• Title/Summary/Keyword: 논문지

Search Result 139,458, Processing Time 0.134 seconds

A study on the changes of the Screen quota system as a Film policy in Korea (한국의 영화정책과 스크린 쿼터제의 변천에 대한 연구)

  • Cho, Hee-Moon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.5
    • /
    • pp.982-991
    • /
    • 2006
  • The screen quota system is one of the most controversial issues in the Korean film industry. There are two different points of view regarding the system. Some say it is highly effective to protect and nurture Korean movies. However, others argue that it hurts the duality of the Korean movies. The number of days, for which Korean movies have to play on local screens, has been reduced to 73, starting on July 1st, 2006. Actually, it is 50 percent fewer than the previous year. In facL Korea has implemented the screen quota. system two times. First, it was practiced from 1935 to 1945, during the Japanese colonial period. This was to regulate imported movies, especially American ones, as the Japanese government was to use movies for the political propaganda. In 1935, the number of foreign movies screened had to be less than three fourths of the total. And they gradually reduced the size by two thirds in 1936, and again by half in 1937. After the attack on Pearl Harbor when the Pacific War happened, Japan completely banned importing American movies in Korea. The reason why it regulated the imported foreign films is to increase the number of domestic movies, both Japanese and Korean. It was for making propaganda films fur carrying the war. The second practice of the screen quota is from 1967 to the present year. It was designed to boom the Korean film industry. However, the competitive power of Korean films has not been improved in spite of the practice of the system. Moreover, the film industry has gone through the depression. Korean film agencies have occupied the Korean film market thanks to the protection by government. The founding of the film agencies has been strongly regulated. So has importing foreign movies. Under the special protection like this, Korean film agencies have been enjoying the monopoly In the mean time, they have pursued income not by making quality movies but by importing foreign movies. As a result, cinema audiences turn away form Korean films and prefer foreign movies. Furthermore, the screen quota system hurts the relationship between film producers and distributors, imposing the duties only on theaters. In short, the screen quota system has satisfied neither film producers, theater runners, nor film goers. In other words. the excessive protection has weakened the competitive power of Korean film industry.

  • PDF

A Study on the first inventor defense in the US patent law (미국에서의 선발명자 항변에 관한 연구)

  • Chang, Eun-Ik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.6
    • /
    • pp.1319-1336
    • /
    • 2006
  • The successive round of talks oil Korea-USA Free Trade Agreement (FTA) has continued, and it also has the Intellectual property(IPR) unit. Until now, tile one of most disputing concerns in IPR unit through talks is the limitation of compulsory license of claimed invention. The US is urging to establish a safeguard for IPR, as similar measure of the US, to protecting the profit of the US enterprises through these on-going talks, it is more likely expected to take the offensive about infringement of the patent seriously. Based on the current circumstances, the provision strategy study is needed to obtain Korea inventors the first inventor defense under the US patent law system as well as understand the current Korea's patent law and its revision against that in the US. In patent Law, both nations with first to file system and first to invent system permit a prior user of an invention to continue to use the invention notwithstanding its subsequent patenting by another under being subject to certain qualifications and limitations, even though a patent by a later inventor is granted. Normally, the first inventor defense has been used to compensate the drawbacks of the first to file system. The US patent Law, however, adopting the first to invent system admits the first inventor defense. Therefore, pursuing counteract provision under consideration with Korean patent Law system and research environment along with investigating the reason why the US adopted its patent law system, the scope of right, and the new reform of Act. 2005 of the institute, which promotes the first Korean inventor to possess the defense right of the US, provides certain preparations for Korean companies against the expected offensive from the US ones under the US patent Law system.

  • PDF

The study about the ruling policy of Government-General of Chosun and its use of films for the political propaganda during the Japanese colonial period(1910-1945) (일제강점기 조선총독부의 통치정책과 영화의 활용에 관한 연구)

  • Cho, Hee-Moon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.6
    • /
    • pp.1407-1415
    • /
    • 2006
  • Japan started to colonize Korea in 1910. It's when It forced and made Chosun sign on the Treaty of Protectorate. The Chosun faithfully practiced Japan's colonial policy over Korea. Futhermore, it stopped many Koreans from an anti-Japanese movement and tried to make Koreans have a positive attitude towards Japan. For this, Japan advertised the policy called Nae-sun-il-che which meant Korea and Japan were a community together from the same root. Ultimately, it targeted on absorbing Korea within their territory. With this goal, Japan kept on practicing the policy to acculturize and brainwash Koreans, totally depending on force and pressure from 1910 to 1919. However, this policy had changed by the overall anti-Japanese movement happening on March 1st 1919. Saito, the third governor-general who was appointed laster on, made an effort to win over He favor of Koreans in a less forceful way of the cultural politics. The change of policy had been specified in diverse actions such as permitting civil mass-media bodies forming the observation groups and opening conferences. In the case of daily newspapers, Japan had permitted only the ones by the Government-General of Chosun such as Maeil-shinbo, Kyunsung-ilbo, and Seoul Press before, but then other civil newspapers In Korean stated to be released. Along His Japan formed both Korean and Japanese observation groups to promote the mutual understanding and showed off Japan's goods in the propaganda films by implementing a film department. It's because Japan totally recognized and understood the impact of films. Therefore, Japan distincitively established a film agency for the production of propaganda movies while it banned the civil film production after 1937 when Japan started the war against China and USA in row. So, only one film agency, ruled by the Government-General of Chosun, produced movies from 1942 to 1945.

  • PDF

Standards of Due Diligence and Separation of Responsibilities in the Division of Labor in Medicine (분업적 의료행위에 있어서 주의의무위반 판단기준과 그 제한규칙들)

  • Choi, Hojin
    • The Korean Society of Law and Medicine
    • /
    • v.19 no.2
    • /
    • pp.41-72
    • /
    • 2018
  • In the division of labor (or teamwork) in medicine, the responsibility of medical and nursing staff should be separated or distributed to justify negligent criminal offenses. The present work refers to the standards by which the due diligence and responsibility of the individual persons are to be determined and delimited. In this context, it has been proven that objective theory as a measure of due diligence is appropriate. From a moral point of view, when assessing due diligence, it makes sense to impose greater individual or higher performance demands on the perpetrator, but law and order require that due diligence should result from socially relevant human behavior. To give objective measure of negligence and to provide the highest level of personal responsibility, so that man can not be burdened too much responsibility and it is accordingly with an equality theorem. Afterwards some points are presented, which should be considered in a concrete fact in the determination of the medical negligence. Medical action has specific characteristics such as professionalism, discretionary and exclusive, unbalance of information. These characteristics distinguish medical actions from general negligence. The general level of knowledge, the urgency, working condition and working environment of the medical facility, duration of the professional practice, assessment of the medical activity are crucial in this context. As a standard of delineation of due diligence, I have used the permitted risk and the principle of trust. In the horizontal division of labor, the principle of trust applies. The principle of trust applies in principle in cases of division of labor interaction, when doctors in the same hospital exercise their own specific occupational field or everyone works in another hospital. However, this is not true for every case. In the vertical division of labor, the principle of trust does not apply and the senior physician can not trust the assistant doctors. In this case, the principle of trust is converted into a duty of supervision for assistant doctors by the senior physician. This supervision requirement could be used as a random check.

Comparison of Operator Radiation Exposure Dose undergoing Cardiac Angiography and Cardiac Intervention (심장혈관 중재적 시술의 시술자 피폭 선량에 관한 연구)

  • Kim, Jungsu;Kwon, Soonmu;Jung, Haekyoung;Lee, Bongki;Ryu, Dongryeol;Kwon, Hoseok;Cho, Byungryul
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.3
    • /
    • pp.181-186
    • /
    • 2016
  • Cardiac angiography(CA) or cardiac intervention(CI) is one of the major examination methods applied to the detection of cardiovascular diseases using X-rays. These CA and CI procedures require radiation exposure to patients and physicians. We evaluated the radiation dose to cardiac operator during the each case of CA and CI procedures. The number of patients is 113 patients in CA and 34 patients in CI. Mean fluoroscopy time, mean cine time, and mean total cumulative dose area product(DAP) in patients during CA and CI was 165.9 sec vs. 1200.0 sec, 30.31 sec vs 107.5 sec, and $37130.3mGy.cm^2$ vs $213312.6mGy.cm^2$, respectively. Mean dose of thyroid, over chest apron and under chest apron in operator during CA and CI was 15.84 uSv vs 89.81 uSv, 20.16 uSv vs 123.20 uSv, and 0.30 uSv vs 2.40 uSv, respectively. Mean effective dose of operator during CI was about 6 times greater than during CA. Also there was significant inter-relationship between fluoroscopy or cine time and effective dose in operator during CA and CI(p=0.001 and p=0.001, respectively).

A Study on the Guardian's Perception of Attending Patient in Pediatric Radiography (소아 방사선 검사 시 보호자 참여에 대한 인식도 조사)

  • Kwak, JongHyeok;Jeong, JaeBeom
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.189-201
    • /
    • 2014
  • The purpose of this study was to survey guardian's opinion on assisting pediatric radiography and their level of awareness of radiation, improving the quality of pediatric radiography. In this study, the recognition was analyzed for 210 parents of child patients in Pusan National University Hospital from August 20 to September 15, 2013. A total of 66.2 percent of the respondents said they had participated in pediatric radiography in the past. The reason why they did is "Radiologist's request", the highest. According to the survey, 84.3 percent said they thought it is necessary to attending patient in pediatric radiography. "The stability of the child" is the reason for it. And respondents who thought there's no need to do that answered back, the reason for this is "Radiologist's work." There was a significant difference on the psychological state for the medical radiation by gender and child age. (p<0.05) In the analysis of recognition for the radiation, there was the significance by gender and education. (p<0.05) Regarding the awareness of the radiation protector, there was a statistical significance in age, gender, child age and education. (p<0.05) Considering the results, pediatric patient's guardians recognized that it is necessary to attend a child on X-ray for their child's stability and accurate exam above all. It must make guardians wear X-ray protector and radiologist should let the guardians recognize the X-ray examination method, before starting pediatric x-ray. It needs to improve the atmosphere of the examination room and to be considered to take visual and auditory approaches in comfort for reducing the children's fear and anxiety.

Characteristics of the Maximum Glow Intensity According to the Thermoluminescent Phosphors used in the Absorbed Dose Measurement of the Radiation Therapy (방사선치료 선량 측정에 사용되는 열형광체에 따른 최대 형광 강도 특성)

  • Kang, Suman;Im, Inchul;Park, Cheolwoo;Lee, Mihyeon;Lee, Jaeseung
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.181-187
    • /
    • 2014
  • The purpose of this study were to analyze the characteristic of the glow curves in order to the glow temperature of the thermoluminescent dosimeters (TLDs) for the absorbed dose measurement of the radiation therapy. In this study, we was used the TLDs of the LiF:Mg${\cdot}$Ti, LiF:Mg${\cdot}$Cu${\cdot}$P, $CaF_2$:Dy, $CaF_2$:Mn (Thermo Fisher Scientific Inc., USA). The source-to-solid dry phantom (RW3 slab, IBA Dosmetry, Germany) surface distance was set at 100 cm, and the exposure dose of 100 MU (monitor unit) was used 6- and 15-MV X-rays, and 6- and 12-MeV electron beams in the reference depth, respectively. After the radiations exposure, we were to analyze the glow curves by using the TL reader (Hashaw 3500, Thermo Fisher Scientific Inc., USA) at the fixed heating rate of $15^{\circ}C/sec$ from $50^{\circ}C$ to $260^{\circ}C$. The glow peaks, the trapping level in the captured electrons and holes combined with the emitted light, were discovered the two or three peak. When the definite increasing the temperature of the TLDs, the maximum glow peak representing the glow temperature was follow as; $LiF:Mg{\cdot}Ti$: $185.5{\pm}1.3^{\circ}C$, $LiF:Mg{\cdot}Ti$: $135.0{\pm}5.1^{\circ}C$, $CaF_2$:Dy: $144.0{\pm}1.6^{\circ}C$, $CaF_2$:Mn: $294.3{\pm}3.8^{\circ}C$, respectively. Because the glow emission probability of the captured electrons depend on the heating temperature after the exposure radiation, TLDs by applying the fixed heating rate, the accuracy of measurement will be able to improve within the absorbed dose measurement of the radiation therapy.

A Study on Accuracy and Usefulness of In-vivo Dosimetry in Proton Therapy (양성자 치료에서 생체 내 선량측정 검출기(In-vivo dosimety)의 정확성과 유용성에 관한 연구)

  • Kim, Sunyoung;Choi, Jaehyock;Won, Huisu;Hong, Joowan;Cho, Jaehwan;Lee, Sunyeob;Park, Cheolsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.171-180
    • /
    • 2014
  • In this study, the authors attempted to measure the skin dose by irradiating the actual dose on to the TLD(Thermo-Luminescence Dosimeter) and EBT3 Film used as the In-vivo dosimetry after planning the same treatment as the actual patient on a Phantom, because the erythema or dermatitis is frequently occurred on the patients' skin at the time of the proton therapy of medulloblastoma patient receiving the proton therapy. They intended to know whether there is the usefulness for the dosimetry of skin by the comparative analysis of the measured dose values with the treatment planned skin dose. The CT scan from the Brain to the Pelvis was done by placing a phantom on the CSI(Cranio-spinal irradiation) Set-up position of Medulloblastoma, and the treatment Isocenter point was aligned by using DIPS(Digital Image Positioning System) in the treatment room after planning a proton therapy. The treatment Isocenter point of 5 areas that the proton beam was entered into them, and Markers of 2 areas shown in the Phantom during CT scans, that is, in all 7 points, TLD and EBT3 Film pre-calibrated are alternatively attached, and the proton beam that the treatment was planned, was irradiated by 10 times, respectively. As a result of the comparative analysis of the average value calculated from the result values obtained by the repeated measurement of 10 times with the Skin Dose measured in the treatment planning system, the measured dose values of 6 points, except for one point that the accurate measurement was lacked due to the measurement position with a difficulty showed the distribution of the absolute dose value ${\pm}2%$ in both TLD and EBT Film. In conclusion, in this study, the clinical usefulness of the TLD and EBT3 Film for the Enterance skin dose measurement in the first proton therapy in Korea was confirmed.

A Study on Exposure to radiation of the patient who visited an emergency room at a University Hospital (한 대학병원 응급실에 방문한 환자의 방사선 피폭에 관한 연구)

  • Ahn, Buyung-Ju;Lee, Sang-Bock;Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.1 no.3
    • /
    • pp.23-34
    • /
    • 2007
  • To find how much radiation was exposed the patients who visit emergency room, a measurement study was made for radiation amount toward 200 patients selected randomly among visitors to an emergency room in a university hospital from March 16 to 31st, 2006. The results are as follows ; 1. Among the subjects 50 person(25.0%) were transferred from other hospitals, 24 persons(8.3) come after traffic accident, 50 persons for other accident and 76 persons for general medical care. 2. The average frequency of X-ray taking was calculated as 6.4 time per person among transferred patients, 14.5 times per person among patients with traffic accident and 2.6 times per person among general medical care. 3. The radiation exposure amount by kind of X-ray showed 28.9mGyfor general X-ray diagnosis, 84.2mGy for CT scanning and 1.02mGy for other special radiation study. 4. Average radiation exposure amount was calculated as 24.6mGy by transferred patients, 55.2mGy by patients with traffic accident, 17.1mGy by patients with other accidents and 17.0mGy by general patients. 5. Through the comparison of radiation exposure amount among to subject with maximum allowance threshold by International Commission on X-ray Radium Protection, transferred patients exceeded 6 times than allowance in whole body except extremities and joints, blood forming organ, reproductive system, vitreous body of eye, bone, thyroid gland, skin and etc, Patient suffered from traffic accidents were exposed 10 times more than allowance. In conclusion, the radiation exposure amount during X-rat diagnosis re too much and exceeded allowance standard by International Commission on X-ray Radium Protection. So further study and preventive measure to decrease radiation exposure by patients who visit emergency room.

  • PDF

Radioprotective Effect of Red Ginseng in Irradiated Mice with ${\gamma}$-ray (생쥐에서 홍삼의 감마선조사에 의한 방어효과)

  • Seung, Ka-Yeon;Lee, Heung-Man;Kim, Jong-Sang;Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.1
    • /
    • pp.31-35
    • /
    • 2010
  • Recently, the incidents of direct or indirect radiation exposure due to increase of use of radiation or radioisotope are on the increase in medical and industrial circles. If cells are irradiated, free radicals are created through biological process, and cells are directly or indirectly damaged. This research intends to explore into the effect of saponin at the level of cell (in vitro) and entity (in vivo), using red ginseng extract "saponin", as radioprotective agent. In the experiment implemented at the level of cell (in vitro), degree of cell activity was measures by adding mouse mesenchymal stem cells "C3H/10T1/2 cells" into red ginseng extract "saponin(0, 0.05, 0.2, and 0.4 g/L)", and then the optimal concentration of saponin influencing cells was calculated, in 24, 48, 72, and 96 hours after gamma irradiation at the optimal concentration of saponin, each cell survival rate was observed through XTT assay. The best time period of cultivation for the optimal activity of C3H/10T1/2 cells was as 48 hours, and the degree of optimal activity was shown at 0.05 g/L. In 48 hours after irradiation of 5 Gy to C3H/10T1/2 cells at 0.05 g/L, the degree of activity of cells increased by 10%. In the experiment implemented at the level of entity (in vivo), red ginseng extract "saponin" at a dose of 100 mg/kg/day was injected into the abdominal cavity of six-week immature mouse for two weeks. Right after the last abdominal injection, total body irradiation of gamma rays was carried out at a dose of 5 Gy and 10 Gy. And after irradiation, the blood sample was taken, and then the number of red corpuscles was counted. In result, the decrement of experimental group treated with red ginseng extract "saponin" was 2.3 times larger than that of control group. In view of the results so far achieved, it was revealed that red ginseng extract "saponin" has a radiation exposure protection effect in the experiment implemented at the level of cell (in vitro). In case of animal experiment, the decrement of number of red corpuscles decreased. Finally, it is necessary to carry out more various researches continuously.