The Change of Soft Contact Lens after Being Exposed to Fundamental Cosmetics (기초화장품에 노출시 나타나는 소프트콘택트렌즈의 변화)

  • Kim, Ja-Ok;Choi, Jin-Sook;Kim, Dae-Su;Park, Mi-Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.2
    • /
    • pp.99-107
    • /
    • 2006
  • The purpose of this study was to investigate the cause of discomfort come from wearing of soft contact lens(SCL) exposed to fundamental cosmetics, After SCLs were smeared with skin lotion, essence lotion or nutritional cream, they were exposed to artificial tear for 7 days, and then changes of the adhered protein amount, the transmission of visible light, the wettability and the base curve were estimated. The amount of protein adhered to SCLs were increased 3 times by being exposed to fundamental cosmetics. Moreover, the transmission of visible light of SCL exposed to both nutritional cream and artificial tear was 92.8%, which was 4.7% lower than SCL exposed only to artificial tear. By being exposed to skin lotion, essence lotion or nutritional cream, the contact angle of SCLs were increased up to $7.1^{\circ}$, $7.0^{\circ}$ or $5.7^{\circ}$ and the base curve of SCLs were decreased to 3.2%, 5.1% or 8.3%, respectively.

  • PDF

The Investigation on Ultrasonic Cleaning of Soft Contact Lenses in Local Optical Shops and the Protein Removal Effect by Lens Containers (안경용 초음파세척기를 이용한 소프트렌즈 세척 실태 조사와 세척용기에 따른 단백질 제거 효과)

  • Koo, Sung Bong;Cho, Seul Bee;Park, Mijung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.31-40
    • /
    • 2011
  • Purpose: This study was performed to investigate the actual state about ultrasonic cleaning of soft contact lenses in local optical shops and evaluate the removal effect of protein deposit on soft contact lenses with different lens containers by ultrasonic cleaner for eyeglasses. Methods: The actual state about ultrasonic cleaning of soft contact lenses was surveyed in total 75 local optical shops in Seoul, Korea. The cleaning efficacy of different lens containers was compared by measuring the protein remained on ocufilcon D contact lenses after washing by an ultrasonic cleaner for eyeglasses. The changes on surfaces and wetting angles of ocufilcon D contact lenses by repeat ultrasonication were further investigated. Results: The main purpose to use ultrasonic cleaners in local optical shops was rapid cleaning. The ultrasonic cleaning efficacy of ocufilcon D contact lenses with glass containers was little higher than it with plastic containers, but was not significantly different. The changes on surfaces and wetting angles of ocufilcon D contact lenses in a plastic lens container by repeat ultrasonication such as 30 and/or 60 times were shown. Conclusions: There was not significant difference in cleaning efficacy between glass and plastic lens containers. However, repeat cleaning with ultrasonic cleaner for eyeglasses would be carefully considered since some significant changes in the parameters of lens surface and wetting angles were detected by repeat ultrasonification even when lens containers were used for ocufilcon D contact lens during ultrasonictions.

The momentary movement of soft contact lens by blinking : The change of movement depending on wearing time (손목에 의한 소프트콘택트렌즈의 순간적인 움직임 : 착용시간의 증가에 따른 움직임의 변화)

  • Park, Sang-Il;Lee, Youn Jin;Lee, Heum-Sook;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.1
    • /
    • pp.1-7
    • /
    • 2007
  • To investigate the momentary movement pattern of soft contact lens(SCL) depending on wearing time, eight types of soft contact lenses were worn by 10 normal subjects and the momentary movements of SCLs were estimated using by high speed camera(FASTCAM ultima 1024). When the momentary movements of SCLs in the cornea between blinkings were compared after 15 min wearing, the vertical movements of all eight SCLs were about 2 times larger than the horizontal movement but the extent of these movement difference was a function of kinds of SCLs. The momentary moving distance of SCL varied from the kinds of SCLs, which A and B lens, daily wear lens, moved significantly larger distance compared with other SCLs. The momentary movements between blinkings decreased significantly after 8hr wear of SCLs. The extents were different when SCLs were compared with each other, which the reduction range of horizontal and vertical movement was 24.6~60.0% and 20.4~94.3%, respectively. The A, B and C lenses which had relatively higher water content showed the larger movement reduction after SCL wear. This results suggest that wearing SCL for some hours decreases the movement of SCl, which can induce the change of tear flow.

  • PDF

The Comparison of Fluorescein Patterns between Spherical RGP Lens and Aspherical RGP Lens by Corneal Type and Astigmatic Degree (각막형상과 난시도에 따른 구면 RGP 렌즈와 비구면 RGP 렌즈의 플루레신 염색 패턴 비교)

  • Park, Eun Hye;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.1
    • /
    • pp.37-45
    • /
    • 2012
  • Purpose: The change of alignment between RGP lens and cornea according to the lens design was investigated by comparing the areas of fluorescein pattern in central and peripheral regions analyzed by astigmatic degree and corneal type when spherical and aspherical RGP lenses fitted in alignment. Methods: The fluorescein patterns of 90 eyes (19-30 years, $25.12{\pm}3.52$) having with-the-rule astigmatism were analyzed after spherical and aspherical RGP lenses fitted in alignment. Then, their fluorescent areas in central and peripheral regions were calculated and compared for the quantitative evaluation. Results: The case showing concordant base curve between spherical and aspherical RGP lenses in alignment fitting was 72% however, the possibility to have same base curves between spherical and aspherical RGP lenses in alignment fitting was to be less in the case of symmetric bowtietyped cornea and high astigmatism. The fluorescent area in peripheral region of aspherical RGP lens in alignment fitting was smaller than it of spherical RGP lens. Peripheral fluorescent areas in both RGP lenses decreased according to the increase of astigmatic degree and peripheral area in symmetric bowtie-typed corea was smaller than round-typed cornea's peripheral area. In the case of same astigmatic degree, peripheral fluorescent area of aspherical RGP lens was smaller in both corneal types. Conclusions: The results above suggest the changing degree in the alignment between RGP lens and cornea can be varied according to lens design, corneal astigmatism and corneal type. Thus, the results obtained from the quantitative analysis of the alignment between lens design and cornea may be used as the basic information about the establishment of guidelines for RGP lens fitting, the development of proper lens design, and different tear volume in partial regions.

Comparison of In Vitro Lipid Deposition and Change of Optical Characteristics on Daily Disposable Lenses (1-day) and 3-days Lenses Over 3 days (3-days lenses와 daily disposable lenses(1-day)의 착용 시간 별 지방 침착량 및 광학적 특성 변화의 비교)

  • Song, Sun Jung;Lee, Su Yeon;Kim, Ki Hong;Chu, Byoung Sun
    • Journal of the Korean Chemical Society
    • /
    • v.64 no.2
    • /
    • pp.67-73
    • /
    • 2020
  • The study aimed to investigate in vitro lipid deposition of oleic acid, oleic acid methyl ester and cholesterol on a daily disposable (1-day lenses) and 3-days lenses over 3 days and changes of optical characteristics is also investigated. Artificial tear solutions were prepared to simulate actual tear compositions. Two types of contact lenses (1-day lenses (Senofilcon A) and 3-days lenses (silicone tripolymer)) were soaked in the artificial tear solutions within an incubator at 37 ℃ with 150 rpm for 8, 16, 24 hours. Lipid deposition (oleic acid, oleic acid methyl ester and cholesterol) were measured using high performance liquid chromatography (HPLC) instrument. In addition, measurements of oxygen transmissibility, light transmittance and observation of lens surface were conducted. The amount of lipid deposition on the 1-day lenses were 127.55 ㎍/lens for Day 1, 302.96 ㎍/lens, for Day 2, and 353.30 ㎍/lens for Day 3. The 3-days lenses were 46.22 ㎍/lens for Day 1, 66.07 ㎍/lens for Day 2, and 67.45 ㎍/lens for Day 3. Oxygen transmissibility were 81×10-9(cm/sec)(ml O2/ml×mmHg)(Baseline) and 48×10-9(cm/sec)(ml O2/ml×mmHg) (Day 3) for the 1-day lenses, it were 13.23×10-9(cm/sec)(ml O2/ml×mmHg)(Baseline) and 9.6×10-9(cm/sec)(ml O2/ml×mmHg) (Day 3) for the 3-days lenses. Transmittance of each lenses were 97.21% (Baseline) and 94.25% (Day 3) for the 1-day lenses, 97.65% (Baseline) and 95.15% (Day 3) for the 3-days lenses. Observation of surface deposition indicated greatest deposition for the 3-days lenses type on Day 3. Lipid deposition for both lens types increased by day and was greater for the 1-day lenses type. Surface deposition appeared to differ as it was greatest for the 3 days lens type, which may suggest other deposits such as protein may be present.

The Difference of the Cleaning and Wettability-maintaining Efficacy of Lens Care Solution to RGP Lens (관리 용품에 따른 RGP 렌즈의 세척효과 및 습윤성 차이)

  • Kim, Myoung-Hea;Park, Mi-Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.1
    • /
    • pp.27-34
    • /
    • 2006
  • We investigated the question whether the efficacy of cleaning tear components on RGP lens and preserving the superior wettability of RGP lens depended on the different type of contact lens care system - RGP lens care solution, SCL care solution, combined solution both for SCL and RGP lens or saline solution. The removal efficacy of the deposited protein was examined by Lowry protein assay and Scanning Electro Microscope(SEM) and residual lipid concentration on RGP lens was determined by High Pressure Liquid Chromatology(HPLC). Wettability was assessed with an equilibrium water-in-air contact angle method. When cared by RGP lens solution, it was demonstrated that 62 percent out of the adhered protein on RGP lens were removed and the removal efficacy of RGP lens solution was not only 4 times than saline solution and the alternative but also higher twice than SCL solution. Contrarily, the SCL solution had the most excellent removal efficacy of the adhered protein on SCL. These results suggest that the cleaning efficacy is thought to be affected by the other factors like the viscosity of care solutions, which mutual contact between RGP lens and care solutions is on the increase due to the viscosity enhancer in RGP lens care solution. RGP lens solution had the greatest removing efficacy to cholesterol and the residual cholesterol concentration was decreased to 50%. It is significant for RGP lens to preserve the superior wettability which means the predictive value for comfortable wearing and it showed that the RGP lens solution offered the most excellent efficacy to maintain the surface wettability. Combined solution both for SCL and RGP lens had weak efficacy of cleaning and maintaining wettability for RGP lens compared to RGP lens care solution.

  • PDF

RGP lens 다목적 용액의 습윤성에 관한 비교 연구

  • Park, Hyeon-Ju;Kim, Jae-Min;Lee, Gi-Yeong
    • 한국생물공학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.428-433
    • /
    • 2003
  • We measured the effect of wettability of six MPSs for RGP(rigid gas permeable) lens. The used MPSs(multipurpose solutions) were OPTI-SOAK(ALCON), SOLO care hard(CIBA Vision), Total care(ALLERGAN), Simplicity(BOSTON), Wetting and Soaking Sol.(Bausch & Lomb) and Aquas-multi(Saehan). These MPSs keeps hydrophilic property of lens surface and increase the effect of cleaning or increase the effect of preservative effect. To compare with the effect of wettability we followed the way of contact angle measurement which was general way to measure wettability and compared lens which was conducted by each MPS made by different companies. As a control, 0.9% NaCl solution and artificial tears were used. The degree of the effect of wettability was decided by contact angle. It is hydrophilic property nearby $0^{\circ}$ of contact angle and it is closed by hydrophobic property as it increases. The results showed that every lens was nearby hydrophilic property within $25\;^{\circ}-36\;^{\circ}$. Also, it was differed by various factors. The surface tension showed various differences between 19.8 and 31.3 mN/m. In the viscosity, MPSs represented the highest viscosity between $4^{\circ}C$ and $20^{\circ}C$. It was much higher than compared with the viscosity of soft lens MPS. This experiment could be used to grasping the interaction between solutions used to MPS and the natural endowments of lens and to considering the relations of different factors effecting the wettability.

  • PDF

Changes of Lens Morphology and TBUT by Dehydration of Soft Contact Lens (소프트콘택트렌즈 건조로 인한 렌즈 형태 및 TBUT의 변화)

  • Park, Mijung;Lee, Yu-Na;Kang, Kyu Eun;Lee, Min Ha
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.2
    • /
    • pp.1-7
    • /
    • 2008
  • Purpose: This study was performed to evaluate the changes of lens morphology and tear stability during wearing soft contact lenses (SCLs) which were kept in drying condition like dry eye or became to be dried due to heedless care. Method: SCLs having different water content, thickness or material were rehydrated after being dehydrated artificially 2 or 4 times, and estimated their diameter and radius. Furthermore, the changes of tear film break-up time (TBUT) during SCL wearing were also measured. Result: Due to the dryness, the diameter of both 70% water content SCL and 59% water content SCL decreased, but the decrement was larger in 59% water content SCL. The more 59% water content SCL was dehydrated, the more its radius changed. However, the radius of 70% water content SCL did not change by 2 times dehydration and increased greatly by 4 times dehydration. The reduction of diameter of -1.00 D SCL was greater than that of -9.00 D SCL. Moreover, the radius of -1.00 D SCL increased depending on the frequency of dehydration but that of -9.00 D SCL did not changed. The diameter and radius changes of lotrafilcon B, silicone hydrogel lens, were less than those of hilafilcon B, copolymer of HEMA and N-vinyl pyrrolidone. TBUT during wearing SCLs decreased by wearing dehydrated SCLs. Conclusion: The diameter and radius of dehydrated SCLs as well as TBUT during wearing them were changed in spite of rehydration, which would be the important cause of uncomfortable feeling when people wore dehydrated SCL. The changes of SCL morphology and TBUT differed according to the water content, lens thickness and material.

  • PDF

Analysis of Evaluation Methods for the Efficacy of Protein Removal Agents for Soft Contact Lens (소프트콘택트렌즈 단백질제거제의 효능 평가법 분석)

  • Byuna, Hyun Young;Sung, Hyung Gyeong;Won, Hye Lim;Shim, Ji In;Park, Mijung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.51-57
    • /
    • 2014
  • Purpose: The present study was conducted to establish the experimental condition for the proper evaluation of protein removal efficacy when developing protein removal agents. Its protein removal efficacy was further analyzed and compared with the result from protein removal efficacy against protein deposition on contact lens to suggest the evaluation method for efficacy of protein removal agents. Methods: Protein digestibility assay presented in the Korean pharmacopoeia was selected to establish the evaluation method for efficacy of papain, pancreatin, subtilisin A and protease itself as a ingredient and protein removal tablets or solution containing those enzymes and find a suitable test conditions. Furthermore, the cleaning efficacy of commercially available protein removal tablets and solution on balafilcon A lens deposited with protein artificially was measured and the correlation between two evaluation methods was further analyzed. Results: When pancreatin itself and the product containing pancreatin was evaluated by protein digestibility assay, both reached 28 IU/mg, the standard value of protein digestibility suggested by the Korean pharmacopoeia. In case of protease and subtilisin A tested with trichloroacetic acid B solution, both of them met the enzyme activity level proposed by the manufacturers when they were evaluated by protein digestibility assay however, papain and subtilisin A tested with trichloroacetic acid A solution were not reached the enzyme activity level. Among protein removal agents, three products except a product containing pancreatin did not meet the enzyme activity value specified by the manufacturer when they were evaluated by protein digestibility assay. However, actual protein removal efficacy of three products except a papain-containing product on the lens was greater than 90% protein removal. In the case of papain-containing protein removal product, its effect was not measured by protein digestibility assay however, its actual protein removal efficacy on the lens reached 73.72%. Conclusions: From the results, it was confirmed that the efficacy of protein removal agents for contact lens should be evaluated by different method according to the type of proteolytic enzyme contained. That is, the protein removal agents containing pancreatin, protease and subtilisin A can be evaluated by protein digestibility assay and protein removal efficiency evaluation and the products containing papain can be effectively evaluated by only the evaluation method for protein removal efficiency employing the lens.

The Comparative Study on the wettability of the RGP lens multi-purpose solutions(MPSs) (RGP lens 다목적용액의 습윤성에 관한 비교 연구)

  • Park, Hyun-Ju;Goe, Eun-Kyung;Seo, Eun-Sun;Kim, Jai-Min;Lee, Ki-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.2
    • /
    • pp.119-127
    • /
    • 2003
  • We measured the effect of wettability of six MPSs for RGP lens. The used MPSs(multipurpose solutions) were OPTI-SOAK(ALCON), SOLO care hard(CIBA Vision), Total care(ALLERGAN), Simplicity(BOSTON). Wetting and Soaking Sol.(Bausch & Lomb) and Aquas-multi(Saehan). These MPSs keeps hydrophilic property of lens surface and increase the effect of cleaning or increase the effect of preservative effect. To compare with the effect of wettability we followed the way of contact angle measurement which was general way to measure wettability and compared lens which was conducted by each MPS made by different companies. As a control, 0.9% NaCl solution and artificial tears were used. The degree of the effect of wettability was decided by contact angle. It is hydrophilic property nearby $0^{\circ}$ of contact angle and it is closed by hydrophobic property as it increases. To compare with the effect of wettability we followed the way of contact angle measurement which was general way to measure wettability and compared lens which was conducted by each MPS made by different companies. As a control, 0.9% NaCl solution and artificial tears were used. The degree of the effect of wettability was decided by contact angle. It is hydrophilic property nearby $0^{\circ}$ of contact angle and it is closed by hydrophobic property as it increases. The results showed that every lens was nearby hydrophilic property within $25^{\circ}{\sim}36^{\circ}$. Also, it was differed by various factors. The surface tension showed various differences between 19.8 and 31.3(mN/m). In the viscosity, MPSs represented the highest viscosity between $4^{\circ}C$ and $20^{\circ}C$. It was much higher than compared with the viscosity of soft lens MPS. This experiment could be used to grasping the interaction between solutions used to MPS and the natural endowments of lens and to considering the relations of different factors effecting the wettability.

  • PDF