• Title/Summary/Keyword: 다중이용업소법

Search Result 9, Processing Time 0.035 seconds

A Study on Improvement of Safety Management System of Publicly Used Establishments Through Analysis of the UK Regulatory Regime (영국 안전규제체계의 분석을 통한 국내 다중이용업소 안전관리체계의 개선방안 연구)

  • Park, Suhyeong;Yoon, Myong-O
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.4
    • /
    • pp.768-783
    • /
    • 2020
  • Purpose: In response to the critical risk of fire due to the characteristic of Publicly used establishments(hereinafter referred to as PUE), 'Special Act on the Safety Control of PUE' was enacted in 2006 and is still in operation. However, in spite of numerous revisions so far, still there are problems to be resolved. This study analyses the regulatory regime of fire safety in UK to find measures which could fundamentally improve the safety management of PUE. Method: This study compares and analyses the safety management system of PUE in Korea and the case of the UK by using the comparative research method. Result: As a result of the qualitative analysis, some noticeable systems and concepts of the UK regulatory regime have been discovered(e.g. 'Responsible person', 'Fire risk assessment', 'Fire safety audit', etc.) and consequently, 'Proposal for the Fire Safety Management System for PUE' is designed based on the findings from examples in the UK and drawbacks of safety management of PUE. Conclusion: This study proposes the way to improve the safety management of PUE into a more rational and effective system by analysing the case of the UK, which reorganised the fire safety management to the private sector centered, in which the fire authority minimizes intervention.

VR Theme Park Regulatory Improvement Plan (VR 테마파크 규제개선방안)

  • Song, Seung-Keun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.12
    • /
    • pp.1653-1658
    • /
    • 2018
  • This study aims to analyze the cases of VR space to improve the regulations. The space is divided according to the multi-use business act when the VR simulator and the VR game are simultaneously installed in a single space. It is necessary to amend the rules of the Tourism Promotion Act so that it can operate at a certain area of the youth game room subject to the Game Industry Law. Amendments that do not compartmentalize a space partition in the Multi-use Business Act should be carried out simultaneously. This is safer alternative by collective management rather than by the safety applied within a limited space by eliminating the compartment by industry. This is a legal amendment that allows VR simulator and VR game to be operated in the same space even in small sized amusement facilities such as other amusement facilities. This regulatory improvement plan is expected to help the activation of small sized VR theme parks.

A Study on Ways to Improve Safety Management through Analysis of Fire Cases in Multiple-user Buildings (다중이용업소의 화재사례 분석을 통한 안전관리 개선방안 연구)

  • Lee, Jae Wook
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.3
    • /
    • pp.191-201
    • /
    • 2022
  • In this study, we are going to derive problems for fire and safety management in multiple-user Buildings and suggest improvement measures to prevent recurrence through analysis of legal operation status for safety management of multiple-user Buildings and case studies of large-scale fires in multiple-user Buildings. For this study, first, the current state of the industry and fire occurrence status were investigated through theoretical considerations of the multi-use industry, and then the previous research on the multi-use industry was analyzed. and by analyzing the legal and institutional status of multiple-user Buildings, problems were derived through cases such as the Jecheon fire in Chungcheongbuk-do, the Inhyeon-dong fire in Incheon, and the Songpa-gu fire in Seoul. As a result, first, the necessity of strengthening the initial fire response capability. Second, thorough maintenance and management of emergency exits. Third, the need for rational regulation of upholstery. Fourth, reinforcement of fire safety education and training. Fifth, strengthening of installation standards for firefighting and safety facilities. Sixth, we derive the result that it is necessary to raise awareness about safety management, compare and analyze it with legal and institutional contents, and suggest solutions accordingly. When looking at the causes of fires in multi-use buildings, building owners, business owners, and employees think that there is no possibility of a fire occurring in their business premises, so there is a lack of awareness. It is necessary to raise awareness through education and publicity of firefighters and related administrative agencies.

난연도료 도포처리방법에 따른 난연성능특성

  • 노호성;이지섭;이영순
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2003.05a
    • /
    • pp.478-482
    • /
    • 2003
  • 최근 빈발하고 있는 다중이용업소의 화재와 이에 따른 인명피해에 대한 사회적 위기의식이 증대되고 있으며 내부구조를 전혀 모르는 불특정 다수인이 이용하는 관계로 화재발생초기에 대피할 수 있는 시간적인 여유를 최대한 확보하고 인명 및 재산피해를 최소화하기 위해서 국내 건축법상에는 내장재에 대한 난연화를 법률로 제정하고 있다.(중략)

  • PDF

A Study on the Application of the Regulation of the Interior Materials in Entertainment Occupancy (다중이용업소의 내장재 규정의 적용에 관한 연구)

  • 이주헌;윤명오;김운형
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.100-107
    • /
    • 2001
  • A Interior material, a main cause of fire-growth and generating toxic gas when it burns, should be dealt with great care in life safety design. Nonetheless, it has been used recklessly with undue attention to its contribution to fire in particular in entertainment occupancy and causes many victims in fire. Therefore, this study attempts to examine the current use of interior material in Korea and find out what to be improved and enhanced in terms of related regulations. Based on the comparison and analysis of the Korea regulation with those of advanced nations, suggestions are made for an effective and efficient improvement and complement to the current system. What can be suggested from this study are as follows. The use of interior material should be controlled under the unified regulation of fire-safety codes. Code should be set up so that the current construction enforcement should be applied in retroactive to those entertainment buildings that obtained a license prior to the implementation of the system certifying that the building is fire-resistant and fire-protective. The legislation should be made to control the fire-protection facilities of small-sized, underground entertainments. It should be obliged to present the blueprint displaying the use of interior material at the time of changing occupancy. Or, it should be compelled to report changes that go way without permit to the administrative office. A compulsory provision should be set up to have a fire-resistant performance to movable furniture. The classification index designating the fire hazard of interior material by flame spread rate and smoke toxicity and its test method should be established.

  • PDF

A Study on Using the Interior Finishing Material using Regulation at Multiple-using Businesses (다중이용업소 실내마감재료 사용기준에 관한 연구)

  • Kim, Yong-Sung;Cho, Sung-O
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.5
    • /
    • pp.216-224
    • /
    • 2013
  • There are the relevant provisions that apply to building regulations about the Building codes, Fire Protection laws, and more Multi-using interior finish materials businesses etc. The differences between these regulations are as follows: The Building codes is defined the main use of the building according to facilities to used to set the scale by the use of the floor space, On the other hand, Fire Protection laws are the basic purpose and the act of using the architectural space(or sales) by separating object by fire. And Multiple-using Businesses Facilities consist of two regulations engaged in the kind of law and the size of the floor area. One building can not be based on operating facilities and together in Multiple use businesses Law. As such, the Buildings are applied to the Building codes, Fire Protection laws, such as Multi-using Businesses Facilities interior construction industry due to the structural differences in the position of the designer feeling a lot of difficulties and confusion. The Multi-use businesses Facilities engage in the kind of law, the size of the floor area and seating capacity. These can not be based on operating facilities, and consists of two regulations together in one building. This study is purposed to help improving the finish of the interior architecture that is related to the Building code regulations, Fire Protection laws, Multi-using Facilities interior finishing material relevant with the provisions from the law through analyze the case of developed countries, and the current Multiple use Businesses Facilities research range from the law of multiple-using facilities, interior finishing, interior architecture for supervision reasonably and compensation for the interior design. So, Result is as follows: First, interior decorations can be separated the fixed material and the moveable things. second, It should be included multi-using Business though small size business space at the basement floor. third, It should be established statute law that design and construction responsibility. forth, re-testing fire resist performance after some period. and finally, it need to mitigate regulation where be installed sprinkler.

A Case Study on Determination of Fire Causes for SAUNA FACILITY Fires Validate by CFD Fire & Smoke Simulation Modeling Method (화재시뮬레이션 S/W를 이용한 연소예측모델링기법에 의한 국내 사우나 시설의 화재원인규명을 위한 사례연구)

  • 박형주;신동철
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.358-374
    • /
    • 2002
  • 최근 빈번하게 발생하고 있는 사우나 등의 열을 방사하는 도크내에서 발생하는 화재사고는 다중이용업소를 이용하는 불특정한 사람들의 생명을 위협하고 있는 수준에 도달하고 있다. 특히 이런 시설의 화재는 화재발생 후에 소방대에 의한 진압에만 치중하고 있어 향후 계속하여 화재가 발생할 우려가 큼에도 불구하고 착화원인을 규명하는데 소홀히 하고있다. 특히 현장감식에 의한 육안조사만을 실시하여 화재원인을 추정하거나 설정하는 경우가 대부분이라 근본적인 대책을 세우지 못하고 있다. 따라서 본 연구에서는 육안조사 등에 의하여 설정한 착화원인을 과학적인 분석법 즉, EU국가에서 널리 사용하는 CFD(컴퓨터수치해석)시뮬레이션 S/W를 사용하여 연소모델링에 의한 검증조사기법을 적용하여 원인을 검증하는데 사용하여 국내화재조사기술의 과학화를 시도하였다.

  • PDF

Analysis of Evacuation Time According to Variation of Evacuation Stairs' Width in Large-Scale Goshiwons (대규모 고시원의 피난계단 폭의 변화에 따른 피난소요시간 분석)

  • Oh, Su-cheol;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.5
    • /
    • pp.641-651
    • /
    • 2022
  • This research compares and analyzes evacuation time depending on the change in stair width in case of fire at Goshiwons. For this, a simulation has been conducted based on possible evacuation time according to the calculation method for the number of people admittable to a specific target for fire fighting equipped with accommodation. Currently, Gosiwon, which is classified as an accommodation facility (a total floor area of 500 m2 or more), uses blind spots prescribed by the Fire Services Act, Building Act, and Parking Act to build a high-rise building on a small area of land, and most Gosiwon is transformed into a modified accommodation. This is in line with the owner's operating profit, so it is expected to show a continuous increase. Securing the golden time of Gosiwon evacuation time is the last bastion of Gosiwon residents who belong to the economically disadvantaged in our society, and we hope this study will serve as a starting point for discussions on revising related laws and regulations to establish a social safety net As a result of the evacuation simulation analysis, the evacuation time was the least when the width of the group and the evacuation stairs were expanded to 200cm, and the evacuation time of the existing building was reduced by up to 166.3 seconds by comparing 648.4 seconds and scenario 6. This analysis can be meaningful, in that the width of the evacuation stairs revision of related laws and regulations for the safety of multiplex available premises.

A Study on Analysis of Installation on the Actual State and Improvement about a Descending Life Line (완강기의 설치 실태 분석 및 개선에 관한 연구)

  • Choi, Yong-Hyuk;Park, Sung-Jin;Kim, Tae-Gu;Kim, Kwang-Il
    • Fire Science and Engineering
    • /
    • v.22 no.1
    • /
    • pp.105-114
    • /
    • 2008
  • This study investigated problems found with the installation of a descending life line which is one of the compulsory fire escape apparatuses required by the revised "Fire Service Act" of 2006 for multi-use facilities and multistory buildings. It presents an analysis of the causes and improvement details for the problems classified by type of item. To achieve the purpose, the total 367 problem points are indicated. The problems of Installation are unsuitable window glass using the descending life line(34%), required passage device is not attached(23.7%), the installation location is with required operation(20%) and damaged descending life line(20%) were investigated. In particular, the study looks at the stress analysis range for cracking window glass which is required for people to escape in an emergency. People have questioned unsuitable window glass for using the descending life line among the problems with the installation. As a result of stress analysis, window glass thickness of the place where the descending life line is installed must be 3 or 6 mm. In addition, this study indicates substantial improvement measures for installing the descending life line so I will actually be used as a fire escape apparatus to protect human lives, and not just to formally meet the Fire Service Act.