• Title/Summary/Keyword: 다발

Search Result 1,885, Processing Time 0.023 seconds

Prediction of the Friction Factor forTurbulent Flow in a Rod Bundle Using Law of the Wall (벽면의 법칙(Law of the Wall)을 이용한 봉다발의 난류마찰계수 예측)

  • 김내현;전태현;이상근;김시환
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.8
    • /
    • pp.1545-1551
    • /
    • 1992
  • This work is concerned with the prediction of turbulent friction factors in rod bundles. In this study, the Law of the Wall is assumed to be valid over the entire flow area. The flow channel is divided into element channels, and the algebraic form of the "Law of the Wall" is integrated over each element channel to yield an analytic expression for the pressure drop in the rod bundle. The method is applied to rod bundles with 1.2

Numerical Analysis of Turbulent Flow around Tube Bundle by Applying CFD Best Practice Guideline (CFD 우수사례 지침을 적용한 관 다발 주위의 난류유동 수치해석)

  • Lee, Gong Hee;Bang, Young Seok;Woo, Sweng Woong;Cheng, Ae Ju
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.10
    • /
    • pp.961-969
    • /
    • 2013
  • In this study, the numerical analysis of a turbulent flow around both a staggered and an inline tube bundle was conducted using ANSYS CFX V.13, a commercial CFD software. The flow was assumed to be steady, incompressible, and isothermal. According to the CFD Best Practice Guideline, the sensitivity study for grid size, accuracy of the discretization scheme for convection term, and turbulence model was conducted, and its result was compared with the experimental data to estimate the applicability of the CFD Best Practice Guideline. It was concluded that the CFD Best Practice Guideline did not always guarantee an improvement in the prediction performance of the commercial CFD software in the field of tube bundle flow.

Single Bundle PCL Reconstruction with Remnant Preservation (잔여 조직을 보존한 단일 다발 후방십자인대 보강재건술)

  • Lee, Dong Chul;Kim, Won-Ho
    • Journal of the Korean Arthroscopy Society
    • /
    • v.15 no.2
    • /
    • pp.125-131
    • /
    • 2011
  • Optimal treatment of the torn posterior cruciate ligament (PCL) remains controversial. The type of tibial fixation (transtibial vs inlay), the femoral tunnel position within the femoral footprint (central, eccentric or isometric), and the number of bundles in the reconstruction (single-bundle vs double-bundle) are controversial issues. The PCL has a better chance of spontaneously healing than the anterior cruciate ligament (ACL) because of a rich blood supply (near the branch of the middle genicular artery) and coverage with a thicker synovium. In general, for easier passage of the graft and full visualization of the original ligament attachment site during the precise positioning of the tunnel, the remaining PCL fibers are usually debrided during reconstruction. However, the remaining remnant structures would significantly contribute to the posterior stability of the knee joint, the healing of the graft, preserving proprioceptive function of the mechanoreceptors in the PCL. Double bundle PCL reconstruction may result in some surgical complications because of increased complexity of making tunnel. Therefore, single bundle PCL reconstruction with remnant preservation seems to be an effective procedure.

  • PDF

Measurements of Turbulent Flow In a$6\times{6}$ Rod Bundle with Spacer Grids (지지격자를 갖는 $6\times{6}$ 봉다발에서의 난류유동 측정)

  • Yang, Sun-Kyu;Chung, Moon-Ki
    • Nuclear Engineering and Technology
    • /
    • v.28 no.2
    • /
    • pp.162-174
    • /
    • 1996
  • The local hydraulic characteristics in a single phase flow of a 6$\times$6 rod bundle with neighboring different spacer grids were measured by using a LDV(Laser Doppler Velocimeter) system. 6$\times$6 rod bundle is formed by two 3$\times$6 rod bundles with different spacer grids. The objective of this study in a rod bundle is to investigate the thermal-hydraulic interactions between different spacer grids with different configurations and resistance. By using a LDV system, the velocity and turbulent intensity in axial and horizontal directions ore measured. Pressure drop measurements ore also performed to evaluate the loss coefficient for the spacer grid and the friction factor for rod bundles. Implications concerning thermal mining due to spacer grids were investigated based on the hydraulic test results. Swirl factor, which is assumed as a qualitative criteria for DNB(departure from nucleate boiling), was defined and estimated from the horizontal velocity result.

  • PDF

Multiple Schwannomas in the Peripheral Nerve - 3 Cases Report - (말초신경에 생긴 다발성 신경초종 - 증례 보고 3예 -)

  • Kang, Ho-Jung;Lee, Dae-Young;Yoon, Hong-Kee;Hahn, Soo-Bong;Park, Chan-Il;Yang, Seok-Woo
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.11 no.1
    • /
    • pp.105-109
    • /
    • 2005
  • This journal reports three cases diagnosed with schwannomatosis in which no clinical symptoms of type 2 neurofibromatosis. The chief complain was pain. In adolescence and adult group, all masses were found. The locations were brachial plexus, popliteal fossa and hand. No hearing impairment, vertigo, tinnitus and visual disturbance was observed in any of the case. Family history was negative. In all cases, there was no evidence of vestibular schwannoma on cranial MRI imaging study. In all cases, Tinel sign was positive. Pathologic diagnosis was positive for schwannoma. Further study and case collection is needed to idenity the clinical manifestation, clinical course and genetic characteristic of schwannomatosis.

  • PDF

Congenital Polyvalvular Disease; Report of A Case (선천성 다발성 판막질환 1예 보고)

  • 김정원;민경석;윤태진;서동만;윤소영;김영휘;고재곤;박인숙;김규래
    • Journal of Chest Surgery
    • /
    • v.34 no.8
    • /
    • pp.626-629
    • /
    • 2001
  • Congenital polyvalvular disease is a connective tissue disorder affecting more than one heart valve with variable involvement of the entire valvular and subvalvular apparatus. It is frequently associated with the Trisomy 18 and trisomy 13-15 or ventricular septal defect and patent ductus arteriosus. We present an isolated case of congenital polyvalvular disease in a new born baby with a review of the pertinent literatures, which has not been described in Korea. The mass was discovered as a right atrial mass in the prenatal ultrasonography and it was thought to be either a hematoma or a myxoma in the preoperative echocardiography. Microscopic examination of the surgically resected mass showed irregular thickening, nodulation, and additional features of calcification and ossification in the valvular connective tissue on the body of anterior and septal leaflet of tricuspid valve. Congenital polyvalvular disease should be included in the differential diagnosis in cases showing valvular calcification or ossification in the fetal echocardiography.

  • PDF

Giant Cell Tumor of Tendon Sheath in Hand (Comparative Studies Between Single and Multifocal Lesions) (수부 건초에서 발생한 거대 세포종 (단발성 및 다발성 거대 세포종의 비교))

  • Rhee, Seung-Koo;Kang, Yong-Koo;Bahk, Won-Jong;Yang, Sung-Chul;Shin, Yun-Hack
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.9 no.1
    • /
    • pp.52-60
    • /
    • 2003
  • Purpose: To analyse their end results and also to differentiate the single or multiple giant cell tumor(GCT) of tendon sheath in hand. Materials & Methods: Total 21 cases with GCT of tendon sheath in hand were treated surgically and analyzed their end results with clinically, radiologically and pathologically to allowed for average 16 months after surgical excision. Results: The finger flexor tendons, especially on index and ring finger, involving distal interphalangeal joint and mid-phalanges in fourth decades (average age of 47 years old) were frequently involved, and the mass was not exceed than 2 cm in size, fixed on tendon sheath with rubbery hard tenderness but rare bony involvements except 4 cases of bony erosion and cortical perforation. The three cases with multiple GCT of hand was also combined with familial hypercholesterolemia, and are commonly involved the extensor tendons as well as achilles tendons bilaterally, treated with partial excision because of multiplicity. Average 16 months after surgical excision for single GCT cases was followed and showed the recurrence in 3 cases(3/18,16.7%), treated with wide excision. The single and multifocal GCT are similar in pathologic changes but different soft tissue tumors in their pathogenesis, treatment and prognosis. Conclusion: Incomplete excision of GCT of tendon sheath in hand are thought to be the cause of recurrence, especially in cases with incomplete lesional excision, in multilobular and bony involvement etc. So careful wide excision is necessary to prevent the recurrence.

  • PDF

고밀집 섬유집합체에 의해 유도된 모세관현상을 이용한 순환식 수은전극 전해계의 개발과 그 특성 연구

  • 김광욱;변기호;이일희;유재형;박현수
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05c
    • /
    • pp.565-570
    • /
    • 1996
  • 본 연구에서는 고밀집 섬유다발체 내에 수은과 금속이온을 함유한 수용액을 동시에 주입시켜 최소 공간에서 최대한의 수은전극 면적을 갖는 수직형 순환식 수은 모세관 다발체 전극 전해반응 장치가 개발되었다. 이장치의 특성과 안정성을 평가하기 위해 수은과 수용액의 유량 변화에 따른 철(III)과 우라늄(IV)이온의 환원 voltammogram 이 측정되었다. 본 연구에서 개발된 수직형 순환식 수은 모세관 다발체 전극 전해계는 정확히 제어되는 수용액 유량조건에서 수용액내의 금속이온의 산화수 상태 및 농도의 연속적인 분석 및 전해반응 기구 해석에 효과적으로 사용될 수 있음을 알 수 있었다.

  • PDF

A Study of Reflood Heat Transfer in Electrically-Heated Fuel Rod Bundle (電氣加熱式 模擬燃料棒 다발에서의 再冠水 熱傳達 硏究)

  • 정문기;박종석;이영환
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.1
    • /
    • pp.7-14
    • /
    • 1986
  • To predict the fuel clad temperature during the reflooding phase of a LOCA, one may need a knowledge of reflood heat tranfer mechanism in a rod bundle. For this purpose reflooding experiments have been carried out with an electrically heated 3*3 rod bundle. Using the method for the determination of local heat transfer coefficient from the measured wall temperature the parametric effects of coolant flow rate, initial wall temperature, coolant subcooling and heat generation rate on the propagation of rewetting front were investigated. Prediction of the wall temperature histories for these experiments was discussed using REFLUX code with modification of the rewetting temperature correlation. Through this modification, better agreement between experiment and prediction was obtained.

Application of the "Law of the Wall" to Predict the Heat Transfer for Turbulent flow in a Rod Bundle (봉다발의 열전달 예측을 위한 "벽면의 법칙(Law of the Wall)" 적용)

  • 김내현
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.11
    • /
    • pp.2111-2118
    • /
    • 1992
  • In this study, an analytic model is developed to predict Nusselt numbers for turbulent flow in a rod bundle. Flow channel area is divided into several element channels, and simple algebraic equations of universal velocity and temperature profiles are integrated over each element channel. The integral equations are then added to yield an analytic expression for the nusselt number of a rod bundle. The analytic model reasonably predicts the available heat transfer data.