• Title/Summary/Keyword: 내화용 재료

Search Result 71, Processing Time 0.019 seconds

Development and Performance of Cementitious Materials for Fire Resistance of Tunnel (터널 내화용 시멘트계 재료의 개발 및 성능 평가)

  • Won, Jong Pil;Choi, Seok Won;Park, Chan Gi;Park, Hae Kyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.4C
    • /
    • pp.265-273
    • /
    • 2006
  • This study aims at evaluation of the fire resistance performance of cementitious materials for fire protection of tunnel. For this purpose, the research procedure was divided into three parts. First, base mix proportion with different material type were determined by fire test. Second, the fire test of cementitious materials for fire resistance were performed on base mix proportions to evaluated their performance. Third, the performance of cementitious materials for fire resistance compare to the target value and existing commercial products. If the performance of developed cemetitious materials for fire resistance were satisfied the target value, this studies were stopped. But, this research return to first process if the performance of cementitious materials for fire resistance are not satisfied the target value. As a result of this study, the spalling did not happen for develop and existing commercial product. Also, developed cementitious materials for fire resistance are shown with excellent compressive strength, flexural strength, and bond strength, because it used a height density aggregate. And developed cementitious materials has sufficient resistance for fire.

Temperature Distribution of Wet-Mixed High Strength Sprayed Polymer Mortar for Fire Resistance of Tunnel (터널 내화용 고강도 습식 스프레이 폴리머 모르타르의 화재 발생시 내부온도분포)

  • Won, Jong Pil;Choi, Seok Won;Park, Chan Gi;Park, Hae Kyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.4C
    • /
    • pp.283-290
    • /
    • 2006
  • Concrete has advantages in fire situations as it is non-combustible and has low thermal conductivity. However, concrete that is not designed against fire can experience significant explosive spalling from the build-up of pore pressures and internal tensile stresses when heated. In this study, the performance of wet-mixed high strength sprayed polymer mortar for fire resistance of tunnel system was evaluated by experimentally and numerically. The fire test was performed in fire resistance(electric) furnace according to RABT(Richtlinien fur die Ausstatung und den Betrieb von $Stra{\beta}entunneln$) time heating temperature curve, so as to evaluate the temperature distribution with cover thickness of wet-mixed high strength sprayed polymer mortar for fire resistance of tunnel system. Based on experimental results and numerical analysis, the proper cover thickness of wet-mixed high strength sprayed polymer mortar determined the more than 4cm.

Properties of Intumescence Alkali Silicates for Building Fire-Resistant (건축용 내화 재료로서의 포비성 알칼리 규산염의 특성에 관한 연구)

  • Kang, Hyun Ju;Kang, Seung Min;Song, Myong Shin;Kim, Young Sik;Park, Jong Hun
    • Applied Chemistry for Engineering
    • /
    • v.20 no.4
    • /
    • pp.416-422
    • /
    • 2009
  • The buildings constructed with steel structure are coated with certified fire resistive material to resist from fire. All the building materials lose their initial performances as time passes by, so they need some maintenance. The Sprayed Fire Resistive Material (SFRM) also loses its performance and this performance loss of the SFRM is very important because fire resistance of buildings depends on SFRM. So this study was aimed to synthesis of alkali-silicates for SFRM and to evaluate the effect of alkali-silicates, K-silicates, Na-silicates and Li-silicates, by exchange of mole ratios as basic factors, tested solubility, intumescence ratios, thermal analysis, powder X-ray diffraction, fire-resistant and heat-resistant.

Ti 및 S 함유 용강중 Mg-gas 취입기술 개발을 위한 기초 연구

  • Yun, Jeong-Bae;Jeong, U-Gwang;Jo, Mun-Gyu
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.11a
    • /
    • pp.47.2-47.2
    • /
    • 2009
  • Ti 및 S를 함유하는 강종의 연속주조시 노즐막힘 현상이 자주 발생한다. 이러한 강종의 연주기술과 생산성을 향상 시키기 위해서는 노즐막힘 발생을 방지하기 위한 새로운 기술의 개발이 필요하다. 노즐막힘은 노즐내벽에 개재물의 부착으로 인해 발생되는 것으로 용강의 물성 혹은 내화물 재질의 개선을 통하여 방지하거나 저감할 수 있다. 본 연구에서는 노즐내 용강에 Mg 증기를 취입하였을 때의 내화물과 용강 계면에서의 반응 및 현상에 대하여 조사하고 내화물/용강계면에서의 생성물 분석과 용강중 S와 Ti의 농도에 따른 노즐 내화물과의 접촉각을 측정하였다. Mg증기는 MgO-Al 혼합물을 가열함으로 Al에 의한 Mg 의 환원반응에 의해 발생되며, 온도와 MgO와 Al 분말의 입도에 따른 Mg증기 발생거동에 대하여 고찰한다.

  • PDF

A Study for Structural Stabilities of Beams Built with TMC Fire Resistant Steels by Analytical Method at High Temperatures (해석적 방법에 의한 TMC 건축용 내화강재 적용 보부재의 고온 내력평가 연구)

  • Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.60-66
    • /
    • 2017
  • Steel framed building can be destroyed due to deteriation of structural stabilities in a fire. This leads a TMC Fire Resistant Steels and this study analyzed the structural stabilities such as a deflection and a reduction of maximum load capacity for the structural beams built with a TMC Fire Resistant Steel. In this study the structural stabilities were evaluated using a mechanical properties in high temperatures not only a heat transfer theory but a heat stress anlaysis with a statistically determinated beam and a statistially indeternated one. The results showed that a TMC Fire Resistant Steels demonstrated a little lower those of Fire Resistant Steels.

Evaluation of Wet-Mixed High Strength Sprayed Polymer Mortar for Fire Resistance (내화용 고강도 습식 스프레이 폴리머 모르타르의 화재 저항성 평가)

  • Won, Jong-Pil;Choi, Seok-Won;Park, Chan-Gi;Park, Hae-Kyun
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.4 s.94
    • /
    • pp.559-568
    • /
    • 2006
  • The purpose of this study is to evaluate the mechanical performance and fire resistance of wet-mixed high strength sprayed polymer-modified mortar in order to protect tunnel lining system which are in the event of fire disaster. Since the current commercial fire-resistant materials reproduce the low strength issue of mortar, this study aims to provide an enhanced fire-resistant mortar with a proper strength. Normally, a large temperature gradient phenomenon arise in the vicinity of free surfaces which are fully exposed in the event of persistent flame. Thereby, the determination of optimal cover depth of wet-mixed high strength sprayed polymer-mortar(WHSPM) is important for fire-resistance of tunnel lining system. With comparison of current commercial fire-resistance materials and WHSPM, the experimental result of WHSPM shows the better fire-resistant performance than the others. In addition, the cover limitation should be controlled by minimum 4cm depth in order to avoid fire-induced damage.

Heat Transfer Finite Element Analysis of Iron-manufacturing Furnace Structures (제철용 고로 구조물의 열전도 유한요소해석)

  • Choi Woo-Cheol;Paik Jeom-Kee;Lee Je-Myung;Kim Won-Beom;Lee Man-Seung;Han Dae-Suk
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2005.04a
    • /
    • pp.291-294
    • /
    • 2005
  • 본 해석은 제철용 고로 구조물에 대해여 고로 내의 온도 분포를 이용한 열전도 유한요소 해석을 수행하고자한다. 해석모델인 고로는 내화벽돌, 냉각판, 내화재(castable), 철피의 복잡한 구조로 이루어져있다. 각각의 재료뿐만 아니라 고로에 사용되어지는 모든 내화벽들의 재료 물성치 값을 사용하여 보다 실직적인 해석을 수행하고자 하며 고로의 냉각 시스템인 냉각판과 냉각 pipe의 효과 규명하고자 한다. 어떠한 부분 모델이 아니라 고로 전체를 대상으로 열전도 해석을 수행한다.

  • PDF

Mechanical Properties of Composite Materials Composed of Structural Steel and Structural Glued Laminated Timber (구조용 강철과 구조용 집성재 복합재료 보의 역학적 성질)

  • Jang, Sangsik;Kim, Yunhui;Jang, Youngik
    • Journal of the Korean Wood Science and Technology
    • /
    • v.37 no.4
    • /
    • pp.300-309
    • /
    • 2009
  • The effective utilization of wood structure is encouraged to preserve natural resources and the global environment. Long-span and large-scale structures are preferred to promote demand for wood. This study attempts to develop new Fire-resistance Composite Material composed of Structural steel and Structural glued laminated timber for long-span and large-scale structures. Prior to take a fire-resistance test, compare properties of bending strength with Composite material composed of Structural steel and Structural glued laminated timber, structural steel and structural provides the stability of the structure, but the structural glued laminated timber has high value elasticity of bending. Using the Composite material will improve structural stability and Eco-friend construction environment.

Experimental Study on the Thermal Properties of Materials for Fire Resistive Ceiling Structure at High Temperature (내화천장구조 재료의 고온 열특성 실험 연구)

  • Yeo, In-Hwan;Cho, Bum-Yean;Min, Byung-Yeol;Kim, Heung-Youl
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.334-339
    • /
    • 2011
  • 이 연구에서는 내화천장구조 재료의 고온 열특성을 파악하여, 건축물 화재시 천장구조에 대한 보다 정확한 화재성상예측을 위한 실험적 자료로 제시하고자 한다. 건축물의 화재성상 예측은 내화설계 시 반드시 필요하며, 화재성상예측을 위해서는 화재하중, 작용외력, 안전계수 및 설계용 정수의 합리적인 설정이 중요하다. 화재하중 및 작용외력 등은 건축물의 부재가 지니는 하중조건에 대한 화재시의 부재 안정성 예측에 관계되는 부분이며, 설계 시 필요한 데이터 중 내화천장구조 재료의 고온 열특성 값은 화재발생 구획의 화재온도가 주요 구조부재에 전달되는 정도를 예측할 수 있는 인자로 볼 수 있다. 따라서 내화천장구조 재료의 고온 열특성 값 설정은 화재발생 공간의 온도범위($20{\sim}1000^{\circ}C$)에 걸쳐 평가 및 분석되어야만 정확하고 신뢰성 있는 화재발생 예상 공간의 부재 온도 및 안전성 분석이 가능하다. 이에 국내 건축구조물에 사용되고 있는 대표적인 내화피복 재료인 방화석고보드, 텍스, 암면에 대해서 $20^{\circ}C{\sim}900^{\circ}C$까지의 열전도율을 측정하였다. 실험결과 방화석고보드와 텍스의 경우 약 0.15 W/m K까지 일정하게 증가하였다. 암면의 경우 약 $700^{\circ}C$까지는 방화석고보드나 텍스에 비해 열전도율이 낮게 나타났지만, $800^{\circ}C$ 지점부터 용융 및 탄화가 진행되면서 열전도율이 급격히 상승하는 것으로 나타났다.

  • PDF

Flame Resistance Performance of Architectural Membrane According to Woven Fabrics and Coating Materials (직포 및 코팅재 타입에 따른 건축용 막재의 난연성능)

  • Kim, Ji Hyeon;Song, Hun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.6
    • /
    • pp.545-551
    • /
    • 2016
  • Membrane structures which can be used large spatial structure are being expanded because of various advantages. However, despite the diverse membrane structure buildings and materials, the standard for membrane material performance that considering fire safety is still inadequate. Therefore, this study applied basalt or glass woven fabric with flame resistance on architectural membrane, and report the fire safety for architectural membrane using the strength properties, flammability and incombustibility. From the test result, the architectural membrane using basalt or glass woven fabric showed a low heat release rate and total heat release. Therefore, it was confirmed that the fire safety is relatively high.