Prototype Development and Experimentation to Improve the Seismic Performance of Curtain walls (커튼월의 내진성능 향상을 위한 시제품 개발 및 실험)

  • Min, Byoung jun;Won, Jeong hun;Jeon Jin woo;Kang, Hyun Wook
    • Korean Journal of Construction Engineering and Management
    • /
    • v.24 no.4
    • /
    • pp.14-24
    • /
    • 2023
  • The purpose of this study is to develop a prototype curtain wall with improved seismic performance and to verify the seismic performance by conducting an inter-floor displacement test. To this end, a prototype of the curtain wall was manufactured and a displacement similar to the earthquake load was induced, and then the damaged state of the curtain wall was checked. As a result of the first test, the frame and glass of the curtain wall were not damaged, but the Weather Sealant was partially damaged. As a result of the second test, there was no problem of glass breakage in seismic class (special), seismic class (I), seismic class (II), and AAMA 501.6. Through this experiment, the seismic performance of the curtain wall prototype was verified.

대형 내진시험 구조물에 대한 강제진동시험 결과의 예측 및 예측후상관해석

  • 박형기;조양희;윤철호
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05b
    • /
    • pp.1005-1010
    • /
    • 1995
  • 지반-구조물 상호작용해석에 부분구조법의 적용성 확인과 해석법의 개선을 모색하기 위하여, 대만 Hualien지방에 건설한 대형 내진시험 구조물의 뒷채움후 강제진동시험 결과를 부분구조법으로 예측하고 예측후상관해석을 수행하였다. 모델로서는 재료시험과 지반조사 결과로 작성된 통일모델과 예측후상관해석모델을 사용하였으며, 해석은 진동 수영역과 시간영역에서 각각 이루어졌다 연구 결과로 깊이 묻힌 구조물의 경우는 구조물이 묻힌 측면지반의 영향인 수평병진과 수평축회전의 연계 임피던스함수에 대한 적절한 평가와 해석시에 반드시 고려되어야함을 알 수 있었다.

  • PDF

Seismic Qualification of Class 1E Battery by Combined Analysis and Testing (수치해석과 실험을 통한 안전등급 축전지의 내진검증)

  • 김영중;박성환;정태영;정정훈
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1992.10a
    • /
    • pp.87-91
    • /
    • 1992
  • 축전지를 탑재한 프레임형 랙에 대한 공진탐색시험결과를 이용하여 유한요 소에 의한 수치해석모형을 결정하였다. 내진검증시험은 에이징시험을 거친 3 개의 축전지를 포함하여 28개의 축전지를 탑재한 시험랙을 대상으로 수행되 었다. 공진탐색시험으로부터 구한 모달특성치를 이용하여 지진응답을 해석하 였으며 실험치와 부합함을 확인하였다. 시험랙의 지진응답이 실제 설치될 60 개의 축전지를 갖는 전체랙의 응답보다 크므로, 시험랙에 의한 내진검증이 보다 열악한 조건에서 수행되었다고 볼 수 있다. 시험랙에 대한 내진검증시 구조부재의 구조적 안정성과 축전지의 성능유지를 확인한 바 있으므로 전체 랙의 경우에도 내진검증이 이루어졌다고 판단된다.

  • PDF

Pseudo Dynamic Test for the Seismic Performance Evaluation of Circular RC Bridge Piers Retrofitted with Fibers (섬유보강 원형 RC교각의 내진성능 평가를 위한 유사동적실험)

  • 정영수;박종협;박희상
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.2
    • /
    • pp.49-57
    • /
    • 2001
  • 본 연구의 목적은 유사동적실험에 의한 섬유보강 원형 RC교각의 내진성능평가를 위한 연구로서 수원시에 위치한 내진교량인 하길교를 대상모델로 하였으며, 도로교 표준시방서의 내진설계규정이 적용되지 않은 비내진교각시험체 2본 및 내진성능향상을 위한 섬유보강시험 4본, 즉 총 6본에 대하여 유사동적실험을 수행하였다. 보강공법으로는 유리 탄소섬유 보강공법을 사용하였으며, 실험변수로는 입력지진동, 섬유고방유무로 하였다. 그리고 내진성능평가 방법은 입력 및 소산에너지, 변위 연성도가 분석되었다. 본 실험의 결과 유리 섬유로 보강된 비내진시험체의 변위연성도 KHC인공지진파에 대하여 7.7~9.0정도의 값으로 충분한 내진성능을 확보하고 있는 것으로 평가되었다.

  • PDF

Design and Performance Test of Ventilation Sliencer for PWR Nuclear Power Plant (원자력 발전소용 덕트형 소음기 개발)

  • 김준호;김영찬;유승국;김두훈;이종림;전규식
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.488-492
    • /
    • 1997
  • 원자력 발전소의 공조 시스템에 설치되는 덕트형 소음기를 설계.제작하여 감음성능 시험, 내진해석, 내진시험, 난연시험 및 기밀시험 등을 수행하여 각각의 요구조건에 적합한 소음기를 설계.제작한 결과 원자력 발전소에 기 설치된 소음기와 동등한 성능을 갖는 것으로 나타났다. 소음기를 설계, 제작, 시험하는 과정에서의 노-하우를 바탕으로 어떠한 요구조건에도 만족하는 제품을 국내에서 설계.생산할 수 있는 기술 확보에 있다.

  • PDF

Shaking Table Tests for Evaluation of Seismic Performance of Quay Walls (안벽 구조물의 내진성 평가를 위한 진동대 시험)

  • 김성렬;박영호;권오순;김명모
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.5
    • /
    • pp.75-81
    • /
    • 2000
  • 본 연구에서는 진동대 시험을 실시하여 지진동에 대한 일반 안벽 구조물과 내진 보강된 안벽 구조물의 동적거동을 분석하고 내진보강기법의 성능을 평가하였다. 진동대 시험은 기초지반이 조밀한 경우와 느슨한 경우, 자갈 뒤채움재를 설치한 경우 그리고 내진대책공법으로 경량재 치환공법과 모래다짐말뚝 공법을 적용한 경우 등 총 5가지 시험단면에 대하여 실시하였다. 과잉간극수압, 가속도 반응 그리고 지반의 변형양상을 분석한 결과, 기초지반과 뒤채움 지반의 연약화가 안벽 구조물의 동적거동에 큰 영향을 미치며, 경량재 치환공법과 모래다짐말뚝공법이 안벽 구조물의 내진성능을 향상시키는에 효과적인 것으로 나타났다.

  • PDF

6자유도 진동대 - 특성 및 활용방안

  • 이호섭
    • Journal of KSNVE
    • /
    • v.1 no.1
    • /
    • pp.7-19
    • /
    • 1991
  • 해사기술연구소가 보유하고 있는 6자유도 대형진동대의 시스템 구성과 시험파형 합성기법 및 시험방법에 대하여 간략히 살펴보았다. 통상적인 가진기가 1방향의 운동만을 구현할 수 있음에 비해, 6자유도 진동대는 3축병진, 3축 회전의 임의의 복잡운동을 구현할 수 있는 국내 유일의 설비이며 용량 또한 30톤의 시험체까지를 대상으로 한 대형 진동대로서 각종 분야에 필요한 진동시험 업무를 지원할 수 있다. 구조물의 방진 및 내진설계를 위해서는 가능한한 실물 또는 모형의 실증실험이 필수적이며, 이는 내진 해석기법의 개발 및 검증의 기초가 된다. 특히 이 시스템은 내진 검증시험에 필요한 모든 기능을 갖추고 있으므로, 앞으로 건설될 국내원자력 발전소에 이용되는 각종기기의 내진검증시험을 통하여 이들 기기의 국산화에 크게 이바지할 것으로 보인다.

  • PDF

Experimental Study of a Seismic Reinforcing System without Power Interruption and Movement for Electric Panel on the Access Floor (무정전-무이설 방식의 전기판넬 내진보강시스템 시험연구)

  • Jang, Jung-Bum;Lee, Jong-Rim;Hwang, Kyeong-Min;Ham, Kyung-Won
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.3
    • /
    • pp.1-10
    • /
    • 2009
  • The seismic reinforcing system is developed to prevent damage to electric panels which are installed on the access floor and are essential to the operation of various basic facilities such as electric power and communication etc., from earthquakes. The seismic capacity of seismic reinforcing system is verified through the shaking table test. The seismic reinforcing system is intended for the electric panel on the access floor, and installation is possible without movement and power interruption of the electric panel. The enveloped response spectrum is adopted considering the location of the electric panel in the building as input motion for the shaking table test. The shaking table tests are carried out with two electric panels that can be considered representative of general electric panels, and two types of access floors such as wood panel and steel panel, which are commonly used in the industrial field. As a result of tests, it is confirmed that the seismic reinforcing system secures the seismic safety of electric panels by preventing the overturning of electric panels during and after the shaking table tests. In the event that the seismic reinforcing system is applied to the electric panel on the access floor, damage to the electric panel from an earthquake can be effectively prevented, which can greatly contribute to the stable operation of domestic basic facilities.

Quasi-Static Tests for Seismic Performance of Circular RC Bridge Piers (단일주 원형 철근콘크리트 교각의 내진거동에 관한 준정적 실험)

  • 정영수;이강균;한기훈;박종협
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.3 no.2
    • /
    • pp.55-66
    • /
    • 1999
  • Eight RC bridge plers have been made on a 1/3.4 scale model and have been tested in a quasi-static cyclic load so as to investigate their seismic performance. The ultimate objective of this experimental study is to investigate the hysteretic behavior of reinforced concrete plers, which have been widely used for urban transportation facilities in Korea. Improtant test parameters are hoop ratio, axial load, load pattern, and etc. And noninear behaviors of test columns have been evaluated through their yield and ultimate strength, energy dissipation, ductility and load-deflection characteristics under quasi-static cyclic loads. From the quasi-static tests on 8 bridge piers, it is concluded that energy dissipation, ultimate strength and curvature for a given displacement factor ${\mu}={\Delta}/{\Delta}_y$ are higher for the seismically designed columns than for the nonseismically designed columns.

  • PDF

Modal Identification and Seismic Performance Evaluation of 154kV Transformer Porcelain Bushing by Vibration Test (진동시험에 의한 154kV 변압기 부싱의 동특성 분석 및 내진성능 평가)

  • Joe, Yang-Hee;Cho, Sung-Gook
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.5 s.51
    • /
    • pp.107-115
    • /
    • 2006
  • The power supply system is one of the most important infrafacilities which should maintain their inherent function during and after earthquakes. This study was performed to analyze dynamic characteristics and seismic performance of Korean typical 154kV transformer porcelain bushing. For the purpose of this study, actual 154kV porcelain bushings were selected and tested on the shaking table. The vibration tests consist of modal identification tests, seismic performance tests, and fragility tests. The sine sweep waves, artificial earthquake waves, and continuous resonant sine waves were used as shaking table motions. This paper describes the test specimens, shaking facilities, and test methods. Natural frequencies and damping ratios of the bushing have been evaluated from the experimental data. The failure mode and the performance level of the Korean transformer bushing have been first identified in this study.