Abstract
The new types of phenoxy-methylamino phosphazene diagnostic membranes were prepared to measure blood glucose level of diabetics. Firstly, effects of mesuring environments on the glucose measurements were examined. With activated phosphazene membranes, the end-point results of varing absorbance values according to time (K/S) were measured at 5, 15, 25, 35, $50^{\circ}C$ and also at 20% to 80% of relative humidities (RH). The slope values of K/S and glucose concentration(DRS) were not seriously affected at high measuring temperatures and humidities. Secondly, after prepared membranes were stored at various environments, the effects of storage temperatures and humidities on the glucose measurements were examined. After 8 weeks at $50^{\circ}C$, the storage time and temperatures did not affect on the glucose measurements with the new phosphazene membranes. The stabilities of new phosphazene diagnostic membranes were confirmed even at RH 80%.
Keywords
temperature; humidity; phosphazene; membranes; glucose; measurements;
Citations & Related Records
Times Cited By KSCI : 4  (Citation Analysis)
연도 인용수 순위
1 K. Huh, "Diabetic health", D and C Media, Seoul (2006).
2 Y. Kim, "Diabetes treatment", Medbook, Seoul (2012).
3 Home Health Management Research Institute, "Diabetes", Kumyoung, Seoul (1992).
4 Seoul National University Hospital, "A guide for diabetes management", Bummoon education, Seoul (2012).
5 Y. Cho, "Diabetes, as much as know that look", Miraejysik, Seoul (2006).
6 T. Asano and T. Norioka, "Diabetes", Nihon Bungeisha, Tokyo (2000).
7 J. Kim, "Diabetes: Diagnostics and control", Ohsung, Seoul (1997).
8 S. Kim, "Life guide for diabetes control", Hyoseong, Seoul (1993).
9 T. Asano, "Diabetic food and life style", Shufu-To-Seikatsusha Co., Tokyo (2005).
10 S. Kwon, "Studies on the polyurethane diagnostic membrane for diabetes (2): Effects of additives in membrane formulations for the measurement of urine glucose", Polymer(Korea), 18, 6 (1994).
11 S. Kwon, "Basic studies on the preparation of diagnostic membranes by using multi-layered gelatin films to measure blood glucose level of diabetics", Membr. J., 8, 1 (1998).
12 S. Kwon and M. Choi, "The preparation of polyacrylonitrile diagnostic membranes for blood glucose measurements (2): Effects of blood constituens on the measurements of glucose concentration", Membr. J., 18, 4 (2008).
13 S. Kwon, "A study on the preparation of polyurethane diagnostic membrane for urine glucose test", Appl. Chem. Eng., 5, 6 (1994).
14 S. Kwon, "Preparation of phenoxy-methylamino cosubstituted polyphosphazene diagnostic membranes for bllod glucose measurement", Membr. J., 24, 4 (2014).
15 S. Kwon, "Effects of interferents in blood on the blood glucose measurements by using polyphosphazene diagnostic membranes", Membr. J., 23, 4 (2013).
16 S. Kwon, I. Park, and D. Yoon, "The preparation of polyacrylonitrile diagonostic membranes for blood glucose measurements (1): Effects of temperature and humidity on the measurements of glucose concentration", Membr. J., 17, 4 (2007).
17 S. Kwon, "Studies on the preparation of diagnostic membranes for blood glucose measurements (2): Effects of temperature on the measurements of glucose concentration", Hongik Industrial Technology, 13, 551 (2003).
18 R. P. Back, "Biosensor technology", Marcel Dekker, New York (1990).
19 S. Kwon, "Studies on the muti-layered gelatin diagnostic membranes for diabetes (2): Effects of interferents in blood on the diffusion-controlled rates of glucose", Membr. J., 9, 4 (1999).
20 R. E. Kesting, "Synthetic polymeric membranes", Wiley-Interscience, New York (1985).
21 M. Gordon, "Polymer membranes", Springer-Verlag, New York (1985).
22 S. Kwon, "Preparation of polyurethane diagnostic membranes for blood glucose measurements (6): Effects of hematocrit on the measurements of glucose concentration", Membr. J., 20, 3 (2010).
23 H. R. Allcock and S. Kwon, "Hydrophilic polyphosphazenes as hydrogels: Radiation crosslinking and hydrogel characteristics of poly[bis(methoxyethoxy) phosphazene]", Biomaterials, 7, 6 (1986).
24 S. Kwon, "Studies on the preparation of diagnostic membranes for blood glucose measurements (1): Model experiments by using microporous polyurethane membrane", Hongik Industrial Technology, 12, 717 (2002).
25 S. Kwon and J. Yu, "The preparation of polyacrylonitrile diagnostic membranes for blood glucose measurements (3): Effects of storage environments on the measurements of glucose concentration", Membr. J., 19, 3 (2009).
26 H. R. Allcock, M. Gebura, S. Kwon, and T. X. Neenan, "Amphiphilic polyphosphazenes as membrane materials: Influence of side group on radiation crosslinking, semipermeability, and surface morphology", Biomaterials, 9, 500 (1988).   DOI
27 S. Kwon and B. Lee, "A study on the preparation of metal-ion separation membrane with hydrophilic polyphosphazene", Appl. Chem. Eng., 10, 3 (1999).
28 S. Kwon and B. Lee, "A Study on the preparation of ion-exchange membranes with polyphosphazenes", Appl. Chem. Eng., 9, 3 (1998).
29 S. Kwon, "Effects of testing and storage environments on the blood glucose measurements by using phosphazene diagnostic membranes", Membr. J., 22, 5 (2012).
30 H. R. Allcock and S. Kwon, "Covalent linkages of proteins to surface-modified poly(organophosphazenes): Immobilization of glucose-6-phosphate dehydrogenase and trypsin", Macromolecules, 19, 1502 (1986).   DOI
31 S. Kwon, I. Park, and D. Yoon, "Studies on the preparation of polyurethane diagnostic membranes for blood glucose measurements (5): Effects of temperature and humidity on the measurements of glucose concentration", Membr. J., 17, 1 (2007).
32 S. Kwon and C. Jun, "Studies on polyphosphazenes- bound Wittig reactions", Appl. Chem. Eng., 5, 5 (1994).
33 S. Kwon, "Effects of interferents in blood on the blood glucose measurements by using the new types of phosphazene diagnostic membranes" Membr. J., 25, 3 (2015).