Effectiveness Evaluation of the Tube Voltage Measurement by using Additional Filter  

Hwang, Jun-Ho (Dept. of Radiology, Kyung Hee University Medical Center)
Lee, Kyung-Ho (Dept. of Radiology, Kyung Hee University Medical Center)
Choi, Yoon-Bong (Dept. of Radiology, Kyung Hee University Medical Center)
Kang, Byung-Sam (Dept. of Radiological Technology, Shingu College)
Publication Information
Journal of radiological science and technology / v.38, no.4, 2015 , pp. 355-363 More about this Journal
Abstract
Advancement in the medical field provides an opportunity for the development of medical equipment and also enable accurate diagnosis for the inspection and the treatment of diseases. The aging of equipment due to the frequent operation produce uncertainty in the patient exposure dose, so a quality control was implemented by establishing a safety management system on a regular basis. The x-ray tube voltage (kVp), which is directly involved in the patient exposure dose and the life of the equipment, needs periodic performance for the quality control, but it has a limitation due to the time and the cost. In this study, we proposed a new method for measuring the kVp with ease by using the Y and Cu to solve the problem of the time and cost. We also evaluated the usefulness and the effectiveness of the new method and its accuracy through the kVp measurement. After securing the condition, the amount of the tube current and evaluating the usefulness and effectiveness of kVp measured using Y and Cu. The density range used was at 0.5-1.0, kVp was in the range of ${\pm}10%$, then, we recorded the change in concentration as % of Y and Cu. This experiment showed that when Cu and Y was at 75 kVp, concentration was the same, and when the kVp was changed to 65 ~ 85 %, a gradual increase in concentration to 85 ~ 110 % was noted.
Keywords
Quality Control; kVp; Copper(Cu) and Yttrium(Y); Mass Energy Absorption Coefficients; Concentration;
Citations & Related Records
Times Cited By KSCI : 7  (Citation Analysis)
연도 인용수 순위
1 Ingyu You, Cheonghwan Lim, Sangho Lee, Mankoo Lee: Performance Measurement of Diagnostic X Ray System, Journal of the Korean Society of Radiology, 6(6), 447-454, 2012   DOI
2 Radiation Health Management Textbook Compilation Committee: Radiation Control, Chung Gu Publisher, 50-54, 2004
3 Byungsam Kang, Hoonhee Park, Kyung rae Dong, Hwayeon Yeo : A Quality Control Study of the General X-ray Systems, Journal of Engineering Technology, 31-35, 2013
4 Seungyeol Lee: Records Management Business Nationwide Implementation of the Radiation Exposure Patient Dose of CT, Food and Drug Administration, 2014
5 Yeji Heo, Kyotae Kim, Sicheul Noh, Sanghee Nam, Jikoon Park: A Base Study on the Constancy Quality Control Test and Clause of Diagnosis Radiation Equipment, Journal of the Korean Society of Radiology, 8(3), 105-110, 2014   DOI
6 Jaelyong Seo: The Present Condition and Improvement Program of the Diagnostic Safety Management, Journal of the Korean Radiological Technologists Association, 260-268, 2001
7 Byungsam Kang, Kangmin Lee, Wooyoug Sim, Sunchul Park, Hakdong Choi, Youngkwan Cho: Analyze for the Quality Control of General X-ray Systems in Capital region, Journal of radiological science and technology , 35(2), 93, 2012
8 Byungsam Kang, Jinhyun Son, Seungchul Kim: Establishment of Quality Control System for Angiographic Unit, Journal of the Korea Contents Association, 11(1), 236-244,2011   DOI
9 http://quart.de/en/test-phantoms/radiography/quart-spdl.html(2014.08.01.).
10 Junho Hwang, Jisun Kwak, Aram Go, Uncheol Baek, Daeyoung Kim: Evaluation of the Usefulness and Effectiveness of the Tube Voltage Measured through the Cu and Y, Journal of Radiological Technology of Shingu College, 29, 87-103, 2014
11 Jinhyun Son, Junghwan Min, Kwangyeol Ryu, et al.: Experimental Study with Respect to Dose Characteristic of Glass Dosimeter for Low-Energy by Using Internal Detector of Piranha 657, Journal of radiological science and technology, 35(2), 119-124, 2012
12 Hwangyo Jung, Kyooyoung Kim: A Comparison of Effect of Yttrium Coating on the High Temperature Oxidation Resistance of $Ni_3Al$ and TiAl alloys, Journal of the Corros Science of korea vol26 No. 2, May, 1997
13 https://ko.wikipedia.org/wiki(2014.05.08.).
14 Namgil Choi, Hojin Seoung, Jusub Jyun, Yoonhyun kim, Donguk seoung: A Comparative Study of Image Quality and Radiation Dose according to Variable Added Filter and Radiation Exposure in Diagnostic X-Ray Radiography, Journal of Radiation Protection, 37(1), 25-34, 2012   DOI
15 Sooin Shin, Chongyeal Kim, Sungchul Kim: The Study on the Reduction of Patient Surface Dose Through the use of Copper Filter in a Digital Chest Radiography, Journal of radiological science and technology, 31(3), 223-228, 2008
16 Youngil Kim, Kwanghyon Kyong: A Study of Total Filtration of the Diagnostic X-ray Equipments, Journal of Korean Society of radiological technology, 7(1), 47-52, 1984
17 http://physics.nist.gov/PhysRefData/XrayMassCoef/tab3.html(2014.03.14.).
18 Hyunsoo Lim, Bugil Kim: Establishment of Standard of Property Control for Angiographic Equipments, Journal of the Institute of Electronics Engineers of Korea, 41(6), 11, 61-66, 2004
19 Radiation Theory and Practice: Korea Radioisotope Association, 71-78, 2013