• Title/Summary/Keyword: 다중접지

Search Result 76, Processing Time 0.031 seconds

An Elimination Method Of the Circulating Current Flowing into Coaxial-Neutral Lines in 22.9[kV] CNCV Underground Cable Systems (22.9[kV] 지중배전계통케이블의 동심중성선에 흐르는 순환전류의 제거방안 및 효과)

  • Jeon, Myung-Su;Song, Joong-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.2
    • /
    • pp.107-113
    • /
    • 2008
  • In 22.9[kV]-y distribution systems, underground cables are provided with multiple-point ground in which each coaxial-neutral line of the distribution cable lines(A, B, C phases) is 3-wire common grounded. In the underground cable distribution systems, circulating current flows in the coaxial-neutral lines and its magnitude amounts to about $40{\sim}50[%]$ load currents, even though loads are balanced. Power loss due to the circulating current consequently reaches to about 76[%] total losses occurred in all conductor lines. This power loss provokes additional temperature rise of the underground cable lines and finally results in 20[%] reduction of the current capacity of the cables. This paper presents a new ground method to overcome such a problem. The proposed method eliminates the circulating current flowing in the coaxial-neutral line effectively. Measurement results confirmed from the practical site-test show validity and effectiveness of this research.

Design and Fabrication of Mulitiple U-shaped slot Microstrip Antenna on 5㎓ Application (5㎓ 대역에서 동작하는 다중 U-슬롯 모양의 마이크로스트립 안테나의 설계 및 제작)

  • 윤중한;정계택;이상목;안규철;곽경섭
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.40 no.11
    • /
    • pp.85-92
    • /
    • 2003
  • In this paper, a multiple U-shaped slot antenna on 5㎓ band is designed, fabricated, and measured. The prototype consists of a U-shaped slot and two Invert U-shaped slot. To obtain wide bandwidth, the foam layer is inserted between ground plane and substrate. After various parameters, length, width, position of U-shaped slot horizontal, interval length between two invert U-shaped slot, feeding position and airgap width, optimized, a multiple U-shaped slot antenna is fabricated and measured. The measured results of the antenna are compared with its simulated results. A 2:1 VSWR impedance bandwidth of 20.4% is achiedved by employing this technique. The gain is about 5.5㏈i. The experimental far-field patterns are stable across the pass band.

A Design of Multi-band Antenna using asymmetric Bow-tie structure (비대칭 보우 타이 구조를 이용한 다중 대역 안테나 설계)

  • Jang, Jeong-Seok;Kim, Dae-Woong;Choi, Yong-Gyu;Hong, Ui-Seok
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.9 no.2
    • /
    • pp.41-50
    • /
    • 2010
  • In this paper, a multi-band antenna with novel structure for mobile communications is designed and fabricated. The proposed antenna has the Multi-band antenna characteristics by two common-grounded slots with different size and angle. In order to reduce size and to enhance the gain of the antenna, a reflector is consisted of chokes on the three sides. It is optimized by using the CST Microwave Studio commercial software based on the FIA(Finite Integration Algorithm) and PBA(Perfect Boundary Approximation), and then the fabricating and measuring is practiced. As a result of measurement, the reflection coefficient is less than -11 dB(VSWR < 1.8) and the gain of antenna is more than 6dBi at 824~894MHz and 1885-2500MHz.

Transients Analysis for Parameters on Electrical Distribution System (배전시스템에서의 파라미터에 따른 과도현상 분석)

  • 김재철;오정환;임성정
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.3
    • /
    • pp.88-96
    • /
    • 1997
  • This paper analyzes the transients for parameters on electrical distribution system. We analyze the voltage sag and switching surge caused by reclosing and develope a distribution system model of multiground type using a practical data of 22.9(kV) distribution system. It is at customer that we analyze an affecting of reclosing through EMTP (Electromagnetic Transients Program) simulation, present transient phenomena on fault line and parallel line. Also. we analyze the various parameters affecting this phenomena in detail through parametric analysis. These factors include the fault location, load size, load power factor, capacitor bank size, and reclosing angle. And relation between these parameters and transient phenomena is presented.

  • PDF

Multi-band Ceramic Chip Antennas Design for Portable Phones (휴대용 단말기 내장형 다중 대역 세라믹 칩 안테나 설계)

  • Lee Yoon-Do;Kim Yeong-Jun;Lee Sang-Won;Lee Yong-Gi;Jeong Eum-Min;Park Yeong-Ho;Cheon Chang-Yul
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.17-20
    • /
    • 2002
  • 본 논문에서는 세라믹 칩 안테나를 LTCC로 구현하여 다중 대역 특성을 얻는 방법을 제안하고 있다. 휴대용 단말기에 칩 안테나를 내장함으로 물리적 손상을 피하고 위치추적 시스템(GPS) 대역과 단말기 송수신용 대역, 즉 두 대역 이상 사용 가능하고 ${\varepsilon}_r=7.8$인 세라믹 칩 안테나를 LTCC(Low Temperature Co-fired Ceramic)공정을 이용하여 세라믹 칩 내부에 정합 회로를 구현하여 이중 대역 특성을 갖는 구조에 대해 논의하고 있다. 안테나의 전체 크기는 $16mm{\times}4mm{\times}2mm$ 이며 대역폭은 삽입손실 -10dB 기준 대략 1560MHz에서 2160MHz까지 약 600MHz정도이다. 측정은 접지면의 넓이가50mmx50mm이고 두께=0.7874mm, ${\varepsilon}_r=4.6$인 FR4 기판을 이용하여 측정한다.

  • PDF

Design of a Multiband MIMO Antenna for USB Dongle Application (USB Dongle에 적용을 위한 다중 대역 MIMO 안테나 설계)

  • Lee, Young-Ki;Choi, Jea-Hoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.4
    • /
    • pp.441-448
    • /
    • 2012
  • This paper proposes a multiband Multi-Input Multi-output(MIMO) antenna for universal serial bus(USB) dongle application. The proposed MIMO antenna consists of a modified meander strip line and inverted L stub. The two radiating elements of the MIMO antenna are symmetrically placed with respect to the center of the ground plane. The fabricated antenna satisfied a VSWR below 3 and an efficiency over 35 % in the LTE band 13, 17(704 MHz-787 MHz), DCS/PCS/WCDMA band(1.71 GHz-2.17 GHz), and LTE band 7(2.5 GHz-2.7 GHz). The envelope correlation coefficient(ECC) has below 0.45 in the LTE band 13, 17 and 0.1 in the DCS/PCS/WCDMA band and LTE band 7, respectively.

A Study on Diagnosis of The Energized Status of 22.9kV Multigrounded Underground Power Cable (22.9kV 다중 접지 지중 전력 케이블의 가압 상태 진단에 관한 기초 연구)

  • Kim, Chang-Gyo;Hong, Jin-Su;Jeong, Yeong-Ho
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.10
    • /
    • pp.699-703
    • /
    • 1999
  • An experimental study to identify the energized status of the 22.9kV underground power cable by the detection of vibration has been performed. We have derived that there exists vibration at double the line frequency in live cables by electromagnetic force. The relative amplitudes of the cable vibration according to the energized status of the cable were calculated by computer simulation. The cable vibration can also be picked up by accelerometer. A prototype was tested on the underground distribution system in Chonan substation, KEPCO. Comparison between simulation results and field test results was performed. The results showed that the energized status of the calble can be identified by measuring the vibration of the cable using accelerometer.

  • PDF

Ground Fault Current Variation of 22.9kV Multi Neutral Grounded Distribution System with CD Type Superconducting Cable (22.9kV 중성점 다중접지계통에 CD형 초전도케이블을 적용한 경우의 지락전류변화)

  • Lee, Jong-Bae;Hwang, Si-Dole;Sohn, Song-Ho;Lee, Geun-Joon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.6
    • /
    • pp.993-999
    • /
    • 2007
  • This paper discusses the effects of CD type superconducting cable operation in 22.9kV multi neutral grounded distribution system during L-G fault and counterplans to power system protection. In case of using the 3-phase CD-type superconducting cable, the inductance of superconducting cable system would be decreased due to the current of shield part of superconducting cable, which is opposite direction and nearly equal value with respect to main superconductor. However, when the shield circuit system is operated in shorted state, shield current decreases faulted ground current and give effects to power system protection scheme. This study examines the phenomena of single line to ground fault case in above mentioned system using the EMTDC program and discusses the right operation method of superconducting shield.

Transformer-less Inverter for Photovoltaic and small unit Windturbine System (태양광 및 소단위 풍력발전용 변압기 없는 인버터)

  • 박영산;김윤식;이성근;안병원;배철오
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.333-336
    • /
    • 2003
  • Designed transformer-less inverter for photovoltaic and small unit windturbine power system. This system consisted of boost chopper circuit of multiple-switching method and foil bridge PWM inverter. Transformer-less system was adapted to reduce cost and size. But in this system, earth-leakage current have to be considered. So, to solve this problem, we used PWM inverter switching method to reduce the earth-leakage current which flows in accordance with the variation of DC input common mode voltage.

  • PDF

Characteristic Analysis of Multi-grounding System by Using a Scale Model Technique (축소모델기법을 이용한 다중접지계의 특성분석)

  • Lee, J.B.;Myung, S.H.;Chang, S.H.;Cho, Y.G.;Kim, J.S.;Kil, G.S.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1738-1740
    • /
    • 2003
  • This paper deals with the characteristic analysis of multi-grounding system. In order to assess the effectiveness of bonding two grounding systems, the scale model grounding simulation system and grid grounding conductors which were downsized as a scale factor of 100:1 were designed and fabricated. A profile of GPR(Grounding Potential Rise) of each case was measured. Also the measured results were compared with the analysis results.

  • PDF