• Title/Summary/Keyword: 난시안

Search Result 110, Processing Time 0.02 seconds

Changes in KVA Resulting from Correction Condition of Refractive Error (굴절이상 교정상태에 따른 동적시력 변화)

  • Shim, Hyun-Suk;Kim, Sang-Hyun;Kang, Hye-Sook
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.165-171
    • /
    • 2013
  • Purpose: This study are to analyze and to compare between pupillary size, reaction time, refractive error, corrected vision, dominant eye, static visual angle (SVA) and kinetic visual acuity (KVA) of male and female college students, to measure KVA of them in full correction and to identify changes of KVA by +0.50 D and -0.50 D spherical power addition respectively in full correction condition. Methods: KVA, SVA, pupillary size, reaction time, refractive error, corrected vision and dominant eye of 40 male and 40 female optical science students were measured by utilizing KOWA AS-4A, reaction time measurement program, subjective refractometer, and objective refractometer, and KVAs were measured when +0.50 D/-0.50 D were added in both eyes respectively. Results: Binocular KVA of whole subjects was $0.45{\pm}0.22$, and in monocular KVAs were $0.36{\pm}0.19$ for right eye and $0.34{\pm}0.19$ for left eye, and binocular KVA was significantly higher than monocular KVA. It appeared that the better SVA was, the better KVA was in significant way, and in terms of refractive error the less myopia amount was, the better KVA was, but it was not significant statistically. The lower astigmatism was, the slightly and significantly higher KVA was when dividing between equal or less than -1.00 D astigmatism group and over -1.00 D astigmatism group. In resulting from correction condition of refractive error KVAs were $0.45{\pm}0.22$ for full correction, $0.26{\pm}0.15$ for +0.50 D addition, $0.48{\pm}0.22$ for -0.50 D addition which indicates that KVA in over myopia correction was significantly the highest and followed by full correction and under correction. Similar findings were revealed in both male and female, and KVA of male was better than female in comparing between male and female. There was no significantly different KVA between dominant eye and non-dominant eye. Conclusions: Accordingly, it is concluded that KVA is related with far distance SVA, astigmatism amount, and refractive error amount except a dominant eye. Through this research, it was found that prescription for enhancing KVA is to make full correction or to overcorrect slightly myopia.

A Study on the Corneal Refractive Power of Myopic Eyes in Korean (한국인 근시안의 각막 굴절력에 관한 연구)

  • Sung, Duk Yong;Youk, Do Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.2
    • /
    • pp.17-22
    • /
    • 1999
  • In this study, corneal power and eye refraction error were studied on myopic of unaccommodated koreans. The mean of refraction error power is -2.39D(male : -2.75D, female : -2.02D). The mean of corneal refraction error power is +43.90D(male : +44.07D, female : +43.71D). It is +0.90D higher than that of the model eye by Gullstrand(about + 43.00D).

  • PDF

Study of Ocular Components in Determining the Refractive State of the Eye (굴절이상을 결정하는 안광학 요소에 관한 연구)

  • Seo, Y.W.;Choe, Y.J.
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.1
    • /
    • pp.7-14
    • /
    • 1999
  • The purpose of this study is to evaluate the relationship between ocular components and refractive error for human eye. Ocular components were measured by keratometry, phakometry, and ultrasonography. Refractive error was measured by subjective refraction on 38 subjects aged from 17 to 30. The results were as follows; 1) Refractive error and axial length, vitreous chamber depth, axial length/corneal radius were highly correlated that the correlation coefficients were 0.95, 0.96, 0.95, respectively. 2) Refractive error and corneal radius, corneal power, lens thickness were correlated with the correlation coefficients for 0.60, 0.66, 0.67 respectively. 3) There were no significant correlation between refractive error and corneal thickness.

  • PDF

Performance of State-of-the Art ATSC DTV Receivers for Multipath Fading Environments (최신 ATSC DTV 수신기의 다중 경로 페이팅 환경에서의 수신 성능 평가)

  • Lee, Dong-Hoon;Park, Sung-Woo;Kim, Jung-Jin;Jeong, Jin-Hee;Chang, Yong-Deok;Jeong, Hae-Joo
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.191-195
    • /
    • 2006
  • 국내와 북미 지역에서 ATSC DTV 방송 서비스가 시작된 이래 수신 성능을 개선하기 위한 계속적인 노력이 경주되어 왔다 [1]-[6]. 본 논문에서는 2005 년 8 월 캐나다 CRC (Communications Research Center) 센터의 테스트 결과를 토대로 최신 ATSC 수신기의 성능을 고찰해 보고자 한다 [4]. CRC 테스트는 수신 감도, 다중 경로 환경에서의 수신 성능, 간섭 신호에 대한 강건성 등 다양한 항목에 걸려 실시되었으며, A/74 권고안에 기술된 난시청 지역의 50 개 신호 샘플에 대한 성능 평가를 포함하고 있다. 테스트에 사용된 ATSC 수신기는 당사에서 개발한 최신 칩 (GEMINI)을 탑재한 것으로 파일럿 (pilot) 신호가 손상된 경우에도 안정적인 동기 획득이 가능하며 현존 수신기 중 가장 넓고 강력한 반사파 (ghost) 제거 성능을 보유하고 있다. CRC 테스트 결과와 국내외 필드테스트 결과는 최신 ATSC 수신기가 A/74 권고안뿐만 아니라 각종 성능 지표에서 이전 수신기에 비해 대폭 개선되었음을 확인시켜 준다.

  • PDF

The Effects of Alcohol on Eye Refraction (알코올이 눈의 굴절에 미치는 영향)

  • Lee, Hak-Jun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.2
    • /
    • pp.139-144
    • /
    • 2001
  • This paper was investigated the change of naked visual acuity and the full corrective refractive powers of alcoholicity for 0, 0.05 and 0.1. We research the prescriptions for 9 males and females 9 aged 20 above years. The naked visual acuity was decreased with increasing alcoholicity. Most of tested patients, the spherical refractive powers was also decreased with increasing alcoholicity. The change of the cylinder refractive power was uniformity. For the astigmatism axis. there were many changes.

  • PDF

Developing a Smart-phone App for Sight Protection (시력보호를 위한 스마트폰 앱의 개발)

  • Kim, Seong-Hoon;Park, Min-Gyun
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2011.01a
    • /
    • pp.321-322
    • /
    • 2011
  • 이 논문에서는 최근 각광 받는 의료 융합 IT를 이용한 모바일 콘텐츠로써 안과 병원을 찾지 않고도 스마트폰을 이용하여 건강관리 서비스를 제공하는 스마트폰 앱의 개발을 다룬다. 개발하려는 서비스를 통하여, 자신의 눈 상태를 체크하고 예방할 수 있으며, 주기적인 시력검사 및 색맹/색약, 난시/근시 등의 질환을 검사하고 동체시력운동, 원근법 눈운동, 눈체조 등 눈이 좋아지는 운동과 눈이 좋아지는 그림을 통하여 눈의 피로를 해소하고자 한다. 또한 검사 결과에 따른 개인별 검사 관리표, 시력 예방 관리 그래프 제공하여 자가진단 및 시력 관리를 할 수 있도록 한다. 이러한 서비스는 시간과 장소에 구애 받지 않고 사용자에게 제공 하도록 스마트폰 앱으로 개발한다.

  • PDF

The Effects of Corneal Type and Corneal Astigmatism on Tear Volume between Rigid Gas Permeable Lens and the Cornea (각막형상 및 각막난시도가 RGP렌즈와 각막사이의 눈물양에 미치는 영향)

  • Kim, Jihye;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.141-150
    • /
    • 2015
  • Purpose: In the present study, a difference in tear volume between the cornea and the rigid gas permeable (RGP) lens relative to corneal shape and corneal astigmatism was investigated by the alignment fitting status of spherical and aspherical RGP lenses. Methods: Spherical and aspherical RGP lenses were fitted with alignment in 77 subjects (135 eyes) who were in their 20~30s. Tear volume stained with fluorescein was qualitatively analyzed by dividing cornea into center, mid-peripheral and peripheral parts. Results: For the spherical RGP lens fitting, tear volume differences were found in each part in all corneal types. For the aspherical RGP lens fitting, tear volume differences were in each corneal part in symmetric bow tie- and asymmetric bow tie-type corneas. However, the tear was equally distributed from the center to the peripheral part in round- and oval-type corneas. In the group with corneal astigmatism lower than 1.25 D, tear volume between center and peripheral parts, and mid-peripheral and peripheral parts, was different when a spherical RGP lens was fitted. However, tear volume in each part was not different in the group with corneal astigmatism over 1.50 D. Moreover, the tear volumes of the central and mid-peripheral parts were proportionally increased with increasing corneal astigmatism in both spherical and aspherical RGP lenses. Furthermore, aspherical RGP lenses showed greater increments than spherical RGP lenses. Conclusions: The results revealed that the difference in tear volume between aspherical RGP lens and cornea was less than spherical RGP lens, and the difference in tear volume varied according to corneal shape and astigmatism. In addition, the method of measuring relative tear volume between RGP lens and cornea that was established in the present study can be used to evaluate tear volume between contact lens and cornea.

A Study of Abnormal Refraction Eye on the 30's employees (30대 직장인의 굴절이상안에 대한 연구)

  • Lee, Young-Il;Lee, Young-Dal
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.2
    • /
    • pp.115-119
    • /
    • 2001
  • To research the refractive error of the eyes on the 30's employees, 510 eyes were tested by the object and subject methods. The results were as follows. 1. Among the 510 eyes, myopia is 74.4%, hyperopia is 0.9% and emmetropia is 24.7%, respectively. 2. In test, the low myopia (-0.50Dt < Spherical Equivalent ${\leq}$ -2.00Dt) is 24.1%, the middle myopia(-2.00Dt < Spherical Equivalent ${\leq}$ -6.00Dt) is 51.4%, the high myopia(-6.00Dt < Spherical Equivalent) is 14.8% and the low hyperopia(+0.50Dt < Spherical Equivalent ${\leq}$ +2.00Dt) is 1.2%, respectively. 3. In test of astigmatism, the amount of astigmatism with-the rule is 58.5%, the amount of astigmatism against-the rule is 22.6% and the amount of astigmatism with oblique is 18.9%, respectively.

  • PDF

The Study of tear film stability for normal eyes in adults (성인 정상안의 눈물 안정성에 대한 연구)

  • Oh, Hyun-Jin;Doo, Ha-Young;Sim, Sang-Hyun;Choi, Sun-Mi;Oh, Seung-Jin
    • Journal of Convergence Society for SMB
    • /
    • v.6 no.4
    • /
    • pp.85-91
    • /
    • 2016
  • This study is to research the tear film stability for 48 eyes, agreed the purpose of study, didn't have no contact lens wearing and were tested all two times in a day. Their visual acuity was more than 0.8, corrective visual acuity more than 0.8, the fattest K-reading, apical corneal radius, was in 7.40~8.40mm, corneal astigment was less than 1.00D and orthophoria. The tests, tear scope test, tear film break up time test(TBUT) and schirmer test order, were performed their functions before and after their working at interval of 6 hours over. The tearscope test results was no difference, TBUT was no difference, although 1.2 seconds more in the afternoon, shcirmer test was decreased 2.0mm in the afternoon.

A Study on a Changed Power of Tear lens at Spherical RGP lens Fitting (구면 RGP렌즈 Fitting시 누액렌즈 굴절력 변화에 대한 연구)

  • Park, Seong-Jong;Joo, Seok-Hee;Jung, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.455-462
    • /
    • 2004
  • In this paper, we measured and analysised the power change of tear lens for 85 patients - 170 myopia eyes - who are fitted using RGP lens, considering the BGR of RGP lens, the corneal astigmatism power, and corneal curvature. We got the following results from these experiments; 1. When the BCR of RGP lens changes, the diopters of tear lens of "on-k", 0.05Pt, 01.0Ft, 0.05St, and 0.10St are -0.25D, -0.46D, -0.63D, +0.07D, and +0.26D, respectively. 2. When the corneal astigmatism power changes, the diopters of tear lens of group below 0.75D, group of 1.00D~1.25D, group of 1.50D~1.75D, and group over 2.00D in "on-k" state, are -0.25D, -0.18D, -0.09D, and -0.39D, respectively. 3. When the corneal astigmatism power changes and the BCR of test lens is changed by 0.05mm step, the change values of tear lens diopter for 0.05St and 0.05Ft approximate to ${\pm}0.25D$, while these for 0.10St and 0.10Ft don't approximate to the value below ${\pm}0.25D$.[are irregular value below ${\pm}0.25D$.] 4. When the corneal curvature and the HCR of RGP lens change, the diopters of tear lens of group below 7.50mm, group of 7.55~7.80mm, group of 7.85~8.20mm, and group over 8.25mm in "on-k" state, are -0.40D, -0.11D, -0.20D, and -0.19D, respectively. 5. When the BCR of test lens is changed by 0.05mm step and the corneal curvature increases, the change values of tear lens diopter decrease, while these over 8.25mm are mean value ${\pm}0.17D$ and the value below ${\pm}0.25D$.

  • PDF