Quality Assessment and Comparison of Several Radioimmunoassay Kits and Chemiluminescence Immunoassay Methods for Evaluating Serum Estradiol (혈중 Estradiol 농도 측정을 위한 여러 방사면역측정 검사키트 및 화학면역발광 검사법의 성능평가 및 상호비교)

  • Choi, Sung Hee;Noh, Gyeong Woon;Kim, Jin Eui;Song, Yoo Sung;Paeng, Jin Chul;Kang, Keon Wook;Lee, Dong Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.72-80
    • /
    • 2015
  • Purpose Serum estradiol ($E_2$) measurement is requested for diagnosing menstrual cycles, ovulation induction, infertility, and menopause. $E_2$ is measured using several methods and kits including radioimmunoassay (RIA) and chemiluminescece immunoassay (CLIA). The purpose of this study was to evaluate quality of these methods and to compare them with each other. Materials and Methods Seven radioimmunoassay kits and two CLIA methods were included in the analysis. Using standard samples and patient samples, intra-assay precision, inter-assay precision, correlation between other methods, sensitivity, and recovery rate were evaluated. Results For all tested kits and methods, coefficients of variance (CVs) of intra-assay precision test were 10.9~13.6% in low-level samples and less than 10% in medium and high-level samples. CVs of inter-assay precision test were 10.8~12.3% in low-level samples and less than 10% in medium and high-level samples with all tested kits and methods. Recovery rates were $92.7{\pm}12.4%$ for SIEMENS, $101.4{\pm}18.4%$ for DIAsource, $95.1{\pm}11.5%$ for AMP, $108.4{\pm}18.5%$ for BECKMAN COULTER, $104.2{\pm}13.5%$ for BECKMAN COULTER Ultra Sensitive, $101.3{\pm}11.6%$ for CIS Bio, and $93.1{\pm}13.2%$ for MP kits. Sensitivity was 7.5, 6.2, 5.7, 6.2, 5.3, 4.5, and 5.5 pg/mL for SIEMENS, DIAsource, AMP, BECKMAN COULTER, BECKMAN COULTER Ultra Sensitive, CIS Bio, and MP kits, respectively. The measurement by MP kit was slightly higher than those by other kits in low-level samples, and the measurement by E170 was slightly higher than those of other kits in medium and high-level samples. In the measurement of standard sample for external quality control, SIEMENS kit produced relatively lower values whereas E170, Architect, and MP kits produced relatively higher values compared with other kits. Conclusion All tested kits for $E_2$ measurement have satisfactory performance for clinical use. However, correlation between kits should be considered when test kits are to be changed, because some pairs of kits do not have correlations with each other.

  • PDF

Effect of Airborne Lead Concentration Characterized by Size on Blood Lead and Their Relationships (납 흡수에 영향을 미치는 요인 분석: 납 크기 특성과 혈액중 납과의 관계)

  • Park, Dong-Uk;Ha, Kwon-Chul
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.4 s.85
    • /
    • pp.316-321
    • /
    • 2005
  • 4개 업종(축전지제조업, 광명단 제조업, 2차 제련업, 라디에타 제조업)에서 근무하는 총 100명의 근로자를 대상으로 8단계다단충돌기(eight stages personal cascade imparter)에 의한 입자 크기 별 납농도를 측정하였다 크기 별 납 농도는 총납(PbA), 흡입성납(IPM-PbA), 흉곽성납(TPM-PbA), 호흡성납(RPM-PbA), $1{\mu}m$ 미만의 납$(Pb_{1\mu})$ 그리고 $1{\mu}m$ 이상의 소화성납$(Pb_{ing})$이었다. 동일한 근로자(100명)를 대상으로 혈액에서 납농도를 측정하였다. 혈액 중 납은 원자흡광광도계(atomic absorption spectrometry)의 Zeeman effect graphite furnace를 이용하여 분석하였다. 총 납의 노출농도는 노출기준$(50\;ug/m^3)$을 크게 초과하였다. 평균 호흡성 납 노출농도$(115.7\;ug/m^3)$ 총 납의 노출기준을 훨씬 초과하였다. $1{\mu}m$미만의 납$(Pb_{1\mu})$ 노출농도의 범위는 0.7에서 $(492.2\;ug/m^3)$이나 되었다. 근로자의 $46\%$가 혈액 중 납 농도 40 ug/dL을 초과하였다. 60 ug/dL을 초과한 경우도 $13\%$나 되었다. 입자 크기가 큰 납인 총납, 흡입성 납 그리고 호흡성 납 농도는 혈액 중 납 농도와 유의한 상관을 보였다(p<0.0001). 그러나 가장 높은 상관은 $1{\mu}m$미만의 납$(Pb_{1\mu})$ 혈액 중 납과의 관계였다. T-test에서 $50ug/m^3$이상의 호흡성 납을 나타낸 근로자 그룹과 $50ug/m^3$ 이하의 근로자 그룹간에의 혈액 중 납 농도는 유의한 차이가 있는 것으로 나타났다(p=0.000). 이러한 연구결과는 입자크기 구분이 없는 현재의 총납에 의한 노출기준과 측정방법은 미세 납 먼지에 노출되는 근로자의 납흡수를 보호하는데 한계점이 있다는 것을 의미한다. 향후 납 입자크기는 물론 근로자의 개인적인 위생과 작업내용 등을 변수로 납 흡수에 영향을 미치는 종합적인 요인을 찾아내는 연구를 진행할 필요가 있다.

양전자 소멸 측정법에 의한 형광물질의 결함 연구

  • Lee, Jong-Yong;Gwon, Jun-Hyeon;Bae, Seok-Hwan
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.11a
    • /
    • pp.45.1-45.1
    • /
    • 2009
  • 본 연구에서는 BaSrFBr:Eu 형광물질의 결함 농도 분석을 시도하였다. 또한 동시 계수 방법과 Fast -Slow - Coincidence 시스템으로 구성한 양전자 수명 측정법을 통하여 에너지의 변화에 따른 양성자 조사에 의한 시료 결함에 따른 동시 계수 도플러법과 양전자 수명의 변화를 측정 하였으며, SRIM 시뮬레이션을 통한 에너지에 따른 양성자 투과 깊이의 변화를 연구하였다.

  • PDF

단기 측정용 오존 간이 측정기의 실험 챔버 내에서 성능에 관한 연구

  • Jeong, Sang-Jin
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2007.05a
    • /
    • pp.31-33
    • /
    • 2007
  • 본 연구에서 개발한 단기측정용(1시간) 오존 간이측정기는 $40ppm{\ast}min$(1시간 환경기준 농도(0.15ppm)에 266분(약 4.4시간) 노출되는 경우)까지 선형 변화를 나타내었으며 그 이상에서는 비선형적으로 변화하였다. 본 연구에서 개발한 단기측정용 오존 간이측정기의 현장 적용을 위해서는 현장측정에 대한 검증이 필요하며 기준성 오염물외 다른 오염물질과 실외 기상현상(예; 풍향, 풍속, 온도 등)의 영향 검토에 대한 이후의 연구가 필요하며 간이측정기의 장기간 보관을 위한 저장법에 대한 장래 연구가 필요하다.

  • PDF

Study on the Measurement of CO Gas Concentration Using TDLAS (TDLAS를 이용한 CO 농도 측정에 관한 연구)

  • 문성욱;전형하;우미혜;남기중;이성풍;류광현;권남익
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.07a
    • /
    • pp.178-179
    • /
    • 2003
  • 가스 상태의 반응 공정을 이용하는 반도체, 플라즈마, 연소 및 촉매를 이용한 유해가스처리와 대기환경 등에서는 반응을 주도하는 활성기(radical)의 역할 그리고 극미량(sub-ppm 수준)으로 존재하는 유해가스 성분등을 실시간으로 추적하는 것은 매우 중요하다. 현재 사용되고 있는 비 광학적 미량 가스 측정 장비들은 측정 대상 가스성분과 측정 장치의 프로브 사이의 물리적인 접촉이 요구되므로 감지시간이 늦고, 프로브 오염에 따른 hysteresis, 회복시간(recovery time)의 지연, 활성(부식성) 가스 샘플에 의한 감지기능 저하 등을 유발한다. (중략)

  • PDF

Examination of factors affecting seasonal variations of VOC concentrations (대기중 VOC의 계절적 농도에 영향을 주는 요인 관찰)

  • 나광삼;김용표
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.04a
    • /
    • pp.60-61
    • /
    • 2000
  • 온도의 변화에 따라 계절이 뚜렷하게 구분되는 지역에서 VOC (volatile organic compound, 휘발성 유기화합물)의 계절적 농도는 겨울에 농도가 높고 여름에 낮은 거동을 나타낸다. 이러한 농도 경향에서는 단지 겉으로 나타나는 농도의 절대치로는 계절적 농도 거동에 영향을 주는 요인들을 파악하기 어렵다. 이 연구에서는 측정된 농도가 지니고 있는 계절적 특성을 유추하기 위한 간접적 방법으로 주요 성분들의 농도비를 이용하였다. (중략)

  • PDF

Preparation of Phenoxy-Methylamino Cosubstituted Polyphosphazene Diagnostic Membranes for Blood Glucose Measurements (혈당 측정을 위한 페녹시-메틸아미노기가 함께 치환된 폴리포스파젠 진단막의 제조)

  • Kwon, Suk-Ky
    • Membrane Journal
    • /
    • v.24 no.4
    • /
    • pp.268-275
    • /
    • 2014
  • The water-insoluble poly(phenoxy-methylamino)phosphazene has been synthesized and investigated as the new type of diagnostic membrane for the measurements of blood glucose level. Final absorbances at 680 nm through activated polyphosphazene membranes were measured at various concentration of glucose in blood. The end-point results of varing absorbance values according to time (K/S) were used to obtain glucose concentration. The effects of substitution rates with hydrophilic methylamino groups and hydrophobic phenoxy groups on the measurements of glucose concentration were studied. Dose-response slope (DRS) values between glucose concentration and K/S values increased as the hydrophilic substitution rates increased. However, in less than 5% of the hydrophilic substitution rates, DRS values are too low, and in more than 25% of the hydrophilic substitution rates, because DRS increased rapidly, it was difficult to measure exact concentration level of glucose.

The Characteristic Analysis of Sediment Discharge in 2009 (2009년 하천 유사량 특성 분석)

  • Go, Ju-Yeon;Lee, Yeon-Kil;Lee, Jin-Won;Jung, Sung-Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.1729-1733
    • /
    • 2010
  • 본 연구에서는 7개 지점(여주, 적성, 왜관, 진동, 공주, 구례2, 나주)에 대해 유사량 특성 분석을 수행하였다. 부유사량은 강우가 집중되는 홍수기와 이의 전 후시기인 저 평수기(2회)로 나누어 왕복수심적분법(D-74)으로 측정하였고, 하상토는 BM-54, Grab Sampler(60 L), 선격자 등을 이용하여 홍수기 전 후로 2회 채취하였다. 채취된 시료는 그 목적에 따라 여과법(부유사농도), BW관법(부유사입도분포), 체분석법(하상토입도분포)으로 분석하였고, 그 결과로 작성된 평균 부유사농도 및 Oden Curve와 입도분포곡선과 수리량(수위, 유속, 측정수심, 수면폭, 수면경사, 수온)등의 자료를 이용하여 총유사량(미측정구간의 유사량 포함)을 추정(실측+계산: Modified Einstein)하였다. 총유사량 추정시, 세류사량을 제외한 부유사량을 적용하였다. 유량-부유사농도와 부유사량 및 총유사량 관계에 대한 결과는 다음과 같다: 1) 하나의 강우사상의 수위 상승-첨두-하강에 대한 측정성과는 대체적으로 Loop 형태를 보였고 이로 인해 일부 지점에서 측정성과들 간의 산포도가 다소 크게 나타났으며 수위 하강 때보다 상승시 초기 탁도의 증가 현상으로 부유사농도가 더 높은 것을 볼 수 있었다. 2) 유량-부유사농도, 부유사량, 총유사량 관계에서 왜관과 공주 지점의 경우, 첨두 수위에서 값들의 최고치를 보였고 나머지 지점들은 첨두 수위의 앞선 측정 수위에서 최고치를 보였다. 이는 강우사상별, 강우강도, 댐 방류량, 수위 상승-하강부, 유량에 따른 부유사농도와 부유사량의 특성이 각각 다른 점과 총유사량 추정시, 추정방법에서 추천하는 범위에서 벗어나는 자료를 적용해서 나타나는 결과로 판단된다. 여기서 유량, 수심, 하상토의 입도크기 등 자료의 범위가 추정공식들이 추천하는 범위에서 벗어나면 그 분석 결과도 서로 다르게 나타난다는 것은 그만큼 총유사량 공식의 범용성이 적다는 것을 의미한다. 이러한 점에서 때로는 자료 전체에 대해 전반적으로 양호한 결과를 보이는 공식보다는 정확한 답을 원하는 자료의 범위 내에서 예측하는 공식을 선정하는 것이 필요하다. 즉, 공식을 적용하여 유사량을 추정하고자 하는 하천이나 수로의 특성에 맞는 유사량 공식을 선정하는 것이 중요하다는 것이다.

  • PDF

Experimental Study on the Isobaric Thermal Expansion Coefficient Density and Zero-shear-rate Viscosity of Viscoelastic Fluid (점탄성 유체의 정압 열팽창계수, 밀도 및 전단속도 0에서의 점동에 대한 실험연구)

  • 최민구
    • The Korean Journal of Rheology
    • /
    • v.7 no.3
    • /
    • pp.181-191
    • /
    • 1995
  • 점탄성유체의 물성치들 중 정압열팽창계수 및 밀도는 자연대류 열전달 연구에 전단 속도 0에서의 점도는 점탄성유체에 대한 모델들 사용 시 필요하다. 본 연구에서는 점탄성유 체이며 마찰 감소 첨가제, 유전자 분리용액동으로 사용하는 Separan AP-273 용액의 정압열 팽창계수, 밀도 및 전단속도 0에서의 점도에대한 농도 및 온도의 영향을 조사하였다. 작동유 체의 물성치들은 10~6$0^{\circ}C$의 온도범위와 100~20,000wppm의 농도범위에서 측정되었다. 작 동유체의 물성치들에 미치는 열주기와 노화의 영향을 조사하기 위해서 정압열팽창계수와 전 단속도 0에서의 점도를 교대로 두 번씩 측정했다. 정압열팽창계수 및 밀도를 측정하는 장치 의 측정 정밀도는 증류수에 대한 측정치와 문헌에 나타난 자료를 비교하여 얻었고 이는 $\pm$ 2%이내였다. Separan AP-273용액의 정압열팽창계수 및 밀도는 증류수의 값들로 대치될수 있다. 작동유체의 정압열팽창계수와 밀도는 열주기와 노화의 영향을 받지 않았다. 낙하식 점 도계를 사용해 측정한 겉보기점도 값들을 나타내느 flow curve에서 전단속도가 0이 되는방 향으로 겉보기점도를 외삽시켜 Separan AP-273용액에 대한 전단속도0에서의 점도를 얻었 다. 정압열팽창계수 측정 전후에 측정한 작동유체에 대한 전단속도 0에서의 점도는 열주기 와 노화로 인해 퇴화되었다.

  • PDF

Effectiveness Evaluation of the Tube Voltage Measurement by using Additional Filter (부가필터를 이용한 kVp 측정의 실효성 평가)

  • Hwang, Jun-Ho;Lee, Kyung-Ho;Choi, Yoon-Bong;Kang, Byung-Sam
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.355-363
    • /
    • 2015
  • Advancement in the medical field provides an opportunity for the development of medical equipment and also enable accurate diagnosis for the inspection and the treatment of diseases. The aging of equipment due to the frequent operation produce uncertainty in the patient exposure dose, so a quality control was implemented by establishing a safety management system on a regular basis. The x-ray tube voltage (kVp), which is directly involved in the patient exposure dose and the life of the equipment, needs periodic performance for the quality control, but it has a limitation due to the time and the cost. In this study, we proposed a new method for measuring the kVp with ease by using the Y and Cu to solve the problem of the time and cost. We also evaluated the usefulness and the effectiveness of the new method and its accuracy through the kVp measurement. After securing the condition, the amount of the tube current and evaluating the usefulness and effectiveness of kVp measured using Y and Cu. The density range used was at 0.5-1.0, kVp was in the range of ${\pm}10%$, then, we recorded the change in concentration as % of Y and Cu. This experiment showed that when Cu and Y was at 75 kVp, concentration was the same, and when the kVp was changed to 65 ~ 85 %, a gradual increase in concentration to 85 ~ 110 % was noted.