• Title/Summary/Keyword: 노후터널

Search Result 32, Processing Time 0.027 seconds

Evaluation of Railway Line Segment Deterioration Using AHP and DEA (AHP와 DEA를 활용한 철도선로구간 노후도 평가)

  • Kim, Seongho;Choi, Chan-Yong;Na, Hee-Seung
    • Journal of the Korean Society for Railway
    • /
    • v.16 no.2
    • /
    • pp.117-121
    • /
    • 2013
  • Railway line segment deterioration can be affected by rail tracks, subgrades, bridges, tunnels, and line shapes. In this paper, an evaluation method is presented for the railway line segment deterioration using the analytic hierarchy process (AHP) and data envelopment analysis (DEA). The importance weights can be assessed systematically for component facilities from numerous experts using AHP. The importance weights provided by experts may differ according to each expert; however, the DEA enables the evaluation of railway line segment deterioration that reflects the variety of expert opinions using these importance weights.

Security Interpretation of the Restriction Boundary of Building for Antiquated Tunnel using 3 Dimensional Surveying (3차원 측량에 의한 노후 터널의 건축한계 확보 해석)

  • Bae Sang-Ho;Lee Hyung-Seok
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.24 no.3
    • /
    • pp.251-259
    • /
    • 2006
  • For the electrification of the existing railways, the security of the restriction boundary of building with mechanistic stability research on the antiquated tunnel must be accomplished essentially. If the tunnel don't secure its restriction boundary of building, the reconstruction based on improvement of tunnel alignment are generated and its surveying data are required. The precise surveying was conducted with the same coordinate system for three tunnels of Youngdong tramline, and the restriction boundary of building of the straight and curve section were analyzed effectively by acquiring the data of profile and cross section, profile rail-height, rail-grade, cross tunnel height, and restriction boundary of building. This study is presented for valuation data of the stability of the electrification design to construct and analyze restriction boundary of building, which compared with the drawing and its existing design using profile and cross section. After this, it is interoperable to increase the development of real-time monitoring system on the tunnel structures.

A Case Study on Construction of Long Tunnel in the Youngdong Railroad(Mt. Dongbaek - Dokye) (영동선 동백산-도계간 장대터널 시공사례)

  • 김용일;윤영훈;조상국;양종화;이내용
    • Proceedings of the KSR Conference
    • /
    • 2002.05a
    • /
    • pp.189-199
    • /
    • 2002
  • 영동선 이설사업 일환으로 영동선 동백산역(강원도 태백시 연화동)과 도계역(삼척시 도계읍)간의 본 터널은 총 연장 16.4km인 장대터널로서 전북 완주 전라선 슬치터널(6.12km)보다 10km 이상 길고, 정선 고한과 태백 추전을 잇는 4.5km의 정암터널의 3배가 넘는다. 특히 이 터널은 구간의 높이 차(약 3백80m)를 극복하기 위해 Loop형태로 설계되었고, 열차의 안정성, 구난대피, 환기측면에서 단선병렬 터널로 설계되었다. 또한 불량한 선형과 노후된 터널구조물로 인한 열차 안전운행 저해요인을 해소하기 위해 천공발파공법을 굴착공법으로 채택하였다. (중략)

  • PDF

Analysis on the behavior of a old tunnel supporting system by enlargement (노후터널 확대시 기존터널 지보재 응력 변화에 대한 분석)

  • Baek, Ki-Hyun;Kim, Woong-Ku;Seo, Kyoung-Won
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.1382-1387
    • /
    • 2010
  • A 3D FEM numerical analysis was performed to observe the changes of supporting system of a old 1-lane tunnel when it is enlarged to 2-lane, 3-lane and 4-lane. The standard Type-III supporting pattern was applied to the new tunnel because the ground was assumed as Type-III. The observation was carried out at the middle supporting system of the old 1-lane tunnel alignment. The results shows that the changes of old tunnel supporting system began when the new tunnel was excavated at 2D(D is the equivalent diameter of 1-lane tunnel) behind of the observation place and became very rapid from 1D.

  • PDF

A Case Study of Spillway Design of Soyanggang Dam (소양강댐 보조여수로 설계 사례 소개)

  • Han, Byeong-Hyeon;Yun, Su-Ho;Kim, Tae-Hyeok;Lee, Jung-U;Lee, Myeong-Seop
    • Magazine of the Korean Society of Hazard Mitigation
    • /
    • v.6 no.2 s.21
    • /
    • pp.52-70
    • /
    • 2006
  • 최근 잦은 기상이변과 대규모 태풍(2002년 루사, 2003년 매미 등)에 의해 기존 댐의 안정성이 미흡한 것으로 판단됨에 따라 최대가능홍수량(PMF) 유입시 소양강 댐의 수문학적 안정성 확보와 용수공급량 및 발전용량의 확보, 댐 주변 노후시설의 자연 친화적 개보수에 의한 친환경적 공간창출과 이로 인한 관광 수요 증대에 따른 지역경제 활성화를 목적으로 기존 여수로에 추가하여 보조여수로가 계획되었다. 보조여수로는 수리적 특성, 지반조건, 인문사회적 여건 및 문화재 등 기타 기반여건을 감안하여 1,276.4m와 1,206.4m, 2련 14도 완경사 터널식 여수로로 설계되었으며 터널은 폭 $14{\sim}25m$의 대단면으로 계획되었다. 보조여수로는 유입부 및 유출부 구조물, 천이부터널 및 일반터널, 개착터널로 계획되었으며 각 구조물의 수문학적 안정성을 바탕으로 설계되었다.

  • PDF

Bond Characteristics of Scale According to the Drainage Pipe's Material in Tunnel (터널 배수공의 재질에 따른 스케일 부착 특성에 관한 연구)

  • Chu, Ickchan;Nam, Seunghyuk;Baek, Seungin;Jung, Hyuksang;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.11
    • /
    • pp.51-57
    • /
    • 2011
  • The calcium hydroxide($Ca(OH)_{2}$) which is flowed into the deteriorated tunnel by groundwater is reacted with carbon dioxide($CO_{2}$) and the vehicle's exhaust gas ($SO_{3}$). So its by-products are precipitated at the drainage pipe and these cause the drainage clogging. Most by-products are composed of $CaCO_{3}$ with calcite from a chemical experiment. The purpose of this study is mainly focused on comparison of attachment on each material of drainage pipe (teflon-coated steel pipe, silicon-Oil coated pipe, acrylic pipe and PVC pipe). The test was progressed to disembogue the CaO aqueous solution and tunnel outflow into each of the pipes. The experimental results show that the most produced scale pipe is PVC material and the followings are Acrylic pipe, Silicon-Oil coating pipe and Teflon coating pipe. But the long-term test results showed that teflon-coated steel pipe had a problem with durability because soil which was contained in the tunnel outflow occurred detachment of coating and corrosion of the steel pipe.

Economical aessesment of long tunnel route complex geological formations (복잡한 지질구조암반층에서의 장대터널노선 선정을 위한 경제성 평가에 대한 연구)

  • Kim, Sang-Hwan;Park, Inn-Joon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.7 no.3
    • /
    • pp.239-247
    • /
    • 2005
  • A new railway line of about 17km length was planned between Dongbaeksan and the neighboring town Dokye to improve the existing decrepit railway system. New line about 17km of the distance will almost be in circular alignment tunnels owing to the difference of elevation about 380m. Since the geology of the area is rather unusual compared to the normal in South Korea, extensive geological investigations have been carried out to prepare geological maps and profiles along the planned tunnel routes. The tunnel will almost be in sedimentary rock formations, such as limestone, sandstone, shale, coal etc and be near abandoned mines Various rock formations have the complicated, alter ed those rocks, but are well developed with laminated formations. Each rock formations have been classified using the Q-system and the cost of tunnel excavation, support has been estimated and compared for three alternative routes in the design stage. Based on these estimates, the final route of t he railway line was chosen.

  • PDF

The Anti-scale Effect according to Array of Magnetic Device (자화장치의 배열별 스케일 생성 억제 효과)

  • Nam, Joongwoo;Han, Yunsu;Lee, Jonghwi;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.2
    • /
    • pp.13-17
    • /
    • 2013
  • Clogging phenomenon in drainage system is one of the important problems and this phenomenon would be bad effect to structure of tunnel, so it needs a remedy urgently. Recently, scale in drainage pipe is removed by water jet cleaning and other treatment. But these treatments need much cost and regular management. In this study, magnetic device was used to solve this problem and an effect of prohibiting scale in accordance with array of magnetic device was investigated. Analysis method was visual analysis and measuring weight of each pipes. As a result, interior top and out-bottom (CASE II) was the most effective array to prohibit scale. and interior left and right (CASE III), interior top and bottom (CASE I) was effective for prohibiting scale in order.

The numerical study on the ground settlement behavior of box type tunnel enlargement (2차원 수치해석을 통한 초저심도 박스형 터널 편측확폭시 지반침하거동 특성 분석)

  • Cha, Yohan;Cho, Gye-Chun;Hong, Eun-soo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.18 no.1
    • /
    • pp.83-94
    • /
    • 2016
  • Utility tunnels have been employed in Korea since the 1970s and start to make trouble with structural safety and serviceability. Recently, tunnel enlargement has consequently been proposed due to the impending problems. However there are little study on box type utility tunnels except traffic tunnels. A 2D finite element analysis was conducted to evaluate ground behavior which depends on enlargement size and stiffness by one-side enlargement of the utility tunnel. Settlement scale increased with larger enlargement size and less stiff ground conditions. The observed settlement characteristics due to enlargement are similar to that suggested by Clough & Schmidt (1981). The settlement width is more affected by enlargement size than ground condition.

Damage Detection of Decrepit Tunnel Structures using the NDT (비파괴 검사법에 의한 노후터널의 건전도 평가)

  • Kim, Dong-Gyou;Jung, Ho-Seop
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.1388-1391
    • /
    • 2010
  • Recently, the construction of road, subway, railroad, and microtunnel for electricity supplement have been increased because of increasement of traffic in urban area, increasement of industrial transportation, and the network between cities in Korea. The deterioration of tunnel structure may occur by various internal and external factors and particularly, tunnel structures tend to contact with either underground water or harmful ions. Therefore, leakage sometimes occurred through the cracks and joints of concrete lining. The leakage in tunnel may affect the durability of concrete lining. In this study, to evaluate the durability and deterioration of concrete lining in tunnel structures, we were performed the various experiments for compressive strength. Compressive strength obtained from nondestructive inspection and compressive strength test varies according to the concrete lining conditions.

  • PDF