• Title/Summary/Keyword: 농도 측정

Search Result 10,125, Processing Time 0.042 seconds

Effects of Temperature and Humidity on the Glucose Measurements with Phenoxy-Methylamino Phosphazene Diagnostic Membranes (페녹시-메틸아미노 포스파젠 당뇨병 진단막의 글루코우즈 농도 측정에 미치는 온도와 습도의 영향)

  • Kwon, Suk-Ky
    • Membrane Journal
    • /
    • v.26 no.3
    • /
    • pp.179-186
    • /
    • 2016
  • The new types of phenoxy-methylamino phosphazene diagnostic membranes were prepared to measure blood glucose level of diabetics. Firstly, effects of mesuring environments on the glucose measurements were examined. With activated phosphazene membranes, the end-point results of varing absorbance values according to time (K/S) were measured at 5, 15, 25, 35, $50^{\circ}C$ and also at 20% to 80% of relative humidities (RH). The slope values of K/S and glucose concentration(DRS) were not seriously affected at high measuring temperatures and humidities. Secondly, after prepared membranes were stored at various environments, the effects of storage temperatures and humidities on the glucose measurements were examined. After 8 weeks at $50^{\circ}C$, the storage time and temperatures did not affect on the glucose measurements with the new phosphazene membranes. The stabilities of new phosphazene diagnostic membranes were confirmed even at RH 80%.

A comparative Study on the Colorimeter and Densitometer Analysis in Color Measurement for Reproduced Colors Variable Dot Area Rates (다색 망점 인쇄물의 색측정에서 농도 측정 방법과 자극치 직독 방법의 비교에 관한 연구)

  • ChulWhoiKoo
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.2 no.1
    • /
    • pp.45-64
    • /
    • 1984
  • NiNH4PO4 was Prepared from waste Ni catalyst used in hydrogenation of oil and fat. NiNH4PO4 was calcined at different temperature respectly 800,100,100˚C to prepare Nickel yellow. The result from this experiment are summerizer as follows: 1) Nickel yellow formed at 1100˚C was most clearness yellow color from color analyzer date. 2) Nickel yellow was consist of -Ni2P2O2 Ni3(PO4)2 from X-ray diffraction analysis. 3) The endothermic pick at 100˚C and exotherwic pick about 1050˚C on calcination of NiNH4PO4 were checked in DTA (difference Thermal analysis data.)

  • PDF

대구시 주거지역의 오존농도 평가

  • Kim, Beom-Jun;Choe, Seong-U;Kim, Hye-Jin;Choe, Hyeok
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2006.11a
    • /
    • pp.122-123
    • /
    • 2006
  • 본 연구에서는 2001년부터 2005년까지의 최근 5년간의 대구시 보건환경연구원의 대기질 자동측정망 자료와 대구기상대의 기상자료를 이용하여 통계적 방법을 이용하여 대구시 주거지역의 오존농도를 평가하였다. 분석기간은 2001년부터 2005년까지 고농도 오존일이 가장 많이 발생한 5, 6월을 대상으로 하여, 오존농도와 대기오염물질 및 기상요소와의 상관관계분석과 교차상관관계 분석을 실시하였다. 대구지역의 오존농도는 측정지점별로 약간의 차이는 있지만, 기온 및 일사량이 증가하는 하절기에 증가하고, 동절기에 감소하는 전형적인 패턴을 보여주었다. 분석기간 중 오존최고농도는 상관관계분석 결과 고농도 오존에 영향을 주는 인자로 대기오염물질로는 $NO_2$, NO 그리고 기상요소로는 온도, 상대습도, 일사량으로 나타났다. 교차상관관계분석 결과 NO2, NO, 온도와 상대습도는 0시간 차이에서 가장 높은 상관계수를 나타내었으며, 일사량의 경우 오존농도가 최고치를 나타낼 때보다 -2시간 차이에서 가장 높은 상관계수를 나타내었다.

  • PDF

암반대수층에서 양수조건에 따른 세레늄 농도변화의 현장사례 연구

  • Son Ju-Hyeong;Jeong Sang-Yong;Gang Dong-Hwan;Sin Hyeon-Chae;Jeong Yong-Je
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2006.04a
    • /
    • pp.255-258
    • /
    • 2006
  • 인위적인 오염원이 존재하지 않는 농촌지역 지하수공에서 검출빈도가 매우 낮은 세레늄 성분에 대하여 양수조건에 따른 세레늄의 농도변화를 연구하였다. 양수에 따른 세레늄 농도변화의 연구는 현장지하수 수질이 지하수 먹는물 수질기준보다. 높은 2개의 지하수공에서 수행되었다. 본 연구를 통해, 세레늄 성분이 먹는물 수질기준을 초과한 지하수공의 지속적인 이용여부를 판단하였다. 또한, 양수시험공 주변의 세레늄 농도를 측정하여 배경농도를 파악하였으며, 시험공 내에서 구간별 채수를 수행하여 세레늄 성분이 산출되는 주대수층 구간을 파악하였다. 양수조건에 따른 세레늄의 농도변화를 연구하기 위한 방법은 하루 8시간을 기준으로 양수하는 단기적인 방법과, $4,950m^3$을 594시간 동안 장기양수하면서 농도변화를 측정하였다. 본 연구를 통해, 지하수 내 세레늄 성분의 농도변화는 장기양수에 의해 변화함을 알 수 있었다.

  • PDF

Analysis of Flow-Weighted Mean Concentration(FWMC) Characteristics of Rainfall Runoff (강우유출수의 유량가중평균농도 분석)

  • Shin, Yong-Chul;Shin, Min-Hwan;Kim, Woong-Ki;Heo, Sung-Gu;Lim, Kyoung-Jae;Kim, Ki-Sung;Choi, Joong-Dae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.951-955
    • /
    • 2007
  • 본 연구에서는 산림유역과 농지와 임야가 혼합된 유역에서 발생하는 강우유출수의 유량가중평균농도를 분석하기 위해 강원도 춘천시에 위치한 강원학교 학술림, 유포리 및 월곡리 소하천을 대상으로 유량 수질 자료를 수집하여 분석하였으며, 유역별로 각각 21개의 유량가중평균농도를 산정하였다. 유역별 21개 강우사상에 대한 수질항목별 평균 유량가중평균농도 농도는 유포리(AW1) > 월곡리(AW2) > 학술림(FW) 순서로 농업유역의 유량가중평균농도가 산림유역에 비해 높은 것으로 나타났다. 연구유역의 유출량에 영향을 미치는 인자로는 강우량과 유역면적의 상관도가 높게 나타났으며, 강우량에는 강우강도가 영향을 미치는 것으로 나타났다. 대부분의 수질항목간의 상관도가 있는 것으로 나타났으나, 유기물 함량을 측정하는 COD의 경우 물속의 영양물질 양을 측정하는 T-N 및 T-P와 관계가 없는 것으로 나타났다.

  • PDF

Comparison of VOCs Concentration Characteristic According to Measurement Methods in Exhibition Hall (휘발성유기화합물(VOCs)의 측정방법에 따른 유물 전시관 내 농도 분포 특성 비교)

  • Lim, BoA;Lee, Sun Myung
    • 보존과학연구
    • /
    • s.35
    • /
    • pp.25-44
    • /
    • 2014
  • In this study, measured annual year and seasonal concentrations of VOCs by Active type and Passive type using the measurement and analysis method in the exhibition hall and outdoor. It was compared with the correlation between the methods according the comparison of methods to measured concentrations. As a results, the annual average concentrations of TVOC in exhibition room($906.5{\mu}g/m^3$) was greater than for most of the study period, more than 1.8 times the standard in the Ministry of Environment. ${\Sigma}VOCs$ concentration of exhibition room by Active type was higher than Passive type. Some VOCs was decreased with the lapse of time a temporary increase tendencies was. The annual average I/O ratio of TVOC was 9.0, ${\Sigma}VOCs$ was confirmed to occur in a large amount inside the exhibition hall ${\Sigma}VOCs$ was studied to 34.0. Correlation coefficient of ${\Sigma}VOCs$ was 0.367. Toluene was 0.567 that the survey was the largest analysis to the relationship between the two methods.

  • PDF

Ultrasonic Velocity and Absorption Measurements for poly (sodium 4-styrenesulfonate) and Water Solutions (Poly (sodium 4-styrenesulfonate)/ 물 이성분용액의 초음파 음속 및 흡수계수측정)

  • 배종림
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.7
    • /
    • pp.497-502
    • /
    • 2004
  • Both ultrasonic velocity at 3 MHz and absorption coefficient in the frequency range of 0.2-2 MHz were measured for poly (sodium 4-styrenesulfonate) aqueous solution over the concentration range of 5 to 25 % by weight. Pulse echo overlap method was employed to measure the ultrasonic velocity over the temperature range of 10-90 ℃ and the high-a ultrasonic resonator method was used for the absorption coefficient measurement at 20 ℃. The velocity exhibited a maximum value at approximately 55. 59, 63. 67, and 71 ℃ in 25, 20. 15, 10. and 5 wt% solutions, respectively. The velocity increased with poly (sodium 4-styrenesulfonate) concentration at a given temperature. The concentrations dependences of the relaxation frequency and amplitude showed that the relaxation around 200 kHz is related to the structural fluctuations of polymer molecules, such as the segmental motions of the polymer chains and that around 1 MHz resulted from the proton transfer reaction of the oxygen sites of SO₃. Both the absorption and the shear viscosity increase with the Polymer concentration. but decrease with temperature.

Analysis of ethanol concentration and refractive-index by use of surface plasmon resonance effect (표면 플라즈몬 공명에 의한 에탄올의 농도 및 굴절률 분석)

  • 도용화;이관수;송석호;손대원;이상선
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.1
    • /
    • pp.9-14
    • /
    • 2002
  • A surface plasmon sensor has been fabricated for detection of concentration and refractive-index of a mixed solution. Based on the Kretschmann-Raether attenuated-total-reflection configuration, the sensor consists of 54 nm-thick Ag metal layer under a prism and a cell containing the mixed solution. We have observed a nonlinear refractive-index change as the ethanol-water concentration increased. The experimental results show us that the detection limit of the SPR sensor is 3$\times$10$^{-2}$ % in ethanol mass ratio. The concentration-to-index curve shows a linear increase in the range of ethanol concentration from 0% to 50%, but a nonlinearity is observed beyond 50%. We have modeled the nonlinearity and compared it with the experimental results.

Comparisons of sample preparation (acid digestion and microwave digestion) and measurement (inductively coupled plasma mass spectrometry and graphite furnace atomic absorption spectrometry) in the determination of bone lead (골중납 측정의 시료 전처리 (산분해법과 마이크로웨이브 분해법)와 측정 방법 (유도결합 플라즈마 질량분석법과 흑연로 원자 흡수 분광 광도법)의 비교)

  • Yoon, Chungsik;Choi, Inja;Park, Sungkyun;Kim, Rokho
    • Analytical Science and Technology
    • /
    • v.16 no.2
    • /
    • pp.152-158
    • /
    • 2003
  • This study was conducted to evaluate two sample digestion procedures and instrumental determination parameters for analysis of lead in bone. Amputated human legs were treated by acid digestion or microwave dissolution prior to spectrometric analysis. Inductively coupled plasma mass spectrometry (ICP-MS) and graphite furnace atomic absorption spectrometry (GF-AAS) were used for determining bone lead levels. Recovery efficiencies using standard reference material from acid digestion measured by ICP-MS were in good agreement with those of the certified value, but in cases of acid digestion by GF-AAS and microwave digestion by both two methods, recovery underestimated and overestimated, respectively. For the bone samples, the lead concentrations obtained by ICP-MS after acid digestionwere in good agreement with those by GF-AAS (correlation coefficient = 0.983), but GF-AAS gave systematically higher values than ICP-MS. While a good agreement between two analytical methods after microwave digestion was also obtained (correlation coefficient = 0.950), bone lead concentrations from microwave were relatively higher than those from acid digestion. In conclusion, the use of the simple nitric acid digestion procedure at an ambient temperature coupled to ICP-MS seems to be efficient for the determination of lead in bone in consideration for both the convenience and validity.

Characterization of Annual PM2.5 and PM10 Concentrations by Real-time Measurements in Cheonan, Chungnam (실시간 측정을 통한 천안시 대기 중 연간 PM2.5, PM10 농도 특성 조사)

  • Heo, Jung-Hyuk;Oh, Se-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.1
    • /
    • pp.445-450
    • /
    • 2012
  • From 2015, PM2.5 standards will be added to Korean national ambient air quality standards. To characterize PM2.5 levels in Cheonan, annual PM2.5 concentrations along with PM10 concentrations were investigated between February 2010 and January 2011 using a dust monitor. The annual PM2.5 concentration was $40.45{\mu}g/m^3$ and over the standards($25{\mu}g/m^3$). The daily average PM2.5 concentrations ranged from 2.43 to $178.84{\mu}g/m^3$, and 26% days exceeded the daily PM2.5 standard($50{\mu}g/m^3$). During the same periods, only 11% days exceeded the daily PM10 standard, showing that PM2.5 were more concerning levels than PM10. Seasonal variations showed the highest concentrations in spring and winter, and lowest concentration in summer due to heavy rain fall. Changes in PM2.5 concentrations during the day were remarkable and showed the highest concentrations in commuting periods. The results indicated that the concentrations of PM2.5 in Cheonan were at the concerning level, and mainly from the mobile sources.