Simulation on the performance of an automobile climate control system with Internal heat exchanger and TXV (내부열교환기와 TXV를 적용한 자동차용 공조시스템의 성능에 관한 수치적 연구)

  • Park, Cha-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.1
    • /
    • pp.31-36
    • /
    • 2021
  • Recently, automobile air conditioning systems have applied an alternative refrigerant that can replace the high GWP refrigerant R134a due to the global warming problem. This study simulated the performance of an automobile climate control system with an internal heat exchanger and TXV. Refrigerant R1234yf was applied as the working fluid. Amesim, a commercial software program, was used to model the main components of the compressor, condenser, TXV, evaporator, and internal heat exchanger. As the outside temperature increased from 30℃ to 40℃, the cooling capacity of the system decreased by 3.1%, and the power consumption of the compressor increased by 17.1%. In addition, The performance characteristics of the refrigeration cycle were simulated by increasing the fin pitch of the condenser from 0.8 mm to 1.4 mm. When the fin pitch was larger than 1.0 mm, the condenser capacity decreased, and the system COP was lowered by 5.9%. When the fin pitch of the condenser was 0.8 mm, which was smaller than 1.0 mm, there was no significant change in the system performance. Hence, the optimal performance was observed at a fin pitch of 1.0 mm.

Effect of Reversible Air-circulation Fans on Air Uniformity in a Cultivation Facility for Oyster Mushroom (느타리재배사 정역 제어 대류팬이 공기 균일도에 미치는 영향)

  • Yum, Sung Hyun;Kim, Si Hwan
    • Journal of Bio-Environment Control
    • /
    • v.30 no.4
    • /
    • pp.383-392
    • /
    • 2021
  • It has been known that oyster mushrooms cultivated in facilities with thermal insulation have been strongly affected by inner environments. Forced air-circulation fans exert much direct influence on disturbing air inside the facility so the matter is of particular interest. This study is carried out to investigate the measured levels of air uniformity in a cultivation facility for oyster mushroom in the various cases that reversibly controlled air-circulation fans which drove the flow in the upward and reverse direction by turn and unidirectional fans by which the wind blew upwards only were operated from July 1 to 10. The actual survey for the selection of ongoing operation cases presented that farmers, even though there were some discrepancies, have made use of fans in a way that it paused for 5-30min after running for 5-15min by turn. The level of air uniformity in the case of adopting reversible fans revealed a slight difference of 1.4-1.8℃ (Temp.) and 7.8-8.7% (R.H.) under the condition of not using a cooler during the investigation period. By contrast, unidirectional fans showed a noticeable difference of 3.2-3.7℃ and 14.0-15.4%, which meant that air uniformity driven by reversible fans much more increased compared to that for unidirectional fans. Among the twenty operational applications considered for reversible fans, the circumstance that the wind blew upwards for 10-15min and ceased for 5-10min and blew again in the reverse direction for 10-15min in succession gave minor improvements at the level of air uniformity, but at present there was somewhat difficult to make decision on which cases were optimally best. It seems necessary that the effects of reversible fans on air uniformity as well as qualities of oyster mushrooms have to be appraised in the cultivation period and the flow visualization needs to be done to ascertain the performance of air mixture.

Analysis of Actual State of Facilities for Pleurotus eryngii Cultivation - Based on Western Gyeongnam Area - (큰느타리버섯 재배사의 실태분석 - 서부경남지역을 중심으로 -)

  • Yoon Yong Cheol;Suh Won Myung;Yu Chan
    • Journal of Bio-Environment Control
    • /
    • v.13 no.4
    • /
    • pp.217-225
    • /
    • 2004
  • This study was performed to provide the basic knowledge about the mushroom cultivation facilities. Classified current status of cultivation facilities in Gyeongnam province was investigated by questionnaire. The structure of Pleurotus eryngii cultivation facilities can be classified into the simple and permanent frame type. The simple frame structures were mostly single-span type, on the other hand, the permanent frame structures were more multi-span than simple structures. And the scale of cultivation facilities was very different regardless of structural type. But as a whole, the length, width and ridge height were prevailing approximately 20.0 m, $6.6\~7.0m$ and $4.6\~5.0m$ range, respectively. The floor area was about $132\~160\;m^2$, and floor was built with concrete to protect mushrooms from various harmful infection. The roof slope of the simple and permanent type showed about $41.5^{\circ}\;and\;18.6\~28.6^{\circ}$, respectively. The width and layer number of growing bed for mushroom cultivation were around $1.2\~1.6m$, 4 layers in common, respectively. Most of year round cultivation facilities were equipped with cooler, heater, humidifier, and ventilating fan. Hot water boiler was the most commonly used heating system, the next was electric heater and then steam boiler. The industrial air conditioner has been widely used for cooling. And humidity was controlled mostly by ultra-wave or centrifuging humidifier. But some farmers has been using nozzle system for auxiliary purpose. More then $90\%$ of the mushroom house had the independent environment control system. The inside temperature was usually controlled by sensor, but humidity and $CO_2$ concentration was controlled by timer for each growing stage. The capacity of medium bottle was generally 850 cc and 1100cc, some farms used 800 cc, 950 co and 1,250 cc. Most of mushroom producted has been usually shipped to both circulating company and joint market.

A Research to Decrease Airborne Microoganism the Train (전동차내 부유 미생물 저감방안에 관한 연구)

  • Choi, Sung-Ho;Choi, Soon-Gi;Son, Young-Jin
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2895-2901
    • /
    • 2011
  • SeoulMetro(line number 1 to 4) for the first half of the year. Therefore air quality in the subway is very important. It is passengers, such as sneezing and respiratory vital activities, Suspended due to skin keratin microbial action, and Microbial contaminants such as viruses. Hypersensitivity disorders, an atopic dermatitis, infectious diseases, allergic diseases, and can cause respiratory diseases. Ministry of Environment and National Institute of Environmental Research is managed so the life bacteria. It is emerging as the occupational health problems. Introduction of an appropriate ventilation system for cooling and dehumidification is needed. In line number 2, commuting and normal trains are measured in-room floating microbes. Suspended bacteria and fungi suspended in 2011 for 85 ~ 385$cfu/m^3$, 67 ~ 98$cfu/m^3$ is lower than baseline. Suspended to prevent microbial contamination and air conditioning equipment performance is a substantial improvement. Suspended micro-organisms and the impact on passenger room ventilation is increased. Electric car how to improve air quality substantially investigated.

  • PDF

Study on the energy-saving constant temperature and humidity machine operating characteristics (에너지 절감형 항온항습기 운전 특성에 관한 연구)

  • Cha, Insu;Ha, Minho;Jung, Gyeonghwan
    • Journal of Energy Engineering
    • /
    • v.25 no.3
    • /
    • pp.27-33
    • /
    • 2016
  • The heat recovery system that was applied in this study, is the energy-saving type that can produce the maximum cooling capacity less power in use. In order to have a more precise control function the temperature and humidity of the constant temperature and humidity machine, control algorithm is applied to designed a fuzzy PID controller, and the outside air compensation device (air-cooled) demonstrated excellent ability to dehumidify the moisture, $-20^{\circ}C$ in winter. High efficiency and the low-noise type sirocco fan operate quitely and designed to fit the bottom-up and top-down in accordance with the characteristics of equipment. as a result of experiment data, the conversion efficiency is 95% or more, power recovery time is within 5sec, stop delay time is within 30sec, pump down time is 10sec, pump delay time is 5sec, heating delay time is 5sec, temperature deviation is ${\pm}2^{\circ}C$ (cooling deviation: $2^{\circ}C$, Heating deviation : $2^{\circ}C$), humidity deviation is a ${\pm}5%$ (humidification deviation 3.0%, dehumidification deviation 3.0%). Recently, ubiquitous technology is important. so, the constant temperature and humidity machine designed to be able to remotely control to via the mobile phone, and more scalable to support MMI software and automatic interface. Further, the life of the parts and equipment is extended by the failure.

A Experiment Study on Performance Evaluation of Solar Heat Gain Coefficient in Glazing with Shading Devices (실내 차양장치 결합형 창호의 태양열 취득률 평가에 대한 실험적 연구)

  • Kim, Tae-Jung;Kang, Jae-Sik;Park, Jun-Seok
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.5
    • /
    • pp.89-99
    • /
    • 2014
  • The determination of the solar and thermal performance of fenestration is required for the evaluation of fenestration energy performance, estimating building load. Presently, there exist several methods for determining the thermal transmission(U-value) and solar heat gain coefficient (SHGC) of fenestration system. These method are commonly grouped under calculation or experimental methods. While U-value testing and calculation methods have been long established, SHGC has been evaluated only by the method of calculation under the lack of any established testing method. However, it is difficult to assess the exact SHGC for various types of fenestration with sun-shading or other solar control systems. The purpose of this study was to evaluate the effect of interior venetian blind and roll screen on the SHGC of glazing system. SHGC has been evaluated by the KS L 9107 test method and exiting calculation method for precise comparison of the energy performances of various shading devices. In this research, the test sample consists of three different types of double glazing unit with venetian blind and roll screen. Slat angles of venetian blind were changed to $-45^{\circ}$, $0^{\circ}$, and$-45^{\circ}$. For the roll screen, measurements were taken with the roll screen in the closed position. In result, the venetian blind reduced SHGC by 21.2~28.4% at $45^{\circ}$, when compared to the double glazing unit. The roll screen reduced SHGC by 34.4~41.7% at closed. The differences between the measured and calculated SHGC were found to range between 0.001(0.2%) and 0.047(11.1%) for all test cases. For the cases of venetian blind $-45^{\circ}$, $0^{\circ}$ and $45^{\circ}$, the deviation ratio were 3.6~9.8%, 1.1~2.6%, 4.2~11.1%, respectively. For the case of roll screen, the deviation ratio were 4.1~5.7%.

국가에너지원으로서 가스산업의 위치 및 향후전망

  • 김호경
    • THE INDUSTRY AND TECHNOLOGY OF GAS
    • /
    • v.2 no.1
    • /
    • pp.6-21
    • /
    • 1998
  • 에너지는 인류문명발달의 원동력이며 현대 산업사회에서는 모든 산업활동과 국민경제에 필수적인 요소이므로 세계 거의 모든 나라들은 에너지의 안정확보를 국가정책의 제 1로 삼고 있다. 세계적으로 볼 때 시대의 변천에 따라 에너지의 주역도 바뀌어 산업혁명 후 제2차 세계 대전까지는 석탄이 주역이었고, 2차대전 후 1970년대 석유위기 전까지는 석유가 단연 주역이었다가 석유위기 후 1980년대는 천연가스와 원자력이 상당부문 석유를 대체하고 있으며, 21세기에는 가스이용기술의 개발에 따라 편리성과 경제성에서 가스의 우월성으로 타에너지를 대체하고, 특히 지구온난화방지 노력과 관련하여 전세계적인 $CO_2$ 감축 목표에 따라 청정연료로서 타에너지 보다 사용이 크게 늘어 2010년까지는 1995년의 $50\%$가 증가하여 21세기 연료의 주역이 될 것으로 전망된다. 우리나라는 에너지의 $98\%$를 외국에서 도입하는 상황에서 석유의존도가 $60\%$를 넘고 있으며, 원자력발전소의 확장에 어려움이 많고 세계기후변화협약을 비준한 국가로서 지구온난화방지를 위한 의무를 지게 될 것이므로, 에너지 공급원의 다원화를 통한 안정확보와 청정에너지 이용의 확대 및 에너지 산업에 대한 규제완화 등으로 경제성에 입각한 시장경쟁에서 가스는 우위를 확보함으로써 1차 에너지중 가스의 비중이 매우 높아질 것으로 전망되고있다. 따라서 가스산업은 우리나라 에너지산업중 가장 크게 발전하고 또 다른 에너지가 여러면에서 제약을 받게 될 때 이러한 제약을 극복하는 대체에너지로서 역할이 크게 전망되며, 특히 발전, 열병합, 냉방, 자동차 연료부문에서의 사용이 크게 늘어날 것으로 예상되어 이러한 가스이용의 확대에 대비하여 가스자원의 개발, 국내 공급설비의 확충, 연구개발등에 대한 투자와 규제완화에 의한 시장경쟁에 대한 대비가 필요하다.계산모델 및 원자력병원에서 보유하고 있는 방사선 치료계획장치인 CAP-PLAN의 선량계산모델의 계산 결과와 비교하여, 흡수선량은 ${\pm}10\%$ 이내에서 거리로는 0.4mm 이내에서 대부분 일치하였다. 최대 오차는 각각 $11.3\%$ 및 0.8mm로 나타났다. 이상의 결과들로부터 새로 개발한 금으로 된 기구와 Ir-192 seed를 이용한 근접 방사선 치료법으로 안구의 악성종양에 대한 치료를 보다 효과적으로 시행할 수 있을 것으로 기대된다. 구성원을 간소 목적을 위하여 사용할 수 있어야 하겠다 마지막으로 이들 내의 위험 집단을 우선적으로 파악. 접근하여야 할 것이다. 위험 집단으로는 경제적 문제로 적절한 의료 이용을 할 수 없는 저소득층, 문화적으로 열등한 위치에 있는 여성층과 초기 이민 적응에 가장 문제를 일으킬 소지가 있는 노년층을 들 수 있겠다. 이 연구는 몇 가지 제한점을 가진다. 첫째. 연구 대상자 선정이 어려워서 자원자를 대상으로 연구가 행해졌다. 둘째. 적은 수의 연구 대상자를 대상으로 연구가 행해졌다. 셋째. 연구기간이 짧았던 까닭에 좀더 상세한 사례 연구가 이루어질 수 없었다 좀 더 신뢰할 수 있는 표본 추출 방법을 통하여 선정된, 많은 연구 대상자를 가지고, 심도 있는 연구가 추후 반복적으로 이루어져야 할 것이다.더욱 더 발전을 거듭하고 있으며, 외식은 여행과 여가 활동의 필수적인 요소로써 그 역할을 일조하고 있다. 이와 같은 여가시간의 증가는 독신자들에게는 좀더 많은 여유시간을 가족을 이루고 있는 가족구성원들에게는 가족과의 유대를 강화하는 휴식과 오락의 소비 트렌드를 창출시켰다. 이와 더불어 외식은 식사를 해결하기 위한 단순한 수단에서 벗어나 동기와 동반자에 따라 달라지는 행동 패턴을 나타내고 있으며, 연령과 목적에 따라 세분화되는 분명한 선호도를 나타낸다. 지난 10여 년간 외국으로부터 수입된 다양한

  • PDF

Actual State of Structures and Environmental Control Facilities for Tomato Greenhouses in Chungnam Region (충남지역 토마토 재배온실의 구조와 환경조절설비 실태분석)

  • Nam, Sang-Woon;Kim, Young-Shik
    • Korean Journal of Agricultural Science
    • /
    • v.36 no.1
    • /
    • pp.73-85
    • /
    • 2009
  • An investigation was conducted to get the basic data for establishing structural safety and environmental management of tomato greenhouses in Chungnam region. The contents of the investigation consisted of actual state of greenhouse structures and environmental control facilities. Most of greenhouses were arch type single-span plastic houses and they had too low height for growing tomatoes. Frameworks of multi-span greenhouses were suitable, but those of single-span were mostly insufficient. Every greenhouse had thermal curtain movable or covering fixed inside the greenhouse for energy saving, and heating facilities were mostly warm air heater. Irrigation facilities were mostly drip tube and controlled by manual operation or timer. Almost all of the greenhouses didn't install high level of environmental control facilities such as ventilator, air circulation fan, $CO_2$ fertilizer, insect screen, supplemental light, and cooling device.

  • PDF