This study is to research the differences of tear film for young people in of a day in a restricted indoor space. The subjects are 58 eyes volunteers for twice preliminary inspection and tear test of a day. 58 healthy individuals with no eye disease, no body disease, orthophoria, corrective visual acuity more than 0.8, binocular spherical equivalence difference over 0.50 diopter, the flattest corneal curvature in horizontal meridian and the steepest corneal curvature in vertical meridian were tested. The uncorrective visual acuity, refractive error, corneal curvature, schirmer test and tear break up test were performed in the morning and afternoon. Schirmer test were $16.0{\pm}7.0mm$ in the morning and $14.1{\pm}7.1mm$ in the afternoon. TBUT were $11.3{\pm}0.6$ sec in the morning and $12.1{\pm}0.9$ sec in the afternoon. They have no significant differences.
This study is to research the tear film stability for 48 eyes, agreed the purpose of study, didn't have no contact lens wearing and were tested all two times in a day. Their visual acuity was more than 0.8, corrective visual acuity more than 0.8, the fattest K-reading, apical corneal radius, was in 7.40~8.40mm, corneal astigment was less than 1.00D and orthophoria. The tests, tear scope test, tear film break up time test(TBUT) and schirmer test order, were performed their functions before and after their working at interval of 6 hours over. The tearscope test results was no difference, TBUT was no difference, although 1.2 seconds more in the afternoon, shcirmer test was decreased 2.0mm in the afternoon.
Purpose: To study the effect of hyaluronic acid(HA), which was widely used in artificial tears, multi-purpose solution(MPS), cosmetics, and drug acting on the musculo-skeletal system, in wettability and comfort of contact lens, we compared HA including lens(+HA) with HA excluding lens(-HA) by clinical evaluation. Methods: During four weeks, the selected 28 university student volunteers who did not have any eye disease wore +HA contact lens on their right eyes, and -HA contact lens on their left eyes, and then compared right eyes to left eyes as control. After prescribing by spherical equivalent calculation, over-refraction by auto-refractometer, and contact lens wearing for two weeks and four weeks, tear evaluation, the anterior of eyes examination, fitting convenience evaluation, surface wetting test, surveys were checked up. Results: Compared with the control group (-HA contact lens), +HA contact lens provided better wetting properties. The amount of released tear in -HA contact lens group became less in four weeks than before, but that in +HA contact lens group showed no significant difference from the initial one. In terms of the redness in eye, there was no significant difference between +HA and -HA contact lens groups. Fitting of +HA contact lens on eye was much easier than the control, -HA contact lens. From the results of survey, comfort, wettability, ease of cleaning, and dryness of eye in +HA contact lens group were generally better than those of -HA group, but redness and contact lens handling showed little difference. Conclusions: The addition of HA in soft contact lens(+HA) may enhance the wettability of lens during lens wearing, resulted in the better comfortable wearing of lens eventually.
Gil, Tae Young;Bae, Gi Hyun;Kwag, Joo Young;Hyun, Joo;Choi, Jin Seok;Pak, Kyu Hong;Chung, Sung Kun
Journal of The Korean Ophthalmological Society
/
v.59
no.12
/
pp.1103-1107
/
2018
Purpose: To evaluate the clinical effect of intense regulated pulse light (IRPL) and changes in tear film thickness in dry eye patients. Methods: A retrospective study was conducted on 25 patients with Meibomian gland dysfunction who had subjective dry eye discomfort and whose tear film break-up time (TBUT) was < 10 seconds. All patients were treated with IRPL three times on days 1, 15, and 45. TBUT, Schirmer 1 test results, cornea staining score with fluorescein, ocular surface disease index (OSDI), and lipid layer thickness were measured and compared before and after the procedure. Results: TBUT was significantly increased from $3.7{\pm}1.2s$ to $4.4{\pm}2.1s$ after IRPL (p = 0.03). Schirmer 1 test and cornea staining scores changed significantly (p < 0.01 and p = 0.01, respectively). OSDI also showed a statistically significant improvement from $39.5{\pm}17.5points$ to $30.4{\pm}18.7points$ (p = 0.01). However, no significant difference in lipid layer thickness was observed (p = 0.49). Conclusions: IRPL is an effective treatment modality to improve TBUT, Schirmer 1 test scores, cornea staining scores, and subjective dry eye symptoms.
Park, Jwa-Woo;Lee, Bum-Hee;Park, Seung-Hwan;Park, Su-Young;Jung, Chan-Wook;Ryu, Hyung-Gi;Kim, Ho-Shin
The Korean Journal of Nuclear Medicine Technology
/
v.18
no.1
/
pp.76-81
/
2014
Purpose: Diversity and the lachrymal duct deformities and the passage inside the nasal cavity except for anterior image such as epiphora happens during the test were able to express more precisely during the dacryoscintigraphy. Also, we thought about the necessity of a method to classify the passage into the naso-lachrymal duct from epiphora. Therefore, we are to find the validity of the method to obtain both oblique views except for anterior views. Materials and Methods: The targets of this research are 78 patients with epiphora due to the blockage at the lachrymal duct from January 2013 to August 2013. Average age was $56.96{\pm}13.36$. By using a micropipette, we dropped 1-2 drops of $^{99m}TcO4^-$ of 3.7 MBq (0.1 mCi) with $10{\mu}L$ of each drop into the inferior conjunctival fold, then we performed dynamic check for 20 minutes with 20 frames of each minute. In case of we checked the passage from both eyes to nasal cavity immediately after the dynamic check, we obtained oblique view immediately. If we didn't see the passage in either side of the orbit, we obtained oblique views of the orbit after checking the frontal film in 40 minutes. The instrument we used was Pin-hole Collimator with Gamma Camera(Siemens Orbiter, Hoffman Estates, IL, USA). Results: Among the 78 patients with dacryoscintigraphy, 35 patients were confirmed with passage into the nasal cavity from the anterior view. Among those 35 patients, 15 patients were confirmed with passage into the nasal cavity on both eyes, and it was able to observe better passage patterns through oblique view with a result of 8 on both eyes, 2 on left eye, and 1 on right eye. 20 patients had passage in left eye or right eye, among those patients 10 patients showed clear passage compared to the anterior view. 13 patients had possible passage, and 30 patients had no proof of motion of the tracer. To sum up, 21 patients (60%) among 35 patients showed clear pattern of passage with additional oblique views compared to anterior view. People responded obtaining oblique views though 5 points scale about the utility of passage identification helps make diagnoses the passage, passage delayed, and blockage of naso-lachrymal duct by showing the well-seen portions from anterior view. Also, when classifying passage to naso-lachrymal duct and flow to the skin, oblique views has higher chance of classification in case of epiphora (anterior:$4.14{\pm}0.3$, oblique:$4.55{\pm}0.4$). Conclusion: It is considered that if you obtain oblique views of the bilateral orbits in addition to anterior view during the dacryoscintigraphy, the ability of diagnose for reading will become higher because you will be able to see the areas that you could not observe from the anterior view so that you can see if it emitted after the naso-lachrymal duct and the flow of epiphora on the skin.
The Journal of the Convergence on Culture Technology
/
v.5
no.4
/
pp.355-359
/
2019
Schirmer test is one of the most used methods for the diagnosis of dry eye. We attempted to develop a tear level measurement tool to replace unreliable Schirmer test with inaccurate results. Absorbency tests for various absorbents were carried out. As a result, ${\alpha}$ cellulose pulp was selected as the absorbent. Prototypes were produced and evaluated twice. Finally a tear level measurement tool in the form of a strip of ${\alpha}$ cellulose pulp adhered to a polyurethane was prepared. Usability evaluation of prepared tear level measurement tool was performed. As a result, it was confirmed that it has a significant correlation with SM tube developed oversea recently. In addition, it was judged to be useful as an alternative to the Schirmer test in terms of measurement time and accuracy.
Purpose: To understand symptoms and signs in soft contact lens wearers the authors evaluate the attribution of the tear test to the contact lens related symptoms and signs. Methods: Sixty-two healthy soft contact lens wearers (23.95${\pm}$4.38 years old, 18.60${\pm}$16.92 months of prior lens wear) were participated in this study. 3 kinds of tear test and McMonnies' questionnaire test were performed for the soft contact lens wearers and subjective symptoms and objective signs were graded using CCLRU scales during the study period. Results: In this surveys, we found ocular dryness, redness and tiredness are the most common frequent and severe symptoms in soft contact lens wearers. Frequency of the ocular dryness, redness and tiredness are associated with grittiness, burning sensation and foreign body sensation respectively, and severity of the photophobia, foreign body sensation are associated with unstable vision and grittiness and which are associated with score of McMonnies' Questionnaire. Conjunctival redness and limbal redness are major signs but those are not need to be clinical care and rarely occurred corneal and conjunctival staining which are associated with tear break-up-time statistically. Conclusions: Dryness, redness and tiredness are primary common symptoms in Korean soft contact lens wearers. The frequency of those symptoms are increased with the period of soft contact lens wear and those are associated with other symptoms but have no relationship with signs.
Purpose: To investigate the clinical manifestation of nasolacrimal duct obstruction after radioactive iodine therapy for thyroid cancer. Methods: The authors examined 622 patients who were treated with radioactive iodine therapy after the operation for thyroid cancer from January 2009 to December 2011. Fourteen patients (18 eyes) were diagnosed nasolacrimal duct obstruction based on the lacrimal irrigation test, lacrimal probing test and dacryocystography in our oculoplastic clinic. We analyzed the dose of radioactive iodine therapy, number of treatments, clinical manifestation and treatment type by retrospectively reviewing the patients' medical records. Results: The mean radioactive iodine dose ($215.7{\pm}23.1mCi$, p = 0.01) and the mean number of treatments ($1.36{\pm}0.50$, p < 0.001) were significantly greater in 14 patients who had nasolacrimal duct obstruction than in patients who did not. The average onset of tearing symptoms occurred 10.2 months after radioactive iodine therapy. The mean time between correct diagnosis and therapy was 18.4 months. Three patients (3 eyes) had occlusion at the common cannaliculus and 11 patients (15 eyes) had occlusion at the nasolacrimal duct. Ten patients (13 eyes) underwent endonasal dacryocystorhinostomy for complete obstruction and 4 patients (5 eyes) underwent silicone tube intubation for partial obstruction. Conclusions: Nasolacrimal duct obstruction is a rare complication associated with radioactive iodine therapy for thyroid cancer, thus, clinicians should be aware of this complication and refer patients with symptoms of epiphora to the oculoplastic department for specialized evaluation and treatment.
Purpose: To evaluate the changes of OSI value according to tear-film instability measured serially by OQAS(Optical Quality Analysis System, Visiometrics, Spain) every seconds. The presented study analyzed the relationship of the OQAS parameter with the results of the tear-film break-up time, Schirmer test, and the McMonies score. Methods: 147 eyes of 82 subjects were randomly selected from university students (age: $21.51{\pm}3.97$, male 45, female 37). Subjects were measured tear-film break-up time, Schirmer test, McMonies score and once every second for 15 seconds after blinking by continuous measurements from OQAS system. Results: The normal eye groups presented OSI values of $2.13{\pm}1.16$ while the dry eye groups had OSI values of $3.76{\pm}1.42$. Therefore, a significant difference between the normal eye group and dry eye group was discovered (p<0.05). In addition, the OSI value of all subjects increased over time. The OSI value, which was measured every second after blinking occurred, significantly increased between 6 seconds and 7 seconds after the start of the measurement (p<0.05). OSI cut off of 30% (sec.) showed a greater correlation; TBUT (r = 0.855, p = 0.000), McMonies test (r = -0.351, p = 0.003), Schirmer (r = 0.316, p = 0.012). Conclusions: Continuous measurement of OQAS showed a high correlation with the value of the existing dry eye tests. Therefore, Analysis of OSI values by utilization of OQAS could be useful in objectively evaluation of tear film in patients.
Purpose: The study was performed to compare the difference of non-invasive tear break-up time (NIBUT) with alignment or steep fitting of soft contact lens in normal and dry eyes. Methods: Total 40 eyes (aged 20~30 years) were classified to the normal (n=20) or dry eye group (n=20) by the diagnosis methods for dry eyes and worn soft contact lens (polymacon material) with alignment or steep fitting. NIBUTs of lens wearers were separately measured at the points of before wearing, immediately after wearing and after stabilization of tear film. Results: With alignment fitting, averaged NIBUT in the dry eye group after stabilization of tear film was not significantly different from that of the normal eye group. However, averaged NIBUTs in the normal and dry eyes had significant difference when measured immediately after lens wearing. However, the number of eyes having NIBUT less than 4.0 second was 30% higher compared to the number of normal eyes with steep fitting when measured immediately after wearing. Some shorten NIBUT in dry eyes with steep fitting was also shown after stabilization of tear film. Conclusions: These results suggest that wearing soft contact lens in dry eyes differently affect tear film compared to normal eyes. Thus, dry eyes need more advertent fitting for contact lens wearing because of unstable tear film.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.