• Title/Summary/Keyword: 누출 위험도

Search Result 369, Processing Time 0.034 seconds

Analysis of Threat Agent for Important Information Systems (중요 정보시스템 위협원에 대한 분석)

  • Kim, Tai-Hoon;Kim, Seok-Soo;Park, Gil-Cheol
    • Journal of Advanced Navigation Technology
    • /
    • v.11 no.2
    • /
    • pp.203-208
    • /
    • 2007
  • Because the networks and systems become more complex, the implementation of the security countermeasures for important Information Systems becomes more critical consideration. The designers and developers of the security policy should recognize the importance of building security countermeasures by using both technical and non-technical methods, such as personnel and operational facts. Security countermeasures may be made for formulating an effective overall security solution to address threats at all layers of the information infrastructure. But all these works can be done after assuming who is the threat agent. In this paper we identify the treat agents for information systems, summarize the characteristics of threat agents, and apply weighting factors to them.

  • PDF

A Case of Balloon Kyphoplasty in High Risk under Cement Leakage -A case report- (시멘트 누출 위험성이 높은 환자에서의 풍선 척추몸통뼈 복원술 -증례보고-)

  • Choi, Yun Suk;Lee, Mi Geum;Lee, Hyo Min;Jo, Ji Yon;Jeong, Hee Jin;Lee, Chul Joong;Lee, Sang Chul;Kim, Yong Chul;Sim, Sung Eun
    • The Korean Journal of Pain
    • /
    • v.19 no.2
    • /
    • pp.261-265
    • /
    • 2006
  • A vertebral compression fracture can cause chronic back pain, and may also result in progressive kyphosis. The traditional treatments of a vertebral compression fracture include bed rest, analgesics and bracing. Balloon kyphoplasty can restore the vertebral height and allow safe bone cement injection into the cavity made by the balloon, which significantly reduces the risk of cement leakage compared to vertebroplasty. An 82-year-old female patient suffered from severe low back pain. Due to the intractable pain and immobility, which could not be relieved by conventional care, as well as the empty vertebral body associated with communicated fractures of the vertebral surfaces, balloon kyphoplasty, with a thicker bone cement injection than usual with balloon kyphoplasty, was chosen. The preoperative intractable pain and immobility were dramatically relieved soon after the procedure, without any complications.

Implementation of a WIPI-based Intelligent Home Service Robot (WIPI 기반의 지능형 홈서비스 로봇의 구현)

  • Kim, Jin-Hwan;Shin, Dong-Suk
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.5
    • /
    • pp.19-28
    • /
    • 2008
  • In this paper, we implemented an intelligent home service robot system which alerts users to danger by wireless internet platforms for interoperability(WIPI) of a cellular phone. This paper discusses the three parts of the system: robot, middleware and mobile system. First, the robot consists of a gas sensor, a fire detector, ultrasonic sensors, motors, a camera and a Bluetooth module. The robot perceives various danger circumstances. Second, the middleware connects the robot and the mobile system. It monitors the robot and sends emergency notification SMS message to the user's cellular phone if in danger. Third, the mobile system sends commands which control the robot using TCP/IP protocol. The proposed scheme is to control the sensors of the robot part through Atmega 128 processor, and the robot and middleware parts will be installed in the household, and will be controled by mobile part from the outside.

Study on the Decommissioning of Small Nuclear Facility through Analyzing Foreign Decommissioning Practices (국외 해체 사례 분석을 통한 국내 소규모 방사선이용시설 해체에 관한 연구)

  • Kwon, Dayeong;Kim, Yongmin
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.3
    • /
    • pp.125-130
    • /
    • 2015
  • RI & RG are used in various field such as medical field, industrial field, agricultural and food&life field. The number of small nuclear facilities is on the increase. We need to take an interest in decommissioning of small nuclear facility and predict the occurring problem from facility decommissioning. Because of the relatively low radiation risk, the preparation of the small nuclear facility dismantling is often neglected. As the accident in Goiania, Brazil showed, the impact of the decommissioning of small nuclear facilities is not less than the large nuclear facilities although it may seem dangerless. Therefore, we analyzed the each institutional characteristics of the decommissioning of small nuclear facilities through foreign case study on this research. Also, we proposed several considerations on decommissioning such as reuse of facility and source, lack of space, stakeholder involvement and failures of protection. Through these study, we tried to make guideline of the small nuclear facilities decommissioning.

Iris Recognition using Gabor Wavelet and Fuzzy LDA Method (가버 웨이블릿과 퍼지 선형 판별분석 기법을 이용한 홍채 인식)

  • Go Hyoun-Joo;Kwon Mann-Jun;Chun Myung-Geun
    • Journal of KIISE:Software and Applications
    • /
    • v.32 no.11
    • /
    • pp.1147-1155
    • /
    • 2005
  • This paper deals with Iris recognition as one of biometric techniques which is applied to identify a person using his/her behavior or congenital characteristics. The Iris of a human eye has a texture that is unique and time invariant for each individual. First, we obtain the feature vector from the 2D Iris pattern having a property of size invariant and using the fuzzy LDA which is further through four types of 2D Gabor wavelet. At the recognition process, we compute the similarity measure based on the correlation values. Here, since we use four different matching values obtained from four different directional Gabor wavelet and select the maximum value, it is possible to minimize the recognition error rate. To show the usefulness of the proposed algorithm, we applied it to a biometric database consisting of 300 Iris Patterns extracted from 50 subjects and finally got more higher than $90\%$ recognition rate.

A Study on Total Hazard Level Algorithm Development for Hazardous Chemical Substances (유해화학물질의 종합위해등급 알고리즘 개발에 관한 연구)

  • 고재선;김광일;정상태
    • Fire Science and Engineering
    • /
    • v.14 no.4
    • /
    • pp.7-16
    • /
    • 2000
  • In the study, three criteria(toxicity, fire & explosion, environment) and damage prediction method for each case was set up, and all these criteria were applied to the subject substance that was selected as hazardous level by integrating all criteria through Algorithm. Particularly, the environment criterion is a comprehensive concept, environment index modeling by combining USCG(United State Coast Guard) & MSDS(Material Safety Data Sheet) environment criteria classifications and the environment part of MFPA's health hazardousnes(Nh). And for damage prediction method of each criterion were adopted and they were applied to hazardous chemical substances in use or stored by chemical substance related enterprises located in each region that made possible to set up total hazard level of used substances(inflammability, poisonousness and counteraction on a unit substance, and hazard level & display modeling on environment) & damage prediction in case of accident & solidity setup(CPQRA: Chemical Process Quantitative Risk Assessment, IAEA: International Atomic Energy Agency, VZ eq: Vulnerable Zone) risk counter. Thus it is deemed that it can be applied to toxic substance leakage that can happen during any chemical processing & storage, application as a tool for prior safety evaluation through potential dangerousness computation of fire & explosion.

  • PDF

A Study on Proposals for Improving the Fire Protection Regulations for Nuclear Power Plants (원자력발전소 화재방호 규제 개선 방향에 관한 연구)

  • Ma, Jin-Soo;Kwon, Kyung-Ok
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.116-122
    • /
    • 2010
  • The fire protection system of nuclear power plants shall be designed, constructed and operated, through a defense-in depth criterion to suppress the leakage of radioactivity to the outside and to allow the safety shutdown function when a fire occurs. In order to achieve these purposes, most of countries abroad operating the nuclear power plants keep up the integrated regulations, however we have two guidelines, the fire protection service act and the nuclear energy act, as mandatory requirements to apply to the fire protection systems in nuclear power plants. It has shown that USA, Canada and Japan which have long experience in operating nuclear power plants have regulations integrated technically for fire protection system of nuclear power plants. It is proposed that the things once verified the risk analysis of the fire hazard by the nuclear law in the design for fire suppression system in plants should be authorized by the fire protection service act as an exception.

Situation-specific Task Control System based on Real-time Data Classification (실시간 데이터 분류 기반 상황별 작업 제어 시스템)

  • Song, Hyunok;Kim, Hakjin;Jung, Hoekyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.9
    • /
    • pp.1771-1776
    • /
    • 2017
  • Recently, IoT(Internet of Things) has been utilized in various fields provide a service to users by configuring a smart environment in a particular place. However, since the existing system does not change the operation and the task of the device according to the change of the surrounding environment, the user must operate passively every time the environment and the situation change. In this paper, we propose Situation-specific Task Control System based on real-time data classification. Sensor data is sent to the server and classified into real-time and non-real-time data, and then inserted into the decision tree to identify tasks according to the situation. In addition, the danger situation is divided into two stages, such as gas leakage and fire, and a warning message is sent. Therefore, it is possible to reduce the waste of electric power and the occurrence of malfunction, and it can be expected that the service with increased work efficiency will be provided.

Flammability and Thermal Stabilities of Heat Transfer Oils (열매체유의 인화성과 열안정성)

  • Lee, Keun-Won;Lee, Jung-Suk;Choi, Yi-Rac
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.2
    • /
    • pp.82-87
    • /
    • 2011
  • Heat transfer oils are used in applications such as heating systems of chemical plant, refinery heat exchange systems, gas plant process, injection molding systems, and pulp and paper processing. These oils are extremely stable and resistance to thermal and oxidative degradation. In the event of a spill or accidental release of heat transfer oils, it can be ignite easily when there is an ignition source. This paper discusses the flammability and thermal stabilities of new and used oils. The flammability of the oils are assessed by measuring changes in flash point and auto ignition temperature. The thermal stability of oils are evaluated by the thermal screening unit ($TS^u$) and the differential scanning calorimeter (DSC). From the experimental results, it is suggested to give fire hazard characteristics to safe precautions for the proper use and treatment of heat transfer oils.

Consequence Analysis by Different DME-LPG Mixture Fuels (DME-LPG 혼합연료에 따른 사고결과 피해예측)

  • Park, Dal-Jae;Lee, Young-Soon
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.2
    • /
    • pp.57-62
    • /
    • 2011
  • DME(Dimethyl Ehther) is considered as an attractive fuel in terms of clean, environmentally friendly form of energy, multi-source and multi-purpose. As the physical properties of DME are almost similar to LPG, DME can be mixed with LPG and DME-LPG mixture fuels seem to be employed without major remodeling of the existing LPG supply infrastructure. However, little attention has been given to the effect of different DME-LPG mixture fuels on consequence analysis to adjacent facilities, buildings and etc. In this work, the consequence analysis by different DME-LPG mixture fuels has been done. The results were discussed in terms of release rate, jet fire, vapor cloud explosions, BLEVEs and etc. It was found that the consequences estimated from fire and explosion scenarios assumed were almost similar for both LPG and DME 20 %.