• Title/Summary/Keyword: 노출제어

Search Result 444, Processing Time 0.03 seconds

Studies on the Antibacterial Effects of Electrolyzed Reduced Water (환원전리수의 항균력 연구)

  • Park, Hye-Lin;Kim, Yoon-Kyoung;Ryoo, Kun-Kul;Lee, Yoon-Bae;Lee, Jong-Kwon;Lee, Mi-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.6 no.2
    • /
    • pp.215-221
    • /
    • 2005
  • The antibacterial effects of electrolyzed reduced water on the bacterial growth were studied in this investigation. Upon treating with electrolyzed reduced water for 2 minutes, about 70% Escherichia coli and 61% Bacillus cereus were controlled. When these two bacteria were exposed to electrolyzed reduced water for 30 minutes, about 89% Escherichia coli and 94% Bacillus cereus were controlled. About 55% Pseudomonas aeruginosa was also controlled upon treateing with electrolyzed reduced water for 2 minutes, and 65% Pseudomonas aeruginosa was controlled during 4 hour incubation. When Staphylococcus epidermidis was treated with electrolyzed reduced water for 4 hours, 73% of the bacterial growth was inhibited, while only 44% Staphylococcus aureus.subsp.aureus was controlled with electrolyzed reduced water for 4 hours.

  • PDF

Implementation of color CCD Camera using DSP(GCB4101) (디지털 신호처리 칩(GCD4101)을 사용한 컬러 CCD 카메라 구현)

  • Kwon, O-Sang;Lee, Eung-Hyuk;Min, Hong-Ki;Chung, Jung-Seok;Hong, Seung-Hong
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.1
    • /
    • pp.69-79
    • /
    • 1999
  • The research and implementation was preformed on high-resolution CCTV camera with CCD exclusive DSP conventional analog signal processor CCTV camera has its limit on auto exposure(AE), auto white balance(AWB), back light compensation(BLC) processing, severe distortion and noise of image, manual control parameter setting, etc. In our study, to resolve the problems in conventional CCTV camera, we made it possible to control AE, AWB, BLC automatically by the use of the DSP, which are used exclusively in the CCD camera produced domestically, and the microcontroller. And we utilized the function of screen display of microcontroller for the user-friendly interface to control CCD camera. And the electronic variable resister(EVR) was used to avoid setting parameters manually in the level of manufacturing process. As the result, It became possible to control parameters of the camera by program. And the cost-down effect was accomplished by improving the reliability of parameter values and reducing the efforts in setting parameters.

  • PDF

A Study on the Using of Automatic Exposure Control in the Chest Radiography (흉부 방사선검사에서 자동노출제어 사용에 관한 연구)

  • Choi, Sung-Sik;Lim, Cheong-Hwan;Jung, Sung-Hoon
    • Journal of radiological science and technology
    • /
    • v.42 no.1
    • /
    • pp.19-24
    • /
    • 2019
  • For general radiological examinations, even in the same area and the same test, the test conditions must be set differently according to the patient. However, since it is impossible to consider the body shape and conditions of patients every time in medical institutions where various patients visit, the tests are conducted by setting the AEC which automatically sets the test conditions. AEC is most commonly used in chest radiography. Therefore, the purpose of this study is to propose the improvement plans for using AEC by measuring the exposure dose and evaluating the image quality according to whether the AEC is used or not, and to provide basic data for AEC research. In the present study, images were acquired while varying tube voltage and test distance according to the use of AEC in chest radiography. The radiation dose was measured by placing the dosimeter in front of the chest phantom, and the CNR and SNR of acquired images were analyzed using Image J. The t-test was conducted for the statistical analysis and the significance was determined at the level of 95%(p<.05). As a result of this study, in the inspection distance (100cm, 140cm, 180cm) according to the use of AEC, high doses were observed when the AEC was used and there was statistically significant difference(p<.05). In the t-test to determine the difference between CNR and SNR depending on whether AEC was used or not, there was no significant difference according to the use of AEC(p>.05). Therefore, when performing chest radiography, if the radiologist establishes the appropriate examination conditions and conducts the examination by not just relying solely on AEC, it may be possible to reduce unnecessary radiation exposure to the patient.

Effects of Exposure Dose Reduction by Optimization of Automatic Exposure Control Factors in Digital Radiographic Examination of Paranasal Sinus (부비동 디지털 엑스선검사에서 자동노출제어 조절인자의 최적화를 통한 조사선량 감소 효과)

  • Jeong, Min-Gyu;Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.44 no.3
    • /
    • pp.173-181
    • /
    • 2021
  • The purpose of this study was to reduce dose while maintaining image quality during digital radiographic examination of paranasal sinus by using the automatic exposure control (AEC) system. The tube voltage was set as six stages that increased by about 10 kVp to 70 kVp, 81 kVp, 90 kVp, 102 kVp, 109 kVp and 117 kVp. And then the AEC system conditions were consisted of 9 setting environments, that change mode of the sensitivity (S200, S400, S800) and the density (+2.5, 0, -2.5). We measured automatically exposed tube current (mAs) under 54 conditions with combined these, and assessed SNR and PSNR through the acquired images. In addition, four radiologists performed a qualitative assessment of the acquired images for each combination on a five-point scale of the Likert. As a result, the lowest dose and the highest values of SNR and PSNR in images with a qualitative assessment more than 4 point were the AEC control factors of 90 kVp, S800, D2.5. We applied this condition to the clinical trial, it showed an effect of 83.1% reduction in exposure radiation dose (mR). Therefore, AEC system could be used as dose reduction technology if it understood and used related regulatory factors and physical characteristics.

Correlation Analysis of Control Factors in Automatic Exposure Control of Digital Radiography System Based on Fine Contrast Images (미세 대조도 영상을 기반한 디지털 방사선 영상 시스템의 자동노출제어 조절인자 간의 상관관계 분석)

  • Lim, Se-Hun;Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.44 no.1
    • /
    • pp.1-8
    • /
    • 2021
  • The purpose of this study was to analyze the effect of automatic exposure control (AEC) control factors in digital radiography systems based on the fine contrast images using coin phantoms. The AEC control factors were targeted at the range of dominent zone, sensitivity, and density. The dominent zone was divided into cases where a single coin was used to cover the field configuration, and cases where seven coins were used to cover the field configuration. The sensitivity was classified into three stages (200, 400, 800) and the density was classified into three stages (2.5, 0, 2.5). Image quality was evaluated by signal to noise ratio (SNR) and contrast to noise ratio (CNR). Then, the automatically exposed tube current was measured. As a result, the X-ray image of seven coins obtained a result value of about 1.2 times higher for SNR and 1.9 times higher for CNR than the X-ray image for one coin. The tube current was also about 1.6 times higher. In conclusion, In AEC, the higher the field configuration and dominent zone are matched and the higher the density, the lower the sensitivity, which increases the tube current and CNR, which increases the image quality. Therefore, it is judged that the appropriate setting of the range of dominent zone, sensitivity, and density of the control, which is the AEC control factor, could improve the fine contrast of images.

Automatic Exposure Control Performance Evaluation of Digital Radiographic Imaging System by Manufacturer Using Coins (동전을 이용한 제조사 별 디지털 방사선 영상 시스템의 자동노출제어 성능 평가)

  • Lim, Se-Hun;Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.45 no.1
    • /
    • pp.1-9
    • /
    • 2022
  • In this study, we proposed an image quality control for an automatic exposure control (AEC) of digital radiographic imaging system and tried to analyze the performance of the AEC by various manufacturer. The subjects of the experiment were analyzed for the AEC image quality evaluation using digital radiation generators from four manufacturer such as PHILIPS, GE Healthcare, SAMSUNG Healthcare, DK Medical Solution. We used as materials for the implementation of the image quality evaluation by coins (500 won, KOMSCO, Korea). This study evaluated the performance evaluation of the AEC as image quality and exposure dose (Milliampere-seconds; mAs). The image quality evaluation was tried visual assessment by two radiologic technologists and contrast to noise (CNR) by ImageJ. The exposure dose investigated mAs on digital radiation generators. The radiographic coin images acquired 360 images based on change in the control factors of the AEC, which were kVp, the consistency of field configuration and dominant zone, sensitivity and density. As a result, there was a significant difference in the AEC performance between manufacturer. The CNR by the AEC for each manufacturer showed a difference of up to about 1.9 times. The exposed tube current by the AEC for each manufacturer showed a difference of up to about 5.8 times. It is expected that our proposed evaluation method using coins could be applied as the AEC performance evaluation method in the future.

Performance Improvement of Channel Access Control Method in Wireless Mesh Networks (무선 메쉬 네트워크에서 성능향상을 위한 채널접속 제어 방법)

  • Lee, Soon-Sik;Yun, Sang-Man;Lee, Sang-Wook;Jeon, Seong-Geun;Kim, Eung-Soo;Lee, Woo-Jae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.3
    • /
    • pp.572-580
    • /
    • 2010
  • The Wireless Mesh Network uses a wireless communication technology with transmission rates simular to a cable which is used as a backbone networks. The topology structure is in a Mesh form which resembles an Ad-hoc networks. However, a metric is needed in order to set the channel access control method to operate intentions and interior motions are different. In this document, an efficient channel for delivering datas to improve access controls to a wireless mesh networks. The improved performance of the proposed plan is for a hidden and exposed mesh client through an exclusive channels to perform a proposed and analyzed methods.

Design and Implementation of File Access Control Module for Secure Operating System Using on Windows (윈도우 기반의 보안 운영체제를 위한 와일 접근 제어 모듈 설계 및 구현)

  • 한석재;김완경;소우영
    • Proceedings of the Korea Information Assurance Society Conference
    • /
    • 2004.05a
    • /
    • pp.131-137
    • /
    • 2004
  • With the rapid development of information sharing through network, If system is exposed to various threatener and security incident are became a social problem. As a countermeasure, various security systems are been using such as IDS, Firewall, VPN etc.. But, expertise or expert is required to handle security system. In this paper, design and implementation of file access control module for secure operation system. The module, implemented in this paper, is based on Windows and has effect integrity and non-repudiation for a file.

  • PDF

Information flow control using spatial view with multilevel security (다단계 보안을 갖는 공간 뷰를 이용한 정보 흐름 제어)

  • Jun, Young-Sub;Oh, Young-Hwan;Lee, Soon-Jo;Rim, Ki-Wook;Bae, Hae-Young
    • Annual Conference of KIPS
    • /
    • 2001.04a
    • /
    • pp.93-96
    • /
    • 2001
  • 공간 데이터베이스에서는 공간 객체에 대해 객체마다 서로 다른 보안 등급을 설정함으로써 공간 객체에 대한 보안을 유지하고 있다. 다단계 보안을 사용하여 사용자의 보안 등급에 따라 공간 객체에 대한 접근을 제어할 경우 인접 객체와의 위상관계를 통해서 공간 정보뿐만 아니라 비공간 정보의 노출(information flow)이라는 문제가 발생하게 된다. 이에 대한 해결책으로 데이터베이스에 대한 부분집합만을 추출하여 사용자의 권한에 맞는 질의 결과를 제공하는 것이다. 즉 공간 뷰를 정의함으로써 사용자 등급에 맞는 결과 집합(result set)을 제공함으로써 보다 효율적인 연산을 수행할 수 있게 된다. 따라서 본 논문에서는 실세계의 지리 객체들에 대한 다양한 사용자 관점과 다단계 보안 등급을 가진 뷰를 지원하기 위해 관계형 데이터베이스의 뷰 개념을 확장한 공간 데이터베이스의 공간 뷰를 제안하고, 공간 연산 시 발생하는 정보 흐름 제어를 위한 방법을 제시한다.

  • PDF

Fault Analysis Attacks on Control Statement of RSA Exponentiation Algorithm (RSA 멱승 알고리즘의 제어문에 대한 오류 주입 공격)

  • Gil, Kwang-Eun;Baek, Yi-Roo;Kim, Hwan-Koo;Ha, Jae-Cheol
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.19 no.6
    • /
    • pp.63-70
    • /
    • 2009
  • Many research results show that RSA system mounted using conventional binary exponentiation algorithm is vulnerable to some physical attacks. Recently, Schmidt and Hurbst demonstrated experimentally that an attacker can exploit secret key using faulty signatures which are obtained by skipping the squaring operations. Based on similar assumption of Schmidt and Hurbst's fault attack, we proposed new fault analysis attacks which can be made by skipping the multiplication operations or computations in looping control statement. Furthermore, we applied our attack to Montgomery ladder exponentiation algorithm which was proposed to defeat simple power attack. As a result, our fault attack can extract secret key used in Montgomery ladder exponentiation.