DOI QR코드

DOI QR Code

Effects of Temperature and Humidity on the Glucose Measurements with Phenoxy-Methylamino Phosphazene Diagnostic Membranes

페녹시-메틸아미노 포스파젠 당뇨병 진단막의 글루코우즈 농도 측정에 미치는 온도와 습도의 영향

  • Kwon, Suk-Ky (Department of Biological and Chemical Engineering, Hongik University)
  • 권석기 (홍익대학교 과학기술대학 바이오화학공학과)
  • Received : 2016.05.12
  • Accepted : 2016.05.26
  • Published : 2016.06.30

Abstract

The new types of phenoxy-methylamino phosphazene diagnostic membranes were prepared to measure blood glucose level of diabetics. Firstly, effects of mesuring environments on the glucose measurements were examined. With activated phosphazene membranes, the end-point results of varing absorbance values according to time (K/S) were measured at 5, 15, 25, 35, $50^{\circ}C$ and also at 20% to 80% of relative humidities (RH). The slope values of K/S and glucose concentration(DRS) were not seriously affected at high measuring temperatures and humidities. Secondly, after prepared membranes were stored at various environments, the effects of storage temperatures and humidities on the glucose measurements were examined. After 8 weeks at $50^{\circ}C$, the storage time and temperatures did not affect on the glucose measurements with the new phosphazene membranes. The stabilities of new phosphazene diagnostic membranes were confirmed even at RH 80%.

당뇨병 환자의 혈당을 측정하기 위해 새로운 형태의 페녹시-메틸아미노 포스파젠 진단막을 제조하였다. 먼저 측정 환경이 혈당 측정에 미치는 영향을 조사하였다. 활성화된 진단막을 가지고 5, 15, 25, 35, $45^{\circ}C$ 그리고 상대습도 20%에서 80%까지 변화시키면서 시간에 따른 680 nm에서의 흡광도 변화량(K/S)를 측정하였다. 높은 측정온도와 습도에서도 K/S와 글루코우즈 농도와의 기울기 값(Dose-Response Slope : DRS)은 크게 영향을 받지 않았다. 두 번째로, 제조된 진단막을 여러 환경에서 보관한 후, 보관 환경이 글루코우즈의 농도 측정에 미치는 영향을 조사하였다. 새로운 포스파젠 진단막을 $50^{\circ}C$에서 8주 보관한 후 측정한 결과, 보관시간과 온도가 크게 영향을 주지 않았다. 또 상대습도 80%에서도 새로운 포스파젠 진단막의 안정성이 확인되었다.

Keywords

References

  1. K. Huh, "Diabetic health", D and C Media, Seoul (2006).
  2. Y. Kim, "Diabetes treatment", Medbook, Seoul (2012).
  3. Home Health Management Research Institute, "Diabetes", Kumyoung, Seoul (1992).
  4. Seoul National University Hospital, "A guide for diabetes management", Bummoon education, Seoul (2012).
  5. Y. Cho, "Diabetes, as much as know that look", Miraejysik, Seoul (2006).
  6. T. Asano and T. Norioka, "Diabetes", Nihon Bungeisha, Tokyo (2000).
  7. J. Kim, "Diabetes: Diagnostics and control", Ohsung, Seoul (1997).
  8. S. Kim, "Life guide for diabetes control", Hyoseong, Seoul (1993).
  9. T. Asano, "Diabetic food and life style", Shufu-To-Seikatsusha Co., Tokyo (2005).
  10. S. Kwon, "Studies on the polyurethane diagnostic membrane for diabetes (2): Effects of additives in membrane formulations for the measurement of urine glucose", Polymer(Korea), 18, 6 (1994).
  11. S. Kwon, "Basic studies on the preparation of diagnostic membranes by using multi-layered gelatin films to measure blood glucose level of diabetics", Membr. J., 8, 1 (1998).
  12. S. Kwon and M. Choi, "The preparation of polyacrylonitrile diagnostic membranes for blood glucose measurements (2): Effects of blood constituens on the measurements of glucose concentration", Membr. J., 18, 4 (2008).
  13. S. Kwon, "A study on the preparation of polyurethane diagnostic membrane for urine glucose test", Appl. Chem. Eng., 5, 6 (1994).
  14. S. Kwon, "Preparation of phenoxy-methylamino cosubstituted polyphosphazene diagnostic membranes for bllod glucose measurement", Membr. J., 24, 4 (2014).
  15. S. Kwon, "Effects of interferents in blood on the blood glucose measurements by using polyphosphazene diagnostic membranes", Membr. J., 23, 4 (2013).
  16. S. Kwon, I. Park, and D. Yoon, "The preparation of polyacrylonitrile diagonostic membranes for blood glucose measurements (1): Effects of temperature and humidity on the measurements of glucose concentration", Membr. J., 17, 4 (2007).
  17. S. Kwon, "Studies on the preparation of diagnostic membranes for blood glucose measurements (2): Effects of temperature on the measurements of glucose concentration", Hongik Industrial Technology, 13, 551 (2003).
  18. R. P. Back, "Biosensor technology", Marcel Dekker, New York (1990).
  19. S. Kwon, "Studies on the muti-layered gelatin diagnostic membranes for diabetes (2): Effects of interferents in blood on the diffusion-controlled rates of glucose", Membr. J., 9, 4 (1999).
  20. R. E. Kesting, "Synthetic polymeric membranes", Wiley-Interscience, New York (1985).
  21. M. Gordon, "Polymer membranes", Springer-Verlag, New York (1985).
  22. S. Kwon, "Preparation of polyurethane diagnostic membranes for blood glucose measurements (6): Effects of hematocrit on the measurements of glucose concentration", Membr. J., 20, 3 (2010).
  23. S. Kwon, "Studies on the preparation of diagnostic membranes for blood glucose measurements (1): Model experiments by using microporous polyurethane membrane", Hongik Industrial Technology, 12, 717 (2002).
  24. S. Kwon and J. Yu, "The preparation of polyacrylonitrile diagnostic membranes for blood glucose measurements (3): Effects of storage environments on the measurements of glucose concentration", Membr. J., 19, 3 (2009).
  25. S. Kwon and C. Jun, "Studies on polyphosphazenes- bound Wittig reactions", Appl. Chem. Eng., 5, 5 (1994).
  26. H. R. Allcock, M. Gebura, S. Kwon, and T. X. Neenan, "Amphiphilic polyphosphazenes as membrane materials: Influence of side group on radiation crosslinking, semipermeability, and surface morphology", Biomaterials, 9, 500 (1988). https://doi.org/10.1016/0142-9612(88)90045-2
  27. H. R. Allcock and S. Kwon, "Hydrophilic polyphosphazenes as hydrogels: Radiation crosslinking and hydrogel characteristics of poly[bis(methoxyethoxy) phosphazene]", Biomaterials, 7, 6 (1986).
  28. S. Kwon and B. Lee, "A study on the preparation of metal-ion separation membrane with hydrophilic polyphosphazene", Appl. Chem. Eng., 10, 3 (1999).
  29. S. Kwon and B. Lee, "A Study on the preparation of ion-exchange membranes with polyphosphazenes", Appl. Chem. Eng., 9, 3 (1998).
  30. S. Kwon, "Effects of testing and storage environments on the blood glucose measurements by using phosphazene diagnostic membranes", Membr. J., 22, 5 (2012).
  31. H. R. Allcock and S. Kwon, "Covalent linkages of proteins to surface-modified poly(organophosphazenes): Immobilization of glucose-6-phosphate dehydrogenase and trypsin", Macromolecules, 19, 1502 (1986). https://doi.org/10.1021/ma00160a002
  32. S. Kwon, I. Park, and D. Yoon, "Studies on the preparation of polyurethane diagnostic membranes for blood glucose measurements (5): Effects of temperature and humidity on the measurements of glucose concentration", Membr. J., 17, 1 (2007).
  33. S. Kwon, "Effects of interferents in blood on the blood glucose measurements by using the new types of phosphazene diagnostic membranes" Membr. J., 25, 3 (2015).