Browse > Article
http://dx.doi.org/10.7836/kses.2014.34.5.089

A Experiment Study on Performance Evaluation of Solar Heat Gain Coefficient in Glazing with Shading Devices  

Kim, Tae-Jung (Korea Institute of Civil and Building Technology, Department of Sustainable Architectural Engineering, graduate school of Hanyang University)
Kang, Jae-Sik (Korea Institute of Civil and Building Technology)
Park, Jun-Seok (Department of Architectural Engineering, Hanyang University)
Publication Information
Journal of the Korean Solar Energy Society / v.34, no.5, 2014 , pp. 89-99 More about this Journal
Abstract
The determination of the solar and thermal performance of fenestration is required for the evaluation of fenestration energy performance, estimating building load. Presently, there exist several methods for determining the thermal transmission(U-value) and solar heat gain coefficient (SHGC) of fenestration system. These method are commonly grouped under calculation or experimental methods. While U-value testing and calculation methods have been long established, SHGC has been evaluated only by the method of calculation under the lack of any established testing method. However, it is difficult to assess the exact SHGC for various types of fenestration with sun-shading or other solar control systems. The purpose of this study was to evaluate the effect of interior venetian blind and roll screen on the SHGC of glazing system. SHGC has been evaluated by the KS L 9107 test method and exiting calculation method for precise comparison of the energy performances of various shading devices. In this research, the test sample consists of three different types of double glazing unit with venetian blind and roll screen. Slat angles of venetian blind were changed to $-45^{\circ}$, $0^{\circ}$, and$-45^{\circ}$. For the roll screen, measurements were taken with the roll screen in the closed position. In result, the venetian blind reduced SHGC by 21.2~28.4% at $45^{\circ}$, when compared to the double glazing unit. The roll screen reduced SHGC by 34.4~41.7% at closed. The differences between the measured and calculated SHGC were found to range between 0.001(0.2%) and 0.047(11.1%) for all test cases. For the cases of venetian blind $-45^{\circ}$, $0^{\circ}$ and $45^{\circ}$, the deviation ratio were 3.6~9.8%, 1.1~2.6%, 4.2~11.1%, respectively. For the case of roll screen, the deviation ratio were 4.1~5.7%.
Keywords
Solar Heat Gain Coefficient, SHGC; U-value; Venetian blind; Roll screen; Cooling energy;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 Ministry of Trade, Industry and Energy, Energy consumption survey Report. 2011
2 M. R. Collins and S.J. Harrison, Calorimetric Measurement of the Inward-Flowing Fraction of Absorbed Solar Radiation in Venetian Blind, ASHRAE Transactions: Conference proceeding by ASHRAE, pp. 1022-1030, 1999
3 Ministry of Trade, Industry and Energy, Prospect of Electricpower, Consumption and supply in summer, 2013
4 Yool Park and Jong-Il Park, A study of Energy use Impact by SHGCs of Windowsin Detached House, Korea Journal of Air Conditioning and Refrigeration Engineering, Vol. 22, No. 4, pp. 189-196, 2010
5 T. R. Nielsen, K. Duerand S. Svendsen, Energy performance of glazing and windows, Solar energy, Vol. 69, No. 6, pp. 137-143, 2000
6 Fangzhi Chen, Stephen K. Wittkopf, Pho Khai Ng and Hui Du, Solar heat gain coefficient measurement of semi-transparent photovoltaic modules with indoor calorimetric hot box and solar simulator, Energy and Buildings, Vol. 53, pp. 74-84, 2012
7 Deivis L. Marinoski, Saulo Guths and Roberto Lamberts, Development of a calorimeter for determination of the solar factor of architectural glass, Building and Environment, Vol. 47, pp. 232-242, 2012   DOI   ScienceOn
8 KS L 9107, Testing method for the determination of solar heat gain coefficient of fenestration product using solar simulator, 2014
9 Klems J. H. and Warner J. L., A New method for Predicting the Solar Heat Gain of Complex Fenestration System, ASHRAE Transaction, Vol. 100, pp. 303-312, 1993
10 Lim J. H. and Song S. Y., Evaluation on the Solar Heat Gain Coefficient installed in internal shading device by experiments according to the NFRC 201, Journal of the Korean Solar Energy Society, Vol. 30, No. 3, pp. 47-53, 2010   과학기술학회마을
11 Lim J.H. , The Effect of Interior Exterior Venetian Blinds Integrated with Glazing System on the Solar Heat Gain Coefficient, J. Korean Soc. Living Environ, Vol. 17, No. 5, pp. 529-538, 2010
12 KS C IEC60904-9, Photovoltaic devices-Part 9 : Solar simulator performance requirements, 2010
13 KS F 2278, Test method of thermal resistance for windows and doors, 2008
14 ISO 15099, Thermal performance of windows, doors and shading devices-Detailed calculations, 2003