• Title/Summary/Keyword: 노후상황

Search Result 94, Processing Time 0.033 seconds

A Study on Pattern Language of Cultural Urban Regeneration -Focused on Henan-Sung of China- (문화적 도시재생을 위한 패턴언어 개발연구 -중국 하남성(河南城)을 중심으로-)

  • Fan, Dan Dan;Kim, Se-Hwa
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.6
    • /
    • pp.192-203
    • /
    • 2019
  • China's urban regeneration, which has been focused on economic growth since the 1950's, has brought about the uniformity of cities. In order to improve on this, the urban regeneration policy has been transformed into a cultural city resource, which is promoting urban regeneration while utilizing the cultural characteristics of each region. However, the specific application methods are still lacking. In this study, I attempt to modify the apartment environment of the city, Hanan-sung, based on the pattern-language of Christopher Alexander, a space planning tool that can be used in urban regeneration. First, 23 patterns were chosen from the primary pattern-language. Next, I investigated the characteristics of the traditional housing culture of Hanan-sung through the literature review, surveyed the opinions of current apartment residents, and summarized the requirements. Finally, a new pattern-language was developed for the regeneration of the old apartments from the viewpoint of the culture, by modifying it according to the characteristics and requirements of housing culture of Hanan-sung which summarizes 23 pattern-languages.

Detection of turbid water generated pipe through back tracing calculation method in water distribution system (상수관망에서 역추적 계산법을 이용한 탁수 발생관 탐지)

  • Kwon, Hyuk Jae;Kim, Hyeong Gi;Han, Jin Woo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.482-482
    • /
    • 2023
  • 상수도관은 사용년수가 경과함에 따라 노후화가 진행되며, 노후화된 상수관은 내부적으로 부식, 이물질 퇴적, 균열 등의 현상이 발생하게 되고, 이는 결국 수질문제로 연결되어, 탁수사고 발생 확률증가의 주요 원인이 되고 있다. 국내 상수도관의 경우 매설년수의 증가로 인해 내구연한이 도래한 상수관망의 비중이 점차 증가하고 있으며, 2019년 서울시 문래동 수질사고, 2019년 인천 붉은 수돗물 사고, 2022년 안양 동안구 탁수사고, 2022년 여수시 웅천 탁수사고 등 관의 노후화로인한 탁수 사고가 빈번하게 발생되고 있어 수도 사용자에게 불편함을 끼치고 있다. 현재 정수장 및 상수관망에 설치된 탁도계를 통해 수질에 대한 감시를 진행하고 있지만, 경제적인 문제로 인해 모든 상수도관에 탁도계를 설치하기에는 현실적으로 불가능하며, 제한적인 탁도계의 개수를 통해 수질에 대한 감시 및 관리를 진행하고 있는 실정이다. 이러한 상황으로 인해 탁수사고 발생 시 발생 원인분석 및 최초 발생위치 결정이 쉽지 않으며, 보수 보강을 통한 상수도관의 정상화까지 오랜 시간이 걸리게 된다. 이에 본 연구에서는 상수관망에서 탁수 발생 시 최초 발생 위치를 결정할 수 있는 기법을 개발하였으며, 이를 실제 상수도관망에 적용하여 탁수발생 파이프를 탐지하였다. 탁수사고 발생 시 실측된 수질 데이터의 부족으로 인해 임의의 파이프에서 탁수가 발생하였다고 가상의 탁수 발생시나리오를 가정하였으며, 완전혼합농도식을 통해 관망에 설치된 탁도계의 NTU(Nethelometric Paultity Unit) 농도를 계산하여 가상의 탁수발생 시나리오를 상수도관망에 적용하였다. 이후, 역추적 계산기법을 통해 파이프의 초기 NTU 농도를 변화시켜주며 관망내 설치된 탁도계의 NTU 농도를 계산하였으며, 가상 시나리오를 적용하여 계산된 탁도계의 NTU 농도와 역추적 계산법을 적용하여 계산된 탁도계의 NTU 농도의 Percentage Error를 비교/분석하여 탁수 발생 파이프를 탐지하였다. 분석결과, 가상 시나리오의 최초 탁수발생 파이프와 역추적 계산법을 적용하여 탐지한 최초 탁수발생 파이프의 위치가 일치하는 것으로 나타났다. 본 연구에서 개발된 역추적계산을 통한 탁수발생 파이프 탐지기법을 실제 관로 교체사업에 활용한다면 파이프의 개선 우선순위를 보다 명확하게 판단할 수 있으며, 더 나아가 상수도 관망의 유지관리에 활용하여 경제적이고 효율적인 상수관망 시스템관리를 할 수 있을 것으로 판단된다.

  • PDF

A Study on the Procedure for Applying Digital Twin to Disaster and Aging Management of Port Infrastructure (항만 인프라 재해와 노후화 관리를 위한 디지털 트윈 적용 절차에 관한 연구)

  • Hye-Jung Chang
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.16 no.3
    • /
    • pp.138-151
    • /
    • 2023
  • Korea's port infrastructure is rapidly aging, with old port facilities with more than 30 years of public life expected to surge from about 23% in 2019 to 47% in 2029. Traditional, aging ports lose competitiveness in logistics processing, reducing development around the port and increasing human casualties due to the human resource-based maintenance of the facilities. Therefore, it is necessary to solve this problem by establishing systematic management technology based on a digital twin. This research aimed to present the specific implementation steps of a digital twin reflecting smart port technology through cases of port infrastructure disasters, aging status, and smart ports. The study analyzed the port infrastructure linkage system and created and mapped scenarios essential for digital twin implementation. Three-dimensional (3D) modeling and simulation data for disaster and aging management among existing port infrastructure systems were collected. A digital twin port was implemented with 3D modeling. It implements a port digital twin simulation that links data such as sensing data and image data acquired from the port infrastructure in real time. Implementing a digital twin port for port infrastructure disasters and aging management can secure predictive port infrastructure management and disaster safety

A Study on Exploring Urban Renewal Areas Using Spatial Density Analysis (공간 밀도분석을 이용한 재정비 대상지 탐색에 관한 연구)

  • Kijung Kim;Seungwook Go;Jinuk Sung
    • Land and Housing Review
    • /
    • v.14 no.2
    • /
    • pp.35-50
    • /
    • 2023
  • The purpose of this study is to identify areas in need of urban renewal by utilizing spatial data and analyzing their types and characteristics. For this, this research employed a kernel density function and K-means cluster analysis with spatial data, through which it sought ways to identify high-demand areas for urban renewal projects. The key findings and implications of the research are summarized as follows. Firstly, this research classified 587 target sites in Seoul based on development density (ratios) and an indicator for aged buildings. Approximately half of these areas were consistent with leading pilot project sites and Accelerated Integration Sites. Secondly, it was observed that residential environments in the designated leading pilot project sites, as decided by public sectors, were relatively poor compared to other areas. Lastly, the target areas for urban renewal were not clearly categorized through statistical analysis. Instead, it was found that categorization should be made depending on the requirements of each project.

Efficient Integrated Real-time Discharge Measurement System Operating Strategy applying Non-face-to-face technology (비대면 기술을 적용한 효율적인 자동유량측정시스템 운영 방안)

  • Oh, Dong Heon;Baek, Jong Seok;Cho, Sang Uk;Cha, Jun Ho;Seo, Hae Yeop
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.482-482
    • /
    • 2021
  • 자동유량측정시스템은 하천 유량을 실시간으로 측정하기 위한 수문조사시설로 전국 하천 64개 주요 지점에 설치·운영 중이며 실시간으로 운영되는 시스템의 특성상 내·외부 요인으로 인해 자료의 결측이 발생할 수 있다. 주요 결측 요인으로는 계측장비의 고장 및 오작동, 낙뢰로 인한 전원부문제, 시스템 컨트롤러 단순 오류 등이며, 현재 이로 인해 결측이 발생한 경우 현장 방문을 통한 조치 외에는 복구가 불가한 실정이다. 본 연구에서는 현장 유지관리 개선을 통해 자료 결측 최소화 방안을 마련하고자 최근 5년간(2015년~2019년) 수행된 유지관리 점검내역을 검토하였다. 현장 유지관리는 정기적으로 수행되는 정기점검, 수중점검과 장애 발생 시 수행되는 현장점검으로 구분되며 최근 5년간 수행된 점검(1,735회) 중 정기적인 점검을 제외한 현장점검의 경우 총 764회(46%) 수행된 것으로 나타났으며 현장점검 중 유지관리 방법 및 장비 개선 적용 사례를 통해 최소 1일~3일 소요되던 점검 시간이 즉시 조치가 가능한 것으로 나타났다. 시스템 확대 및 기존 장비의 노후로 현장점검은 지속적으로 증가하고 있으며 최근 사회적 상황을 고려하였을 때 사물인터넷(IoT)을 활용한 시설물 개선 등으로 비대면 점검 수행이 가능해짐에 따라 점검 소요시간을 단축하여 보다 효율적인 시설물 운영, 예산 절감, 자료의 연속성 확보 등이 가능할 것으로 판단된다.

  • PDF

A Study on the External Evacuation System for Large-scale Fire of Multi-use Facilities (다중밀집시설 대형화재 외부대피 체계에 관한 연구)

  • Kim, Jung-Gon;Jeong, Min-Su;Jung, Jae-Wook
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.1
    • /
    • pp.129-145
    • /
    • 2022
  • Purpose: This study aims at preparing an external evacuation system by setting up situation that may occur outside buildings in case of large-scale fire at buildings such as multiuse facilities and presenting appropriate response procedures and action instructions for evacuees and facility managers. Method: Major matters are summarized based on various situations which may occur outside in case of fire and the contents of fire manual. Necessary factors including risk alert standards in the event of fire and the role of building occupants are classified and then important issues are summarized. In addition, the definition of fire-related outside shelters and external evacuation routes are showed, and then the applicability to the shelters and the routes are reviewed for old apartments in Jung-gu among multi-dense facilities. Result: Four stages (attention, caution, alert, serious) for standards of fire risk warning are established with the results of the investigation and analysis, and guidelines for behavior for evacuees, facility owners, residents, managers are summarized and presented. In addition, the concept and role of external shelters are divided into primary to the third shelters, and matters related to the definition of each shelter and the establishment of evacuation routes are presented, and then considered them carefully. Conclusion: This study has highlighted the importance of suggesting a systematic plan to secure the safety for evacuees outside space of buildings with disorder and difficulty to control in the event of fire. Therefore, we are confident that it will be useful in making an integrated manual for inside and outside buildings.

Green Port Strategies for Reducing Air Pollution in Port of Incheon (대기오염 저감을 통한 인천항의 Green Port 전략)

  • Han, Chul-Hwan
    • Journal of Korea Port Economic Association
    • /
    • v.27 no.1
    • /
    • pp.281-304
    • /
    • 2011
  • In the energy-climate era, pollution emissions from port activities have a significant issue in international shipping and port community. Thus international organization such as IMO and developed countries are seeking to develop various reduction strategies against air pollution. However Korea has recently conducted several studies concerning air pollution in port industry. The main purpose of the paper is to suggest emission reduction strategies for bulk terminal in Port of Incheon, which handles large amount bulk cargoes as a gateway for the metropolitan area. For this aim, the clean air strategies of the world major ports were considered and air pollution reduction strategies were suggested. The main findings of this paper are as follows. First, the emission reduction strategies for container terminal are should be integrated based on technologies changes, operational changes and market-based measures. Second, the emission reduction strategies for bulk terminal can be effective when use innovative measures during loading, unloading and storage process such as telescopic cascade trimming chute, snake sandwich equipment, dry fog system and dome structure. Finally, investigation on actual conditions of air pollution in Korean ports and development of environmental evaluation scheme for persisting monitoring should be conducted.

Development of DL-MCS Hybrid Expert System for Automatic Estimation of Apartment Remodeling (공동주택 리모델링 자동견적을 위한 DL-MCS Hybrid Expert System 개발)

  • Kim, Jun;Cha, Heesung
    • Korean Journal of Construction Engineering and Management
    • /
    • v.21 no.6
    • /
    • pp.113-124
    • /
    • 2020
  • Social movements to improve the performance of buildings through remodeling of aging apartment houses are being captured. To this end, the remodeling construction cost analysis, structural analysis, and political institutional review have been conducted to suggest ways to activate the remodeling. However, although the method of analyzing construction cost for remodeling apartment houses is currently being proposed for research purposes, there are limitations in practical application possibilities. Specifically, In order to be used practically, it is applicable to cases that have already been completed or in progress, but cases that will occur in the future are also used for construction cost analysis, so the sustainability of the analysis method is lacking. For the purpose of this, we would like to suggest an automated estimating method. For the sustainability of construction cost estimates, Deep-Learning was introduced in the estimating procedure. Specifically, a method for automatically finding the relationship between design elements, work types, and cost increase factors that can occur in apartment remodeling was presented. In addition, Monte Carlo Simulation was included in the estimation procedure to compensate for the lack of uncertainty, which is the inherent limitation of the Deep Learning-based estimation. In order to present higher accuracy as cases are accumulated, a method of calculating higher accuracy by comparing the estimate result with the existing accumulated data was also suggested. In order to validate the sustainability of the automated estimates proposed in this study, 13 cases of learning procedures and an additional 2 cases of cumulative procedures were performed. As a result, a new construction cost estimating procedure was automatically presented that reflects the characteristics of the two additional projects. In this study, the method of estimate estimate was used using 15 cases, If the cases are accumulated and reflected, the effect of this study is expected to increase.

Performance Evaluation of Recycled Aggregate Concrete Made of Recycled Aggregate Modified by Carbonation (탄산화 개질 순환 골재를 사용한 순환 골재 콘크리트의 성능 평가)

  • Ha, Jung-Soo;Shin, Jin-Hak;Chung, Lan;Kim, Han-Sic
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.4
    • /
    • pp.445-454
    • /
    • 2016
  • With the increase of decrepit facilities, construction waste increased to a certain level and now the increase is more or less stabilized. Yet construction waste still constitutes the largest portion of the overall wastes. Also, it is inevitable to spend a huge amount of the national budget due to the aggravating shortage of aggregate caused by prohibition on collection of natural aggregates as well as due to the damage to the land and environment caused by development of the sources of aggregates. As a countermeasure to the situation, the Ministry of Land, Infrastructure and Transport promulgated the quality standard for recycled aggregate to manage the usage of recycled aggregate according to its quality. But use of recycled aggregate for the purpose of high added value still remains nominal. Therefore, this research aims to study the applicability of recycled aggregate concrete as structural concrete by evaluating the quality improvement effects and the performance of the recycled aggregate concrete including recycled fine aggregate and recycled coarse aggregate that have undergone carbonation for 4 days and 14 days respectively in the condition of 60% RH, 20% $CO_2$ and $20^{\circ}C$ temperature, suggested for carbonation modifying from the advance research. The result shows carbonation modify contributed to quality improvement with 0.91% decrease in absorption rate for recycled fine aggregate and 0.7% decrease in absorption rate for recycled coarse aggregate. The physical properties and durability of the recycled aggregate made of aggregate modified by carbonation showed results similar to general concrete, which confirmed the possibility of applying the recycled aggregate made of recycled aggregate modified by carbonation to structural concrete.

EVALUATION OF THERMAL DIFFUSION IN LOWER End PRIMARY MOLAR WITH THERMOGRAPHY AND FINITE ELEMENT ANALYSIS (Thermography와 유한요소분석법을 이용한 하악 제2유구치의 열확산도 평가)

  • Park, Hee-Seung;Kim, Yong-Kee;Kwon, Soon-Won;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.4
    • /
    • pp.519-528
    • /
    • 2002
  • It is not a rare occasion that certain dental procedures involving tooth reduction being peformed under inadequate water cooling due to a variety of reasons. This situation could possibly inflict the critical insult to the pulpal tissue of indicated tooth. The purpose of this experiment was to study the pattern of diffusion of external heat produced during routine dental procedures into the pulpal tissue. 30 stone blocks containing three lower second primary molars were used for certain restorative procedures and the temperature of the indicated tooth surface was measured by thermography(Inframetrics 600) and further used as a baseline data for the finite element analysis model fabrication designed in order to evaluate the pattern of thermal diffusion. The ranges of highest surface temperature measured from several dental procedures under water cooling and non-water cooling were $30.8^{\circ}C{\sim}43.6^{\circ}C$ and $51.2^{\circ}C{\sim}103.4^{\circ}C$ respectively. Among procedures studied, crown preparation showed the highest value and amalgam removal showed the lowest. Comparisons between data measured under water cooling and non-water cooling conditions have shown the statistically significant difference(p<0.05). All the non-cooling conditions have shown the relatively larger increment of temperature change at the pulp horn area than the cooling conditions. The results of this study strongly indicate that the water coolant is the essential element in restorative procedures for the maintenance of healthy pulp. Further related studies involving more procedures and conditions are recommended.

  • PDF