced masonry (URM) buildings. TCP is a light-weight mortar panel in which carbon textile reinforcements and capillary tubes are embedded. Textile reinforcements plays a role of seismic retrofit and capillary tubes that hot water circulates contribute to the energy retrofit. In this paper, the static cyclic loading tests were performed on the masonry walls with/without TCP to understand the seismic retrofit effect of TCP retrofit and the results were summarized. The results of the test showed that the TCP contributed to increase the capacity of the Shear strength and ductility of the URM walls. In addition, the deformation of the wall after cracking was substantially controlled by the carbon textile.

Shield Ratio and Thrust Performance Analysis According to The S-Type Nozzle of The Centerline Shape (S-형 노즐 형상의 중심선 형태에 따른 차폐율과 추력 성능 해석)

  • Jin, Juneyub;Park, Youngseok;Kim, Jaewon;Lee, Changwook
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.25 no.3
    • /
    • pp.42-55
    • /
    • 2021
  • In this study, the effect of nozzle performance according to the selection of the center line equation. Three of S-type nozzles and three of double S-type nozzles were designed using the curve equation and design parameters, and the nozzle shielding performance was evaluated using the shielding ratio definition. In order to analyze the internal flow of the nozzle, the characteristics of the velocity distribution and pressure distribution were studied, and the nozzle performance was evaluated through the total thrust ratio(f) and the nozzle insulation efficiency coefficient(η). On the other hand, the centerline with a sharply change in curvature at the entrance has a low nozzle performance and a high shielding rate. The double S-type nozzle is excellent nozzle performance and shielding rate by using a smooth centerline at the first curvature.

Hydrogeological Site Monitoring in Low and Intermediate Level Radioactive Waste Disposal Facilities (중·저준위 방사성 폐기물 처분시설의 부지 감시 현황)

  • Chung-Mo Lee;Soon Il OK;Seongyeon Jung;Sieun Kim
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.17-17
    • /
    • 2023
  • 국내의 부지특성 및 감시 관련 규정은 원자력 안전위원회 고시 제2021-16호 제4조(세부지침)와 원자력 안전위원회 고시 제2021-17호 제16조에 의거하고, 국외는 국제원자력기구(IAEA: International Atomic Energy Agency)에서 안전기준을 제시하고 있다(IAEA, 2011). 따라서 국내 중·저준위 방사성폐기물 처분시설은 2006년부터 광역 지질을 포함한 부지 지질/지형, 기상, 수문, 수리지질, 인문사회 등을 망라한 조사를 시행하여 부지 현황에 대한 분석 및 안정성 평가를 수행한다. 부지감시의 수문·지구화학 분야에서는 현장 수질 측정 6항목과 실내 분석 26항목을 감시하고 있으나, 본 연구는 이 중 9개 항목(EC, Na, K, Ca, Mg, SiO2, Cl, SO4, HCO3)을 선정하여 분석하였다. 연구 목적은 물시료 분석자료의 주성분-다중선형회귀-군집 분석과 Piper Diagram 분석결과로부터 해수와 담수(지하수)와의 특성분석 및 해수 영향을 분석하는 것이다. 현장 부지내 지하수 7개 관정(GM-1, 2, 4, 5, 6, 7, 8)과 해수 2개 지점(Sea-1, 2)을 대상으로 통계학적 주성분 분석결과, 대부분의 지하수는2개~4개의 요인으로 구분되고, 해수와의 유사성을 해석하기 위해 확인한 관정은 GM-5, GM-6, GM-1 지점으로 분류되었다. 상기와 같이 해수의 영향을 확인하기 위해 해수 2개 지점과 동일한 군집으로 분류되는 지하수는 GM-5 관정으로 확인되었고, 해안선에서 가까운 GM-5 관정과 같이 유사한 거리에 분포한 지하수 GM-1, 2, 4 관정은 2개 혹은 3개의 최적 군집으로 분류하였을 때도 GM-5와는 다른 특성을 보여주었다. 이는 해안과 인접하더라도 수질은 다른 지질학적 특성(지형, 기상, 단열대 등)에 따라 영향받았음을 지시한다.

  • PDF

The Energy Performance Evaluation of Multi-purpose Solar Window System (다기능 복합 솔라윈도우 시스템의 에너지성능평가)

  • Cho, Yil-Sik;Kim, Byoung-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.3
    • /
    • pp.10-15
    • /
    • 2010
  • The aim of this study was to analysis the Heating/cooling performance of Solar Window System built in apartments. The solar window is the idea to integrate daylight as a third form of solar energy into a PV/Solar Collector system and allows more control due to the possibility to close the reflectors. However, there can be a conflict between the desire for on one hand daylight and view and on the other hand optimal energy conversion for the PV/Solar Collector system. The process of this study is as follows: 1) The Solar Window system is designed through the investigation of previous paper and work. 2)The simulation program(ESP-r, Therm5.0, Window6.0) was used in energy performance analysis. The reference model of simulation was made up to analysis energy performance on Solar Window system. 3)Selected reference model(Floors:15, Area of Unit:$148.5m^2$) for heating/cooling energy analysis, Energy performance simulation with various variants, such as U-value of Solar Window system according to its position and angle. Consequently, When Solar Window system is equipped with balcony window of Apartment, Annual heating and cooling energy of reference model was cut down about 5%~11%.

The Study of Thermal Performance on Solar Window (다기능 솔라윈도우의 열성능 연구)

  • Cho, YilSik;Kim, Janghoi;Yang, Yoonsub;Kim, ByoungSoo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.65.2-65.2
    • /
    • 2010
  • The aim of this study was to analysis the Heating/cooling performance of Solar Window built in apartments. The solar window is the idea to integrate daylight as a third form of solar energy into a PV/Solar Collector system and allows more control due to the possibility to close the reflectors. However, there can be a conflict between the desire for on one hand daylight and view and on the other hand optimal energy conversion for the PV/Solar Collector system. The process of this study is as follows: 1) The Solar Window system is designed through the investigation of previous paper and work. 2)The simulation program(ESP-r, Therm5.0, Window6.0) was used in Heating/cooling performance analysis. The reference model of simulation was made up to analysis Heating/cooling performance on Solar Window. 3)Selected reference model(Floors:15, Area of Unit:$148.5m^2$) for heating energy analysis, Energy performance simulation with various variants, such as U-value of Solar Window system according to its position and angle. Consequently, When Solar Window system is equipped with balcony window of Apartment, Annual heating and cooling energy of reference model was cut down about 5%~11%.

  • PDF

Experimental Study of Liquid Oxygen Sub-cooling by Helium Injection (헬륨분사를 통한 액체산소 과냉각에 관한 실험적 연구)

  • Kwon Oh-Sung;Cho Nam-Kyung;Chung Yong-Gahp;Ha Seong-Up;Lee Joong-Youp;Kim Hyun-Joong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • v.y2005m4
    • /
    • pp.179-182
    • /
    • 2005
  • Test of liquid oxygen sub-cooling by helium injection, which is one of the method of temperature conditioning of cryogenic propellant in liquid propulsion rocket, is performed. The sub-cooling effect at different He injection flow rate with the same initial liquid oxygen mass is compared. Test results showed liquid oxygen temperature decrease of $5\sim6^{\circ}C$ under test condition. And the required time for cooling is inversely proportional to He injection flow rate.

  • PDF

Design and Implementation of Automatic Control System in Room using Sensor (센서를 이용한 자동 실내 온도 제어시스템 설계 및 구현)

  • Jeong, Gyu-Tae;Lee, Eun-Jin;Kim, Heung-Soo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.326-328
    • /
    • 2015
  • Function of the window of the building is an environment of the room through the entry of solar radiation. It is vulnerable to significant energy conservation off the thermal efficiency. Also this summer, cooling costs are weighted because of excessive solar radiation. In this paper, we develop a windows automatic control system to use the indoor environmental information, such as home temperature, humidity, light intensity, solar radiation. The system collects the indoor environment information using a variety of sensor, using the collected information, and controls the motor to the system to control the window.

  • PDF