A study on the Radiation exposure of simple abdomen x-ray in Radiography (복부 단순 X선검사시 피복 선량에 관한 연구)

  • Ko In Ho;Lee Kyung Sung;Shin Dong Yong
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.27 no.2
    • /
    • pp.57-65
    • /
    • 2001
  • This study was performed to measure about exposure dose during simple abdomen x-ray Radiography. The exposure dose was measured by PDD, surface dose, percentage scatter dose, respectively. The result was as followed: 1. When tube voltage were increased wi

  • PDF

Effect of an Acrylic Plate and SSD on Dose Profile and Depth Dose Distribution of 9 MeV Electron Beams (에너지 저하체로서 아크릴과 SSD 가 9MeV 전자선의 측방 및 깊이선량분포에 미치는 효과)

  • 강위생
    • Progress in Medical Physics
    • /
    • v.9 no.2
    • /
    • pp.65-71
    • /
    • 1998
  • The aims are to evaluate the effects of an 1.0 cm acrylic plate and SSD on the dose profile and depth dose distribution of 9 MeV electron beam and to analyse adequacy for using an acrylic plate to reduce energy of electron beams. An acrylic plate of 1.0 cm thickness was used to reduce energy of 9 MeV electron beam to 7 MeV. The plate was put on an electron applicator at 65.4 cm distance from x-ray target. The size of the applicator was 10${\times}$l0cm at 100 cm SSD. For 100cm, l05cm and 110cm SSD, depth dose on beam axis and dose profiles at d$\_$max/ on two principal axes were measured using a 3D water phantom. From depth dose distributions, d$\_$max/, d$\_$85/, d$\_$50/ and R$\_$p/, surface dose, and mean energy and peak energy at surface were compared. From dose profiles flatness, penumbra width and actual field size were compared. For comparison, 9 MeV electron beams were measured. Surface dose of 7 MeV electron beams was changed from 85.5% to 82.2% increasing SSD from 100 cm to 110 cm, and except for dose buildup region, depth dose distributions were independent of SSD. Flatness of 7 MeV ranged from 4.7% to 10.4% increasing SSD, comparing 1.4% to 3.5% for 9 MeV. Penumbra width of 7 MeV ranged from 1.52 cm to 3.03 cm, comparing 1.14 cm to 1.63 cm for 9 MeV. Actual field size increased from 10.75 cm to 12.85 cm with SSD, comparing 10.32 cm to 11.46 cm for 9 MeV. Virtual SSD's of 7 and 9 MeV were respectively 49.8 cm and 88.5cm. In using energy reducer in electron therapy, depth dose distribution were independent of SSD except for buildup region as well as open field. In case of using energy reducer, increasing SSD made flatness to deteriorate more severely, penumbra width more wide, field size to increase more rapidly and virtual SSD more short comparing with original electron beam. In conclusion, it is desirable to use no energy reducer for electron beam, especially for long SSD.

  • PDF

Monte Carlo Study Using GEANT4 of Cyberknife Stereotactic Radiosurgery System (GEANT4를 이용한 정위적 사이버나이프 선량분포의 계산과 측정에 관한 연구)

  • Lee, Chung-Il;Shin, Jae-Won;Shin, Hun-Joo;Jung, Jae-Yong;Kim, Yon-Lae;Min, Jeong-Hwan;Hong, Seung-Woo;Chung, Su-Mi;Jung, Won-Gyun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.192-200
    • /
    • 2010
  • Cyberknife with small field size is more difficult and complex for dosimetry compared with conventional radiotherapy due to electronic disequilibrium, steep dose gradients and spectrum change of photons and electrons. The purpose of this study demonstrate the usefulness of Geant4 as verification tool of measurement dose for delivering accurate dose by comparing measurement data using the diode detector with results by Geant4 simulation. The development of Monte Carlo Model for Cyberknife was done through the two-step process. In the first step, the treatment head was simulated and Bremsstrahlung spectrum was calculated. Secondly, percent depth dose (PDD) was calculated for six cones with different size, i.e., 5 mm, 10 mm, 20 mm, 30 mm, 50 mm and 60 mm in the model of water phantom. The relative output factor was calculated about 12 fields from 5 mm to 60 mm and then it compared with measurement data by the diode detector. The beam profiles and depth profiles were calculated about different six cones and about each depth of 1.5 cm, 10 cm and 20 cm, respectively. The results about PDD were shown the error the less than 2% which means acceptable in clinical setting. For comparison of relative output factors, the difference was less than 3% in the cones lager than 7.5 mm. However, there was the difference of 6.91% in the 5 mm cone. Although beam profiles were shown the difference less than 2% in the cones larger than 20 mm, there was the error less than 3.5% in the cones smaller than 20 mm. From results, we could demonstrate the usefulness of Geant4 as dose verification tool.

Calculation of Photon Spectra from the Tungsten Target for 10 MeV Electron Beam (10 MeV의 전자선이 텅스텐 표적에 충돌하여 생성되는 광자선 스펙트럼의 계산)

  • 이정옥;정동혁;문성록;강정구;김승곤
    • Progress in Medical Physics
    • /
    • v.10 no.1
    • /
    • pp.55-62
    • /
    • 1999
  • In an effort to study the characteristics of x-rays utilized in radiation therapy, we calculated the energy distribution and the mean energy of x-rays generated from a tungsten target bombarded by 6, 10, and 15 MeV electron beams, using a Monte Carlo technique. The average photon energies calculated as a function of the beam radius lied in 1.4 ∼ 1.6, 2.1 ∼ 2.5 and 2.8 ∼ 3.3 MeV ranges for 4, 10, and 15 MV electron beams, respectively, which turned out to have no strong dependence on the radius. Using the energy distributions of 6,10, and 15 MV x-rays obtained for the target distance of 100 cm, percentage depth doses were determined using Monte Carlo calculations. For the case 10 MV, a comparison was made between our calculation and measurement performed by others. The calculated percentage depth dose appeared somewhat smaller than the measured one except in the surface region. We conclude that this is due to the fact that the beam hardening effect resulting from the flattening filter was not properly allowed for in our Monte Carlo calculations.

  • PDF

A Monitoring Ability of the High-Performance Color CCD Camera under High Dose-Rate Gamma Ray Irradiation Environments (고 선량율 감마선 조사 환경에서의 고성능 칼라 CCD 카메라의 관측성능)

  • Cho, JaiWan;Choi, Young Soo;Seo, Yong Chil;Jeong, KyungMin
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2014.04a
    • /
    • pp.811-814
    • /
    • 2014
  • 일본 후쿠시마 제일 원자력발전소의 대지진/쓰나미에 이은 원자로 건물 수소폭발 사고의 수습 과정에서 사용후 핵연료 저장조에 보관되어 있는 핵연료의 안전문제가 대두되었다. 사용후 핵연료의 잔열 성분을 냉각시키고, 그리고 사용후 핵연료가 방출하는 고선량 방사선을 차폐시키기 위해서 일정 깊이 이상의 수조에 사용후 핵연료를 저장한다. 사용후 핵연료 저장조에 냉각수 공급이 중단되면, 사용후 핵연료의 고유 잔열에 의해 수조의 물이 증발하여 수위가 감소하게 된다. 계속해서 냉각수 공급이 되지 않으면, 사용후 핵연료의 잔열은 증가하게 되고, 수조의 물은 비등하여 증발은 가속화 된다. 사용후 핵연료 저장조의 수위가 고갈되면 고선량의 감마선이 방출된다. 수조의 수위가 정상적일 경우 사용후 핵연료 저장조의 공기중 감마선 선량율은 0.15mSv/h 이다. 수조의 수위가 사용후 핵연료 상부 꼭대기를 기준으로 2m, 1m, 및 0m (핵연료 노출) 로 감소하게 되면, 사용후 핵연료 저장조의 공기중 감마선 선량율은 500mSv/h, 50Sv/h, 및 5kSv/h 로, 급격히 증가한다. 본 논문에서는 사용후 핵연료 저장조 감시카메라의 관측 성능을 평가하기 위해, 고성능 칼라 CCD 카메라에 대해서 1 kGy/h 의 고선량율로 감마선 조사실험을 수행하였다. 이에 대한 실험결과를 기술한다.

Change of Dose Distribution on the Beam Axis of 60Co γ Ray and 10MV X-Ray with Part Thickness (치료부위(治療部位)두께에 따른 Co-60 γ선(線)과 10MV X선(線)의 선축상(線軸上) 선량분포(線量分布)의 변화(變化))

  • Kang, Wee Saing;Koh, Kyoung Hwan;Ha, Sung Whan;Park, Charn Il
    • Radiation Oncology Journal
    • /
    • v.1 no.1
    • /
    • pp.21-24
    • /
    • 1983
  • The thickness of the part being irradiated is finite. Percent depth dose tables being used routinely are generally obtained from dosimetry in a phantom much thickner than usual patient. At or close to exit surface, the dose should be less than that obtained from the percent depth dose tables, because of insufficient volume for backscattering. To know the difference between the true absorbed dose and the dose obtained from percent depth dose table, the doses at or close to the exit surface were measured with plate type ionization chamber with volume of 0.5ml. The results are as follows; 1. In the case of $^{60}Co$, percent depth dose at a given depth increases with underlying phantom thickness up to the 5cm. 2. In the case of $^{60}Co$, the dose correction factor at exit surface which is less than 1, increases with part thickness and decreases with field size. 3. Exposure time may not be corrected when the part above 10cm in thickness is treated by $^{60}Co$. 4. In the case of 10MV x-ray, the dose correction factor is nearly 1 and constant for the underlying phantom thickness and field size, so the correction of monitor unit is not necessary for part thickness.

  • PDF

Monte Carlo Calculation on the Dose Modulation Using Dynamic Magnetic Fields for 10 MV X-rays (움직이는 자기장을 이용한 10 MV X-선의 선량변조에 관한 몬테칼로 계산)

  • Kim, Ki Hwan;Oh, Young Kee;Shin, Kyo Chul;Kim, Jhin Kee;Jeong, Dong Hyeok;Kim, Jeung Kee;Cho, Moon June;Kim, Sun Young
    • Progress in Medical Physics
    • /
    • v.18 no.4
    • /
    • pp.221-225
    • /
    • 2007
  • Monte Carlo calculations were performed to demonstrate the dose modulation with dynamic magnetic fields in phantom. The goal of this study is to obtain the uniform dose distributions at a depth region as a target on the central axis of photon beam under moving transverse magnetic field. We have calculated the depth dose curves for two cases of moving magnetic field along a depth line, constant speed and optimal speed. We introduced step-by-step shift and time factor of the position of the electromagnet as an approximations of continuous moving. The optimal time factors as a function of magnetic field position were calculated by least square methods using depth dose data for static magnetic field. We have verified that the flat depth dose is produced by varying the speed of magnetic field as a function of position as a results of Monte Carlo calculations. For 3 T magnetic field, the dose enhancement was 10.1% in comparison to without magnetic field at the center of the target.

  • PDF

Fabrication and Dosimetry Characteristics of Intracavitary Cones for Radiotherapy (방사선 강내치료를 위한 소조사면 전자선cone의 선량분포 특성)

  • 나수경;권수일
    • Progress in Medical Physics
    • /
    • v.12 no.1
    • /
    • pp.95-102
    • /
    • 2001
  • The intracavitary cones were designed which were made of stainless steel and have scratched inside cone to be generated electron scatter and designed to be attached easily to the LINAC collimator and controlled cones length to be contacted smoothly between the patient and the cone tip. Two types of intracavitary cones were designed. One is the straight end cones with circular opening on the distal end and the other is 30 degree beveled end cones with elliptical opening on the distal end. Each type of intracavitary cone ranged in daimeter from 2.5 cm to 3.5 cm and required a separate set of lower trimmer annulias cone diameter. The film phantom was designed with an internal cassette that accurately aligned the film edge with the film phantom surface. Film optical density data were measured by photodensitometer(Wellhofer 700i) Dosimetry measurements were made to commission the LINAC for 6 - 20 MeV electron using the intracavitary cones. Isodose curves were measured for all energy and cones combinations. Output is defined as the maximum dose per MU along the clinical central axis in water at 113 cm SSD. Calibration output, defined to be the output for the 15cm$\times$15cm diameter straight cone, was adjusted to 1.00 cGy/MU at each energy according to the TG-21 protocol.

  • PDF

High Energy Photon Beam Modeling Using Transport Theory for Calculation of Absorbed Dose Distribution (흡수 선량 분포의 수송방정식을 이용한 10 MV X-선의 모델)

  • Choi, Dong-Rak;Chun, Ha-Chung;Lee, Myung-Za
    • Radiation Oncology Journal
    • /
    • v.10 no.1
    • /
    • pp.115-120
    • /
    • 1992
  • A mathematical model is presented for the calculation of the depth absorbed dose in water Phantom irradiated by high energy Photon beam (10MV X-ray), based on transport theory. The parameters of this model are obtained from the experimental values which were simulated by non-linear regression process method. The calculated absorbed dose distribution is extended to 3-D by using trial function from beam profile field sizes, SSD and depth in water phantom irradiated by high energy Photon beam. The calculated values using this model are in good agreement with the measured values.

  • PDF

Dose Distribution of Co-60 Photon Beam in Total Body Irradiation (Co-60에 의한 전신조사시 선량분포)

  • Kang, Wee-Saing
    • Progress in Medical Physics
    • /
    • v.2 no.2
    • /
    • pp.109-120
    • /
    • 1991
  • Total body irradiation is operated to irradicate malignant cells of bone marrow of patients to be treated with bone marrow transplantation. Field size of a linear accelerator or cobalt teletherapy unit with normal geometry for routine technique is too small to cover whole body of a patient. So, any special method to cover patient whole body must be developed. Because such environments as room conditions and machine design are not universal, some characteristic method of TBI for each hospital could be developed. At Seoul National University Hospital, at present, only a cobalt unit is available for TBI because source head of the unit could be tilted. When the head is tilted outward by 90$^{\circ}$, beam direction is horizontal and perpendicular to opposite wall. Then, the distance from cobalt source to the wall was 319 cm. Provided that the distance from the wall to midsagittal plane of a patient is 40cm, nominal field size at the plane(SCD 279cm) is 122cm$\times$122cm but field size by measurement of exposure profile was 130cm$\times$129cm and vertical profile was not symmetric. That field size is large enough to cover total body of a patient when he rests on a couch in a squatting posture. Assuming that average lateral width of patients is 30cm, percent depth dose for SSD 264cm and nominal field size 115.5cm$\times$115.5cm was measured with a plane-parallel chamber in a polystyrene phantom and was linear over depth range 10~20cm. An anthropomorphic phantom of size 25cm wide and 30cm deep. Depth of dose maximum, surface dose and depth of 50% dose were 0.3cm, 82% and 16.9cm, respectively. A dose profile on beam axis for two opposing beams was uniform within 10% for mid-depth dose. Tissue phantom ratio with reference depth 15cm for maximum field size at SCD 279cm was measured in a small polystyrene phantom and was linear over depth range 10~20cm. An anthropomorphic phantom with TLD chips inserted in holes on the largest coronal plane was bilaterally irradiated by 15 minute in each direction by cobalt beam aixs in line with the cross line of the coronal plane and contact surface of sections No. 27 and 28. When doses were normalized with dose at mid-depth on beam axis, doses in head/neck, abdomen and lower lung region were close to reference dose within $\pm$ 10% but doses in upper lung, shoulder and pelvis region were lower than 10% from reference dose. Particulaly, doses in shoulder region were lower than 30%. On this result, the conclusion such that under a geometric condition for TBI with cobalt beam as SNUH radiotherapy departement, compensators for head/neck and lung shielding are not required but boost irradiation to shoulder is required could be induced.