• Title/Summary/Keyword: 단순 방사선

Search Result 495, Processing Time 0.024 seconds

The usefulness of Forward IMRT for Head and Neck Cancer (두경부(Head & Neck)종양에서 Forward IMRT 유용성에 관한 고찰)

  • Baek Geum Mun;Kim Dae Sup;Park Kwang Ho;Kim Chung Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.15 no.1
    • /
    • pp.41-52
    • /
    • 2003
  • I. Purpose The dose distribution in normal tissues and target lesions is very important in the treatment planning. To make the uniform dose distribution in target lesions, many methods has been used. Especially in the head and neck, the dose inhomogeneity at the skin surface should be corrected. Conventional methods have a limitation in delivering the enough doses to the planning target volume (PTV) with minimized dose to the parotid gland and spinal cord. In this study, we investigated the feasibility and the practical QA methods of the forward IMRT. II. Material and Methods The treatment plan of the forward IMRT with the partial block technique using the dynamic multi-leaf collimator (dMLC) for the patients with the nasopharyngeal cancer was verified using the dose volume histogram (DVH). The films and pinpoint chamber were used for the accurate dose verification. III. Results As a result of verifying the DVH for the 2-D treatment plan with the forward IMRT, the dose to the both parotid gland and spinal cord were reduced. So the forward IMRT could save the normal tissues and optimize the treatment. Forward IMRT can use the 3-D treatment planning system and easily assure the quality, so it is easily accessible comparing with inverse IMRT IV. Conclusion The forward IMRT could make the uniform dose in the PTV while maintaining under the tolerance dose in the normal tissues comparing with the 2-D treatment.

  • PDF

A Statistical Study of Radiolucent Foreign Bodies in Food and Air Passage (단순 흉부 방사선 검사상 발견되지 않은 식도 및 기도 이물의 임상 통계적 고찰)

  • 손영규;이창업;배광식;박문서;이선철
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1983.05a
    • /
    • pp.9.2-9
    • /
    • 1983
  • We have observed 74 cases of radiolucent foreign bodies in food and air passage in E. N. T. department of Hang Gang Sacred Hospital, from Jan. 1972 to Mar. 1983. The following results were obtained. 1) Distribution of location was 56 cases(75.6 %) in food passage and 18 cases (24.4 %) in air passage. 2) In age distribution, 46 cases (82.1 %) of F. B. in food passage were found in patient over 21 years old and 12 cases (66.7 %) of F. B. in air passage were found in patient under 5 years old. 3) Female seems to be more frequently involved than male in cases of F. B. of food passage and in cases of air passage, male is more frequent. Food passage male: female - - - 25 : 31 Air passage male: female - - - 10 : 8 4) Meats was the most frequent foreign body in food passage (19 cases-33.9%), and the bony pieces was next (17 cases-30.4 %). Plastic material was the most frequent foreign body in air passage (9 cases-49.9 %), and the vegetable seed was the second (4cases-22.0 %). 5) In the location of F. B. in food passage, the first narrowing of the esophagus was the most frequent site and in air passage, the bronchus-especially right bronchus-was the most frequent site. 6) In the duration of lodgement, 44 cases(78.6 %) of F.B. in food passage were visited with - in 24 hours, and 11 cases (61 %) of F. B. in air passage were visited with - in 24 hours. 7) Simple chest PA was checked in all patient and then, esophagogram was checked in 34 cases of F.B. in food passage, among them positive finding was noticed in 23 cases. 8) Removal of F. B. in food passage by esophagoscopy was performed in 54 cases (96.4 %), but in the cases of air passage, removal of F. B. by bronchoscopy was performed in 14 cases (77.8 %). 9) Complications of food passage by the F. B. itself or esophagoscopy were esophageal mucosal laceration (1 cases-1.8 %) and esophageal perforation (1 case -1. 8 %) and complication of air passage by F. B. itself or bronchoscopy were atelectasis (2 cases -11.1 %) and pneumonia (3 cases-16.7 %).

  • PDF

Acromial Morphology in Different MR Oblique Sagittal Slices: Correlation with Rotator Cuff Disorder (자기 공명 영상의 사 시상면에서의 견봉 형태의 변화: 회전근 개 질환과의 임상적 연관성 분석)

  • Jo, Chris H.;Kim, Ji-Beom;Choi, Hye-Yeon;Ko, Young-Whan;Yoon, Kang-Sup;Lee, Ji-Ho;Kang, Seung-Baik;Lee, Jae-Hyup;Han, Hyuk-Soo;Rhee, Seung-Whan
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.2
    • /
    • pp.173-179
    • /
    • 2009
  • Purpose: On the hypothesis that the acromion morphology is changed according to the its site, we identified the morphology of the acromion on the oblique slices of MRI and we investigated the association of the acromial shape with the clinical stages of rotator cuff disorder on the magnetic resonance (MR) images. In addition, we compared the acromion morphology on MRI and simple X-rays. Material and Methods: The MR images of seventy one patients with rotator cuff disorder and who underwent arthroscopic surgery were compared with that of a control group of sixteen patients who didn't have rotator cuff disorder on MRI. On three subsequent oblique sagittal slices from the lateral edge of the acromion (S1, S2 and S3), each acromion morphology on the MRI slices was classified according to Epstein et al: flat, curved or hooked. We investigated the changing parttern of the acromion shape and we compared the acromion shape on MRI and that on simple X-rays. We classified the rotator cuff tear by the severity: bursitis, partial thickness tear or full thickness tear. We investigated which acromial type on the MRI oblique slice was associated with the severity of rotator cuff disease. Results: Changes of the acromial shape occurred in 54 patients (76.1%). The most frequent pattern was that the types are same on S1 and S2 and different on S3 (22 cases, 31.0%). The acromial type on S1 and S2 was significantly associated with the severity of rotator cuff disorder (p=0.001 and 0.022), respectively. There was no reliability of the acromial shape on MRI and roentgenography (p>0.05) Conclusion: The type of acromion changed from lateral to medial. Among the three positions, the shape of the acromion on S1 and S2 had meaningful correlation with the clinical stage of rotator cuff disorder. There was no statistical correlation of the acromial shape between MRI and simple X-ray.

Evaluation of Normal Abdominal Organs by Diagnostic Imaging in the Premature Miniature Pig (미성숙 미니돼지에서 방사선과 초음파를 이용한 복부장기의 평가)

  • Chang, Jin-Hwa;Jung, Joo-Hyun;Oh, Sun-Kyoung;Choi, Min-Cheol
    • Journal of Life Science
    • /
    • v.19 no.3
    • /
    • pp.417-421
    • /
    • 2009
  • This report describes the normal radiographic and ultrasonographic morphological features of premature minipigs at 4, 8, 12 and 20 weeks of age. Radiographic examination is a simple diagnostic method used to identify the general morphologic state of major organs and their adjacent structures, and to assess the presence of abnormalities. The parameters for evaluation in plain abdominal radiographs are the degree of diffuse serosal margin details, extent of visualization of each organ, their size, shape, and contour, locations of main organs - such as the liver, stomach, spleen, kidneys, urinary bladder - the distribution of the intestines, and assessment of the retroperitoneal space and its contents. Ultrasonographic examinations are used to investigate their internal condition. The parameters for evaluation in abdominal ultrasonography are echogenicity, echotexture, and size and shape of the main organs such as the liver, spleen, kidney, urinary bladder and gastrointestinal tract. Minipigs had similar findings compared to dogs or cats.

A Study on the Result of Test Site on BMD (골다공증 검사 시 검사부위에 따른 결과에 대한 고찰)

  • Hong, Dong-Hee;Han, Sang-Hyun;Jung, Hong-Ryang
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.19-24
    • /
    • 2013
  • The measurement of Korea people's Radial-terminal region were frequently measure of the left hand of Radial-terminal region due to the most Korean's are right-handed and it occasionally showed incorrect results. Therefore, in this study, we accessed a correlation with error of measurement and reduced the measurement error invalid. We reviewed 50 adults patients, from March 2012 for a certain period of time, visited the orthopedic center for the neutral position of forearm of plain radiography and measured the left side of the distal radial-terminal region containing the terminal region of the right distal radius. Then we have compared and analysed both T-score. As a result, the lower value of left wrist were 45 out of 75 which is approximately 60% of left wrist group while the lower value of right wrist were 30 out of 75 which is approximately 40% of right wrist group.

A Study of Radiographic Methods to X-ray Study of Patients with Spinal Scoliosis and Vertebrae Bone Fracture of Lumbar Spine (척주측만증과 허리뼈 골절 수술 환자의 엑스선 촬영법 연구)

  • Ahn, Byung-Ju;Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.425-431
    • /
    • 2019
  • The Study In order to obtain images of overlap of the two iron cores in the spinal cord simple x-ray scan after surgery of patients with ulcer lateral sclerosis and a fractured backbone, the researcher conducted a subjective evaluation on five radiographers of the university hospital's imaging department for more than 10 years. The results of the experiment showed that the lateral shot of lateral scoliosis of the spinal cord was taken with the middle face of the IR plane, and then the X-ray tube angle was taken vertically with the vertical spinal column fan-tom position, resulting in two overlapping images and high scores in the subjective evaluation. In addition, lateral shots of the lumbar dislocation fractured lumbar vertebrae were taken with the forehead aligned with the center of the IR plane and then with the X-ray angle perpendicular to the fourth waistline and the angle of the spinal cord perpendicular to the fourth waistline, the image of the two iron cores could be obtained from the radiographer.

A Cosideration on Physical Aspects in Teleradiotherapy Chart QA (원격방사선치료 기록부의 QA 에서 물리적 측면의 고찰)

  • 강위생;허순녕
    • Progress in Medical Physics
    • /
    • v.10 no.2
    • /
    • pp.95-101
    • /
    • 1999
  • The aims of this report are to classify the incorrect data of patients and the errors of dose and dose distribution observed in QA activities on teleradiotherapy chart, and to analyze their frequency. In our department, radiation physicists check several sheets of patient chart to reduce numeric errors before starting radiation therapy and at least once a week, which include history, port diagram, MU calculation or treatment planning summary and daily treatment sheet. The observed errors are classified as followings. 1) Identity of patient, 2) Omitted or unrecorded history sheet even though not including the item related to dose, 3) Omission of port diagram, or omitted or erroneous data, 4) Erroneous calculation of MU and point dose, and important causes, 5) Loss of summary sheet of treatment planning, and erroneous data of patient in the sheet, 6) Erroneous record of radiation therapy, and errors of daily dose, port setup, MU and accumulated dose in the daily treatment sheet, 7) Errors leading inexact dose or dose distribution, errors not administerd even though its possibility, and simply recorded errors, 8) Omission of sign. Number of errors was counted rather than the number of patients. In radiotherapy chart QA from Jun 17, 1996 to Jul 31, 1999, no error of patient identity had been observed. 431 Errors in 399 patient charts had been observed and there were 405 physical errors, 9 cases of omitted or unrecorded history sheet, and 17 unsigned. There were 23 cases (5.7%) of omitted port diagram, 21 cases (5.2%) of omitted data and 73 cases (18.0 %) of erroneous data in port diagram, 13 cases (3.2 %) treated without MU calculation, 68 cases (16.3 %) of erroneous MU, 8 cases (2.0%) of erroneous point dose, 1 case (0.2 %) of omitted treatment planning summary, 11 cases (2.7%) of erroneous input of patient data, 13 cases (3.2%) of uncorrected record of treatment, 20 cases (4.9%) of discordant daily doses in MU calculation sheet and daily treatment sheet, 33 cases (8.1%) of erroneous setup, 52 cases (12.8%) of MU setting error, 61 cases (15.1%) of erroneous accumulated dose. Cases of error leading inexact dose or dose distribution were 239 (59.0 %), cases of error not administered even though its possibility were 142 (35.1 %), and cases of simply recorded error were 24 (5.9 %). The numeric errors observed in radiotherapy chart ranged over various items. Because errors observed can actually contribute to erroneous dose or dose distribution, or have the possibility to lead such errors, thorough QA activity in physical aspects of radiotherapy charts is required.

  • PDF

Correlation of the Ultrasonography with the Physical Examinations and Simple Radiography in Measurement of Amount of Effusion of the Knee Joint (슬관절 활액 양 측정에서의 신체검사와 단순 방사선 검사, 초음파의 상관성)

  • Kim, Jung-Man;Ra, Ki-Hang;Nam, Ho-Jin;Lee, Jung-Woo
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.3 no.1
    • /
    • pp.15-20
    • /
    • 2010
  • Purpose: The goal of this study is to find out how useful ultrasonography is in measuring amount of effusion within the knee joint in comparison with physical examination and simple radiography. Materials and Methods: We evaluated total 60 cases which were suspicious for joint effusion. Average age was 61.3 years. The group was consisted of 22 males and 38 females, and 24 obese people and 36 non-obese people. Stroke test and patella floating test were done as physical examination. Amount of joint effusion was classified into 3 groups in simple lateral radiographic view and ultrasonography was used for recheck-up. Results: 39 cases were found positive in stroke test, and patella floating was shown in 20 cases. In simple lateral radiographic view, 47 cases of grade I, 7 cases of grade II and 3 cases of grade III were checked. Average $7.67{\pm}2.90mm$ amount of effusion was checked by ultrasonography. Amount of fluid in stroke test, patella floating test and simple lateral radiographic view showed close correlation with ultrasonography. Gender did not seem to affect physical examination, but strong correlation was found in female in simple radiography. Obese group showed closer relationship with all 3 exams compared with non-obese group. Physical examination was relatively effective with nonobese group, but not with obese group. And it was not easy to measure the amount of fluid with simple radiographic view, but we could obtain objective data from ultrasonography by measuring the amount of effusion dynamically. Conclusion: We concluded that more objective data was obtained with ultrasonography in comparison with physical examinations and simple radiography in the aspect of measuring amount of joint fluid.

  • PDF

Postoperative Adiuvant Radiation Therapy in Endometrial Carcinoma (자궁내막암의 수술 후 보조적 방사선치료)

  • Shin Kyung Hwan;Choi Eun Kyung;Ahn Seung Do;Chang Hyesook;Mok Jung-Eun;Nam Joo Hyun;Kim Young Tak;Kim Yong Man;Kim Jong Hyeok
    • Radiation Oncology Journal
    • /
    • v.18 no.1
    • /
    • pp.40-45
    • /
    • 2000
  • Purpose : To evaluate the histopathological prognostic factors, relapse pattern and survival in patients with endometrial carcinoma who were treated with surgery and postoperative adjuvant radiotherapy (RT). Methods and Materials : From September 1991 to December 1997, 27 patients with endometrial carcinoma treated with surgery and postoperative adjuvant RT at Asan Medical Center were entered in this study. Surgery was peformed with total abdominal hysterectomy in six, total abdominal hysterectomy with pelvic lymph node dissection in eight and radical hysterectomy in 13 patients. External RT of 50.4 Gy was done to all patients and among these, additional high dose rate vaginal vault irradiation of 20$\~$25 Gy with fractional dose of 4$\~$5 Gy was boosted In 16 patients. The patients were followed for 6$\~$95 months(median 30). Results : The number of patients according to FIGO stage were I 18 (67$\%$), II 1 ($4\%$) and III 7 ($26\%$). Patients with poor histologic grade, deep myometrial invasion, adnexal involvement, lymphovascular invasion showed more pelvic lymph node involvement, but no statistical significance was indicated. The 5 year overall and disease free survival were 100$\%$ and 76.8$\%$, respectively. Relapse sites were pelvic, para-aortic lymph node, and multiple metastases including lung, and no vaginal relapse was developed. Factors that were associated with disease free survival were FIGO stage (p=0.01), lymphovascular invasion (p=0.03), pelvic lymph node involvement (p=0.0001). There was only one Grade 1 rectal bleeding without moderate to severe complications. Conclusion : Postoperative adjuvant RT is considered to reduce the loco-regional failure, resulting the improvement of survival. The group of patients with the risk of vaginal failure without vaginal vault irradiation should be investigated according to stage and grade.

  • PDF

Development of Biodegradable Polymeric Membrane for Interventional Procedure: Preliminary Study (인터벤션 시술을 위한 생분해성 고분자막의 개발 : 예비연구)

  • Bang, Jung-Wan;Hyun, Chang-Yong;Kim, Tae-Hyung;So, Woon-Young;Kim, Jin-Tae;Kim, Sang-Sub;Jung, Hee Dong;Heo, Yeong Cheol
    • Journal of radiological science and technology
    • /
    • v.37 no.1
    • /
    • pp.15-20
    • /
    • 2014
  • This study was to evaluate clinical feasibility of biodegradable polymeric membrane for interventional procedure in preliminary study. Bio-degradable polymetric membrane was produced into a solution by mixing hyaluronic acid powder with NaOH solution in a heating mantle. Three different concentrations of contrast media (10, 20, and 30 vol%) were added to the produced soluble powder, and vertical agitation was performed for 12 hours at a speed of 100 to 200 rpm at a room temperature. It was freeze dried for 24 hours at a temperature $80^{\circ}C$. Pressure on the freeze dried sample was exerted by a hydraulic press in order to form the freeze dried sample into a membrane. The membrane produced with varying contrast medium concentration was visually examined by a scanning electron microscope and radiographically inspected. Under the visual examination, the higher the concentration of contrast medium, the rougher the surface. Radiographic transparency was similar under all conditions of fluoroscopic radiography, simple radiography, and serial radiography. In conclusion, this preliminary study verified that bio-degradable membrane produced with hyaluronic acid was a material with clinical usability.